0% found this document useful (0 votes)
163 views2 pages

Vmonitor Multivariable Transmitter

The document describes a wireless multivariable sensor that can measure differential pressure, absolute pressure, temperature and other process variables. It provides details on the sensor specifications, mechanical specifications, wireless capabilities, power requirements, software and firmware details.

Uploaded by

Watanabe Koji
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
163 views2 pages

Vmonitor Multivariable Transmitter

The document describes a wireless multivariable sensor that can measure differential pressure, absolute pressure, temperature and other process variables. It provides details on the sensor specifications, mechanical specifications, wireless capabilities, power requirements, software and firmware details.

Uploaded by

Watanabe Koji
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

iMV

vMonitor TM

Creating the Digital Oilfield


Wireless Multivariable Sensor

SENSOR TYPE MECHANICAL SPECIFICATIONS


Foxboro IMV25 Multivariable Operating Temperature
• Differential Pressure Measurements from 0.5 to 840 in H2O • -40°C to +85˚C (-40 ˚F to + 185˚F)
• Absolute pressure Measurements from 3 to 5300psi • Humidity Range 5-90% non-condensing
• Process Temperature 100 ohm Platinum RTD General Dimensions
• 6.125” x 13.75” x 7.25” (W x H xD)
Enclosure
WIRELESS
• Direct Mount or Pipe Stand
• Type (Standard) 2.4 GHz: DSSS (direct Sequence Spread • FM-approved and CSA certify for Explosion proof for
Spectrum) Line of sight 2.2Km class1, Division 1, Groups A, B, C and Dust-Ignition
900 MHz: ISM, FSK, FHSS (Frequency Hopping Spread proof for class II/III, Division 1, Groups E, F and G; for

Spectrum) Line of sight 10Km hazardous( Classified ) Locations, indoors and outdoors.
• Aluminum pressure die – casting, max 0,5% Mg
Antenna
POWER • Hazardous Area Explosion Proof Antennas
• Gain 2DBi
• Input Range 6 to 12.0 VDC, 2 Watts Max
• Certifications UL listed for the following locations: Class
I Div 1, Groups C, D -40oC ≤ Ta ≤ +85 oC, Class I Zone 1
SOFTWARE DETAILS AEx d IIb T5, Ex d IIB T5 -40oC ≤ Ta ≤ +85 oC. CE 0539
II2G Ex d IIB T5, DEMKO
Operation Modes
• 08 ATEX 0727941X (see documents 35105 and 35106
• Continuous (Power)
for safe installation)
• Low power radio sleep mode (Battery operated)
Weight
Timer/Clock
• 11.5 Lbs
• On-board
Communication Protocols
• Wireless Messaging Protocol (WMP)
• MODBUS RTU
Firmware
• Multiphase flow estimator(water, gas, oil)
• Absolute pressure, Differential pressure, process tempera-
ture measurements
• Sensor and electronics temperature measurements
• Message Acknowledgements Verification (Guarantees mes-
sage delivery)
• 128 Bit Message Data Encryption
• Report by Exception
• System Diagnostics (Signal Strength, Message Count, etc)
• Network Registration & Authentication
• Raw data Engineering Units
• Conversion/Scaling/Alarms
• 32 bit CRC Error Checking

Abu Dhabi, U.A.E. - Tel: +971 2 6767 965, Fax: +971 2 6767 956, Houston, TX, U.S. Tel: +1 713 467 3900, Fax: +1 281 888 7626