Comen Bilanx AX-600 Anesthesia Machine - EN - V1.0

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

Bilanx AX-600

Anesthesia Machines
Technical specifications
Physical specifications
Dimensions and Weight
Height: 1400mm
Width: 810mm
Depth: 680mm
Weight: About 125Kg(without vaporizer and cylinder)

Top shelf
Weight limit:20Kg
Width: 508mm
Depth: 313mm

Work surface
Weight limit:20Kg
Size: 472×248mm

LED Light
Illuminates all work surface

DIN rail
Side of machine: Upper:290mm
Lower:479mm

Drawers (two))-Locking(internal dimensions)


Upper: 462×287×141 mm
Lower: 437×287×245 mm

Handle Length:750mm

Casters
Diameter: 125mm
Brakes: Individual locking

Screen
Display type:Color TFT LCD(touchable)
Display size:12.1”
Resolution: 800×600
Brightness: Adjustable
Display Parameters: All settings and alarm parameters(Peak pressure,Pplat,Pmean,
PEEP,Tidal volume,Minute volume,Breath rate,I:E ratio,
FiO2,FiCO2,EtCO2)
Display Graphics: Standard:waves of Pressure-Time,Flow-Time,Volume-Time;
Optional:Loops of Pressure-Volume,Flow-Volume and Pressure-
Flow,Wave of CO2

Timer: The time of operation will be displayed on the screen


Loops: F-V,P-V and P-F loops

Ventilator Specifications
Standby Mode:Machine is on call;System settings,ventilation and alarm parameters can be set

Modes of Ventilation-Standard
Volume-Controlled Ventilation(VCV)with tidal volume compensation
Mannual

Modes of Ventilation-Optional
Pressure Control Ventilation(PCV)
Synchronized Intermittent Mandatory Ventilation (SIMV)(volume and pressure)(SIMV-VC,SIMV-PC)
PSV (Pressure Support with Apnea backup)

Ventilator parameter ranges


Tidal volume range:20 to 1500 mL(VCV and SIMV-VC)
Incremental settings:20 to 100 mL(increments of 5 mL)
100 to 300 mL(increments of 10 mL)
300 to 1500 mL(increments of 25 mL)
Pressure (Pinspired) range: 5 to 70 cm H2O
increments of 1 cm H2O
Pressure (Plimit) range: 10 to 100 cm H2O
increments of 1 cm H2O
Pressure (Psupport) range: Off, 3 to 60 cm H2O
increments of 1 cm H2O
Rate range: 4 to 100 breaths per minute(increments of 1 breath per minute)
Inspiratory/expiratory ratio: 4:1 to 1:10
increments of 0.5
Inspiratory time: 0.2 to 5.0 seconds
increments of 0.1 seconds(SIMV and PSV)
Trigger window: 5% to 90% (increments of 5%)
Flow trigger: 1 to 15 L/min(increments of 0.5 L/min)
Pressure trigger: ﹣20 ~﹣1cmH2O(increments of -1cmH2O)
Inspiratory Pause time:OFF,5 to 60% of inspiratory time
increments of 1%
Positive End Expiratory Pressure (PEEP)
Type: Integrated, electronically controlled
Range: OFF, 3 to 30 cm H2O(increments of 1 cm H2O)
Ventilator performance
Pressure range at inlet: 0.28Mpa-0.6Mpa
Peak gas flow: 100 L/min + fresh gas flow
Flow valve range: 1 to 100 L/min
Flow compensation range: 200 mL/min to 15 L/min

Ventilator Accuracy

Delivery/monitoring accuracy
Volume delivery: <75ml,±15ml
≧75ml,±20ml or 10%,whichever is larger
Psupport/inspired: ±3.0cmH2O,or 8%,whichever is larger
Plimit: ±4.0cmH2O,or 10%,whichever is larger
PEEP delivery: ±2.0cmH2O,or 10%,whichever is larger
Volume monitoring:<75ml,±15ml
≧75ml,﹤1500ml,±20ml or 10%,whichever is larger
﹥1500ml,unspecified
Pressure monitoring:±3.0cmH2O,or 8%,whichever is larger

Alarm settings
Tidal volume (VTE):High: 5 to 1600 mL
Low: 0 to 1595 mL
Minute volume (VE):High: 2 to 100 L/min
Low: 0 to 98 L/min
Inspired oxygen (FiO2): High: 20 to 100%
Low: 18 to 98%

Low airway pressure: 0 - 98 cm H2O


High pressure: 2 - 100 cm H2O
Apnea alarm: 30s
Sustained airway pressure: Manual ventilation: sustained limit is 30cmH2O
Subatmospheric pressure: Paw < -10 cm H2O
Alarm silence countdown timer120 to 0 seconds

Ventilator Monitoring
Minute volume range(expiratory):0~100L/min
Tidal volume range(expiratory):0~2500ml
Inspired oxygen(FiO2):18~100%
Peak pressure:-20~120cmH2O
Mean Pressure:-20~120cmH2O
Plateau Pressure:0~120cmH2O
Positive End Expiratory Pressure(PEEP):0~70cmH2O
I:E: 4:1-1:12
Rate: 0~120bpm
Compliance: 0~250ml/cmH2O
Resistence : 0~500cmH2O/(L/s)
Trend Chart: continuous trend information together with time discrete events are stored and
shown by lines for the latest 60h with 5 seconds resolution for
Tve,Tvi,Ppeak,MV,Pplat,PEEP,Pmean,Rate and Optioal FiO2,EtCO2

Trend Table: continuous trend information together with time discrete events are stored and
shown by table for the latest 60h for Tve,Tvi,Ppeak,MV,Pplat,PEEP,Rate and
Optioal FiO2,EtCO2.
Resolution:5s,30s,1min,4min,optional .
New trend table will be recorded when restart the machine.

Vaporizer
Type: Draeger VP2000(Halothane, Isoflurane, Enflurane,Sevoflurane,Desflurane)
Positon of vaporizer: one or dual-positions
Installation mode: selectatec with interlock

Battery Backup
Battery backup : 120min
Battery type: Build-in Li-ion battery

Pneumatic Specifications
(ACGO)
Auxiliary common gas outlet( ) (optional)
Connector: ISO 22 mm OD and 15 mm ID

Gas supply
Pipeline input range: 0.28~0.6Mpa
Pipeline connections: NIST
Cylinder input: PISS,Maxium 2 cylinders,optional
Primary regulator nominal output: 200Kpa

Mechanical flow meters


O2 range: 0~10L/min
N2Orange: 0~10L/min
Air range: 0~10L/min
Accuracy: ﹤±10% of indication

Auxiliary O2 Flowmeter(Optional)
Range: 0~15L/min
Indicator: Flow tube

Hypoxic Guard System


Type: Mechanical
Range: Provides a nominal minimun 25% concentration of oxygen in O2/N2O mixture

O2 controls
Method: N2O shut off with loss of O2 pressure
Supply failure alarm:Range: 193 kPa to 221 kPa
O2 flush: 25~75 L/min

Breathing Circuit Specifications


Operational modes : Closed and semi-closed circuit system
System Pressure Gauge
Range: ﹣20~120cmH2O
Accuracy: ±(4% full scale+4% real indication)
Bag/mechanical Ventilation Switch:
Type : Bi-stable
Control: the switch between manual ventilation and ventilator
Integrated Adjustable Pressure Limiting (APL) valve
Range: 1 to 75 cm H2O
Tactile knob indication at: 30 cm H2O and above
Accuracy: ±10cmH2O

Breathing circuit parameters


Compliance:Bag mode:1.94 mL/cm H2O
Mechanical mode: Automatically for compression losses within the absorber
and bellows assembly
Expiration & Inspiration resistance:﹤6cmH2O@60L/min
Materials: All materials in contact with exhaled patient gases are autoclavable, except
flow sensors, O2 cell
All materials in contact with patient gas are free of natural rubber latex.
Volume of CO2 canister:about 1500ml
Water Trap:7ml,easy to drain
Port and Connectors:
Expiration/Inspiration connector: 22mm OD and 15mm ID conical
connector
Manual bag port: 22mm OD and 15mm ID conical connector

Gas Monitoring
Carbon dioxide (CO2)Modules( (optional) )
Method: Infrared absorption
Module type: Phasein ISA CO2 module
Work mode : Standby or Measurement
Displayed numerics: EtCO2,FiCO2
Wave forms: Capnography
Wave type: The CO2 wave is displayed as a filled area
Adjustable low and high alarm limits for EtCO2 and FiCO2

Anesthetic Agent (AA)( (optional)



Module type: Phasein ISA AG module
Work mode : Standby or Measurement
Displayed numerics: FiCO2,EtCO2,FiAA,EtAA,AA(Des,Sev,Iso,Enf,Hal),MAC
Halothane, Isoflurane, Enflurane
Measurement range: 0-8 vol%
Accuracy: ±(0.15 vol% + real indication5 %)
Sevoflurane
Measurement range: 0-10 vol%
Accuracy: ±(0.15 vol% + real indication5 %)

Desflurane
Measurement range: 0-22 vol%
Accuracy: ±(0.15 vol% + real indication5 %)

MAC value displayed


Adjustable high and low alarm limits for EtAA, FiAA

Anesthetic gas scavenging( (optional))


AGSS Type:High Flow , low vacuum
Applies with ISO 8835-3:1997
Connectors apply with BS 6834:1987
Flow of suction:50-80L/min
Pressure release :compensation port to atmosphere
Filter:stainless steel reseau with 140-150µm of diameter
Safety:Float sinks down while flow of suction is lower than 50L/min

Environmental Specifications
System operation
Temperature:10° to 40°C/
Humidity:15 to 95% relative humidity (non-condensing)
Barometric(Kpa):70~106Kpa

System storage
Temperature:-20° to 60°C/
Humidity:10 to 95% relative humidity (non-condensing)
Barometric(Kpa):50~106Kpa

Power Supply
With Isolation transformer Without Isolation transformer
External AC power supply
Input voltage 100~120V 220~240V 100~240V 100~120V
Input current 7.0A 3.5A 7.0~3.5A 7.0A
Input frequency 50/60HZ 50/60HZ
Leakage current <500µA <500µA
Auxiliary output supply (3 Outlets)
Output voltage 100~120V 220~240V 100~240V 100~120V
Output current 1.8A 0.9A 1.8~0.9A 1.8A
Output frequency 50/60HZ 50/60HZ 50/60HZ 50/60HZ