Electrical Calculator: - I2 Series
Electrical Calculator: - I2 Series
--I2 SERIES
General Information.................................................................................................................................... - 1 -
Safety at work............................................................................................................................................ - 2 -
1. Basic Data..............................................................................................................................................- 3 -
1.1 General information...........................................................................................................................- 3 -
1.2 Glossary...............................................................................................................................................- 4 -
1.3 The I2 series Calculator Description................................................................................................ - 5 -
1.3.1 The I2 calculator control inputs and outputs........................................................................... - 5 -
1.3.2 The side Inputs and Outputs...................................................................................................... - 7 -
1.3.3 Schematic diagram of I2 electrical system.............................................................................. - 13 -
1.4 Housing..............................................................................................................................................- 14 -
2. I2 series calculator settings................................................................................................................- 15 -
2.1 Hardware setting.............................................................................................................................. - 15 -
2.1.1 JP1 setting.................................................................................................................................. - 15 -
2.1.2 Reset/Boot setting...................................................................................................................... - 16 -
2.1.3 JMP1/JMP2 setting................................................................................................................... - 16 -
2.2 Software function enquiry and setting........................................................................................... - 17 -
2.2.1 Modes setup............................................................................................................................... - 17 -
2.2.2 Protocol chosen.......................................................................................................................... - 18 -
2.2.3 Normal function enquiry and settings..................................................................................... - 18 -
2.2.4 The list of I2 calculator parameter settings............................................................................ - 22 -
2.3 Diagram of I2 electrical calculator working principle..................................................................- 35 -
2.4The transaction limit.........................................................................................................................- 36 -
3. Technical Data.................................................................................................................................... - 38 -
4. Diagnostics.......................................................................................................................................... - 39 -
4.1 Error message................................................................................................................................... - 39 -
4.2 Survey of Error Codes..................................................................................................................... - 39 -
The manufacturer accepts no liability for any consequences resulting from inappropriate,
negligent or incorrect installation or adjustment of the optional operating parameters of the
equipment or from the incorrect installation
The contents of this manual are believed to be correct at the time of printing. In the interests of a
commitment to a policy of continuous development and improvement, the manufacturer reserves
the right to change the specification of the product or its performance, or the contents of the
guide, without notice.
All rights reserved. No parts of this manual may be reproduced or transmitted in any form or by
any means without permission in writing from the publisher.
Software version
The electrical calculator is produced and supplied with the latest software version. Higher
versions usually extend functions of the control system.
If there is any doubt, please contact Beijing SANKI Petroleum Technology Co.,Ltd
(www.sankichina.com)
-1-
Safety at work
Electrical safety - general warning
The voltage used in calculator's basic unit can cause injury that may result even in death.
Therefore it is necessary to follow the relevant safety standards valid for operation with electric
equipment, the installation and maintenance of the system must conform to relevant safety
regulations. The calculator must not be subjected to excessive mechanic force.
Environmental limits
Instructions in this manual regarding transport storage installation and use of the calculator must
be complied with including the specified environmental limits. The calculator must not be
subjected to excessive mechanic force
Safety of personnel
The power supply must be disconnected before any servicing work is performed.
To avoid security hazards or damage of the equipment do not connect the system to power supply
until you are fully acquainted with its function.
To avoid electric injury do not remove the outside cover or manipulate with the system under
voltage. The system contains capacitors that remain charged even several minutes after power
down. Maintenance and service of the system should be carried out by trained personnel only!
Adjusting parameters
Some parameters have a profound effect on the operation of the system. They must not be altered
without careful consideration of the impact on the controlled system.
-2-
1. Basic Data
1.1 General information
SANKI’s I2 series are electronic calculator that control the fuel pump dispensers.
I2 electrical system can control fuel dispensing both one site and two sites, i.e. one I2 motherboard
can control both 1 or 2 nozzle at the same time.
The I2 calculator can operate independently and/or can be controlled by a site control system(FMS).
The I2 calculator is connected to the site control system via the RS485/CURRENT LOOP lines,
which is controlled by its own communication protocol EASY-CALL, and/or according to IFSF
standards(communication level LON or TCP/IP-Ethernet).
The main advantages of the I2 calculator produced by SANKI Petroleum Technology Co.,Ltd. are
its reliability and its high performance, its low price and its guaranteed quality. The most
outstanding features of the calculators are as follows:
The high quality measurement;
Integrated Electronic Calibration of meters(EC);
Automatic Temperature Compensation of fuel(ATC).
Many expanded interfaces(support and connect printer, IC card, ID card, vapor recovery
system, site system with RS85/CURRENT LOOP standard, etc)
The I2 calculator controls all functions necessary for dispenser operation and no other
electronic devices are needed.
All the above mentioned features are accomplished at wide temperature range typical for pump
stations outdoor operation. The flexibility of the calculator is ensured by possible programming of a
wide range of functional parameters(i.e. required by different national standards, different dispenser
design parameters, adjustable position of the decimal points etc.)
The I2 calculator enables fuel dispensing in the pre-selection mode, i.e. customer is allowed to pre-
select the total volume and/or total amount of the fuel required.
-3-
1.2 Glossary
HARDWARE:
DISP – dispenser side display
Motherboard – I2 calculator controls all the dispensing function, authorize all commands for
dispensing and transmit data to site control system
Control board - controls starting up or shut down of solenoid valve and motor by using driving
signal
Keypad – input equipment of the computer device, to realize human-machine conversion
Keypad display – display the preset value and other related information
Sensor – convert the angle displacement of the flow meter to electrical pulse
Switch – the device controls startup and shutdown signal of dispenser
Filter – filter out high frequency clutter waves in power supply circuit
Transformer – convert strong power(AC) into weak power(AC)
Nozzle –the terminal unit of hydraulic system of a fuel dispenser
-4-
1.3 The I2 series Calculator Description
The I2 series calculator are an electronic control system based on the powerful single-chip
ARM7TDMI-S, the 32 bit central processing unit, which posses 512KB internal flash ROM(Read
Only Memory),32KB static SRAM(Static Radom Access Memory), ISP(In-System Programming),
IAP(In-Application Programming) function. The system fully controls fuel dispensing on both one
and/or two sites. Because of software program requiring large RAM, it expands another 64KB
SRAM.
The I2 calculator can be used for the high-speed dispensers. Because it measures the fuel flow of up
to 1000L per minute with accuracy less than 0.25%. the calculator has new function for
SUPERMAX dispenser. The calculator activates 2 pumps for high speed delivery in this case.
The I2 calculator is a compact device containing power supply, control logic, and the input/output
interface. Connectors of the system can be disconnected, which makes the exchange of the
calculator during service maintenance possible. The installation and service of the I2 calculator is
very simple.
The I2 calculator can be equipped with 2 separate displays on each dispensing site. The side display
shows the value of the transactions and other data displayed in various modes of the calculator
operation.
The I2 calculator is equipped with the electronic totals according to the IFSF standard. There are
non-erasable meter totals and erasable nozzle totals. Electronic totals can be read either via
dispenser keypad and/or via the communication line from the site control system. both nozzle totals
are allowed to record from the keypad and/or site control system. The internal electronic totals are
independent on the electromechanical volume totals. The IFSF(International Forecourt Standards
Forum) version of the calculator is equipped with all compulsory totals and other necessary
parameters according to the IFSF standard.
The keypad is used to set all of the calculator, the electronic calibration of the meters, setting of the
ATC and vapor recovery system control. It also enables the unit prices setting for the manual mode
of operation.
-5-
- IC card reader input
- Receipt printer input
- Speaker input
- Temperature detecting input
- Nozzle-up switch input
- Pulser input
- Output signal of motor startup
- Output signal of main and auxiliary solenoid valve
- Power supply input
- LED display input signal
- Indicator signal for sensor/motor/solenoid valve
- Electromagnetic totalizer input signal
Speaker
Ctr-C(10P)
Current Loop-PC
Parameter lock1/
Power module 2/3
Fuse(250V/2A)
Coefficient lock
-6-
Supply of control circuits at declared voltage range;
Secure data saving into the memory during power off;
Supply of power elements;
Supply of user pre-selection keypads;
Supply of user side display;
Supply of side printer;
Supply of side IC card reader;
Isolated voltage to interface circuits of the communication line;
Connection of shielding of all dispenser elements
Note: To secure power supply of the calculator, SANKI manufacturer advise to use the circuit
breaker with type C characteristic.(Schneider brand is advised)
Power supply
Strong power circuit: motor, solenoid valve, control board, anti-explosion power box in fuel
dispenser.
Attention:
1. 380VAC three-phase four wire, fuel dispenser using this power supply configured with three-
phase asynchronous motor;
2. 220 VAC, fuel dispenser using this power configured with single-phase motor ;
3. explosion-proof junction box, explosion-proof power box into holes in each line are equipped
with silk plugging, pads, they are designed for explosion-proof sealing, while preventing the wire
fall off or reverse.
Weak power circuit:The use of power supply for main board works and its interface.
Attention:
1. the main board and other integrated circuit use5VDC;
2. the driving parts of the main board use12VDC;
3. micro switch, parameter lock, sensor use12VDC;
-7-
Power filter:
SANKI filter falls within two-mesh type; it is fit for a variety of impedance matching
and may be helpful to tests such as Electrical Fast Transient (EFT), with required voltage
220VAC/50Hz, current 3A.
Transformer:
List of transformer parameters
For the power supply, SANKI engineer integrated the power board to motherboard. design the high
integration circuit, decrease the risk of PCB board burn out.
through filtering, transforming ,the strong power 220VAC/ 50HZ input into the power board, after
rectifying, filtering, stabilivolt, the output is DC12V, DC5V. The power board is used in fuel
dispenser with IC card connecting the console.
Power failure
When power failure is detected dispensing will stop immediately and transaction data is stored in
nonvolatile memory. The last valid values are displayed. The electromagnetic counter shows
transaction data for unlimited time after power failure. The LCD displays show the transaction data
for the time period minimum of 30 minutes.
When a short-time power failure occurs(the “short time” differs, can be up to 3 seconds)the startup
delay after normal power-on does not follow and the display tests immediately, and the customer
can set the time value for power failure –power on continue fueling.
-8-
power to strong voltage power. The control board circuit isolates high voltage interference signals
via photoelectrical isolating components.
In addition to drive motor and solenoid valve in high voltage electrical components outside, the
control board still has the function to send startup signal into the motherboard, and also undertake
the responsibility of sending electrical pulse to motherboard.
Jump cable:
JMP1,JMP2
Remark:
220V power input: the interface is connecting the power supply cable coming form anti-explosion power
box;
220V power output: the interface is connecting the power cable to power filter;
MA1&MA2: Control wires for motor side-A, connect to AC contactor A;
EA1&EA2: EA1 is the main valve wire of solenoid valve, EA2 is for the auxiliary valve wire of solenoid
valve(side-A);
MB1&MB2: Control wires for motor side-B, connect to AC contactor B;
EB1&EB2: EB1 is the main valve wire of solenoid valve, EB2 is for the auxiliary valve wire of solenoid
valve(side-B);
SW1&G12:Nozzle 1’s switch which startup fuel dispenser for dispensing;
SW2&G12:Nozzle 2’s switch which startup fuel dispenser for dispensing;
MAC_A&V12: Nozzle 1’s electromagnetic totalizer;
MAC_B&V12:Nozzle 2’s electromagnetic totalizer;
Side Displays
The side displays show the progress of a delivery. The I2 calculator can use for 2 side displays—
one display per side. But it can be add another pinboard to expand two displays per side.In addition,
to promote beautiful and harmonious, SANKI manufacturer specially designed separate displays.
There are two lines on the side displays for the main display, and 1 line for the slave display:
Total amount (7 digits)
SANKI CONFIDENTIAL AND PROPRIETARY
-9-
Volume (6 digits)
Unit price of the delivered product (5 digits)
The size of the digits is 25.4mm in all cases (1 inch).
Note: The number of decimal places (i.e. position of the decimal point) is set separately for all the
three displayed values:
Volume display
DJB/N displays the unit prices of the fuel. During the transaction the DJB/N displays only the price
of the delivered fuel. DJB/N is connected to the 10P connector of the main display.
Unit price
The unit price displayed is the unit price of the currently delivered product and/or product delivered
in the last finished transaction of the side. the decimal point settings can be different for unit
price/total amount/total volume via keypad operation.
The unit price can be adjusted via keypad operation or site control system(FMS).
Keypad display
The correct function of the keypad display is essential for the I2 calculator operation therefore any
failure of side displays can result in a fatal error causing the stop of a particular fuel delivery and
blocking of the calculator. Displays are connected to the calculator via the 10-core flat cable. For
SANKI CONFIDENTIAL AND PROPRIETARY
- 10 -
the correct function the address of the keypad display must be set by keypad.
Pre-selection keypad
The user pre-selection keypad can be connected to both dispensing sides. It enables the customer to
pre-select the volume and/or total amount of the fuel delivered. Most of the parameters can be
adjusted via pre-selection keypad.
(1)the regular SANKI keypad(5*4) is as bellow:
Keypad display
area
Function button P1 P2 P3 P4
area
ABC DEF
MENU 1 Digital button
2 3
area
GHI JKL MNO
FUN
4 5 6
*
L/GAL CANCEL
0
- 11 -
(2)the long membrane keypad is as bellow:
Digital preset
area
Function button
area
Flowrate switching
button area
Attention: the dispenser which configure with this special keypad must be chosen Australia
protocol;
The digital preset area, $1, $5, $10, $15, $20, $50: for preset the qualified value refueling;
Function button area:
Fill: clear the previous preset value, enter into non-preset status;
Clear: clear previous inputs, such as: preset value, flow rate chosen;
Stop: whatever preset or non-preset in current status, stop the fueling immediately;
Car: the normal flow rate(50L/Min); choose the flow rate firstly before fueling;(default 50L/Min)
Truck: the heavy duty flow rate(80L/Min); choose the flow rate firstly before fueling;(default
50L/Min)
- 12 -
1.3.3 Schematic diagram of I2 electrical system
When the user lifts the nozzle, the nozzle switch sends a start signal (SW) to the main board. When
the main board receives the SW signal, it issues a reset display command to the display board; the
liter and amount displayed on the display board are reset; in the meantime, the main board issues
such control signals as to open the solenoid valve and start the motor to the drive board; then the
assistant valve of the solenoid valve is opened, the motor is started, and the fuel dispenser enters
into a waiting for fueling condition.
When the user turns on the nozzle, fuel is dispensed into the fuel receiving container via the fuel
pump, fuel-gas separator, solenoid valve, flow meter, gas indicator, and nozzle etc. When fuel
flows through the flow meter, it moves the piston inside the flow meter back and forth to discharge
a certain volume of fuel, and rotates the output shaft of the flow meter via a series of drive
mechanisms. The output shaft drives the rotating of the raster disc (code disc) inside the sensor to
cut light beams, so that the sensor board produces counted pulse signals (each of which represents a
certain volume of fuel). After the main board receives these counted pulse signals, it rectifies,
computes and processes them, and sends the data to the display screen. The main valve of the
solenoid valve can be opened for high volume fueling only after the fueling volume of the fuel
dispenser is over 0.3 liters.
When the user hangs up the nozzle, the start signal (SW) is interrupted and the main board sends
signals to close the solenoid valve and turn off the motor, to the drive board. The main board saves
fueling data while the display screen keeps the displayed fueling data unchanged. Now the process
of fueling is completed.
The previous process of fueling is not preset fueling. If preset fueling is needed, the user should
input the preset quantity of fuel to be filled (measured by liter or sale) into the main board by using
SANKI CONFIDENTIAL AND PROPRIETARY
- 13 -
the keypad; when the quantity of fuel filled is close to the preset value (reaches the oil output value
to close the main valve). the main board sends a signal to close the main valve of the solenoid valve
to the drive board; when the quantity of fuel filled reaches the preset value, the main board sends
signals to close the auxiliary valve and turn off the motor to the drive board; the main board saves
fueling data while the display screen keeps the displayed fueling data unchanged. Now the process
of preset fueling is completed.
1.4 Housing
The I2 calculator is enclosed in a metal (aluminum casting) case with solid connectors for
connecting all parts of the dispenser. Also the control board and power supply parts should be
enclosed in its own case to prevent accident caused by high voltage or any other unexpended
factors.
Connection of all dispenser parts as well as connection of display/keypad can be done without
disassembling the case.
The transparent colored DISP LCN/N displays are delivered without case and must be installed in a
position securing effective back-lighting.
- 14 -
2. I2 series calculator settings
2.1 Hardware setting
Regarding the I2 series calculator, hardware settings are important and necessary, due to different
configuration, different software program, different communication methods, hardware setting is
essential to meet the demands of customized requirement.
JP1 locate in the I2 calculator, see the photo as above, with 8 pins, it can define different
configurations. The qualified definition is as follows:
Function requirement JUMPER No ON/OFF
1 OFF
Regular keypad(5*4)
7 OFF
1 ON
11 keys Special keypad(4*3)
7 OFF
Keypad switching mode
1 OFF
Long membrane keypad
7 ON
1 ON
Long keypad (Indonesia)
7 ON
80-80L/Min,50-50L/Min 2 OFF
Flow rate switching mode
80 to 50 L/Min 2 ON
Reserved NULL 3 NULL
Reserved NULL 4 NULL
5 OFF
1 nozzle
6 OFF
5 ON
2 nozzles
Nozzle No. for each side 6 OFF
(Side A&B) 5 OFF
3 nozzles
6 ON
5 ON
4 nozzles
6 ON
Share printer for both side Not share 8 OFF
A&B Share 8 ON
JP1 : open circuit(OFF):non-contact short circuiter; short circuit(ON):contact the short circuiter.
Regarding the flow rate switching, it refers to the double solenoid valves but single oil pipeline
SANKI CONFIDENTIAL AND PROPRIETARY
- 15 -
model dispenser, and the precondition is: the dispenser configure with SANKI’s regular keypad,
with parameter lock 3 short circuit, then the customer can operate and convert the flow rate mode
freely.
RESET mode: Normally, we use a short circuiter to put on the RESET pin, to avoid software
program crash caused by electrical interference, SANKI adopt the watchdog circuit. it will restart
the CPU automatically if the watchdog is not fed during 1.7s, the watchdog signal(3V~0.8V)
gradually damps in the ms level.
BOOT mode: Normally, the BOOT pin will be in an OPEN circuit mode, it will be short circuit
only when need upgrading software program. Under the BOOT mode, it will enter a guidance mode,
which will guide the customer to open the serial programming mode, then the operator can upgrade
new software program via the serial port CN12.
Due to SANKI adopting ARM central processing unit, with strong and powerful CPU, one I2
SANKI CONFIDENTIAL AND PROPRIETARY
- 16 -
motherboard can configure maximum 4 control boards, 8 nozzles. In order to define the sequence
No of control boards, it’s necessary to regulate the related Nos via hardware settings.
The SANKI’s non-IC card software program are divided into 4 level interfaces. Different level
defines different parameter menu ranks.
All of the 4 level’s interfaces are friendly, and gradation distinct, every level need password to be
entered, the default password is: ****.
NOTE: TO ENSURE SAFETY, PLEASE CONTACT US FOR PASSWORD!
The interface to the FMS is made through a serial channel (balanced current loop with galvanic
isolation). Optionally a RS485 interface is possible.
Current operation mode of the I2 calculator does not change even after power-off. To change the
mode set parameter level 2, item 2.
- 17 -
Note: Modification of parameter Online/Offline mode via the communication line is possible only
from the OFFLINE into the ONLINE mode.
For the regular non-IC card software program, the protocol can be communicated are concluded as
bellow:
No. PROTOCOL DESCRIPTION
common protocol, current loop or RS485, can fuel and operate independently
1 Common
or connect to SANKI’s or ITL’s FMS
RS485, can connect to Russia’s FMS which show 664 for total amount
2 Russia664
digit/volume digit/price digit
RS485, can connect to Russia’s FMS which show 765 for total amount
3 Russia765
digit/volume digit/price digit
can connect to Russia’s FMS which show 765 for total amount digit/volume
4 AZT2.0
digit/price digit
RS485, can connect to Gilbarco’s FMS via RS485 for Australia market
5 Australia
specially
Current loop or RS485, specially used in Thailand market, can connect to
6 General
SANKI’s FMS, ITL’s FMS, and local FMS of Thailand
RS232 communication port to LONG-WORKS port, can connect to any POS
7 IFSF
based on IFSF protocol.
Based on Gilbarco Protocol, can both adopting 2-wire current loop and
8 Global 1
RS485 to communicate with POSTEC.
Total volume is displayed on side displays on both total Sale and Liter lines:
Both side displays show the same value;
The first 2 character displayed from the left on the amount display is: “LL--” when the volume
totals is displayed;
The rest displaying digits show the volume totals;
Setting:
--make the nozzle/keypad under idle mode;
--press “PRICE” button, input default password: ****;
--Press “L/GAL” key to enter level 1;
--Press “11” or down-arrow button, press “L/GAL” key, then enter into volume totals interface;
SANKI CONFIDENTIAL AND PROPRIETARY
- 18 -
--Press “L/GAL” key, it reminds to choose a certain nozzle No;
--Press “L/GAL” key after choose some certain nozzle No(e.g. 1 or 2…)
--The current volume totals will show on both displays and keypad display;
--Press “CANCEL” key to return to idle status.
Setting:
--make the nozzle/keypad under idle mode;
--press “PRICE” button, input default password: ****;
--Press “L/GAL” key to enter level 1;
--Press “12” or down-arrow button to find: Query tot sales; Press “L/GAL” key, then enter into
sale totals interface;
--Press “L/GAL” key, it reminds to choose a certain nozzle No;
--Press “L/GAL” key after choose some certain nozzle No (e.g. 1 or 2…)
--The current sale totals will show on both displays and keypad display;
--Press “CANCEL” key to return to idle status.
In addition, setting the date & time can also well manage the final customers for overseas agency.
because this item is related to the working days for credit customers.
Setting:
--make the nozzle/keypad under idle mode;
--press “PRICE” button, input default password: ****;
--Press “L/GAL” key to enter level 1;
--Press “15” or down-arrow button to find item 15: Date & Time;
--Press “L/GAL” key, then enter into Date & Time interface;
--Input 15 digits for date and time contents (year(4 digits), month(2 digits), day(2 digits), hour(2
digits), minute(2 digits),second(2 digits), weekday(1 digit));
--Press “L/GAL” key to adapt new setting to the system;
--Press “CANCEL” key to return to idle status.
E.g: Preset Date & Time as 201605021123371;
Explanation: 2019—year; 05—month; 02—day; 11—hour; 23—minute; 37—second; 1—weekday;
(Mon-1; Tue-2; Wed-3; Thu-4; Fri-5; Sat-6; Sun-0)
- 19 -
Price setting (Level 2, item 4)
Unit price setting can be validated under both Offline/Online mode.
Attention: in Online mode, while operate pre-selection, the price may rely on the site controller,
some types site controller sends commands including inner set price, but some others will not
include its own inner price. The price from the dispenser will adjust itself according to related site
controller automatically.
Setting:
--make the nozzle/keypad under idle mode;
--press “PRICE” button, input default password: ****;
--Press “L/GAL” key to enter level 1;
--Press “19” or up-arrow button, press “L/GAL” key, then enter into Level 2;
--Press “24” or down-arrow button, until find the item 24: price;
--Press “L/GAL” key, it reminds to choose a certain nozzle No;
--Press “L/GAL” key after choose some certain nozzle No(e.g. 1 or 2…)
--Input new price;
--Press “L/GAL” key to adapt new price to the system;
--Press “CANCEL” key to return to idle status.
e.g: For normal meter, if we assume X=20, it means (X/100 +0.3)L=(20/100 +0.3)L=0.5L;
if we preset 10L, while fueling over 9.5L, the primary valve will shut-off automatically, only left
the auxiliary valve open and fueling the last 0.5L to the end.
Setting:
--make the nozzle/keypad under idle mode;
--press “PRICE” button, input default password: ****;
--Press “L/GAL” key to enter level 1;
--Press “19” or up-arrow button, press “L/GAL” key, then enter into Level 2;
--Press “26” or down-arrow button, until find the item 26: Master OFF valve;
--Press “L/GAL” key, it shows the previous existed value;
SANKI CONFIDENTIAL AND PROPRIETARY
- 20 -
--Input new “X” value (0-99);
--Press “L/GAL” key to adapt new value to the system;
--Press “CANCEL” key to return to idle status.
- 21 -
--Input default password: ****;
--Press “L/GAL” key, it will enter into Level 3;
--Press “312” or up and down arrow to find item 312: Price point;
--Press “L/GAL” key to enter into the price point interface;
--Input new price decimal places (0-3);
--Press “L/GAL” key to adapt new value to the system;
--Press “CANCEL” key to return to idle status.
Once power on, the dispenser will locate in the idle status, normally, SANKI company already set
the related parameter completely before delivery, hereby will introduce the operation for fueling
and setting parameters.
From the keypad, we can see the layout of 5*4 buttons, with mental materials. On top line, it’s “P1”,
“P2”, “P3”, “P4”, these buttons are used for preset a certain value which customer fuels frequently;
Besides preset total amount, the “P1”, “P2”, “P3”, “P4” with up/down/right/left arrows also
undertake the responsibility of setting parameters.
The first column is function buttons area, most of them are used for setting/enquiry or switch
parameters/modes.
The other digit buttons are used to input number or letter for fueling or setting related contents.
Regarding the 4 level software operating interfaces, every interface need to verify password to get
through, because of different parameter need different safety grade, the access permission of the 3
level escalates level by level. The implication of the level’s content is: the first number is level
grade, the next number is the sequence No of the item;
e.g. item 212: it means the item locate in level 2, and item No 12, the content is: Protocol;
Under level 1,2,3,4 commands, the general operations’ guidance are as follows:
1. Line 1 displays the title of the command or parameters to change;
2. TOP right corner, display up and down arrow↑↓and pencil logo;
3. Line 2 display the current parameter sequence number and name;
4. Use the up or down arrow ↑↓or enter a digit number(0-9) to scroll/change the parameter
name;
5. Press “L/GAL” key to adapt the current parameter;
- 22 -
6. Press backspace←to erase or back one char;
7. CANCEL key to exit the current setup menu, one step back;
8. When you enter level 4 commands from level 3, please turn on the switch of lock 2, after the
menu operation, please turn off lock 2 switch.
- 23 -
LEVEL 1:
1. Make sure the dispenser locate in the idle status;
2. Press “MENU” key, the password is recommended to input;
3. Input the default password“****”, then press “L/GAL” key to enter Level 1;
Level 1’s ITEM/DESCRIPTION/OPERATION
No Item Description Operation
Use the up and down arrow ↑or↓ or digit number 1-
8(available nozzles) to scroll/change nozzle No to
11 Query Tot Volume Query total volume for each nozzle display the tot volume;
Press “CANCEL” to exit;
Use the up and down arrow ↑or↓ or digit number 1-
8(available nozzles) to scroll/change nozzle No to
12 Query Tot Sale Query total sales for each nozzle
display the tot sales;
Press “CANCEL” to exit;
Query for the shift volume Use the up and down arrow ↑or↓ or digit number 1-
8(available nozzles) to scroll/change nozzle No to
13 Shift Volume
Shift volume is used for recording fueling display the shift volume;
data(Total volume) for the current shift Press “CANCEL” to exit;
Query total volume for other total Use the up and down arrow ↑or↓ or digit number 1-
8(available nozzles) to scroll/change nozzle No to
If fueling data of single time less than display the Other Tot volume;
14 Other Tots
0.06L/0.03L(0.01Gal),It will not be Press “CANCEL” to exit;
shown on the display, but will be counted
into the other total.
Query and set current date and time Press ”L/GAL” key to enter into the date & time set
process;
YEAR(4),MONTH(2),DATE(2),HOUR( Use the digit number to enter
2),MIN(2),SECOND(2)WEEKDAY(1) YEAR(4),MONTH(2),DATE(2),HOUR(2),MIN(2),SEC
OND(2)WEEKDAY(1);
15 Date & Time
WEEKDAY(0)= SUN; Must be 15 digits consecutively;
WEEKDAY(1)= MON; Press “L/GAL” key to save and validate the setting date
WEEKDAY(2)= TUE; and time;
... Press “CANCEL” to exit.
WEEKDAY(6)= SAT;
Change default preset type Press “L/GAL” key to enter the interface of changing
1:Sales preset mode;
2:Volume Use up and down arrow ↑or↓(1 or 2) to change the preset
16 Default Preset
Default : 1:Sales default mode as litre/sale
Press “L/GAL” key to adapt the modification;
Press “CANCEL” to exit;
Change the fixed preset keys P1-P4 value Press “L/GAL” key to enter the setting interface of
“Px” ;
“P1”,”P2”,P3”,”P4” is fixed sales amount Use up and down arrow ↑or↓ to select the P1 to P4;
preset key to preset how much to be Press “L/GAL” key to enter the related item, set the
refueled; corresponding preset value;
17 Preset Value
Press “L/GAL” to save and update the modified
Default : 1000 parameter set;
Range: 0-999999(sale point 2 decimals) Press “CANCEL” to exit;
0-9999999((sale point 1 decimal))
0-99999999((sale point 0 decimal)
Query the software version; Press “L/GAL” key to enter the interface of checking
program version;
Software version SK97V5.46(1) It displays the current software program version on
18 Version Notice: display;
(1):Standard; (2):Dual Flow meter; Press “CANCEL” to exit;
(3):Maide-40; (4):Maide-50; (5):KF-50;
(6):KF-80;
Enter level 2 interface; Press “L/GAL” key, it recommended to input password;
19 Enter Level 2 Input the correct password(**** default);
Press “L/GAL” key to enter into Level 2 interface;
- 24 -
LEVEL 2:
1. Make sure the operation locate under level 1;
2. Press “19” key, the interface indicate to show: Enter to Level 2;
3. Press “L/GAL” key, the password is recommended to input;
4. Input the default password“****”, then press “L/GAL” key to enter Level 2 interface;
Level 2’s ITEM/DESCRIPTION/OPERATION
No Item Description Operation
Recall the fueling transaction data Press “L/GAL” key to select proper nozzle;
(available for 200 sales records) Use the updown arrow ↑or↓or enter a digit number 1-8
available to scroll/change the nozzle number.
If more than 200 sales records, then the Press “L/GAL” key to enter the related nozzle interface;
21 Recall Txd Data first transaction data will be covered Use digit number(1 to 200) to select the related transaction
automatically to display, 1 is always the latest transaction in historical
record;
Press “CANCEL” to exit;
Change Online/Offline mode Press “L/GAL” key to enter into the “Online/Offline”
mode; 1 is set “Offline” in default, 2 is set “Online” a in
Default: 1:Offline default;
Range:1:Offline 2:Online Use updown arrow ↑or↓or input 1 or 2 to
scroll/switchover the mode;
Notice: Press “L/GAL” key after switchover the mode to save and
In online mode, the dispenser need the update new setting;
22 Online/Offline FMS’s authorization to do the refueling. Press “CANCEL” to exit.
Default:0
- 25 -
Special meter range(0-255)
Set the advanced volume to turn off the
master value.(NUM*10)/100L
EG:
n=2, the corresponding turn off master
value is set to 0.05+0.02=0.07 gallons.
When system in Ball type, this item is Press “L/GAL” key, select the corresponding nozzle;
valid. Use the updown arrow ↑or↓to scroll and select nozzle
Set the advanced time to turn off the number;
27 Valve OFF Time ball value. Input the new valve off time( 0-200)
Default 0 Press “L/GAL” key to save and update new setting;
Range:0-200 (One number means 20ms Press “CANCEL” key to exit;
)
The maximum amount of fueling Press “L/GAL” key, the display shows current max fuel-
allowed for a single time money value;
Default : 0 (unlimited) Input new Max Fuel-money value(0-999999999);
28 Max Fuel-money Range: (0-999999999) Press “L/GAL” key to save and update new setting;
Press “CANCEL” key to exit;
This item is valid, When Scroll ON in
level 3(Item 36 Scroll ON/OFF)
The maximum time of fueling allowed Press “L/GAL” key, the display shows current max fuel-
for a single time time;
29 Max Fuel-time Input new Max Fuel-time(0-9999);
Default : 0s (unlimited) Press “L/GAL” key to save and update new setting;
Range: 0-9999s Press “CANCEL” key to exit;
It's the time that motor keeps working
but dispenser is not refueling. If exceed Press “L/GAL” key, enter into the time out menu;
the setting time , then it will show Input the new time out value( 10-180)
210 Time out
alarm code 201:Time out Press “L/GAL” key to save and update new setting;
Default:180s Press “CANCEL” key to exit;
Range:10-180s
After lifting nozzle, the lasting time Press “L/GAL” key, enter into the transition time menu;
until display reset to 0; Input the new transition time value( 2-10)
Default:2s Press “L/GAL” key to save and update new setting;
Range: 2-10s; Press “CANCEL” key to exit;
211 Transition time
Notice: When set the item 321: Open
Pump First to ‘ON’ ,the setting time is
also the pump pressure testing time.
Select the communication protocol to Press “L/GAL” key, enter into the protocol menu;
the FMS: Use updown arrow↑or↓to scroll(or input 1-8 available
1: Common; protocol) and select the suitable protocol;
2: Rusia664; Press “L/GAL” key to save and update new setting;
3: Rusia765; Press “CANCEL” key to exit;
212 Protocol
4: AZT2.0;
5: Australia;
6: General;
7: IFSF;
8: Global 1;
Preset communication address for fuel Press “L/GAL” key, enter into the address menu;
dispenser (Pump ID) ; Input suitable communication address for dispenser;
Default:1 Press “L/GAL” key to save and update new setting;
213 Address Range: 1-99 Press “CANCEL” key to exit;
Notice:
1. For common protocol, no pump
address.
SANKI CONFIDENTIAL AND PROPRIETARY
- 26 -
2. The dispenser can communicate to
FMS only when set in online mode
under IFSF and GLOBAL 1 protocol)
e.g.
Company name:
215 Print Contents Station address:
City:
Tel Number:
Currency:
Dispenser No.
…
Nozzle No.
Product1
…
Product n
Footer 1
Footer2
Footer2
Exit;
With this item ON status, if keypad has Press “L/GAL” key, enter into the “Keyboard ON/OFF”
any issue or faults, there will be an menu;
alarm and error code displaying on Use updown arrow ↑or↓to scroll to convert keyboard
keypad display; ON/OFF(default is:1 Keyboard OFF): ;
216 Keyboard ON/OFF
Alarm code: 109 Keyboard error Press “L/GAL” key to save and update new setting new
setting is valid for all nozzles;
Default: 1:OFF Press “CANCEL” key to exit;
Range: 1:OFF 2: ON
With this item ON status, if Ctrlboard Press “L/GAL” key, enter into the “Ctrlboard ON/OFF”
has any issue or fault, there will be an menu;
alarm and error code displaying on Use updown arrow ↑or↓to scroll to convert Ctrlboard
keypad display; ON/OFF(default is:1 Ctrlboard OFF): ;
217 Ctrlboard ON/OFF
Alarm code: 110 ctrlboard error Press “L/GAL” key to save and update new setting, new
setting is valid for all nozzles;
Default: 1:OFF Press “CANCEL” key to exit;
Range: 1:OFF 2: ON
With this item ON status, if pulse has Press “L/GAL” key, enter into the “PulseErr ON/OFF”
any issue or fault, there will be an alarm menu;
218 PulseErr ON/OFF
and error code displaying on keypad Use updown arrow ↑or↓to scroll to convert PulseErr
display;
SANKI CONFIDENTIAL AND PROPRIETARY
- 27 -
Alarm code: 205 Pulser error ON/OFF(default is:1 PulseErr OFF): ;
Press “L/GAL” key to save and update new setting, new
Notice: setting is valid for all nozzles;
Sensor abnormal situation Press “CANCEL” key to exit;
1.Reverse one circle
2.Reciprocating vibration more than 5
times
After setting the item with ON status, Press “L/GAL” key, enter into “Re-print ON/OFF” menu;
press “.”Key to re-print after fueling; Use updown arrow ↑or↓to scroll to convert Re-print
This item is valid while set 214:Printer ON/OFF(default is:1 Re-print ON);
ON; Press “L/GAL” key to save and update new setting, new
Default: 1:OFF setting is valid for all nozzles;
219 Re-print ON/OFF
Range: 1:OFF 2: ON Press “CANCEL” key to exit;
Notice:
When item 214 is set with”ON” status ,
then this item is valid
Preset the minimum refueling volume Press “L/GAL” key, enter into the “Start Value” menu;
or sales to startup dispenser. It will be Input new Start value(minimum: Liter: 0.1L;
not allowed to refuel if preset value less Sale:0.1L*Price )
than the minimum limit. Press “L/GAL” key to save and update new setting, new
220 Start Value Default: 0.5L setting is valid for all nozzles;
Press “CANCEL” key to exit;
Notice:
The minimum refueling volume can be
set to 0.1L
Set the mode whether to print the Press “L/GAL” key, enter into “Plate Num ON/OFF”
vehicle plate No and Odometer No; menu;
Use updown arrow ↑or↓to scroll to convert Plate Num
With this item ON status, after ON/OFF(Default : 1:OFF);
221 Plate Num ON/OFF
refueling, press “.” key to print. Press “L/GAL” key to save and update new setting, new
setting is valid for all nozzles;
Default: 1:OFF Press “CANCEL” key to exit;
Range: 1:OFF 2: ON
Set the Print Format mode: Press “L/GAL” key, enter into the “Print Format” menu;
(1) :Standard; (2): Indonesia; Use up down arrow ↑or↓to scroll to convert Print
Format mode;(default is:1 standard);
222 Print Format Notice: Press “L/GAL” key to save and update new setting, new
When item 214 is set with ON status , setting is valid for all nozzles;
then this item is valid Press “CANCEL” key to exit;
Select the rounding mode. This item is Press “L/GAL” key, enter into the “Rounding” menu;
for "No preset" fueling, press "." to Use updown arrow ↑or↓to scroll to select the right
make dispenser stop at a integral rounding digit;(default is:1:1);
money. Press “L/GAL” key to save and update new setting, new
(1): 1; (2): 10; (3): 100; (4): 1000; (5): setting is valid for all nozzles;
10000; Press “CANCEL” key to exit;
223 Rounding Default: 1:
Range: 1: 1 2: 10 3: 100 4: 1000
5: 10000
Notice:
The setting is only valid for sales
amount rounding
After set Key Pre-start ON: Press “L/GAL” key, enter into the “Key Pre-start” menu;
Before a “Non-preset” fueling, it’s Use updown arrow ↑or↓to scroll to convert Key Pre-
necessary to press “CANCEL” key start ON/OFF(default is:1: OFF);
firstly. Press “L/GAL” key to save and update new setting, new
setting is valid for all nozzles;
Default: 1:OFF Press “CANCEL” key to exit;
224 Key Pre-start
Range: 1:OFF 2: ON
Notice :
The function just use for static
elimination and valid for metal keypad
- 28 -
If one dispenser is configured with 2 Press “L/GAL” key, enter into “Printer pinboard” menu;
mainboards and the 2 mainboards share Use updown arrow ↑or↓to scroll to convert printer
the same printer, then the Printer pinboard ON/OFF(default is:1: Pinboard OFF);
225 Printer Pinboard Pinboard is needed and this item should Press “L/GAL” key to save and update new setting, new
be set to ‘ON.’ 1:OFF setting is vaB lid for all nozzles;
2:ON Press “CANCEL” key to exit;
Default:1:OFF
Only valid when choose Ball valve in Press “L/GAL” key, enter into “Printer pinboard” menu;
Item25: Valve models. Use updown arrow ↑or↓to scroll to convert Use/Not Use
Bypass valve is used to eliminate the Bypass valve(default is:1: Not Use Bypass valve);
overshoot in preset refueling. Press “L/GAL” key to save and update new setting, new
226 Bypass valve
setting is valid for all nozzles;
1:No use bypass valve Press “CANCEL” key to exit;
2:Use bypass valve
Default: 1:No use bypass valve
Price 2 is an additional price choice and Press “L/GAL” key, enter into “Price 2” menu;
it can be set from POS or by the Use updown arrow ↑or↓to scroll to choose nozzle No.,
keypad. (range from 1 to 8);
Select 1 nozzle, press”L/GAL” key to enter, then set new
Notes: Need to be set after the decimal price wanted, then press “L/GAL” key to save and update
227 Price 2
places of the amount, volume and unit new setting, new setting is valid for all nozzles;
price are set. Need to be reset if any Press “CANCEL” key to exit;
modification of the decimals
- 29 -
side (SK52 series with 1nozzle or 2 setting is valid for all nozzles;
nozzles), there are 2 PPU boards for Press “CANCEL” key to exit;
each nozzle.
If choose to use PPU board DIB-A2,
this item need to set to ‘ON’, and each
DIB-A2 has its own address.
1:OFF
2:ON
Default:1:OFF
This function is valid only when using Press “L/GAL” key, enter into “Check M-counter” menu;
Ctrl board F6V01 and F7V01. Use updown arrow ↑or↓to scroll to choose suitable
Check whether the function of M- mode;
counter is normal. Press “L/GAL” key to save and update new setting, new
233 Check M-counter 1:OFF setting is valid for all nozzles;
2:ON Press “CANCEL” key to exit;
Default:1:OFF
Alarm if any abnormal is detected
Alarm code:206:Magnetic error
This item only validate under Australia Press “L/GAL” key, enter into “Australia Dis 5S” menu;
and GLOBAL 1 protocol. Use updown arrow ↑or↓to scroll to choose suitable
Lifting the nozzle, the pump will start mode;
234 Australia Dis 5S after the unit price shows 5seconds. Press “L/GAL” key to save and update new setting, new
1:ON setting is valid for all nozzles;
2:OFF Press “CANCEL” key to exit;
Default:2:OFF
The display of liters starts from 0.06L Press “L/GAL” key, enter into “Start Dis 0.06L” menu;
or 0.03L. Use updown arrow ↑or↓to scroll to choose suitable
1:ON(0.06L) mode;
2:OFF(0.03L) Press “L/GAL” key to save and update new setting, new
235 Start Dis 0.06L
Default value: 1:ON setting is valid for all nozzles;
Notes: only valid when measured in Press “CANCEL” key to exit;
Liter. The display of Gallon starts from
0.01gal by default.
Whether allow to print the shift data. Press “L/GAL” key, enter into “Print shift” menu;
1:OFF Use updown arrow ↑or↓to scroll to choose suitable
2: ON mode.
236 Print shift Default:1:OFF Press “L/GAL” key to save and update new setting, new
Print shift operation: ‘FUN’ + ‘.’ setting is valid for all nozzles;
Press “CANCEL” key to exit;
Enter Level 3 interface Press “L/GAL” key to input password “****”;
237 Enter Level 3
Press “L/GAL” key again to enter Level 3;
LEVEL 3:
1. Make sure the operation locate under level 2, item 237;
2. Press “L/GAL” key, the password is recommended to input;
3. Type in default password “****”;
4. Press “L/GAL” key, enter into Level 3 interface;
Level 3’s ITEM/DESCRIPTION/OPERATION
No Item Description Operation
Modify the value of electronic volume Press “L/GAL” key, enter into “Set Volume Tot” menu;
total for each nozzle Use updown arrow ↑or↓to scroll to select corresponding
Range: 0-4294967295; nozzle(1-8 available nozzles);
Press “L/GAL” key, enter the corresponding nozzle item;
31 Set Volume Tot Notes: Press “SALE” pencil button to enter modifying interface;
1, Volume Total need to be set after Input new Volume tot value ;
setting the decimal of the amount, Press “L/GAL” key to save and update new setting, new
volume and unit price ,and volume total setting is valid for single nozzles;
Need to be reset if any modification of Press “CANCEL” key to exit;
SANKI CONFIDENTIAL AND PROPRIETARY
- 30 -
the decimals
2,The total volume can be modified
only when Item 46:Electronic Total
Modified Enable is set to ‘ON’
Query the records of modifying Press “L/GAL” key, enter into the “Query Tot Change”
electronic volume totalizer; menu;
Use updown arrow ↑or↓to scroll to select corresponding
Only record the last 10 changes nozzle(1-8 available nozzles);
Press “L/GAL” key, enter the corresponding nozzle item;
Query Volume Use updown arrow ↑or↓to scroll to check related
32
Total records or press digital number‘0’ to ‘9’, input the
number and it can be automatically matched. Range: 1-10;;
Press “CANCEL” key to exit;
Set the maximum working days for the Press “L/GAL” key, enter into the “Set Working Days”
fuel dispenser and the dispenser will be menu;
forbidden for delivery after the working Press “SALE” pencil button to enter setting interface;
33 Set Work Days days you set; Input working days(0-365 available, default value is: 0); ;
Range: 0-365; Press “L/GAL” key to save and update new setting;
Default:0(No limit); Press “CANCEL” key to exit;
This setting is valid for all nozzles
Set the up-limit flow rate, the dispenser Press “L/GAL” key, enter into the “Set Flowrate UPL”
will alarm while the flow rate exceeds menu;
the set value(Alarm code 203:Over Press “SALE” pencil button to enter setting interface;
34 Set Flowrate UPL
Flowrate UPL); Input up-limit flowrate value(0-9999, default value is: 0) ;
Range: 0-9999L/Min; 0-9999Gal/Min; Press “L/GAL” key to save and update new setting;
Default: 0(Disabled) Press “CANCEL” key to exit;
After a sudden power failure, if the Press “L/GAL” key, enter into the “Refuel Interval”
power is restored within the set interval menu;
value, the last transaction can be Press “SALE” pencil button to enter setting interface;
35 Refuel Interval resumed and the delivery can be Input refuel interval value(0, 30-180, default value is: 0) ;
continued. Press “L/GAL” key to save and update new setting;
Range: 0s, 3-180s; Press “CANCEL” key to exit;
Default:0(Disabled)
The sales amount display digit can Press “L/GAL” key, enter into the “Scroll ON/OFF”
expand from 7 digits(max) to 9 menu;
digits(max) when set Scroll ON(the Use updown arrow ↑or↓to scroll to convert Scroll
screen will skip to next page to show ON/OFF(default is:1: Scroll ON);
36 Scroll ON/OFF
surplus digits automatically); Press “L/GAL” key to save and update new setting, new
1: Scroll ON; 2: Scroll OFF; setting is valid for all nozzles;
Default: 1:Scroll ON Press “CANCEL” key to exit;
This setting is valid for all nozzles;
Accumulate other volume total into or Press “L/GAL” key, enter into the “Other Tot ON/OFF”
not into the electronic volume totalizer. menu;
Use updown arrow ↑or↓to scroll to convert Other Tot
37 Other Tot ON/OFF 1:OFF 2:ON ON/OFF(default is:1OFF);
Default:1:OFF Press “L/GAL” key to save and update new setting, new
setting is valid for all nozzles;
Press “CANCEL” key to exit;
Change the password of Level 1, Level Press “L/GAL” key, enter into the “Change Password”
2, Level 3 respectively; menu;
Use updown arrow ↑or↓to scroll to choose password
level(Level 1&2&3);
Press “L/GAL” key to enter new password input interface
38 Change Password of selected level;
Input new password(4 digits number);
Press “L/GAL” key to prompt input new password again;
Input new password and confirm again;
Press “L/GAL” key to save and update new setting, new
setting is valid for all nozzles;
Press “CANCEL” key to exit;
Reset password to the default Press “L/GAL” key, enter into the “Reset Password”
39 Reset Password value(****). menu;
Press “L/GAL” will ask you enter a password of changing
- 31 -
password which is "1234".
Input the changing password;
Press “L/GAL” key to reset password;
Press “CANCEL” key to exit;
Set decimal places for sales amount Press “L/GAL” key, enter into the “Sale Point” menu;
display.(0-2) Use the updown arrow ↑ or ↓ or enter a digit number 0-2
310 Sale Point to select the Point.
Press “L/GAL” key to store the new set.
Press “CANCEL” key to exit;
Set decimal places for liter/gallon Press “L/GAL” key, enter into the “Volume Point” menu;
display(0-3) Use the updown arrow ↑ or ↓ or enter a digit number 0-3
311 Volume Point to select the Point.
Press “L/GAL” key to store the new set.
Press “CANCEL” key to exit;
Set decimal places for unit price Press “L/GAL” key, enter into the “Price Point” menu;
display.(0-3) Use the updown arrow ↑ or ↓ or enter a digit number 0-3
312 Price Point to select the Point.
Press “L/GAL” key to store the new set.
Press “CANCEL” key to exit;
In amount preset model, set the Press “L/GAL” key, enter into the “SV-Symbol” menu;
conversion from sale to volume. Enter a digit number 0-9 to select the Point.
(Set to n, n round-down, n+1 round-up); Press “L/GAL” key to store the new set.
Range:0-9 Default:4 Press “CANCEL” key to exit;
EG:
Sale 10.00
313 SV-Symbol Unit price 3.00
10/3=3.333,
1, Set n = 3,
the third decimal value 3≤n,
so the Liter will show 3.33
2, set n=2,
the third decimal value 3>n,
so the Liter will show 3.34
In Liter preset or no-preset model, set Press “L/GAL” key, enter into the “VS-Symbol” menu;
the conversion from volume to sale. Enter a digit number 0-9 to select the Point.
(Set to n, n round-down, n+1 round-up); Press “L/GAL” key to store the new set.
Range:0-9 Default:4 Press “CANCEL” key to exit;
EG:
Liter 3.33
314 VS-Symbol Unit price 4.50
Sale = 3.33*4.50=14.985
1, Set n = 4,
the third decimal value 5>n,
so the Sale will show 14.99
2, set n=5,
the third decimal value 5≤n,
so the Liter will show 14.98
Whether ID card device is enabled. Press “L/GAL” key, enter into the “ID Card ON/OFF”
When set ID card ON, swipe the ID menu;
card first and then do the refueling. Use ↑ or ↓ or 1 or 2 to select Keypad ON/OFF.
315 ID Card ON/OFF
1:OFF Press “L/GAL” key to update the valid status.
2:ON Press “CANCEL” key to exit;
Default:1:OFF
When using ID card device, the Press “L/GAL” key, enter into the “ID Card AuthMode”
refueling times for ID card can be menu;
limited. Use ↑ or ↓ or 1 or 2 to select ID Card AuthMode
316 ID Card AuthMode
1:Unbounded (1:Unbounded; 2:Bounded).
2:Bounded Press “L/GAL” key to update the valid status.
Default:1:Unbounded Press “CANCEL” key to exit;
Save the current parameters Press “L/GAL” key, enter into the “Save Settings” menu;
configuration. Press “L/GAL” key will ask you to confirm for saving the
317 Save Settings settings command. Save all the current settings to memory.
Press “L/GAL” key again will save the current settings and
display "Settings Saved".
SANKI CONFIDENTIAL AND PROPRIETARY
- 32 -
Press “CANCEL” key to exit;
Restore the parameters configuration Press “L/GAL” key, enter into the “Recover Settings”
saved in Item:317. menu;
Press “L/GAL” key will ask you to confirm for Recover
318 Recover Settings Settings command.
Press “L/GAL” key again will recover the stored settings
as current parameters and display "Settings Recovered".
Press “CANCEL” key to exit;
In online mode, whether enable to set Press “L/GAL” key, enter into the “Key Modify Price”
the unit price by keypad. menu;
Use ↑ or ↓(or press digital number“1” or “2”) to select
319 Key modify Price 1: ON; Key Modify Price mode
2: OFF Press “L/GAL” key to update the valid status.
Default:1:ON Press “CANCEL” key to exit;
Valid under Australia and Global 1 Press “L/GAL” key, enter into the “Price Unit” menu;
protocol, the price unit can be set to Use ↑ or ↓(or press digital number“1” or “2”) to set
Dollar or Cent(The multiple price unit(1:Dollar; 2:Cent).
relationship between unit price and Press “L/GAL” key to update the valid status.
320 Price Unit
sales amount) Press “CANCEL” key to exit;
1:Cent;
2: Dollar;
Default:2:Dollar
While lifting nozzle, startup the Press “L/GAL” key, enter into the “Open Pump Fist”
motor/pump first for bulge test to detect menu;
leakage and then the open the solenoid Use ↑ or ↓(or press digital number“1” or “2”) to set
321 Open Pump First valve. whether need the bulge test for leakage.
1: OFF; Press “L/GAL” key to update the valid status.
2: ON; Press “CANCEL” key to exit;
Default:1:OFF
Only valid under Common protocol. Press “L/GAL” key, enter into the “Offline Data” menu;
Whether the dispenser transmit offline Use ↑ or ↓(or press digital number“1” or “2”) to set
data to POS or not; whether need to transmit offline data to POS.
322 Offline Data
1: Not Needed; Press “L/GAL” key to update the valid status.
2: Needed; Press “CANCEL” key to exit;
Default:2:Needed
Under Australia and Global 1 protocol, Press “L/GAL” key, enter into the “Single Fuel point”
the dispenser default has 2 addresses menu;
(Side A, Side B), but for one nozzle Use updown arrow ↑or↓to modify “Single Fuel point”
323 Single Fuel Point dispenser, only need one address. or not;
1:OFF Press “L/GAL” key to store the new set;
2:ON Press “CANCEL” key to exit;
Default:1:OFF
Modify the value of electronic amount Press “L/GAL” key, enter into “Set Amount Total” menu;
total for each nozzle Use updown arrow ↑or↓to scroll to select corresponding
Range: 0-4294967295 nozzle(1-8 available nozzles);
Press “L/GAL” key, enter the corresponding nozzle item;
Notes: Press “SALE” pencil button to enter modifying interface;
1, Volume Total need to be set after Input new Volume tot value ;
324 Set Amount Total setting the decimal of the amount, Press “L/GAL” key to save and update new setting, new
volume and unit price ,and volume total setting is valid for single nozzles;
Need to be reset if any modification of Press “CANCEL” key to exit;
the decimals
2,The total volume can be modified
only when Item 46:Electronic Total
Modified Enable is set to ‘ON
Query the records of modifying Press “L/GAL” key, enter into the “Query Sale Total”
electronic sales amount totalizer; menu;
Only record the last ten changes Use updown arrow ↑or↓to scroll to select corresponding
Query Amount nozzle(1-8 available nozzles);
325
Total Use updown arrow ↑or↓to scroll to check related
records or press digital number‘0’ to ‘9’, input the
number and it can be automatically matched.
Press “CANCEL” key to exit;
This item is valid only when item 43: Press “L/GAL” key, enter into the “Calibrate Dual meter”
Calibrate Dual Set Meter Type is set to Dual flow menu;
326
Meter
meter model. Use the updown arrow ↑ or ↓ or enter a digit number 1-3
SANKI CONFIDENTIAL AND PROPRIETARY
- 33 -
In the calibration mode, only one flow to select adjust mode.
meter can work; Press “L/GAL” key to update;
If flow meter 1 is calibrated, only Press “CANCEL” key to exit;
equipment such as pump and solenoid
on this pipeline loop can work;
The calibration can be done by
electronic calibration or mechanical
calibration;
After the calibration is completed,
choose item 1: Cancel Calibrate or Re
power-on to exit calibration mode.
1: Cancel Calibrate
2: Calibrate meter 1
3: Calibrate meter 2
For some errors occur, the dispenser is Press “L/GAL” key, enter into the “Clear Alarmcode
prohibited to fuel unless the alarmcode Saved in Flash” menu;
has been cleared. Press “L/GAL” key to update;
Clear Alarmcode
327 Enter into the menu, and the keypad Press “CANCEL” key to exit;
Saved in Flash
display will prompt ‘clear?’, the press
“L/GAL” key to make sure the
operation.
Enter Level 4 interface Firstly, turn “Lock 1” clockwise 90°to the right position;
328 Enter level 4 Press “L/GAL” key to input password “****”;
Press “L/GAL” key again to enter Level 4;
Level 4
1. Make sure the operation locate under level 3, item 326;
2. Turn “Lock 1” clockwise 90°to the right position;
3. Press “L/GAL” key, the password is recommended to input;
4. Type in default password “****”;
5. Press “L/GAL” key, enter into Level 4 interface;
Range:
Standard and Dual flowmeter:9700-
12500,other:9000-99999
Note: This is only valid in version Press “L/GAL” key, enter into the “Coefficient records”
SK97V546E. If SK97V546, then menu;
prompt: Forbidden. Use updown arrow ↑or↓to scroll to check related
records or press digital number‘0’ to ‘9’, input the
42 Query the records of modifying the
Coefficient records number and it can be automatically matched.
Coefficient for each nozzle. Range: 1-10;
Only record the last 10 changes.
Use '←' to clear the input value.
Press “CANCEL” key to exit;
Set Meter type Press “L/GAL” key, enter into the “Set Meter Type”
menu;
1:Standard Use the updown arrow ↑ or ↓ or enter a digit number 1-
2:Dual flow meter 6(available meter model) to select the meter model.
43 Set Meter Type
3:Maide -40 Use '←' to clear the input value.
4:Maide -50 Press “CANCEL” key to exit;
5:KF-50
6:KF-80
44 Measure Unit Set measure unit. Press “L/GAL” key, enter into the “Measure Unit” menu;
- 34 -
Use the up and down arrow ↑/↓or1/2/3 to choose
1:Liter; 2:American Gallon; 3:Imperial measure unit.
Gallon Press “L/GAL” key to store the new set.
Press “CANCEL” key to exit;
Whether allow the modification of Press “L/GAL” key, enter into the “Electronic Total
electronic volume and sales amount Modified Enable” menu;
Electronic Total total. Use ↑ or ↓(or press digital number“1” or “2”) to set
45 1:ON whether enable the totalizer modification.
Modified Enable
2:OFF Press “L/GAL” key to update the new set.
Default:1:ON Press “CANCEL” key to exit;
Modify the password that enters into Press “L/GAL” key, enter into the “Modify Password Of
Level 4. level 4” menu;
The password needs to be entered twice Input new password the press “L/GAL” key to confirm.
to confirm. If the password enter is Re-input the password again.
Modify Password of
46 inconsistent, the keypad display will Press “L/GAL” key to update the new password.
Level 4
show ‘Password ERR!’, and you can Press “CANCEL” key to exit;
input the password again.
- 35 -
Fig 2.3(b) Diagram for F1V03 Control board
2.4The transaction limit
The transaction limit is based on counting of the calculator operation time. Here the I2 calculator
has 2 types of transaction limit for the fueling period.
This limit can be set by the supplier of the technology for the petrol station. When operation value
reaches the pre-set limit, the calculator’s price display and keypad display will show error code
e.g: here are 2 nozzles, we preset 100RMB, the current sales totals and volume totals are as bellow:
nozzle 1: Sales tot: 42949660.00, Volume tot: 8456242.55L; price: 7.50RMB/L;
SANKI CONFIDENTIAL AND PROPRIETARY
- 36 -
nozzle 2: Sales tot: 207478.50, Volume tot: 42949665.00L; price: 7.50 RMB/L;
For nozzle 1:
Sales tot: 42949660.00+100=42949660.00+12.95+87.05=87.05;
Volume tot: 8456242.55+100/7.50=8456255.88;
For nozzle 2:
Sales tot: 207478.50+100=207578.50;
Volume tot: 42949665.00+100/7.50=42949665.00+13.3=42949665.00+7.95+5.35=5.35;
- 37 -
3. Technical Data
- 38 -
4. Diagnostics
4.1 Error message
When an error is detected:
Delivery is stopped(on one or both sides depending on the error type)
Error code is displayed on the unit price display (3rd line of the side display), where unit
price is normally displayed. The error displayed in the form “Xxx” where “X” stands for
the digital of “1” and “2”, “xx” stand for the error code item(from 01 to 13)
When this error occurs, the user should consult the producer or the local agency. To recover the
dispenser from this type of error, please refer to the related solutions.
When this error occurs, the user should stop fueling immediately, and consult the producer or the
local agency. To recover the dispenser from this type of error, please refer to the related solutions.
- 39 -
d. Lift nozzle again while refueling at the same When lifting one nozzle for fueling ,
side; the other nozzle is forbidden for lifting
up at same side .
Two keypad displays show alarm code and source Use the multi-meter to measure the
of error, two unit price boards show alarm button battery(”+” and “-“) which
code“102” and price alternately, the speaker installed on the mainboard, if it is less
102 alarms, it allows to lift nozzle for fueling, but will than 1.7VDC, replace a button battery,
fail to transmit data to POS by accidental power the battery module: CR2032(3V)
Battery off:
RAM It fails to read “Battery RAM Error” while power Attention:
Error on to initialize Make sure power on all time while
replacing the button battery.
a. Read the battery backup memory failure.
b. Power down memory failure
Two keypad displays show alarm code and source Put back nozzle to nozzle boot, then set
of error, two unit price boards show alarm the correct working days in level 3,
code(103) and price alternately, the speaker alarms, item 3;(default value is 0)
103 it’s forbidden to fuel;
While prepare to lift nozzle for refueling, it detect Set the maximum working days for the
Out of “Out of Date” fuel dispenser;
Date Range: 0-365;
The service is over the appointed work days. 0: No limit;
The setting value function validate for
all nozzles;
Two keypad displays show alarm code and source Power off and on again, sometimes
104 of error, two unit price boards show alarm it will release the blocking issue.
code(104) and price alternately, the speaker alarms,
it’s forbidden to fuel; Check or change the hardware if
Read While lift nozzle for refueling, it detects “Read
Flash necessary. Need service.
Flash 45DB041 Error”;
Error
45DB041Flash reading error
Two keypad displays show alarm code and source Power off and on again, sometimes
105 of error, two unit price boards show alarm it will release the blocking issue.
code(105) and price alternately, the speaker alarms,
it’s forbidden to fuel; Check or change the hardware if
Write While lift nozzle for refueling, it detects “Write
Flash necessary. Need service.
flash 45DB041 Error”
Error
45DB041Flash Write error
Two keypad displays show alarm code and source Power off and on again, sometimes
106 of error, two unit price boards show alarm it will release the blocking issue.
code(106) and price alternately, the speaker alarms,
it’s forbidden to fuel; Check or change the hardware if
Read While lift nozzle for refueling, it detects “Read
E2PROM necessary. Need service.
E2PROM 24LC16 Error”;
Error
24LC16 I2C memory reading error
Two keypad displays show alarm code and source Power off and on again, sometimes
107 of error, two unit price boards show alarm it will release the blocking issue.
code(107) and price alternately, the speaker alarms,
Write it’s forbidden to fuel; Check or change the hardware if
E2PROM While lift nozzle for refueling, it detects necessary. Need service.
Error “WriteE2PROM24LC16Error”
24LC16 I2C memory write error
SANKI CONFIDENTIAL AND PROPRIETARY
- 40 -
Keypad display in the same side show alarm code Put back nozzle and press cancel
and source of error, the unit price boards in the button to clear the alarm code.
108 same side show alarm code(108) and price
alternately, the speaker alarms; Set new coefficient in level 4;
No While lift nozzle for refueling, it detects “No ( the default coefficient value is
Coefficient coefficient” 1000)
Flowmeter coefficient is over limit.
Unit price boards in same side show alarm Check the cable connection from main
code(109) and price alternately, the speaker alarms, board to keypad, maintain or replace it
109
it’s forbidden to refuel this side; if damaged;
while lift nozzle for refueling, it detects
KeyBoard Check the keypad, maintain or replace
“KeyBoard Error”
Error it if damaged.
Keypad or the connection failure.
The related keypad display show alarm code and Check the cable connected from main
source of error, two unit price boards show alarm board to control board, maintain or
110 code(110) and price alternately, the speaker alarms, replace it if damaged;
it’s forbidden to refuel;
While lift nozzle for refueling, it detects
CtrlBoard “CtrlBoard Error” Check the control board, maintain or
Error replace it if damaged.
Control board or the connection failure.
Non-refueling status: two keypad displays show While connecting to FMS, set the
alarm code and source of error, two unit price communication mode to Online mode;
boards show alarm code(111) and price alternately,
the speaker alarms, it’s forbidden to fuel; Please check the work mode, the back
office POS or MIS or FCC system,
Under refueling status: stop driving signals while check the cable and connections, make
111
refueling, two keypad displays show alarm code sure the connections first. Change the
and source of error, two unit price boards show main board if necessary.
Off Line alarm code(111) and price alternately, the speaker
alarms, but no affect for the next refueling
- 41 -
The keypad display of this side shows alarm and Lift up nozzle but not find ID card, put
source of error, the unit price board shows alarm back the nozzle and the alarm cleared.
114 code(114) and price alternately, the speaker alarms,
forbid to fuel this side;
NO ID While lift nozzle for refueling, it detects “No ID
Card Card”
NO ID Card
The keypad display of this side shows alarm and when the dispenser read ID card error,
source of error, the unit price board shows alarm the following operation will clear the
code(115) and price alternately, the speaker alarms, alarm:
115 forbid to fuel this side;
While lift nozzle for refueling, it detects “Read ID 1:Swap the card again and read card
Read ID Card Error” success;
Card
Error Read ID Card Error 2:Press "Cancel" key;
- 42 -
Survey of errors series Ⅱ reported
- 43 -
the first and second times do not alarm, the
third overshoot more than 0.1 liter then
alarm.
Keypad display of this side shows alarm Check the cable which connect from pulser to
code and source of error, the unit price board main board;
205 on same side shows alarm code(205) and
price alternately, the speaker alarms; If it happens repeatedly or frequently, then need
During refueling, it will detects and show to fix or replace the pulser.
Pulser “Pulser Error”
Error
There is something wrong with the Pulser or
connection.
Keypad display of this side shows alarm Check the cable which connect from M-counter
code and source of error, the unit price board to Ctrlboard(KZB)
206 on same side shows alarm code(206) and
price alternately, the speaker alarms; Maintain or replace M-counter.
During refueling, it will detects and show
Magnetic “Magnetic Error”
Error
There is something wrong with the Magnetic
counter.
The keypad display of this side shows alarm Check the cable which connect from pulser to
and source of error, the unit price board Ctrlboard(KZB)
shows alarm code(207) the speaker alarms:
207 Maintain or replace the malfunction pulser
While lift nozzle for fueling with two pumps
1st / 2nd two flow meters, one of the pulser failed to Note: Contact the authorized service provider
Pulser transmit the correct pulse to the mainboard immediately when this error happens. And the
ERR during fueling process, and the solenoid dispenser is prohibited to fuel unless this alarm
valve will be closed after 20s delivery and code has been cleared in Item 327: Clear
dispenser alarms. Alarmcode Saved in Flash.
The keypad display of this side shows alarm Correct the sensor wiring or solenoid valve
and source of error, the unit price board wiring.
208 shows alarm code(208) the speaker alarms.
Cable
Connect In Calibrate Dual Meter model, only one
Error flowmeter can work. And the dispenser will
alarm if there is something wrong with the
wiring connection.
- 44 -