0% found this document useful (0 votes)
2K views17 pages

USR TCP232 410s User Manual

Conversor ethernet/serial

Uploaded by

GESELL CABEZAS
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2K views17 pages

USR TCP232 410s User Manual

Conversor ethernet/serial

Uploaded by

GESELL CABEZAS
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 17

USR-TCP232-410s User Manual Technical Support: h.usriot.

com

USR-TCP232-410s User Manual

File Version: V1.1.1.02

Jinan USR IOT Technology Limited 1


USR-TCP232-410s User Manual Technical Support: h.usriot.com

Contents
USR-TCP232-410s User Manual......................................................................................................................... 1
Features .................................................................................................................................................................... 3
1. Get Start ................................................................................................................................................................ 4
1.1. Application Diagram............................................................................................................................... 4
1.2. Hardware Design..................................................................................................................................... 5
1.2.1. Hardware Dimensions ................................................................................................................ 5
1.2.2. LED.................................................................................................................................................. 5
2. Product Functions .............................................................................................................................................. 6
2.1. Basic Functions ........................................................................................................................................ 6
2.1.1. Static IP/DHCP .............................................................................................................................. 6
2.1.2. Reset to default settings .............................................................................................................. 7
2.2. Socket functions ...................................................................................................................................... 7
2.2.1. TCP Client ...................................................................................................................................... 7
2.2.2. TCP Server ..................................................................................................................................... 7
2.2.3. UDP Client ..................................................................................................................................... 8
2.2.4. UDP Server .................................................................................................................................... 9
2.2.5. HTTP Client ................................................................................................................................... 9
2.2.6. WebSocket ................................................................................................................................... 10
2.3. Serial port................................................................................................................................................ 11
2.3.1. Serial port basic parameters .................................................................................................... 11
2.3.2. VCOM Application ....................................................................................................................... 11
2.3.3. Flow Control ................................................................................................................................. 11
2.3.4. Serial package methods ............................................................................................................. 11
2.3.5. Baud rate synchronization ........................................................................................................ 11
2.4. Features................................................................................................................................................... 12
2.4.1. Identity packet function ............................................................................................................ 12
2.4.2. Heartbeat packet function ....................................................................................................... 12
2.4.3. Non-persistent connection ...................................................................................................... 12
2.4.4. Modbus gateway......................................................................................................................... 12
2.4.5. Network printing........................................................................................................................ 13
2.4.6. Editable Web Server ................................................................................................................... 13
3. Parameter Setting............................................................................................................................................. 14
3.1. Setup software........................................................................................................................................ 14
3.2. Web Server ............................................................................................................................................. 14
3.3. AT command .......................................................................................................................................... 15
3.3.1. Serial AT command.................................................................................................................... 15
3.3.2. Network AT command ............................................................................................................... 15
4. Contact Us........................................................................................................................................................... 17
5. Disclaimer .......................................................................................................................................................... 17
6. Update History .................................................................................................................................................. 17

Jinan USR IOT Technology Limited 2


USR-TCP232-410s User Manual Technical Support: h.usriot.com

Features
◼ 10/100Mbps Ethernet interface and support Auto-MDI/MDIX.
◼ Support TCP Server, TCP Client, UDP Client, UDP Server, HTTP Client.
◼ Support configuring through Web Server
◼ Support RS232 and RS485 and they can work independently.
◼ Support RTS/CTS hardware flow control and Xon/Xoff software flow control.
◼ Support USR-VCOM.
◼ Support Modbus Gateway.
◼ Support serial port baud rate 600bps~230.4K bps; support None, Odd, Even, Mark, Space parity way.
◼ Support Static IP or DHCP.
◼ Support Websocket function.
◼ Support Reload button to reset to default settings by hardware way.
◼ Support Keep-alive.
◼ Support timeout restart function and timeout reconnect function.

Jinan USR IOT Technology Limited 3


USR-TCP232-410s User Manual Technical Support: h.usriot.com

1. Get Start

Product link:
https://www.usriot.com/products/modbus-serial-to-ethernet-converter.html
Setup software:
https://www.usriot.com/support/downloads/usr-tcp232-m4k3-setup-software.html

Figure 1 Download Page


If user has any question, please submit it back to customer center: h.usriot.com

1.1. Application Diagram

Figure 2 Application diagram

Jinan USR IOT Technology Limited 4 www.usriot.com


USR-TCP232-410s User Manual Technical Support: h.usriot.com

1.2. Hardware Design

1.2.1. Hardware Dimensions

Figure 3 Hardware dimensions

1.2.2. LED
LED Status
Light: Power on
POWER
Off: Power off
Blink: Working normally
WORK
Off or light: Not working normally
Blink: Sending data to serial(RS232)
232TX
Off: No data sending to serial(RS232)
Blink: Receiving data from serial(RS232)
232RX
Off: No data receiving from serial(RS232)
Blink: Sending data to serial(RS485)
485TX
Off: No data sending to serial(RS485)
Blink: Receiving data from serial(RS485)
485RX
Off: No data receiving from serial(RS485)
Figure 4 LED

Jinan USR IOT Technology Limited 5 www.usriot.com


USR-TCP232-410s User Manual Technical Support: h.usriot.com

2. Product Functions

This chapter introduces the functions of USR-TCP232-410s as the following diagram shown, you can get an
overall knowledge of it.

Socket A TCPS/TCPC/UDPS/UDPC/HTTPD Client 1

Serial
USR Identity
port CLOUD
Keep-Alive
Packet
packaging

Socket B TCPC/UDPC 1

Serial Heartbeat packet Network Heartbeat packet

Serial Serial
Port Network
Device port Serial port
Webserver
Network data 1
packaging transmission
Websocket

Serial AT command Parameter Query/Set

AT Command Mode

ModbusTCP Gateway
Modbus Gateway

Figure 5 Product Functions diagram

2.1. Basic Functions

2.1.1. Static IP/DHCP


There are two ways for module to get IP address: Static IP and DHCP.

Static IP: Default setting of module is Static IP and default IP is 192.168.0.7. When user configures module in Static
IP mode, user need set IP, subnet mask and gateway and must pay attention to the relation among IP, subnet mask
and gateway.

DHCP: Module in DHCP mode can dynamically get IP, Gateway, and DNS server address from Gateway Host. When
user connects 410s directly to PC, module can’t be set in DHCP mode. Because common computer does not have
the ability to assign IP addresses.
Jinan USR IOT Technology Limited 6 www.usriot.com
USR-TCP232-410s User Manual Technical Support: h.usriot.com

2.1.2. Reset to default settings


Hardware: Power off the 410s and press Reload button, then power on the 410s and keep pressing Reload button
over 5 seconds can reset to default settings.

Software: User can also reset to default settings through setup software for 410s.

AT command: User can send AT+RELD to reset to default settings.

2.2. Socket functions

410s supports dual sockets mode. Socket A supports TCP Server, TCP Client, UDP Server, UDP Client and HTTP
Client. Socket B supports TCP Client and UDP Client.

2.2.1. TCP Client

Figure 6 TCP Client


TCP Client provides Client connections for TCP network services. TCP Client device will connect to server to
realize data transmission between the serial port device and server. According to the TCP protocol, TCP Client has
connection/disconnection status differences to ensure reliable data transmission.

TCP Client mode supports Keep-Alive function: After establishing connection, 410s will send Keep-Alive package
in every 15 second to check TCP connection and 410s will disconnect and reconnect to server if any connection
exception occurs. TCP Client mode also supports baud rate synchronization, USR Cloud and Modbus gateway.

410s works in TCP Client mode needs connect to TCP Server and needs set the parameter: Remote IP/Port. 410s
works in TCP Client won’t accept other connection request except target server and will access server with
random local port if configuring local port to 0.

2.2.2. TCP Server

Jinan USR IOT Technology Limited 7 www.usriot.com


USR-TCP232-410s User Manual Technical Support: h.usriot.com

Figure 7 TCP Server


410s works in TCP Server mode will listen network connections and build network connections, commonly be
used for communication with TCP clients on a LAN. According to the TCP protocol, TCP Server has
connection/disconnection status differences to ensure reliable data transmission.

410s works in TCP Server mode will listen local port which user set and build connection after receiving
connection request. Serial data will be sent to all TCP Client devices connected to 410s in TCP Server mode
simultaneously.

410s works in TCP Server mode supports 8 client connections at most. 410s also supports Keep-Alive function,
baud rate synchronization and Modbus gateway.

2.2.3. UDP Client

Figure 8 UDP Client


UDP transport protocol provides simple and unreliable communication services. No connection connected
/disconnected. User only needs to configure Remote IP/Port then can realize data transmission.

Jinan USR IOT Technology Limited 8 www.usriot.com


USR-TCP232-410s User Manual Technical Support: h.usriot.com
In UDP Client mode, 410s will only communicate with Remote IP/Port. If data don’t from Remote IP/Port, it won’t
be received by 410s.

In UDP Client mode, if user configure Remote IP to 255.255.255.255, 410s can achieve UDP broadcast to all
network segment and receive broadcast data. User can also configure Remote IP to xxx.xxx.xxx.255 to realize UDP
broadcast in same network segment.

2.2.4. UDP Server

Figure 9 UDP Server


In UDP Server mode, 410s will change Remote IP every time after receiving UDP data from a new IP/Port and will
send data to latest communication IP/Port.

2.2.5. HTTP Client

Figure 10 HTTP Client

Jinan USR IOT Technology Limited 9 www.usriot.com


USR-TCP232-410s User Manual Technical Support: h.usriot.com

data=ABC GET/1.php?data=ABC HTTP/1.1


Host: www.usr.cn:80
User-Agent: Mozilla/4.0
Connection: close

Serial Device 410s HTTP Server


HTTP/1.1 200 OK
Data: Wed, 24 Jun 2015 04:08:35 GMT
Server.Apache/2.0.63(Win32)PHP/5.2.4
ABC X-Powered-By: PHP/5.2.14
Cache-Control: max-age=31104000
Expires: Fri, 18 Aug 2017 03:25:47 GMT
Content-Length: 3
Connection: close
Content-Type: text/html

ABC

Figure 11 HTTP Client


In HTTP Client mode, 410s can achieve data transmission between serial port device and HTTP server. User just
needs to configure 410s in HTTP Client and configure the HTTP header, URL and some other related parameters,
then can achieve data transmission between serial port device and HTTP server and don’t need care about the
HTTP format of data.

2.2.6. WebSocket

Figure 12 WebSocket
WebSocket function can achieve real-time interaction between RS232 interface and Web Server and display user
data on Web Server.

Jinan USR IOT Technology Limited 10 www.usriot.com


USR-TCP232-410s User Manual Technical Support: h.usriot.com

2.3. Serial port

2.3.1. Serial port basic parameters


Parameters Range
Baud Rate 600~230.4Kbps
Data Bits 5, 6, 7, 8
Stop Bits 1, 2
Parity Bits None, Odd, Even, Mark, Space
Figure 13 Serial port basic parameters

2.3.2. VCOM Application

Figure 14 VCOM application


User can download VCOM software from:
https://www.usriot.com/support/downloads/usr-vcom-virtual-serial-software.html.

Through this software user can set up connection between 410s and virtual serial to solve the problem that
traditional equipment PC software used in serial port communication way.

2.3.3. Flow Control


410s supports hardware flow control way ( RTS/CTS, only take effect in RS232 mode ) and software flow control
way Xon/Xoff.

2.3.4. Serial package methods


For network speed is faster than serial. Module will put serial data in buffer before sending it to network. The data
will be sent to network side as data package. There are 2 ways to end the package and send package to network
side - Time Trigger Mode and Length Trigger Mode.

⚫ 410s serial package time: Default is 4 bytes sending time, range from 0 to 255.
⚫ 410s serial package length: Default is 1460 bytes, range from 0 to 1460.

2.3.5. Baud rate synchronization


When module works with USR devices or software, serial parameters will change dynamically according to
network protocol. User can modify serial parameters by sending data conformed to specific protocol via network.
It is temporary, after restarting DTU, the parameters will back to original parameters.

Jinan USR IOT Technology Limited 11 www.usriot.com


USR-TCP232-410s User Manual Technical Support: h.usriot.com

2.4. Features

2.4.1. Identity packet function

Figure 15 Identity Packet application diagram

Identity packet is used for identifying the device when 410s works as TCP client/UDP client. There are two
methods to send identity packet.
⚫ Identity packet will be sent after connection is established.
⚫ Identity packet will be added on the front of every data package.

Identity packet can be MAC address or user editable identity packet. User editable identity packet should less than
40 bytes.

2.4.2. Heartbeat packet function


Heartbeat packet: 410s will output heartbeat packet to serial side or network side periodic. User can configure
the heartbeat packet data and sending interval. Serial heartbeat packet can be used for polling Modbus data.
Network heartbeat packet can be used for showing connection status and keeping the connection (only take effect
in TCP/UDP Client mode).

2.4.3. Non-persistent connection


410s support non-persistent connection function in TCP Client mode. When 410s adopts this function, 410s will
connect to server and send data after receiving data from serial port side and will disconnect to server after
sending all the data to server and no data from serial port side over 3s.

2.4.4. Modbus gateway


Modbus gateway includes: Modbus RTU transparent transmission, Modbus ASCII transparent transmission,
Modbus RTU<=>Modbus TCP protocol conversion, Modbus polling and serial port query.

Modbus RTU<=>Modbus TCP: Set 410s in TCP Server or TCP Client mode, then user can set 410s with Modbus

Jinan USR IOT Technology Limited 12 www.usriot.com


USR-TCP232-410s User Manual Technical Support: h.usriot.com
RTU<=>Modbus TCP function. Data transmission diagram as follow:

Figure 16 Modbus RTU<=>Modbus TCP

Modbus polling: 410s support Modbus polling function.

Figure 17 Modbus polling

2.4.5. Network printing


The network printing function is similar to the printer server. Through the existing printing driver, it can be
modified slightly and realize the network printing function by the original serial printer.

2.4.6. Editable Web Server


410s supports modifying the Web Server based on template according to needs, then using related tool to upgrade.
If user has this demand can contact to our salespersons for Web Server source and tool.

Jinan USR IOT Technology Limited 13 www.usriot.com


USR-TCP232-410s User Manual Technical Support: h.usriot.com

3. Parameter Setting

There are three ways to configure USR-TCP232-410s. They are setup software, Web Server and AT command.

3.1. Setup software

User can download setup software from


https://www.usriot.com/support/downloads/usr-tcp232-m4k3-setup-software.html. When user want to
configure the 410s by setup software, user can run setup software, search 410s in same LAN and configure the
410s as follow:

Figure 18 Setup software


After researching 410s and clicking 410s to configure, user need log in with user name and password. Default
user name and password both are admin. If user keep the default parameters, it is not necessary to log in.

3.2. Web Server

User can connect PC to 410s through LAN port and enter Web Server to configure.

Web Server default parameters as follow:


Parameter Default settings
Web server IP address 192.168.0.7
User name admin
Password admin
Figure 19 Web server default parameters

Jinan USR IOT Technology Limited 14 www.usriot.com


USR-TCP232-410s User Manual Technical Support: h.usriot.com
After firstly connecting PC to 410s, user can open browser and enter default IP 192.168.0.7 into address bar, then
log in user name and password, user will enter Web Server. Web Server screenshot as follow:

Figure 20 Web Server

3.3. AT command

We have specific user manual for AT commands.

3.3.1. Serial AT command


In work mode, user can enter AT command mode and send AT commands to module to configure the module. For
entering AT command mode, please refer to this FAQ:
https://www.usriot.com/support/faq/enter-serial-command-mode.html.

3.3.2. Network AT command


Network AT command is to send a search keyword by broadcast, then set the parameters in a single broadcast
way(If user want to use network AT command, module and PC which send the network AT command must in
same network segment). Default keyword is WWW.USR.CN and default port number is 48899. If user enter
network AT command mode but don’t send any command over 30 seconds, module will exit network AT command
mode. User can enter network AT command mode as follow way:

Jinan USR IOT Technology Limited 15 www.usriot.com


USR-TCP232-410s User Manual Technical Support: h.usriot.com

Figure 21 Network AT Command

Jinan USR IOT Technology Limited 16 www.usriot.com


USR-TCP232-410s User Manual Technical Support: h.usriot.com

4. Contact Us

Company: Jinan USR IOT Technology Limited

Address: Floor 11, Building 1, No. 1166 Xinluo Street, Gaoxin District, Jinan, Shandong, 250101, China

Web: www.usriot.com

Support: h.usriot.com

Email: [email protected]

Tel: 86-531-88826739/86-531-55507297

5. Disclaimer

This document provides the information of USR-TCP232-410s products, it hasn’t been granted any intellectual
property license by forbidding speak or other ways either explicitly or implicitly. Except the duty declared in sales
terms and conditions, we don’t take any other responsibilities. We don’t warrant the products sales and use
explicitly or implicitly, including particular purpose merchant-ability and marketability, the tort liability of any
other patent right, copyright, intellectual property right. We may modify specification and description at any time
without prior notice.

6. Update History

2017-11-06 V1.1.1.01 established based on Chinese version V1.1.1.


2018-06-05 V1.1.1.02 updated. Modified 2.2.6. WebSocket. Updated web page link and some pictures. Modified
some words to standard terms. Corrected grammar mistakes. Optimized whole manual format.

Jinan USR IOT Technology Limited 17 www.usriot.com