Floor Plan
Floor Plan
Floor Plan
Floor Plan
B2 B2 B2 B2 B2
B1 B1 B1 B1 B1
B3
B3
B4
Beams Plan
5#4 Bars
7"
#3 Bars @4"c/c
12"
5#4 Bars
12"
SECTION 01
7"
#3 Bars @8"c/c
12"
5#4 Bars
12"
SECTION 02
4#6 Bars
7"
#3 Bars @4"c/c
12"
5#6 Bars
12"
SECTION 01
2#6 Bars
7"
BEAM B2
#3 Bars @8"c/c
12"
5#6 Bars
12"
SECTION 02
3#3 Bars
7"
#3 Bars @4"c/c
12"
5#3 Bars
12"
SECTION 01
2#3 Bars
7"
BEAM B3
#3 Bars @8"c/c
12"
4#3 Bars
12"
SECTION 02
3#3 Bars
7"
#3 Bars @4"c/c
12"
5#3 Bars
12"
SECTION 01
2#3 Bars
7"
BEAM B4
#3 Bars @8"c/c
12"
4#3 Bars
12"
SECTION 02
1211 10 9 8 76 5 4 3 2 1
8' 2'-712"
7'-9" 3'-712" 10'-112" 12'-6" 10'-2"
1'-3" 3'-312"
WF1
A 2'-9"
WF1
WF1 WF1
WF1
B
WF1
11'-312"
CF1
5'
E 5' 10'-9"
CF1
Excavation Plan
9" Thick Brick Masonry Wall
2" F.F.L
Plinth Beam
G.L
Brick Masonry
9" 3'
9"
Concrete 1:4:8 412"
2'-9"
9"
Concrete (1:4:8)
5'
CF1
CE1 CE1 CE1 CE1 CE1 CE1
C1 C1 C1 C1 C1
CE1
C1
C1 CE1
Columns Plan
15"
4 #3 Bars +4 #4 Bars
15"
#3 Bars @5"c/c
Section A-A
COLUMN C1 DETAIL
9"
4#3 Bars
9" #3 Bars @9"c/c
Plinth Beam
Slab Bottom Reinforcement
56'-8 1/2"
11'-4 11'-4
1/2" 1/2" 12'-6" 11'-3 1/2"
10'-2"
3"
11'-616 10'-412" 11'-6" 9'-2" 10'-312"
24'-9"
23'-9"
23'-9"
23'-9"
23'-9"
23'-9"
57'-1012"
10'-012"
11'-012"
5"
63'-516
13'-9" 13'-9"
14'-012" 13'-512"
9'-712"
10'-912"
55'-0"
21'-1"
22'-1"
10'-912"
10'-7 1/2"