2424.5.
2019
May 2019 (1.0) QIG - Quick Installation Guide DCU 305 A R2 - Google Docs Publica on P/N: 1100587
What’s in the Box? User Interface Basics
1.
2.
DCU 305 Engine Controller
RK-66 Interface Module
Instrument Page
Bar graph gauges and Quick Installation Guide
3. Two connector cables Status bar.
DCU 305 A R2 P/N 1006400
4. Fastening material
5. Quick Installa on Guide
DCU 305 A R2 CAN P/N 1006402
Start Engine
Press and hold the Start
Bu on for manual start.
Stop Engine
Briefly hold the Stop Bu on
un l ac vated - indicated by
the LED.
Alarm-/Instrument View
Toggle between Alarm List
and Instrument view.
No alarm
Acknowledged
Unacknowledged
Instrument page/Event Log ■ 12 Switch inputs ■ Prelube func onality
Toggle between the two ■ 51Analogue inputs ■ Event Log
instrument pages. Press and ■ 2 Magne c pickup inputs ■ Ba ery monitoring
hold for Event Log. ■ 4 Speed relays ■ RPM monitoring
■ 21 Config. relays ■ Modbus RTU
Caution! ■ CAN/J1939 op on
More Information 1) Expandable
For the latest updated informa on, please contact your local
Handle with care when opening distributor or visit the Marine Plus 300 sec on at the Auto-Maskin
the bag and installing the units. website: h p://www.auto-maskin.com
Copyright © Auto-Maskin, 2019
https://docs.google.com/document/d/1ywzBy7SZatuSZRMuhu01fwkY_OTrlrmTiyVTFUxy2Ks/edit DCU 305 R2
1/2
2424.5.2019
May 2019 (1.0) QIG - Quick Installation Guide DCU 305 A R2 - Google Docs Publica on P/N: 1100587
Specifications Installation Configuration
Measurements (Main unit) 1. Wire all external connec ons to the The DCU must be configured using a Windows PC
Sec on Width Height Depth Unit RK-66 Interface Module: with the Rudolf Configura on So ware for DCU 305
Size 250 160 35 mm R2 installed. This so ware can be downloaded from
Cut-out 230 134 601 mm ■ Power
1) Min. required depth ■ Switch inputs the Auto-Maskin website:
h ps://www.auto-maskin.com/prod/rudolf-configura on-so ware-dcu-305
Power Ratings ■ Magne c pickup(s)
Sec on Min. Typ. Max. Unit ■ Analogue inputs The PC and the DCU (P3) connects together using
Power 18 24 32 VDC ■ Relays an RS-232/Rudolf Cable. If no COM port is available
Supply - 0.5 2 A
■ Remote controls at the PC, then a USB-adapter must be used. Note
Max ripple 10% without exceeding Min and Max values. that these cables are not included in this kit.
2. Determine the DIP switch 1-4 se ngs
RK-66 Interface Module Connectors behind the RK-66 rubber lid for A er a successful connec on, every single I/O and
power and noise reduc on op ons. informa on necessary for your setup must be
The Engine Controller is powered from the RK-66 Interface configured in these Rudolf Configura on So ware
Module. Also, the I/O signals are connected to the same 3. Install the Engine Controller in the
sec ons:
unit. cut-out using the submi ed fastening
material and ghten sufficiently. ■ Main ■ Ba ery
Connectors P1 & P2 Config MPU
to Engine Controller 1 & 2 2 Relays K1-9 4. Connect the cables P1 and P2 ■ Switch inputs ■ Informa on
between the Main unit and the RK-66 ■ Analogue inputs ■ Relays
module. ■ Standby Opera on ■ CAN (op onal)
■ Speed Sensor
Finally, at the rear side of the Engine Controller, set
For further details and informa on, please the Backup System Se ngs as advised by the
see the Installation Manual. Configura on so ware.
For further details and informa on, please see the
Power MPU Switch input Analogue input Remote Control
Rudolf Configuration Tool Manual.
1 1-12 1-5
Responsibilities Note Additional Documentation
It is the sole responsibility of the installer to ensure that the Auto-Maskin con nuously upgrades its products and reserves the Please visit the Auto-Maskin website h p://www.auto-maskin.com
installa on work is carried out in a sa sfactory manner and meet all right to make changes and improvements without prior no ce. for addi onal documenta on about the product.
applicable rules and regula ons.
Copyright © Auto-Maskin, 2019
https://docs.google.com/document/d/1ywzBy7SZatuSZRMuhu01fwkY_OTrlrmTiyVTFUxy2Ks/edit DCU 305 R2
2/2