This document provides technical specifications and installation instructions for the MaxxECU PWM module. The module operates from 8-24V, can handle intermittent loads up to 60A and continuous loads up to 50A. It is waterproof and protected from overloads. The module controls electric devices like fuel pumps via CAN communication and only works with MaxxECU engine management systems. Installation guidelines recommend placing the module close to controlled devices and away from heat sources, with CAN wiring following specifications to prevent interference over maximum 25m lengths.

Uploaded by

Manuel Serrano
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
682 views2 pages

MaxxECU PWM CAN Module - Manual-En

This document provides technical specifications and installation instructions for the MaxxECU PWM module. The module operates from 8-24V, can handle intermittent loads up to 60A and continuous loads up to 50A. It is waterproof and protected from overloads. The module controls electric devices like fuel pumps via CAN communication and only works with MaxxECU engine management systems. Installation guidelines recommend placing the module close to controlled devices and away from heat sources, with CAN wiring following specifications to prevent interference over maximum 25m lengths.

Uploaded by

Manuel Serrano
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Dynotuning Engine Management Motorsport 2016-10-19

MaxxECU PWM module


Technical Data:
Supply voltage: 8-24V
Max intermitent load: 60A
Max continous load: 50A
Operating temperature: -40 till 125C
Waterproof and protected from overload and high tempera-
tures. Controls electric motors (fuel pump, fan, water pump,
lights, etc.). The PWM module is controlled via CAN and does
only work with MaxxECU EMS..
MTune controllabe load settings between 0 and 100%.
Be sure to place the module as close to the load as possible
to avoid interference. Do not mount the module close to heat
sources such as exhaust components.

CAN-bus wiring

MaxxECU

Only use twisted 0.5mm2 (20AWG) wire for CANbus.


CAN module

CAN H CAN-bus
Maximum length of the CAN bus = 25m (82ft)
CAN L CAN-bus
Max
100mm (4”)

Maximum distance of Other CAN modules


100mm (4”) between
the branch on the bus
and the module to
avoid interference/
noise and loss of signal
integrity.
Use the shortest
The CAN bus is always terminated with a 120ohms
branches possible to
resistor (supplied).
connected devices
Cable lengths over 3m (10ft) are not in need of the
from the main line CAN
resistor.
bus.

When only one CAN


module is connected,
there are no restric-
tions regarding joint
placement.
Maxxtuning AB, Sweden - www.maxxtuning.eu - [email protected]
Wirings

Red: +12v

Relay controlled by the ignition switch.

Fuse

Brown: GND

Yellow: +12v OUT


- +
Battery
MaxxECU PWM module

L
L: Load (motor, light etc.)
L Connect in parallel if multiple
loads.

Change module ID (only REV 3 units)

ID = 1 (standard)

ID = 2

ID = 3

ID = 4