Key Benefits: Monitoring and Metering User Interface
Key Benefits: Monitoring and Metering User Interface
3-phase true RMS measurements of voltage, current & power Large bright blue backlit LCD graphical display for values,
THD and individual Current and Voltage harmonics up to 31st relay status and graphical load display.
order for facility wide power quality monitoring Graphical diagram of voltage and current unbalance
Bidirectional energy measurement with min/max for electrical Economical design, small footprints fits in 90x90mm cut out
parameters Digital outputs used as KYZ pulse outputs for energy informa-
Advanced control features for relay activation at user tion to PLC, RTU and other non digital communication devices
definable set points Digital outputs used as alarm 15
Open Modbus protocol over RS 485 allows easy integration to
EnerVista or third party systems
APPLICATIONS
Ideal circuit monitoring for main feeds, branch circuits, gensets Pulse energy outputs to PLCs for load shedding
and equipment Panel mount low and medium voltage applications
Programmable set-point for alarms and control
FEATURES
Monitoring and Metering User Interface
True RMS measurement of over 80 electrical parameters User programmable Modbus communication over RS 485
Measures 3-phase real-time amps, volts, power, energy, power Form A control relays with programmable set-points
factor and frequency KYZ pulse output for PLC and other device interfaces
Provides remote status when used with PC software
1
EPM 5500P Power Metering System
Metering
electrical energy, power, demand as well Reactive Power Q1,Q2,Q3,Qsum
as voltage, current and other parameters Apparent Power S1,S2,S3,Ssum
through an easy to use interface. As an Power Factor PF1,PF2,PF3,PF
option, the unit also provides control, Frequency Frequency
events and alarms with time stamps along Energy Ep_imp,Ep_exp,Ep_total,Ep_net
Energy
with digital outputs. Additional features Reactive Energy Eq_imp,Eq_exp,Eq_total,Eq_net
include Total Harmonic Distortion (THD) as Demand Dmd_P,Dmd_Q,Dmd_S
well as individual harmonics to the 31st Voltage Unbalance U_unbl
order. Factor
Current Unbalance I_unbl
The EPM 5500P can be used to replace Factor
multiple traditional analog and digital mul- Voltage THD THD_V1,THD_V2,THD_V3,
Power Quality
Monitoring
User Interface
Display metering data
Energy Level
www.GEMultilin.com
2
EPM 5500P Power Metering System
Metering and Measurements industrial PLCs and commercial energy- Apparent Power - per phase and sum
management systems. Integration into Power Factor - per phase and sum
The EPM 5500P is a true RMS multifunction
existing systems is simple and quick.
meter and an ideal choice when continuos Voltage and current unbalance
monitoring of electrical parameters is Demand - Power, Apparent and Reactive
required. In addition to realtime metering, Options Advanced
the standard meter also provides voltage,
current and total harmonic distortion for
Measurement Features KYZ Pulse Output Options:
each phase. The measured accuracy of The two digital outputs (DO) can be select-
voltage and current is 0.2%, power and Control Options: ed as energy pulse outputs. Both the pulse
energy is 0.5% of full scale reading The EPM 5500P includes multiple width and pulse ratio can be programmed
advanced measurement features to sup- as required.
Additionally, voltage and current unbal-
ance is also monitored and displayed as port power analysis and control through
the use of two form A relays. Two digital Any of the two digital outputs can be
graphical phasor diagrams.
outputs can also be used to provide alarm assigned to the following eight energy and
This meter can measure energy in both reactive energy parameters for pulse out-
signals.
directions (import/export) with four quad- put.
rants Kwh and Kvarh with an accuracy of KWh (import, export, net, total)
Up to nine set points can be programmed
0.5%. It can also provide high accuracy KVarh (import, export, net, total)
with specified time limits. If a parameter
energy demand data.
value varies above or below a given set
EPM 5500P measures and displays the point for a programmed time interval, then PC software:
following parameters. an event with a time stamp is generated. The software is used to communicate with
One digital output (DO) can also be activat- the meter for the setting of EPM5500P
Harmonic / Power Quality ed to send a control signal. When the energy, alarm and meter settings. The
Measurements alarming parameter returns to normal, it software tool can be used for real time
With a powerful digital signal processing will be time stamped and logged, provid- monitoring of metered parameters, volt-
capability, the EPM 5500P power meter ing the user with the duration of the age and current harmonics, alarm param-
can be used to monitor power quality. The over/under condition. eters, phase angle parameters and maxi-
meter continuously provides power quality mum/minimum statistical information
analysis for data such voltage and current, Any of the following 34 parameters can be with time stamps.
harmonics up to 31st harmonic as well as programmed to activate 1 DO and gener-
ate an event. 15
Crest Factor, TIF and K Factor. EPM 5500P Guideform
Communication Frequency Specifications
The EPM 5500 is offered with RS485, Volts - per phase, per phase average, For an electronic version of the
Modbus communications. Using its non- phase-phase, phase-phase average EPM 5500 guideform specifications,
proprietary open protocol, the EPM 5500P Currents - per phase, average, neutral please visit: www.GEMultilin.com/ specs,
communicates with most utility RTUs, Power - per phase and sum fax your request to 905-201-2098 or
Reactive Power - per phase and sum email to literature. [email protected].
Features 6
1 7 Part Name Description
3 2
1. Enclosure The EPM 5500P enclosure are made of high
strength anti-combustion engineering plastic
2. Front casing Front casing encloses the LCD and the keypad
3. LCD Display Large bright blue backlight LCD Display
1
4. Key Four keys are used to select display and to set
8 parameters of the meter
5. Input Wiring Terminals Used for Voltage and Current input
6. Auxiliary Wiring Terminals Used for auxiliary power, communication and DI
7. Extension Wiring Terminals Auxiliary I/O wiring terminals
4 5
8. Installation clip When installing, the clips are used for fixing
the meter to the panel
www.GEMultilin.com 3
EPM 5500P Power Metering System
Typical Wiring
3LN, 3CT 3LN, 3CT with 2CT
www.GEMultilin.com
4
EPM 5500P Power Metering System
1 Phase 3 Line
Dimensions dimensions in mm
43.00
96.00
90.00
96.00
38.50
55.00
Terminal
Block
5 I11 4 3 2 1
Vn V3 V2 V1
6 I12
11
A
7 I21 S
12
B
EPM 5500P S
RS-485
8 I22
13
S
9 I31
NC
14
10 I32 15
NC
19
LOAD
20
L
Power supply
85-264VAC 50/60Hz
NC
S1
21
DI1+ DI1- DI2+ DI2- DI3+ DI3- DI4+ DI4-
15 16 17 18
DIGITALINPUTS
100-300VDC
POWER
S2
22
N
DI1+ DI1- DI2+ DI2-
S3
NC
23
25 26 27 28
DIGITALINPUTS
15
DIGITAL INPUTS
S4
EPM 5500P
24
16
G
POWER
17
V+ V-
29 30
DI
31
RELAY OUTPUTS
18
VDI power=15V
32
33
25
DIGITAL INPUTS
34
S1
26
DI1+ DI1- DI2+ DI2- DI3+ DI3- DI4+ DI4-
15 16 17 18
DIGITALINPUTS
R
S2
27
R
DO1+ DO1- DO2+ DO2-
35
DIGITAL OUTPUTS
S3
25 26 2 7 28
28
DIGITALINPUTS
R
36
S4 EPM 5500P
R
DI POWER
37
29
V+
Vaux
30
38
V-
12V<Vaux<30V,I<20mA
Digital input with extemal Aux.Power supply.
R11
or DC
35
35
31
DIGITAL OUTPUTS
DIGITAL OUTPUTS
RELAYOUTPUTS
36
36
R12
32
Vaux Vaux
Out Intermidiate Relay
R13
37
37
33
R14
38
38
34
www.GEMultilin.com 5
EPM 5500P Power Metering System
EPM 5500P Technical Specifications Nominal Input (Supporting 3ph, 2ph, and single phase systems)
www.GEMultilin.com
11.28.05
www.GEMultilin.com
6