Xk3119wl-Ii User Manual
Xk3119wl-Ii User Manual
Weighing Indicator
Operation Instruction
Model:XK3119WL-II(LCD/LED)
Waterproof Weighing Indicator Usage Manual
Content
I. INSTRUCTION…………………........……….………….1
II. TECHNICAL FEATURES……………..…. ….……..….1
III. MAIN FUNCTIONS ……………………………..………1
IV. KEYBOARD FUNCTION……………………….........…2
V. BASIC INFORMATION SETTING……………......……3
VI. GENERAL PARAMETER SETTING………….....….....4
VII. CALIBRATION……………………………………......…6
VIII. CONFIGRATION SETTING………..……………….….7
IX. COUNTING FUNCTION ….….…….……….…..….….9
X. ERROR SIGNAL…………………………….………...10
XI. PRINTER FORMAT…………………………...………11
XII. INTERFACE CONNECTION………………….……..11
XIII. MAINTAINCE AND NOTES…………………..……..12
XIV. WARRANTY…………………………………....……..12
Waterproof Weighing Indicator Usage Manual
I. INSTRUCTION
XK3119WL-II (LCD/LED) indicator is an enhanced small indicator which consist of advanced
microprocessor making it a more reliable, stable, faster weighing speed and easy to operate. With
waterproof and insect prevention structure feature. The indicator is best used for industrial platform scales,
floor scales and various weighing machineries and equipment.
1
Waterproof Weighing Indicator Usage Manual
IV. KEYBOARD FUNCTION
Display symbol:
Stable indication Kg, lb, t, g Weigh units
TR
Tare mode Gross weight
Power ON/OFF switch key. Press and hold the key for 1.5 seconds, it will self-test till
weight zero appearance.
Deduct the container weight. Press this key to deduct the container weight and then display
net weight, tare indication light on.
* Weigh units switch while in weighing mode. Press to choose the desired weight units.
* ON/OFF backlight key while in weighing mode (for LCD indicator), press and hold for
1.5 seconds to turn on /off the backlight .
* Press to confirm the setting when it is in setting menu or calibration mode.
* Recall the memory of accumulative counts and weights, accumulative counts and weights
will display on the screen. Press to clear accumulative weight and time.
* Selective key when in setting menu.
* Press the key to print out the current weight (only allow one time to print out the current
weights), accumulative counts and weights will be shown. Note: this function work while
connecting printer. * Selective key when in setting menu.
4
Waterproof Weighing Indicator Usage Manual
When the “-HI- “ and “00000kg” indication is shining, please set the
highest weight. Once the loaded weight is over the setting highest
Press -HI- / -00000- weight, “HI” symbol indication (default red color) will display.
Press to select digit position and press to set the digit.
When the “-LO- “ and “00000kg” indication is shining, please set the
Press lowest weight. Once the load weight is under the setting lowest weight,
-LO- / -00000-
“-LO-” symbol indication (default purple color) will display.
Note: OC=010 means standard weight (default green color)
Effective term of check weighing mode:
X=0 means keep checking and alert, even if the reading is unstable.
Press X=1 means the indicator will alert after reading is stable.
SPt X
X=2~9 means the indicator will alert when the reading appear same
times as preset the number, it happens in reading is unstable.
Press to set the digit.
year/month/day
Press
05 18.05.29
Press to select digit position and press to set the digit.
Press
0.0 return back to weight mode, LED indicator setting finished.
5
Waterproof Weighing Indicator Usage Manual
USB output serial port, press enter into USB setting or press
Press - USB -
skip current step and enter into next setting.
10 Press 0.0 return back to weight mode, LCD indicator setting finished.
VII. CALIBRATION
* Plug the circuit breaker JP1 into “on”, and the following operation can be performed.
Please press and hold and keys together for 3 second until it displays “= = = = = =” then
release, the parameter in the table below will display on the screen:
1.Press to confirm the previous parameter and enter into next setp.
2.Press to operate previous parameter and to change setting.
6
Waterproof Weighing Indicator Usage Manual
Step Operation Screen Display Remark
01 CAL SP Enter into setting mode
0~9.eg:50kg.
Press to confirm.
A means zero range when power on, 1~9 means 10%~90% FS to zero.
05 Press Ut AB B= zero tracking range, 1~9 means 1~9x0.25d for tracking range.
Press to select digit position and press to set the digit.
7
Waterproof Weighing Indicator Usage Manual
Weight units switch.
Press - UnIt -
Press skip current setting and enter into next step.
Press Un 1 X First unit:0=kg; 1=Lb; 4=g.
06
When first unit=kg to switch, 1=LB; 2=t; 3=HI; 4=g; 5= PCS (counting).
Press Un 2 X When first unit=Lb to switch, 0=kg; 1=Lb; 5= PCS (counting).
When first unit=g to switch, 0=kg; 5= PCS(counting).
Output serial port 0;
Press rs - 0
Press skip current setting and enter into next step.
baud rate setting:2400/9600/14400/19200 selectable
Press bo 9600
Default data position: N, 8, 1
Press UOP1.X 0=56mm width thermal paper; 1=32mm width label paper.
Press UOP2.AB 00~99 selectable, default:10; A=paper advance; B=paper return back.
Press UOP3.X 0~9, Print font color; 0=the lightest color, 9=the darkest color.
X=0 means after stable, press key to print out and accumulative data.
Press UOP4.X
X=1 means after stable auto print out and accumulative data.
Press to confirm; Press select position or set digit ; Press to set digit.
08
Press CX C0~C9: Chinese print out format.
8
Waterproof Weighing Indicator Usage Manual
Press UOP1.X 0=56mm width thermal paper; 1=32mm width label paper.
Press UOP2.AB 00~99 selectable, default:10; A=paper advance; B=paper return back.
Press UOP3.X 0~9, Print font color; 0=the lightest color, 9=the darkest color.
X=0 means after stable, press key to print out and accumulative data.
Press UOP4.X
X=1 means after stable auto print out and accumulative data.
Press to confirm; Press select position or set digit ; Press to set digit.
Recommend to re-start the indicator after rs – 1 setting finished.
X=0 means after stable, press key to print out and accumulative data.
09 Press UoP4. X
X=1 means after stable auto print out and accumulative data.
Indicator ID code (selection range 0~99).
09 Press ID XX
Press and to change the value.
Weighing display stable parameter
A means response speed when weighing (0~5 selectable)
A=0 means the fastest response speed,
A=2: platform scale using response speed;
10 buf AB A=3: floor scale using response speed;
Press A=5 means the lowest response speed.
B means weighing stability, (0-3 selectable)
Stability increase by number.
Press to change value A, and press to change value B.
11 Press -HoLd- Lock the weight, press to skip the current setting.
Press save the setting above and return back to weight mode.
Press
12 - PASS - Press not save the setting above and return back to weight mode
9
Waterproof Weighing Indicator Usage Manual
When in weighing mode, press key, screen display “n 0” means enter into counting function.
2.How to operation?
Step 1: Load the sample items on the scale, after stable symbol “ ” display press three seconds
Step 2: Press & key to input the sample number, then press to confirm.
Step 3: Upload more test item which needed to be counted, the screen displays that total pieces of items and
When in weighing mode, press key, screen display “n 0” means enter into counting function.
Step 1: Load the sample items on the scale, after stable symbol “ ” display press three seconds
Step 2: Press & key to input the sample number, “ n 00100”, then press to confirm.
Step 3:Upload more test item which needed to be counted, said 400g, the screen displays will “00200
X.ERROR SIGNAL
There will shows error signal when the scale have some problem.
Error 1: means calibration isn’t workable, weight is too light or division is too high.
Error 3: means displayed value exceed display range after unit change.
10
Waterproof Weighing Indicator Usage Manual
XI. PRINTER FORMAT
There are two kinds of print out format with the external printer
2015-08-16 13:38
NO:001 2015-08-16 13:40
G.W: 10.00 ㎏ Add:003
N.W: 10.00 ㎏ Total: 30.00 ㎏
T.W: 0.00 ㎏
2. Connection of load cell signal wire (For 6 cores load cell only) :
While order with D-SUB-9 needle slot as figure 2 shows:
11
Waterproof Weighing Indicator Usage Manual
3 .CONNECTION OF RS-232 :(Please specify in the order if needed)
RS-232 serial interface is a D-SUB-9 needle slot as figure 2 shows:
2: Pin RXD
3: Pin TXD 1 9: Pin TXD 2
5: Pin GND
XIV. WARRANTY
We guarantee one-year of maintenance for free since the date of purchase for any non-man-made faults
in normal working conditions. For maintenance, please send the equipment with the guarantee card to our
sales service.
Attention: we are always improving the machine, there is not pre-notice if there are something
different comparing with the precious ones.
12