Control of Packed Goods - Net Version: Manual Number: KTI-07-01/05/06/A
Control of Packed Goods - Net Version: Manual Number: KTI-07-01/05/06/A
Control of Packed Goods - Net Version: Manual Number: KTI-07-01/05/06/A
KTI-07-01/05/06/A
Control of packed
goods - net version
Scales with
TMC Terminal
MANUFACTURER OF ELECTRONIC
WEIGHING INSTRUMENTS
RADWAG 26 – 600 Bracka 28 Street,
POLAND
Radom, tel.+48483848 800, tel/fax +4848 385 00 10,
Sales departament +4848 366 80 06
www.radwag.com
MAY 2006
-2-
Table of contents
-3-
1. GETTING STARTED
General information
− The intended use is to weigh goods with the possibility of tarring within
the full measuring range.
− You can start the procedure of control from the level of computer and
from the level of terminal.
PC software allows:
-4-
Remarks concerning the save usage of scales
3. Devices can fail while supplying from mains caring interference from
other devices.
2. KEYBOARD
-5-
2.1. Scale part
1 – zero indication
2 - equilibrium
3 – tare in memory
4 – second range
-6-
2.4. Functions of keys
Display on/off
Zeroing
Printout
Tarring
-7-
4. POWERING UP
Connect all weighing platforms and all other devices to the terminal and
push the start button.
Wait for complation of the test. The display will indicate zero.
-8-
After establishing communication following information appears on the
display:
- Operator
- Product to control
- Describing data
- Menu
- batch quantity
Enter the batch quantity and confirm it by pressing ENTER
- batch number
Enter the batch number and confirm it by pressing ENTER
-9-
Consider following remarks:
Key Function
Backspace
Inscribing codes
- 10 -
5. WEIGHING
Put a load on the scale pan. The result is ready to read after reaching
equilibrium (signalling diode marked by ).
After reading the result unload the pan. The indication returns to zero. For
two range scales switching between ranges appears automatically while
loading. The scale returns automatically to the first range accuracy after
returning to zero (autozero zone).
Weighing in the second range is signalled by a diode marked – >|2|<. If
after unloading the pan the indication is not zero press →0← key.
5.1. Tarring
For measuring the net mass of a load put a package/container on the pan
and press TARE (the display shows zero the signalling diode T is lit).
5.2. Zeroing
The zeroing range is within 4% of the maximal range around zero. If any
trial of zeroing is performed beyond the zeroing range –Err 2- appears on
the display.
- 11 -
6. GETTING STARTED
In order to adjust the scale for a specific conditions set filters to eliminate
vibrations, possible shocks.
MEDIAN FILTER
This filter is intended to suppress single mechanical shocks. The higher
value of the filter the longer period of stabilisation.
Procedure:
− Press Info key
− You will see the menu of parameters:
Device Parameters
Basic Parameters
Transmission Parameters
Printer
Additional Devices
Program Parameter
- 12 -
− Select the parameters’ group using arrows and press Enter. Press
Esc to leave a function or to reach the higher level of the menu.
Setting parameters:
− Set the cursor using arrows next to Filtr.
− Press Enter.
− You will have a blinking cursor over the parameter value. It means
that the value can be changed. Use arrow keys to change the
value.
− Chose one of the following settings:
1 – very fast
2 – fast
3 – average
4 – slow
− Press Enter to confirm changes.
− Press Esc to leave parameters.
- 13 -
6.1.1 Device parameters – median filter
− Press .
− You will have a blinking cursor over the parameter value. It means
that the value can be changed. Use arrow keys to change the
value.
- 14 -
Clock
- 15 -
NOTICE:
All values should be inscribed. All skipped values will have prescribed
00 value.
Terminal Address 1 – the same address like in KTP NET software. This
address should characterise the terminal.
List of parameters:
Computer - (NONE,COM1,COM2,COM3,COM4,COM5(485))
Computer baud rate - (terminal-computer baud rate)
Ethernet - (No/Yes)
MAC address - 255.255.255.25
IP address - 255.255.255.25
Subnet mask - 255.255.255.25
Default gate - 255.255.255.25
Local port -0
IP host address - 255.255.255.25
Host Port -0
Ethernet config - Server
- 16 -
7.3. Printer
Printer - (NONE,COM1,COM2,COM3,COM4,COM5(485))
Printer baud rate - (terminal-printer baud rate)
The above setting allows software to recognise products using only a part
of code.
- 17 -
7.5. Program Parameters
Notice:
If P40 Density in code is set to YES, the main display forth line changes as
below: F4 - Dns.
8. INSCRIBING CODES
Codes can be inscribed only in weighing mode (g or kg diode is lit).
Key Code
Assortment
Operator
Batch quantity
- 18 -
LCD view (e.g.):
Functions of keys:
keys Description
Backspace
Cursor left
Cursor right
Inscribing codes
- 19 -
9. PERFORMING CONTROL
Before starting control you must inscribe 4 codes. This way you can
identify:
− Product name
− Operator name
− Batch quantity
− Batch number or density
LED display should indicate zero, otherwise press →0←. Press F1 and
enter an assortment code. Then enter the rest of codes.
F1 – article name
F2 – operator name
F3 – batch quantity
F4 – batch number
- 20 -
9.2. Control with average tare
For this option the sequence of weighing is empty packages then the
products with the packages. The number of sequence of empty packages
(charge) can be set on the level of computer connected with a product.
- 21 -
9.4. Control with different tare values (full/empty)
For this option you can weight gross value of goods and then empty
packages.
This module can check the tare value and save it to the database on the
computer level. This can be possible only when the appropriate option is
set on the computer level.
Procedure:
− complete or terminate the control
− press Spec.
− communication window will be displayed
− Press Enter (start of procedure)
or Esc (leaving module)
- 22 -
− Put subsequent packages on the scale,
− After stabilising press Enter,
− If the average tare is acceptable (standard deviation criterion) you
will see an appropriate message
Before starting control operator must enter his/her own code and a
code describing a product. It can be done by:
− Inscribing,
− Finding in the database KTP NET.
- 23 -
or
- 24 -
9.6.2. Searching the assortment database
- 25 -
10. TECHNICAL PARAMETERS
- 26 -
TMC TMC TMC TMC TMC
Type 15/30 15/30 30/60 30/60 60/150
KTPS/H2 KTPS/H3 KTPS/H3 KTPS/H4 KTPS/H4
Manual Number:
KTI-07-01/05/06/A
- 27 -
MANUFACTURER
OF ELECTRONIC WEIGHING
INSTRUMENTS
ZMP ,,RADWAG”
26 – 600 Radom, Bracka 28 Street
POLAND
Tel. +48 48 38 48 800, tel./fax. + 48 48 385 00 10
Selling department + 48 48 366 80 06
www.radwag.com