0% found this document useful (0 votes)
2K views2 pages

ITP Check List For Metal Deck Installation

The document is an inspection and test plan for metal deck installation and plumbing work at the Masinloc Power Plant Expansion Project. It outlines 7 items to inspect for the metal deck installation, including checking the approval of materials, installer qualification, surface levelness and smoothness, and final acceptance. It also outlines 2 items to inspect for plumbing work repair, including paint repair and touch up of steel structures according to code, and grouting according to product specifications. Inspections will be conducted by various parties at different stages and frequencies, with acceptance criteria defined by project specifications and reference documents.

Uploaded by

Leo Pascual
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2K views2 pages

ITP Check List For Metal Deck Installation

The document is an inspection and test plan for metal deck installation and plumbing work at the Masinloc Power Plant Expansion Project. It outlines 7 items to inspect for the metal deck installation, including checking the approval of materials, installer qualification, surface levelness and smoothness, and final acceptance. It also outlines 2 items to inspect for plumbing work repair, including paint repair and touch up of steel structures according to code, and grouting according to product specifications. Inspections will be conducted by various parties at different stages and frequencies, with acceptance criteria defined by project specifications and reference documents.

Uploaded by

Leo Pascual
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 2

Masinloc Power Plant Expansion Project Doc. No.

Inspection and Test Plan for Metal Deck Installation Rev. No. 0
Page 1 of 1

Inspection Mode
Item Verifying
Activity Reference Documents Acceptance Criteria VPCI AES Frequency Remarks
No. GTC Documents
Site QC
1.0 Raised Flooring
IFC Drawing /
1.1 Check Approval of Materials Applicable Code and Standards Project Specification Relevant Section H R R R
QC Form

Check for the Installer IFC Drawing /


1.2 Project Specification Relevant Section H R R R
Qualification QC Form

Check Materials for IFC Drawing /


1.3 Project Specification Relevant Section H SW SW V
Deformation and Cracks QC Form
Check Surface for Required
IFC Drawing /
1.4 Elevation , Levelness and Project Specification Relevant Section H SW SW V
QC Form
Smoothness

Check Finish Installation for


Squareness, Levelness , IFC Drawing /
1.5 Project Specification Relevant Section H SW SW V
Cleaness and Free from QC Form
Deformation and Damages

Inspection for Final IFC Drawing /


1.6 Project Specification Relevant Section H W W W
Acceptance QC Form
Note: H Hold Point
W Witness Point
LEGEND SW Spot Witness
R Review
V Surveillance
Masinloc Power Plant Expansion Project Doc. No. 0-WD800-CA250-00302
Inspection and Test Plan for Plumbing Work Rev. No. A
Page 4 of 4

Inspection Mode
Item Verifying
Activity Reference Documents Acceptance Criteria VPCI AES Frequency Remarks
No. GTC Documents
Site QC
7.0 Repair

AISC 303code of Standard


Paint Repair / Touch Up / Touch-up Paint
Practice for Steel Building and
7.1 Painting of Steel Structure As per Project Specification H V W V 100% Inspection
Bridges Sec 7.17 /
Bolt Connection Record
Work precedure to be submitted

Relevant grout material QC Inspection


7.2 Grouting As per Product Specification H H SW V 100%
specification Report

Note: H Hold Point


W Witness Point