0% found this document useful (0 votes)
615 views

CC Series Metal Access Control Manual: 1.description

This document provides an overview and instructions for the CC Series metal access control system. It can control two doors and supports up to 2000 users with card and/or PIN access. The system has seven operating modes and provides features like anti-tamper alarms, multiple access methods, and management functions. Installation involves mounting the keypad and connecting wires based on a provided diagram. Programming allows configuration of settings like user access credentials, relay timing, and manager controls.
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
615 views

CC Series Metal Access Control Manual: 1.description

This document provides an overview and instructions for the CC Series metal access control system. It can control two doors and supports up to 2000 users with card and/or PIN access. The system has seven operating modes and provides features like anti-tamper alarms, multiple access methods, and management functions. Installation involves mounting the keypad and connecting wires based on a provided diagram. Programming allows configuration of settings like user access credentials, relay timing, and manager controls.
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 18

CC Series metal access control Manual

1.Description

CC Series is a standalone for two doors, support card, pin, card+pin access way. It is with 2 relays to control
2 doors and supports up to 2000 users in total,each user can possess one card and one pin.
It can directly drive Lock,Alarm,Ring Bell,and also can connect with Exit Button and Door Contact.

There are 7 working mode with this device.1.Wiegand Reader, 2.Standalone for single door, 3.standalone
for two doors,4.with external reader for two doors 5.two units interlocked for two doors,6.Anti-passback for
single door,7.Anti-passback for two door.

Besides, it also supports 1 Master code,2 Manager card, 2 Anti-duress Card users and 2 Anti-duress PIN
users, providing users with easy operations and safety reliability.

2.Features

1.Pure Zinc alloy case;waterproof conform to IP 68


2.Built-in 125KHz OR 13.56MHz card reader (CC1)
Built-in 125KHz and 13.56MHz card reader (CC2)
3.Perfect digital backlit key,the back light can be set to Normal ON,Normal OFF or Human-Approach ON
4.With anti-tamper Alarm,door contact Alarm,Anti-duress Alarm function
5.Add and delete card user quickly With Manager cards
6.Can register and delete user via keypad
7.Master can open the door when entering the setting status
8. Multi working modes: reader,one door,two door, interlock,anti-passback and so on, suitable for many occasions

3.Specification

Input Voltage AC/DC 12V


Idle Current<25mA
Lock output load<1A
Alarm output load<1A
Ring bell load<1A
Card reading distance 40mm Max
Card Frequency: 125KHz for EM and HID
13.56MHz for Mifare
Card transmission format 26-37 bit wiegand
Keypad transmission format:4bit,8bit and Virtual card number
Operating Temperature:-45°C~55° C
Operating Humidity:0%~95%

4.Installation

z Remove the back cover from the keypad using the supplied special screw driver
z Drill 2 holes on the wall for the Self tapping screws and I hole for the cable
z Put the supplied rubber bungs to into the two holes
z Fix the back cover firmly on the wall with 2 Self tapping screws
z Thread the cable through the cable hole
Attach the keypad to the back cover.

5.Wiring

ZONE1 ZONE2

No. Marks Color Description Marks Color Description

1 BELL_A pink Doorbell button D0 green Wiegand output D0

2 BELL_B pink Doorbell button D1 white Wiegand output D1

3 ALARM+ red Alarm anode AC1 red AC1 (+12V)

4 AC2 black AC input GND black GND

5 OPEN2 yellow Exit button OPEN1(LED) yellow Exit button (for green LED)

6 D_IN2 brown Door contact D_IN1(BZ) brown Door contact(for buzzer)

7 ALARM2- gray Alarm 2 ALARM1- gray Alarm 1

8 NO2 Blue Relay 2 NO end NO1 Blue Relay 1 NO end

9 COM2 purple Relay2Com COM1 Purple Relay1 Com

10 NC2 orange Relay2 NC end NC1 Orange Relay1 NC end


6.Sound and Light Indication

Operation LED Color Buzzer


Standby Red flash
Press key Di
Read card Green Di-
Door 1 Open Green Di-
Door 2 Open Green Flash Di-
Operation Successful Green Di-
Operation Failed DiDiDi
PIN Inputting Red
Card&PIN Reading Red
Multi Card Reading Red
Under Menu Red
Under Setting Orange
Manager Card Enter Orange DiDi
Manager Card Exit Red Flash Di-
Alarm Red Quick Flash Alarm

7 Quick Programming Guide


7.1 Administrator Setting

Stand Maste
Menu Setting Remarks Functions
by r Code
Red Red Red Orange
Flash
* Maste 00 New master code# Repeat new master code # Factory Change the master code
r (Note:Code length:6-8 digits) default:999999
code# 01 Read Manager Add Card Default:Zone 1 Set Manager Add Card
02 Read Manager Delete Card Set Manager Delete Card
03 Read Anti-duress card (Zone 1) Set Zone1 Anti-duress card
04 Read Anti-duress card (Zone 2) Set Zone2 Anti-duress Card
05 Anti-duress PIN# (Zone 1) Set Zone1 Anti-duress PIN
06 Anti-duress PIN# (Zone 2) Set Zone2 Anti-duress PIN
07 0000# Delete All Users
51 Master open Lock 1
52 Master open Lock 2

7.2 User setting for Zone 1


Standb Master
Menu Setting Remarks Functions
y Code
Red Red Red Orange
Flash
* Master 11 Read card Users can be added To add card users
code User ID number# read card continuously without exiting
# Card number# programming mode
ID number#card number#
User ID number#PIN# To add PIN users
12 Read card Users can be deleted To delete users
User ID number# continuously without exiting
Card number# programming mode
13 0# Default 2 Entry by Card
1# Entry by card+PIN
2# Entry by either Card or PIN
14 0-99# Default 5 Set door relay time
15 0# Default 0 Relay Setting-Pulse mode
1# Relay Setting-Toggle mode
16 1-10# Default 1 To set open door by multi cards
17 User ID number#,card To add a series cards users
number#,card quantity#

User setting for Zone 2


Standb Master
Menu Setting Remarks Functions
y Code
Red Red red orange
Flash
* Master 21 Read card Users can be added To add card users
code User ID number# read card continuously without exiting
# Card number# programming mode
ID number#card number#
User ID number# PIN# To add PIN users
22 Read card Users can be deleted To delete users
User ID number# continuously without exiting
programming mode
Card number#
23 0# Default 2 Entry by Card
1# Entry by card+PIN
2# Entry by either Card or PIN
24 0-99# Default 5 Set door relay time
25 0# Default 0 Relay Setting-Pulse mode
1# Relay Setting-Toggle mode
26 1-10# Default 1 To set open door by multi cards
27 User ID number#,card To add a series cards users
number#,card quantity#

7.3 System Setting

Master
Standby Menu Setting Remarks Functions
Code
Red Red red orange
Flash
* Master 30 0-15# Default 0 To set facility code
code 31 0# When device reset Wiegand reader
# 1# to factory Standalone for single door ( Factory
default ,the setting default setting)
2# is still valid Standalone for two doors
3# With external reader for two doors
4# Two units interlocked for two doors
5# Anti-passback for single door
6# Anti-passback for two door
32 26-37# Default 26 To set Wiegand format
33 0-2# When device reset To set keypad transmission format
to factory
default ,the setting
is still valid
34 1-3# Default 1 To set alarm time
35 0# Default 0 Safe mode 0
1# Safe mode 1
2# Safe mode 2

7.4 User optional setting


Maste
Standby r Menu Setting Remarks Functions
Code
Red Flash Red red orange
* Maste 41 0# Buzzer will be be in silence except enter the
r code programming mode
# 1# Default 1 Buzzer will sound when press the key
42 0# Disable keypad backlight
1# Enable keypad backlight
2# Default 2 Automatic mode,Normally it is off(sleeping mode)
but wake up with human approach
43 0# LED Light Disable when stand-by status
1# Default 1 LED flash when stand-by status

Instruction:
1.Master code must be 6-8 digits, Anti-duress PIN must be 8 digits,user PIN is 4-6 digits,The 1st digit of user PIN and Anti-duress
PIN in Zone1 must be 1; The 1st digit of user PIN and Anti-duress PIN in Zone 2 must be 2.
2.the user ID number is any number among 1-2000,Invalid 0 can be omitted; card number must be 8 or 10 digits,if the card number is
less than 8 or 10 digits, input 0 before the card number.
3.Door open time is 0-99 second,0=50mS
4.when register one card user into the device, the device will automatically generate a PIN 1234 , this PIN cant open the door door.
5.when an invalid master pin is pressed the device will go back to the standby status after 5 seconds, when a valid PIN is entered it
will go back to standby status after 30 seconds.
6.in operating the keypad, pressing # means to confirm the input digits ,In operation of a cycle adding or deleting cards, pressing #
means to end the cycle operation and back the up operation; pressing * means to exit the operation.
7. When add a series cards, this unit will make the ID number and card number initial value; after adding one user, then it will
increase the ID number and card number automatically ,Until the specified number of card is added.the card number must be
consecutive card quantity is between 1-2000.
8. Working mode and keypad transmission format have been set before shipping, customer can change according to requirement, but
when device reset to factory default, the setting is still valid.
9.when users of Zone 1 is registered successfully, LED will turn green; when users of Zone 2 is registered successfully, LED will be
green flash.

8. Administrator setting
Administrator setting on keypad
Press * Master code # factory default:999999,
8.1 Change the master code
Press 00 new code # repeat new master code#
Note: Master Code length:6~8 digits

8.2 Set Manager card


Set manager add card
Press 01 read manager add card
Set manager delete card
Press 02 read manager delete card
Note: when add the new manager card, the new one will automatically cover the old card, only one manager card for one device
8.3 Set Anti-duress card
Set Anti-duress card for Zone 1
Press 03 read anti-duress card (Zone 1)
Set Anti-duress card for Zone 2
Press 04 read anti-duress card (Zone 2)
Note: when add the new anti-duress card, the new one will automatically cover the old card, only one anti-duress card for one device

8.4 Set Anti-duress PIN


Set Anti-duress PIN for Zone 1
Press 05 8-digit duress PIN#(Zone 1)
Set Anti-duress card for Zone 2
Press 06 8-digit duress PIN#(Zone 2)
Note: 1.the 1st digit must be 1 for Zone 1
2.the 1st digit must be 2 for Zone 2
3. when set the new anti-duress PIN, the new one will automatically cover the old anti-duress PIN, only one anti-duress PIN for one
device

8.5 Delete all users


Press 07 0000 #
Note: both zone 1 and zone 2 will be deleted. This is a dangerous option, so use with care.

8.6 Set administer open lock


Set administer open Lock 1
Press 51
Set administer open Lock 2
Press 52

8.7 Users setting for Zone 1


8.7.1 read card to add user
Press 11 read card # read card ... #
8.7.2 use ID Number and read card to add user
Press 11 ID number # read card ... ID number # read card ... #
8.7.3 use card number
Press 11 card number # ... card number# ... #
Note: 1.Card number must be 8 or 10 digits, if the card number is less than 8 or 10 digits, input 0 before the card number

2.Automatically increases, the user ID will be generated by the machine automatically, the range is 1 ~ 2000, and
automatically search from 1 to 2000

8.7.4 Use ID number and card number to add user


Press 11 ID number # 8-digits card number # ... ID number# 8-digits card number# ... #
Note:1.ID number is 1~4 digits, the range is 1~2000, 1,01,001,0001, all these mean ID number 1.
2.add card user will generate one “1234 “PIN, this PIN cant open door, only for user modify PIN

8.7.5 use ID number and PIN to add user


Press 11 ID number#PIN # ... ID number#PIN# ... #
Note: this fit PIN user, pin is irrelevant with card, the PIN is any 4-6 digits,1st digits must be 1 for Zone 1 with the exception of
1234 which is reserved.

8.8 Delete user


8.8.1 read card to delete user
Press 12 read card read card ... #
8.8.2 use ID number to delete user
Press 12 ID number # ID number # ... #
8.8.3 use card number to delete user
Press 12 card number # card number # ... #
8.8.4 delete all users
Press 07 0000 #
Note: both zone 1 and zone 2 will be deleted.

8.9 Set opening door mode:


8.9.1 Entry is by card only
Press 13 0 #
8.9.2 Entry is by card and PIN together
Press 13 1 #
8.9.3 Entry is by card or PIN (factory default)
Press 13 2 #

8.10 set door relay time


Press 14 0~99 #
Note: 0~99 is to set the door delay time 0-99 seconds, factory default is 5 seconds
8.11 Set Relay mode
Relay setting -pulse mode
Press 15 0 #
Every time a valid card/tag read or PIN input, the relay will operate,
for the pre-set relay pulse time. (Factory default setting)
Relay setting-Toggle mode
Press 15 1 #
Every time a valid card/tag read or PIN input, the relay changes state, which will not turn back until read card/tag or input PIN again

8.12 Set opening door by multi cards


Press 16 card quantity #
Note: the door will be opened only after reading all the valid multi cards up to the card quantity setting. It is only for card entry
mode(Factory default setting :1)
8.13 Add a series consecutive cards users
Press 17 ID number # card number # card quantity #
Note: the card number must be consecutive card quantity is between 1~20000; card number is 10 digits or 8 digits

8.14 User setting for Zone 2


The method is the same with Zone 1, corresponding menu should be 21,22,23,24,25,26,27
8.15 system setting
8.15.1 To set facility code
Press 30 0~15 #
Note: code should be 0~15, factory default setting :0

8.15.2 Wiegang Reader


Press 31 0 #

8.15.3 standalone for single door(Factory default setting)


Press 31 1 #

8.15.4 Standalone for two doors


Press 31 2 #

8.15.5 With external reader for two doors


Press 31 3 #

8.15.6 Two units interlocked for two doors


Press 31 4 #

8.15.7 Anti-passback for Single door


Press 31 5 #

8.15.8 Anti-passback for two doors


Press 31 6 #

8.16 To set wiegang format


Press 32 26 34 37 #
Note: factory default setting :26
8.17 setting keypad transmission format
Press 33 0~2 #
Note: keypad transmission format is 0 1 2, factory default is 0; when device reset to factory default, the setting is still valid.
8.18 Setting alarm time
Press 34 1~3 #
Note: 1. factory default is 1 minute
2. when device reset to factory default, the setting is still valid.

8.19 setting safe mode


8.19.1 normal mode (factory default)
Press 35 0 #
8.19.2 dead mode
Press 35 1 #
If read invalid card or input wrong PIN 10 times in 10 minutes, system will be dead for 10 mins
8.19.3 alarm mode
Press 35 2 #
if read invalid card or input wrong PIN 10 times in 10 minutes, external alarm and built-in buzzer will work.

8.20 user optional setting


8.20.1 setting keypad tone OFF or ON
Press 41 0 #
The device will be in silence except enter the programming mode
Press 41 1 #
The device will give the voice when press the keys (Factory default setting)
8. 20.2 setting keypad backlight
Disable keypad backlight
Press 42 0 #
Enable keypad backlight
Press 42 1 #
Automatic mode (factory default setting)
Press 42 2 #
Normally it is off(sleeping mode) but wake up with human approach
8.20.3 setting LED light (stand-by status)
Disable LED light
Press 43 0 #
Flash LED light (factory default setting)
Press 43 1 #

Manager card operation


8.21 add user for Zone1
Read Manager Add Card, read user cards continuously, read Manager Add card again.
8.22 delete user for Zone 1
Read Manager Delete Card, read user cards continuously, read Manager Delete card again.

9 User Operation
9.1 Entry by card mode,Set multi cards to open door when card quantity is 1
Read user card, lock will be unlocked
9.2 Entry by card mode,Set multi cards to open door when card quantity is 2-10
Read these cards one by one, present each card in 5 seconds, lock will be unlocked
9.3 Entry by card and PIN
Present card, then press PIN(4 to 6 digits ), #, lock will be unlocked
9.4 Entry by card or PIN mode
Present card, lock will be unlocked
Or Press PIN(4 to 6 digits ), #, lock will be unlocked
9.5 Relay mode
Relay setting -pulse mode
every time a valid card/tag read or PIN input, the relay will operate, for the pre-set relay pulse time.
Relay setting-Toggle mode
Every time a valid card/tag read or PIN input, the relay changes state, which will not turn back until read card/tag or input PIN again

9.6 Modifyuser PIN (no need enter programming mode)


*, read user card, press old PIN, #, new PIN # new PIN #
Or *, press ID number # old PIN# new PIN # new PIN #
Notice: user who dont have user card must get ID number and origin PIN from Admin, Zone 1 users PIN must start with 1, Zone 2
users PIN must start with 2.

10 Alarm function
10.1 Anti-tamper alarm
if the device is disassembled illegally, the buzzer and the external alarm will operate.

10.2 Door contact alarm


When connect with door contact, if the door is opened illegally, the buzzer and the external alarm will operate.

10.3 The Anti-duress alarm


When read zone 1 anti-duress card/input 8-digit anti duress PIN or zone 2 anti-duress card/input 8-digit anti duress PIN, then press #,
The corresponding lock will open, at the same time, the external alarm witll operate,but the device buzzer will not operate.

10.4 remove alarm


read valid user card, manager card or input master code, then alarm will be removed. If no any operation, alarm will be removed
automatically after 1 min.

11 Multi working mode:


There are 7 working mode with this device.
1.Wiegand Reader
2.Standalone for single door
3.standalone for two doors
4.with external reader for two doors
5.two units interlocked for two doors
6.Anti-passback for single door
7.Anti-passback for two door
The factory default is Standalone for single door (we can change the default model according to customer order). User can modify
the working mode, when the device reset to factory default,the setting is still valid.

11.1 Wiegand Reader mode

In this mode, the access control works as reader,connected with the common access controller, it has following function.
Modify master pin
Set facility code
Set the card transmission format
Set the keypad transmission format
Set optional setting
Anti-Tamper alarm

When LED level is low,indicator light(LED) will turn into green, after 30 seconds or LED level rising, LED will back to normal.
When BZ level is low,the buzzer will beep,after 30 seconds or BZ level rising, the buzzer will back to normal.
When it used as the reader, both card number and keypad transmits in Wiegang format,the output data are shown by the low level of
DO&D1 wire:
D0:low level means 0,green wire
D1:Low level means 1,white wire

The Pulse width of low level is 100uS,bit period is 1.6mS


The digits of card number can be set to 26-37 bit, should be matched with the controller.(Factory default is 26Bit)
Keypad transmission can be set in the following 3 modes(modes can be set by user)

Model 0: Virtual card number


The reader will transmit the PIN data when it receives the last key(#) press after PIN code
Format: Decimal card number with 10 digits, Facility code(1st~4th digit)+PIN Code(5th-10th digit)
Facility code is any digits between 0~15,PIN code is 4~6 digits
Example:facility code :15
PIN code:9999
Press 9999 #, then output format will be: 0015009999
PIN code: 999999
Press 999999#,then output format will be 0015999999

Model 1: 4 Bit
The output data is provided in following format after every key is pressed:

key Output in hex Output in Binary


0 0 0000
1 1 0001
2 2 0010
3 3 0011
4 4 0100
5 5 0101
6 6 0110
7 7 0111
8 8 1000
9 9 1001
* A 1010
# B 1011

Model 2: 8 Bit
The output data is transmitted in following format after every key is pressed:

key Output in hex Output in Binary


0 0 11110000
1 1 11100001
2 2 11010010
3 3 11000011
4 4 10110100
5 5 10100101
6 6 10010110
7 7 10000111
8 8 01111000
9 9 01101001
* A 01011010
# B 01001011

11.2 Standalone for single door


In this mode, the device supports connecting external card reader for exiting door.
The users of Zone 1 or external can open the door by valid card or PIN.

11.3 Standalone for two doors


In this mode, users are for controlling two doors. Read valid card or input PIN of Zone 1 on this unit, door 1 will be opened; reading
valid card or input PIN of Zone 2 on this unit, door 2 will be opened.
Remark: the common card for Zone 1 and Zone 2 can only open door 1.

11.4 With external reader for two doors


In this mode, this unit is for entering door 1,and external reader is for entering door 2.
Read valid card or input of Zone 1 on the machine, door 1 will open; read valid card or input PIN of Zone 2 on external reader, door
2 will open.
Remark: the common card for Zone 1 and Zone 2 can open door 1 on this unit, and open door 2 on external reader.

11.5 Two units interlocked for two doors


The interlock function is mainly used in banks ,prisons,and other places where a higher level security is required.
When and only door 2 closed, read valid card / input PIN on this machine, door 1 will open; when and only door 1 closed, read valid
card/input PIN on external reader, door 2 will open.
Remark: The valid card /PIN is only for users of Zone 1,users of zone 2 are invalid.

11.6 Anti-passback for Single door


In this mode, this unit install outside is for entering door, external reader inside for exiting door, the users can only enter door when
read valid card on the machine, and exit from the inside external reader. If without the entering record from the machine, the users
can not exit from the inside reader, also the Users can’t enter in twice without the first exit record.
Remark: this is only for card users of Zone 1,PIN users of Zone 1 an all users of Zone 1 are invalid.

11.7 Anti-passback for two doors


In this mode, this unit on door 1 is anti-passback master unit, and external reader on door 2 aa the anti-passback auxiliary unit.then
they build up a two doors anti-passback system,which is normally used for parking lot.
The users can only enter door 1 when read valid card on this unit, and exit from door 2 when read valid card on external reader. If
without the entering record from door 1, the users can not exit from the door 2, also the users can’t enter in twice without the first exit
record.
Remark, this is only for card users of Zone 1,PIN users of Zone 1 and all users of Zone 2 are invalid.

12 diagram for 7 working mode


13 Instance Operations
13.1 Modify master code as 201200
press * 999999 # 00 201100 # 201100 # .
13.2 Set Anti-duress PIN of Zone 1 as 12012000
press * 201100 # 05 12012000 # .
13.3 add last 8 digit card number as 00967865 and 86998736 user of Zone 1
Press * 201100 # 11 00967865 # 86998736 # .
13.4 add first 10 digit card number as 0098786500 and 8699873600 user of Zone2
Press * 201100 # 21 0098786500 # 8699873600 # .
13.5 add ID user 006, PIN 201200, Zone 2 user
press * 201100 # 21 6 # 201200 # .
13.6 set open mode of Zone 1 as card+PIN
press * 201100 # 13 1 # .
13.7 rapid increase consecutive numbers 1000 cards(start with 00987865 ID is 005)
press * 201100 # 17 05 # 00987865 # 1000 # .
13.8 set working mode as reader mode
press * 201100 # 31 0 # .
13.9 set card output format as WG34
press * 201100 # 32 34 # .
13.10 set master open lock 1
press * 201100 # 51 .

14 Simple Troubleshooting

Code Fault Fault Cause Solutions


1 Close Read range Quality of card Use original card
1.first number of PIN should be 1 or 2,match with Area number
Problem in PIN 1.PIN is not standard 2.PIN shouldn’t be 1234
2
setting 2.Set Password at reader mode 3. PIN is 4 to 6 digits
4.don’t set PIN at reader mode
1.1234 is original PIN, can’t open the door, should be modified as
PIN can’t open 1 use PIN 1234
3 other PIN
door 2 entry mode setting
2.set open mode as entry by card or PIN.
Alarms at normal While installation, light leak While installation, device should closed to the wall
4
condition under bottom
5
No responds Press * key, light flash, units back to ready mode
6 Units are not in ready mode
after card reading
1.set keypad light as shine or auto
Keypad light is Mode of keypad light setting is
7 2.under auto mode , light shine after press keypad , delay 30
not bright wrong
seconds
Can’t enter Reset to Factory Default , master code will be 999999 , only
8 Forget master code
master mode installer data is restored, user data will not be affected

15 To Reset to Factory Default

a. Disconnect power from the unit


b. Press and hold # key whilst powering the unit back up
c. On hearing two “Di” release # key, system is now back factory settings
Please note only installer data is restored, user data will not be affected

16 Packing List
Name Model/size Quantity Remarks
Keypad CC1/CC2 1
User manual CC1/CC2 1
Self tapping screws Φ4mm×27 mm 2 Used in fixing
Rubber plug Φ6mm×30 mm 2 Used in fixing
Star screw driver Φ20mm×60mm 1 Special for Keypad
two-electrode valve 1N4007 1

Warm Tips

* Please do not to repair the device privately, if have problem, please return to the supplier.
*Before installation on wall, please check carefully concealed wiring or wire tube, in case of he trouble from broken concealed
wiring etc when drilling, please use safe glasses when drilling or fixed line clip.