0% found this document useful (0 votes)
213 views6 pages

I1-Wiring Diagrams

The document discusses different types of wiring diagrams for outputs and sensors. It provides diagrams and descriptions of various output configurations including DC, AC, optoelectronic sensors, and electromechanical/electronic magnetic switches. Abbreviations for cable colors are also defined.

Uploaded by

Parvej Singla
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
213 views6 pages

I1-Wiring Diagrams

The document discusses different types of wiring diagrams for outputs and sensors. It provides diagrams and descriptions of various output configurations including DC, AC, optoelectronic sensors, and electromechanical/electronic magnetic switches. Abbreviations for cable colors are also defined.

Uploaded by

Parvej Singla
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Wiring Diagrams

Types of Output DC 1 PNP output NPN output


(circuit schematic) (circuit schematic)

Cable colour abbreviations

BN = Brown
BU = Blue
BK = Black (switch output)

3) PNP programmable
1) PNP normally-open contact 2) PNP normally-closed contact The PNP NO contact 1) or PNP NC contact 2)
When actuated, a PNP transistor applies the When actuated, a PNP transistor disconnects function can be selected by means of a built-in
output to positive. the output from positive. changeover switch.

6) NPN programmable
4) NPN normally-open contact 5) NPN normally-closed contact The NPN NO contact 4) or NPN NC contact 5)
When actuated, a NPN transistor applies the When actuated, an NPN transistor disconnects function can be selected by means of a built-in
output to negative. the output from negative. changeover switch.

7) PNP/NPN programmable 9) Push-pull programmable


Two built-in changeover switches are used to When actuated, the output changes from negative
select between PNP or NPN switching and between 8) NAMUR to positive or, selectable with a built-in changeover
NC or NO function. Current change to DIN EN 60947-5-6 switch, from positive to negative.

156
Types of Output DC 2 DC 2-wire DC 4-wire
(circuit schematic) (circuit schematic)

Cable colour abbreviations

BN = Brown
BU = Blue
BK = Black (switch output)
WH = White (switch output)

3) NC/NO contact programmable


DC 2-wire
1) NO contact DC 2-wire 2) NC contact DC 2-wire The NO contact 1) or NC contact 2) function can be
When actuated, the contacts are bridged. When actuated, the contacts are disconnected. selected by means of a built-in changeover switch.

4) Changeover output DC (antivalent) 5) Changeover output DC (antivalent)


PNP 4-wire NPN 4-wire
When actuated, the positive operating voltage is When actuated, the negative operating voltage is
alternatively applied to one of the two outputs. alternatively applied to one of the two outputs.

157
Wiring Diagrams

Types of Output AC 1 AC 2-wire AC 3-wire


(circuit schematic) (circuit schematic)

Cable colour abbreviations

BN = Brown
BU = Blue
BK = Black

3) NC/NO contact programmable


1) NO contact AC 3-wire 2) NC contact AC 3-wire AC 3-wire
When actuated, a thyristor connected across When actuated, a thyristor connected across The AC NO contact 1) or AC NC contact 2)
a rectifier bridge applies the operating voltage a rectifier bridge disconnects the operating function can be selected by means of a built-in
to the output. oltage from the output. changeover switch.

6) NC/NO contact programmable


5) NC contact AC 2-wire AC 2-wire
4) NO contact AC 2-wire When actuated, a thyristor connected across The AC NO contact 4) or AC NC contact 5)
When actuated, a thyristor connected across a recti- a rectifier bridge disconnects the load from the function can be selected by means of a built-in
fier bridge applies the load to the operating voltage. operating voltage. changeover switch.

BN
L1
BU
N
GY
N.C.
BK
C.
WH N.O.

7) AC relay output
With adjustable pickup delay

158
Optoelectronic
Sensors 1

Transmitter PNP NPN


Light activated or dark activated Light activated or dark activated

Transmitter PNP antivalent NPN antivalent


Light activated and dark activated Light activated and dark activated

Operating reserve

hysteresis surplus
detection
signal
strength

diagnostic
fault
output
(green LED)
output
(yellow LED)

Transmitter PNP
Light activated and operating reserve output

159
Wiring Diagrams

Optoelectronic
Sensors 2

Transmitter AC 3-wire NPN or PNP

NPN or PNP Relay output Relay output

DIN connector

160
Type of Contact

Electric Loading Capacity


of Reed Contacts AC/DC

Contact type ID Power Voltage Current


R 3 VA 28 V 0.25 A
X 5 VA 100 V 0.25 A
B 10 VA 250 V 0.5 A
Y 10 VA 100 V 0.5 A
A 20 VA 250 V 0.5 A
K 30 VA 250 V 0.5 A
H 60 VA 250 V 1.0 A
L 60 VA 250 V 1.0 A
M 80 VA 250 V 1.0 A
F 100 VA 250 V 3.0 A
G 250 VA* 250 V 5.0 A*
P 250 VA* 250 V 5.0 A*

* Maximum make current for the duration of 2 ms


2.5 A; 100 W/VA in continuous operation

Wiring Diagrams Wiring Diagrams


Electromechanical Magnetic Switches Electronic Magnetic Switches

contact
NC contact, PNP

NO contact
NO contact,
PNP/PNP, bistable

Changeover
contact

NC contact, NPN
Bistable
ON-OFF

Bistable NO contact, NPN


Changeover
contact

161