ISO performance based on natural gas with
water injection to 25 ppmvd NOx.
GE Energy
LM 6000-PC Sprint
Power Output (KWe) 43,600 50,000
Heat Rate LHV (Btu/kWe-Hr) 8,500 8,400
Exhaust Flow (lbs/sec) 284 295
Exhaust Temperature (0F) 792 826
Emissions (ppmvd) NOx/CO
Gas or Liquid-DLE (15 ppm) 15/50, 65/25 15/50, 65/25
Gas or Liquid-DLE (25 ppm) 25/25, 134/25 25/25, 104/25
Gas or Liquid-Water 25/26, 42/6 25/32, 42/6
Gas-Steam 25/21 25/25
Power Turbine Speed (rpm) 3,600 3,600
No. of Compressor Stages 19 19
LM6000 Gas Turbine (60Hz) No. of Turbine Stages 7 7
TECHNOLOGY SERVICE
The LM6000 is an aeroderivative power generating gas turbine GE Energy is the world’s largest aeroderivative service
with thermal efficiencies in excess of 43.5%. provider, with a global network of field service offices and
• Baseload Power Capabilities of 43 – 50 MW ISO fully equipped Service Centers. A wide range of products
• Excellent Fast Start Capability; Able to Reach and services are offered for the LM6000 Industrial,
Maximum Power in 10 minutes Co-generation, and Oil & Gas operators including:
• Very Compact Size; Can Be Installed in Less Than 1 Acre
• Direct Drive at 3,600 rpm Output Speed – • Level IV Service Centers and overhaul
No Need for Reduction Gearbox capability in Houston, Texas and Rheden,
• Demonstrated Reliability and Availability; In Excess of the Netherlands
99% and 98% Respectively • Conversions, Modifications and Upgrades
• Lightweight, Modular Design – Easily Maintained and Transported (CM&Us) designed to enhance the efficiency,
power output and reliability of the LM6000.
EXPERIENCE Examples include Enhanced Flow and
The LM6000 is based on the CF6-80C2, the predominant engine Speed (EFS), Sprint Upgrade, PA-PC/PB-PD
for Boeing™ 747 and 767 wide-body aircraft, with over Conversions, Dry Low Emissions (DLE)
100 million hours of operation. Upgrades and Remote Monitoring
• Over 590 Power Generation Units Installed Worldwide and Diagnostics
with More Than Nine Million Operating Hours as of Sept. 2004 • Spare or Lease Engine Options
• Configurations: Simple-cycle, Cogeneration • Engine Exchange Programs
and Combined-Cycle • Rotable Hot Section and Module
• Application Flexibility: Exchange Programs
- Electric Utilities, Municipalities and Independent Power • Wide Variety of Contractual
Producers in Peaking and Combined Cycle Installations Service Agreements
- Industrial Users: Metallurgical Plants, Mining, Pharmaceuticals,
Pulp & Paper, Food Processing, Airports, Hospitals and Universities This comprehensive product offering, combined with our
- Oil & Gas Users: Refineries, LNG Plants and Offshore Installations commitment to reduce Service Center and outage turn
times, may result in substantial life cycle cost savings
INNOVATION for the plant owner/operator.
At GE Energy, we continue to drive innovation throughout
the whole gas turbine generator package.
• SPRINT®: (Spray Inter-cooling Technology) Optimal Hot Day
Power Enhancement
• 15ppm Dry Low Emissions Technology
• Fuel Flexibility
• VAR Stabilization
• Coal Feedwater Heating
www.gepower.com
LM6000 60Hz Output and Heat Rate
55,000 10,200
50,000 9,900
HEAT RATE (Btu /KWH)
45,000 9,600
OUTPUT (kW)
40,000 9,300
35,000 9,000
30,000 8,700
25,000 8,400
20,000 8,100
0 20 40 60 80 100 120 Dimensions Refer to Package Only
0
0 ft, 60% RH, 4/6 in H20 inlet/exhaust loss on natural gas AMBIENT ( F)
with water injection to 25ppmvd NOx water inj. LENGTH 57’ x WIDTH 13’6” x HEIGHT 14’6”
STANDARD 60H Z LM6000 GENERATOR PACKAGE OPTIONAL EQUIPMENT AND SERVICES
Gas Turbine • SPRINT®
• 19 Stage Axial Compressor • Generator Options
> 5 Stages Low Pressure and 14 Stages High Pressure > TEWAC
> Horizontal Split Casing > Voltages: 12.47kV
> 30:1 Compression Ratio > Enclosure
> 275 lb/s Nominal Inlet Mass Flow > Fault Protection
• Annular Combustor > Synchronous Condenser
> 30 Nozzles Gas Fuel, Water Injection for NOx Control • Fuel System
• Turbine Stages > Liquid
> 2 Stage High Pressure and 5 Stage Low Pressure Water Injection or DLE
Power Turbine > Dual
Generator Water Injection or DLE
• 13.8kV, 0.9PF Continuous Duty > Gas
• 2 Pole, 3 Phase, Brushless Exciter Water or Steam Injection or DLE
• WPII Weather Protected • Control System
• Voltage Regulator/Neutral Side Protection CT’s > Black Start
• NEMA Class F Insulation & B Temperature Rise > Continuous Emission Monitoring
• Integrated Protective Relay Panel > Remote Display
Package > Motor Control House
• 24V and 125V DC Batteries • Lube Oil System
• 85dBA Near Field Design > Air to Oil Coolers
• Barrier Inlet Air Filters > First Fill Lubricants
• 10 Minute Start Capability • Winterization
• Electro-Hydraulic Start/Shutdown System • Remote Monitoring and Diagnostics
• Class I Div 2 Group D Class Electrical System • Pulse Air Filter
• Digital Control System with a Human Machine Interface (HMI) • 80 dBA Capability
• Lube Oil System with Duplex Shell and Tube coolers • Inlet Conditioning
• Turbine Factory Tested to Full Speed, Maximum Power > Evaporative Cooling
• On/Off-line Water Wash > Chilling
• 1 Year Parts/Service Warranty and Remote > Heating
Monitoring and Diagnostics
• Package Familiarization Training
• Electronically Transmitted Drawings
• Start-up Technical Assistance
www.gepower.com