0% found this document useful (0 votes)
334 views21 pages

Qubica Time Games Interface F-Out Game

The document provides installation instructions for connecting multiple F-OUT units to control time games. It describes the components, requirements, hardware setup including power supply, connections to the ET-HOST unit and between F-OUT units. It also provides details on addressing each F-OUT unit uniquely by connecting input pins on the unit to the power supply.

Uploaded by

taner inevi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
334 views21 pages

Qubica Time Games Interface F-Out Game

The document provides installation instructions for connecting multiple F-OUT units to control time games. It describes the components, requirements, hardware setup including power supply, connections to the ET-HOST unit and between F-OUT units. It also provides details on addressing each F-OUT unit uniquely by connecting input pins on the unit to the power supply.

Uploaded by

taner inevi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 21

F-OUT - Time Game Interface Installation Manual

F-OUT – Time Games Interface

F-Out
Installation Manual
Time Games interface
Installation Manual

February 2006 1
February 2006
F-OUT - Time Game Interface Installation Manual

Table of Contents

F-OUT – TIME GAMES INTERFACE 1


Table of Contents 2
1. Components 3
2. Requirements 4
3. Hardware Setup 5
3.1 Power Supply 5
3.2 ET-HOST Connection 6
3.3 F-OUT Connection 7
3.4 F-OUT Addressing 8
3.5 Low Voltage Output Wiring 11
3.6 High Voltage Output Wiring 12
4. Setup 13
4.1 Time Game Setup 13
5. F-OUT output signal Setup 20

February 2006 2
F-OUT - Time Game Interface Installation Manual

1. Components
The components contained in the kit (TOO-KIT-FOUT) are:
• TOO-BOX-FOUT (F-OUT Control Unit)
• CAB-TOO-FOUT (F-OUT Communication Cable)
• POW-SUP-FOUT (Power Supply)
• CNT-PHO-02F/P762, CNT-PHO-12F/P508 (F-OUT Output Connectors)

The following picture shows the components of the kit:

TOO-KIT-FOUT

F-OUT dimensions and weight:


• Length = 277.5 mm–10.93 in; Width = 134.5 mm–5.3 in; Depth = 49 mm–1.93 in
• Weight = 1,75 Kg – 3.86 lbs
CAB-TOO-FOUT:
• Length = 3 mt - 9.84 ft
Power supply specification:
• Input = 90-264 VAC; Output = 24 VDC 1.66 A

For installations involving BES Scoring System an ET-HOST Unit is required.


When shipped, F-OUT comes with the CAB-TOO-FOUT cable connected and the connectors
mounted.
The F-OUT board part number is: TOO-BOA-FOUT.

February 2006 3
F-OUT - Time Game Interface Installation Manual

2. Requirements

The proper electrical installation of the F-OUT Unit, for a high voltage environment (lamps, devices,
etc…), requires that the customer arranges in advance a subpanel, containing:

- relays, used to connect the F-OUT outputs to the lamps.


- appropriate power supply, able to drive the subpanel relays.

For more details about the subpanel, please refer to chapter 3.6.

Note:
The maximum number of F-OUT Units allowed to operate with Conqueror Pro is 12.
Each power supply (POW-SUP-FOUT) can drive up to 2 F-OUT Units.

February 2006 4
F-OUT - Time Game Interface Installation Manual

3. Hardware Setup
Suggested location:
Near the Front Desk. The distance between the F-OUT Unit and the ET-HOST cannot exceed 3 mt.
Alternative location (only with BES):
Near the billiard lights (or other time games) electrical distribution subpanel.

3.1 Power Supply


The POW-SUP-FOUT supplies power to the F-OUT Unit (Fig. 1).
Each POW-SUP-FOUT can drive up to 2 F-OUT Units.

1 J1 1 J4 1 J5 1 J3 1 J2

POW-SUP-FOUT

Fig. 1

February 2006 5
F-OUT - Time Game Interface Installation Manual

3.2 ET-HOST Connection


Use the CAB-TOO-FOUT cable supplied in the TOO-KIT-FOUT (see Fig. 2) to arrange the connection
between the ET-HOST and the first F-OUT.
Note: The maximum allowed distance between the ET-HOST and the first F-OUT is 3 mt - 9.84 ft.

The CAB-TOO-FOUT cable includes a resistor (150 Ohm, 1/4 W), between pins 7 and 8 of the J5
connector, to terminate the communication line.
The wirings for the J5 connector are shown in Tab. 1.

ET-HOST F-OUT

1 J1 1 J4 1 J5 1 J3 1 J2

IF YOU DON’T USE ADDITIONAL


F-OUT UNITS, OR IN THE LAST F-OUT,
CLOSE LINE WITH A 150 1/4 W
RESISTOR (PIN 7=A and 8=B)

Fig. 2

February 2006 6
F-OUT - Time Game Interface Installation Manual

3.3 F-OUT Connection


The same cable (CAB-TOO-FOUT) supplied with each TOO-KIT-FOUT Unit must be used to arrange
the connection between adjacent F-OUT Units in a chain.
The following steps are required to connect each F-OUT to the previous:

1) Cut the cable CAB-TOO-FOUT to remove the DB9 plug. Separate and skin the wires.

2) Connect the ‘A’,’B’,’C’ wires to the pins ‘7’,’8’,’9’ respectively of the J5 connector of the previous
F-OUT, as shown in Fig. 3. The wirings for the J5 connector are shown in Tab. 1.

3) Move the aforementioned resistor (150 Ohm, 1/4 W) to the last F-OUT unit.

1) F-OUT #1 F-OUT #2

1 J5 1 J5

ABC ABC

2) F-OUT #1 F-OUT #2 F-OUT #3

1 J5 1 J5 1 J5

ABC ABC ABC ABC A BC

Fig. 3

February 2006 7
F-OUT - Time Game Interface Installation Manual

J5 Connector
PIN Cable IN Cable OUT
1
2 A
3 B
4 C
5
6
7 A
8 B
9 C
10

Tab. 1

3.4 F-OUT Addressing

In installations/setups involving multiple F-OUT Units, it is necessary to assign unique addresses to


each Unit in the chain.
Perform the proper address configuration by taking the 24VDC, coming from the power supply
(POW-SUP-FOUT), into one (or more) couple of the CONFIG. input pins (IN 1- IN 4).

1 J1 1 J4 1 J5 1 J3 1 J2

PIN 9 10 11 12 PIN 9 10 11 12
IN 1
IN 3

IN 4

IN 2

Always ensure that the polarity is correct

February 2006 8
F-OUT - Time Game Interface Installation Manual

The address configuration follows the table shown below:

CONFIGURATION IN OUTPUT DRIVER


OUTPUTS
IN 3 IN 4 IN 1 IN 2 F-OUT NUMBER
OFF OFF OFF OFF 1-10 1
OFF OFF ON OFF 11-20 2
OFF OFF OFF ON 21-30 3
OFF OFF ON ON 31-40 4
OFF ON OFF OFF 41-50 5
OFF ON ON OFF 51-60 6
OFF ON OFF ON 61-70 7
OFF ON ON ON 71-80 8
ON OFF OFF OFF 81-90 9
ON OFF ON OFF 91-100 10
ON OFF OFF ON 101-110 11
ON OFF ON ON 111-120 12

IN# OFF: INPUT PINS DISCONNECTED


IN# ON: INPUT CONNECTED TO 24 VDC
(RESPECT THE POLARITY !!)

Examples of the correct address configuration for the F-OUT output driver:

1) F-OUT # 1

1 J1 1 J4 1 J5 1 J3 1 J2 CONFIGURATION IN
IN 3 IN 4 IN 1 IN 2
OFF OFF OFF OFF
F-OUT NUMBER # 1
+

2) F-OUT # 2

J1 J4 J5 J3 J2
1 1 1 1 1
CONFIGURATION IN
IN 3 IN 4 IN 1 IN 2
OFF OFF ON OFF
F-OUT NUMBER # 2
IN 1

February 2006 9
F-OUT - Time Game Interface Installation Manual

3) F-OUT # 3

1 J1 1 J4 1 J5 1 J3 1 J2
CONFIGURATION IN
IN 3 IN 4 IN 1 IN 2
OFF OFF OFF ON
F-OUT NUMBER # 3

IN 2
+

4) F-OUT # 4

J1 J4 J5 J3 J2
1 1 1 1 1
CONFIGURATION IN
IN 3 IN 4 IN 1 IN 2
OFF OFF ON ON
F-OUT NUMBER # 4
IN 1

IN 2

5) F-OUT # 5

1 J1 1 J4 1 J5 1 J3 1 J2
CONFIGURATION IN
IN 3 IN 4 IN 1 IN 2
OFF ON OFF OFF
F-OUT NUMBER # 5
IN 4

6) F-OUT # 6

1 J1 1 J4 1 J5 1 J3 1 J2
CONFIGURATION IN
IN 3 IN 4 IN 1 IN 2
OFF ON ON OFF
F-OUT NUMBER # 6
IN 4

IN 1

February 2006 10
F-OUT - Time Game Interface Installation Manual

3.5 Low Voltage Output Wiring


Each F-OUT Unit has 10 output switches, numbered from 1(left) to 10 (right).
When multiple F-OUT Units are used, the following output numbering scheme is used: 1-10, 11-20,
21-30, …..
Each output can drive a maximum load of 1A 40 V.

1 J1 1 J4 11 J5 J3 1 J2

+
OUT 1

OUT 2

OUT 3

OUT 4

OUT 5

OUT 6

OUT 7

OUT 8

OUT 9

OUT 10
OUT 1 - 5 OUT 6 - 9 OUT 10

EACH F-OUT OUTPUT CAN


DRIVE A MAXIMUM LOAD
OF 1 A 40 VOLTS DC/AC

QubicaAMF does not supply cables for the output connection.


Ensure that the cables have the correct size, according to the
maximum load (1A 40 V).

February 2006 11
F-OUT - Time Game Interface Installation Manual

3.6 High Voltage Output Wiring


F-OUT may be used to supply energy to high-voltage devices.
This can be made with a battery of relays, as shown below:

EACH F-OUT OUTPUT CAN


DRIVE A MAXIMUM LOAD
OF 1 A 40 VOLTS DC/AC

1 J1 1 J4 1 J5 1 J3 1 J2

OUT 10
OUT 6

OUT 9
OUT 7

OUT 8
OUT 1

OUT 4

OUT 5
OUT 3
OUT 2

ELECTRICAL DISTRIBUTION SUBPANEL

BILLIARD LIGHTS

V
20
0 V/2
11

Billiard # 1 Billiard # 2 Billiard # 3 Ping Pong # 1

February 2006 12
F-OUT - Time Game Interface Installation Manual

4. Setup

4.1 Time Game Setup

To create a new Time Game the following steps are required:

1) From the Conqueror Pro Main Menu, select:

SETUP > TECHNICAL SETUP > TIME GAME SETUP

February 2006 13
F-OUT - Time Game Interface Installation Manual

2) Create a new Time Game by pressing the ‘New’ button…

Fig. 4

…and insert the name for a new Time Game (e.g. BILLIARDS):

NOTE: For all the others fields that appear on Fig.4 (i.e. Walk-down Time, Rounding type,..) refer to
the Conqueror Pro manual.

February 2006 14
F-OUT - Time Game Interface Installation Manual

3) Press the ‘OK’ button. The following window appears:

Confirm the automatic creation of departments with the ‘Yes’ button. Conqueror Pro will restart.

4) After the reboot of Conqueror Pro, return to the Time Games Setup window shown in Fig. 4.
Here click on the upper ‘New’ button to create new resource items for the game:

February 2006 15
F-OUT - Time Game Interface Installation Manual

Specify:

- The number of resource items (i.e. BILLIARD tables) you want to create.
- The starting switch–relay.

Note: If the ‘Configure’ box is unselected, the system will work with F-OUT disabled.

Press ‘OK’ to confirm the new items.

February 2006 16
F-OUT - Time Game Interface Installation Manual

5) The newly-created Time Games settings are saved by pressing the ‘Save’ button:

You can repeat these steps to create other Time Games (e.g. Ping Pong):

Note: There is no limit to the number of Time Games you can create.

February 2006 17
F-OUT - Time Game Interface Installation Manual

The system will automatically assign the next-available starting switch relay, as shown in the follow-
ing example:

Anyway, for particular situations (i.e. outputs disabled) or when desired, the switches starting num-
ber may be modified.

February 2006 18
F-OUT - Time Game Interface Installation Manual

To modify or change an existing Time Game item settings:

Select the desired item (e.g. item number 8):

Press the ‘Modify’ button and a window appears that allows you to change the following settings:

- Availability to enable/disable the time game item


- Switch number for the item switch F-OUT output
- Reset the counter

February 2006 19
F-OUT - Time Game Interface Installation Manual

5. F-OUT output signal Setup

As an option, the F-OUT output can be arranged to work with an output pulse instead of using a
normally close contact.
This can be setup as follows:

1) From the Conqueror Pro Main Menu, select:

SETUP > CENTER SETUP

February 2006 20
F-OUT - Time Game Interface Installation Manual

2) Select the SCORE tab and set the pulse duration (in msec) as shown below:

The manufacturer cannot be responsible for any resulting injuries,


damages or malfunctioning of the equipment, due to the settings
made by the customer.

February 2006 21

You might also like