0% found this document useful (0 votes)
832 views3 pages

Instruction Manual: Rishabh Instruments Pvt. LTD

This document provides instructions for installing and operating TNC switches manufactured by Rishabh Instruments Pvt. Ltd. Key points include: 1. The switches comply with international safety standards and should be permanently installed in an enclosure with the supplied hardware and wiring. 2. Proper installation location should be selected to protect from water and wires should not be under tension. 3. Testing is recommended before installation to check connections using a multimeter. Regular maintenance by qualified personnel is also advised.

Uploaded by

ShiaTVfan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
832 views3 pages

Instruction Manual: Rishabh Instruments Pvt. LTD

This document provides instructions for installing and operating TNC switches manufactured by Rishabh Instruments Pvt. Ltd. Key points include: 1. The switches comply with international safety standards and should be permanently installed in an enclosure with the supplied hardware and wiring. 2. Proper installation location should be selected to protect from water and wires should not be under tension. 3. Testing is recommended before installation to check connections using a multimeter. Regular maintenance by qualified personnel is also advised.

Uploaded by

ShiaTVfan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Instruction Manual

RISHABH TNC Switches


1. General : * Select mounting location which is * It is recommended to test the switch
This Switch complies with international protected from water on front and before installation as per connection
standard IEC 60947- 1, IEC 60947- 3 & back side of switch. diagram using multimeter.
IEC 60947- 5. * Ensure that wires do not remain
This product must be used after under tension. 7. Servicing of Cam Switches :
mounting in panel with hardware 5. Operation & Maintenance : * Cam switch need not required to be
supplied, with wires permanently serviced if proper fuse protection and
* Equipment must be installed &
connected to terminals as specified. dust protection are provided.
maintained by suitably qualified
2. Meaning of symbols : However if contact failure occurs due
person.
to accumulation of dust near contact
- European Conformity Mark * If equipment is used in a manner area, dust can be cleaned by blowing
-Switch/Disconnector Symbol not specified by manufacturer, the air.
3. Specification : protection provided by the
* If contact are slightly welded due to
equipment may be impaired.
Refer technical data chart. insufficient fuse protection, weld can
* Disconnect supply before be opened by forcibly operating the
4. Equipment Installation :
installation of Switch and during knob to a limited extent.
* Due consideration should be given to maintenance.
space behind the cam switch to allow for NOTICE
* Ensure that cables are properly This product has been designed for
bends in connecting cables.
tighten with self lifting screw. environment A. Use of this product
* The products do not have internal in environment B may cause
protection against overload & short 6. Testing : unwanted electromagnetic
circuit,hence external safety protection * Cables should be connected at disturbances in which case the
should be provided. It is recommended specified position as shown in user may be required to take
connection diagram. adequate mitigation measures.
to install protective device near a
equipment.

Panel Mounting
Assembly

Type M1 M2 M3
Rish Cam 25A 48 4 12
Rish Cam 32A 48 4 12

Panel Cutout
Details

Rishabh Instruments Pvt. Ltd. 1/3


F-31, MIDC, Satpur, Nashik-422 007 India
Phone (0253) 2202162
Fax : 91 - 0253 - 2351064, 2202302
E-mail : [email protected] , www.rishabh.co.in
Instruction Manual
RISHABH TNC Switches

Technical Data

Conformance to standards : Operating Conditions : Switch Life :


Frequency : 50/60 Hz Mechanical Life : 1 Lac operations @ 300 Cycles/hr
European : IEC 60947-1 o o
Operating Temp. : -25 C to 60 C Electrical Life : 10,000 opeartions @ 100% Rated duty at 120 cycles/hr
IEC 60947-3
Over voltage category : III
IEC 60947-5 o o Contacts : Double break type AgNi
Storage : -40 C to 80 C
Indian : IS 13947-1/3/5 Double break type AgCdO
Max. Altitude : 2000 m
IP: 50 Front

Parameter Unit 25A 32A


Rated operational voltage (Ue) V 690 690

Rated Insulation voltage (Ui) V 690 690

Rated operational current (Ie) A 25 32


rated uniterrupetd current (Ith) A 32 40
Rated Impulse withstand voltage (Uimp) KV 6 6
Rated short time withstand current (Icw) (1s- Current) A 300 384

Rated Fuse short circuit current KA 10 10


Fuse size (Type gG /gM) A 25 32

AC23A 3phase 220-240V KW 4.7 5.5


380-440V KW 7.5 11
500V KW 11 15

660-690V KW 11 15
AC23A 1phase 110V KW 1.5 2.2

220-240V KW 3 3.7

380-440V KW 5.5 7.5

AC3 3phase 220-240V KW 4.7 5.5

380-440V KW 7.5 11

500V KW
11 15
600-690V KW 11 15
AC3 1phase 110V KW 1.5 2.2
220-240V KW 3 3.7

380-440V KW 5.5 7.5


AC21A/AC1 A 25 32

AC15 220-240V A 8 14
380-440V A 5 6
Terminal cross -section

Single / Multiple Min mm2 2.5 2.5


Max mm2 4 6
Fine strand with sleeve Min mm2 1.5 1.5
Max mm2 4 4

Terminal screw Metric M4 M4

Terminal tightening torque Nm 1.2 1.2

* Rated short time withstand current (0.5s- current)

Rishabh Instruments Pvt. Ltd. 2/3


SR. DESCRIPTION NO. OF
NO. CONNECTION DIAGRAM/ TERMINAL MARKING STAGES

Trip Neutral Close (TNC) Switch


OUTPUT SIDE 1A 1B 1C 1D
0
NEUTRAL 60
T C
R L
I O
S
P E

1
1-2
INPUT SIDE LA LB LC LD
POLES 1 2
NEUTRAL
TRIP X X
CLOSE X X
Offered up to 2 poles