3000W True Sine Wave DC-AC Inverter: Series
3000W True Sine Wave DC-AC Inverter: Series
3000W True Sine Wave DC-AC Inverter: Series
■ Features :
True sine wave output (THD<3%)
High surge power up to 6000W
High efficiency up to 92%
Power ON-OFF switch
Standby saving mode can be selectable
Front panel indicator for operation status
Thermostatically controlled cooling fan
Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp.
/ Output short / Input polarity reverse / Overload / AC circuit breaker
Application : Home appliance, power tools, office and portable
equipment, vehicle and yacht ...etc.
Optional monitoring software and connection cable
(MW order No.: DS-TN-1500)
3 years warranty E13
SPECIFICATION
MODEL TS-3000-112□ TS-3000-124□ TS-3000-148□ TS-3000-212□ TS-3000-224□ TS-3000-248□
RATED POWER (Typ.) 3000W
MAXIMUM OUTPUT POWER (Typ.) 3450W for 180 sec. / 4500W for 10 sec. / surge power 6000W for 30 cycles
Factory setting set at 110VAC Factory setting set at 230VAC
AC VOLTAGE
100 / 110 / 115 / 120VAC selectable by setting button S.W 200 / 220 / 230 / 240VAC selectable by setting button S.W
FREQUENCY 60±0.1Hz 50/60Hz selectable by setting button S.W 50±0.1Hz 50/60Hz selectable by setting button S.W
OUTPUT
WAVEFORM Note.7 True sine wave (THD<3%)
AC REGULATION (Typ.) ±3%
SAVING MODE (Typ.) Default disabled. Load≦5W will be changed to standby mode
FRONT PANEL INDICATOR Battery voltage level, output load level, saving mode, fault and operation status
BAT. VOLTAGE 12V 24V 48V 12V 24V 48V
VOLTAGE RANGE (Typ.) Note.3,6 10.5 ~ 15VDC 21 ~ 30VDC 42 ~ 60VDC 10.5 ~ 15VDC 21 ~ 30VDC 42 ~ 60VDC
DC CURRENT (Typ.) Note.4 300A 150A 75A 300A 150A 75A
INPUT NO LOAD DISSIPATION (Typ.) ≦10W @ standby saving mode
OFF MODE CURRENT DRAW (Typ.) ≦1mA
EFFICIENCY (Typ.) Note.1 88% 90% 91% 89% 91% 92%
BATTERY TYPES Open & sealed lead acid battery
FUSE 40A*12 40A*6 20A*6 40A*12 40A*6 20A*6
BATTERY BAT. LOW ALARM Note.6 11.3V 22.5V 45V 11.3V 22.5V 45V
INPUT
PROTECTION BAT. LOW SHUTDOWN Note.6 10.5V 21V 42V 10.5V 21V 42V
REVERSE POLARITY By internal fuse open
90℃± 5℃ 85℃± 5℃ 85℃± 5℃ 80℃± 5℃ 75℃± 5℃ 75℃± 5℃
OVER TEMPERATURE
Protection type : Shut down o/p voltage, re-power on to recover
OUTPUT SHORT Protection type : Shut down o/p voltage, re-power on to recover
OUTPUT 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec.
PROTECTION OVER LOAD (Typ.)
Protection type : Shut down o/p voltage, re-power on to recover
CIRCUIT BREAKER AC output receptacle:15A
GFCI PROCTECTION Optional (Only type F) None
WORKING TEMP. Note.2 0 ~ +40℃ @ 100% load ; 60℃ @ 50% load
WORKING HUMIDITY 20% ~ 90% RH non-condensing
ENVIRONMENT
STORAGE TEMP., HUMIDITY -30 ~ +70℃ / -22 ~ +158oF, 10 ~ 95% RH non-condensing
VIBRATION 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS UL458 (only for Type G ), EAC TP TC 004 EAC TP TC 004
LVD None EN60950-1
SAFETY & WITHSTAND VOLTAGE Bat I/P - AC O/P:3.0KVAC AC O/P - FG:1.5KVAC
EMC ISOLATION RESISTANCE Bat I/P - AC O/P, Bat I/P - FG, AC O/P - FG: 100M ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION Compliance to FCC class A, EAC TP TC 020 Compliance to EN55032 class A, 72/ 245/ CEE, 95/ 54/ CE, E-Mark, EAC TP TC 020
EMC IMMUNITY Compliance to EAC TP TC 020 Compliance to EN61000-4-2,3,4,5,6,8,11, EAC TP TC 020
CONTROL WIRING RJ11 -RS232 (Option)
OTHERS DIMENSION 466.8*283.5*100mm (L*W*H)
PACKING 12.9Kg; 1pcs/14Kg/1.49CUFT
NOTE 1.Efficiency is tested by 2100W, linear load at 13V, 26V, 52V input voltage.
2.Output derating capacity referenced by curve 1.
3.Input derating capacity referenced by curve 2.
4.DC current is tested by 3000W, linear load at 12V, 24V, 48V input voltage.
5.All parameters not specified above are measured at rated load, 25℃ of ambient temperature and set to factory setting.
6.The tolerance of each voltage value by models is:112/212→±0.5V;124/224→±1V;148/248→±2V.
7.THD is tested by 3000W, linear load at 13,26,52V input voltage.
8.Please do not turn on the inverter before start the engine if inverter connect to vehicle’s battery directly.
9.The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
File Name:TS-3000-SPEC 2018-01-15
3000W True Sine Wave DC-AC Inverter TS-3000 series
Receptacle type
(Terminal only)
TYPE-A TYPE-B TYPE-C TYPE-D TYPE-E TYPE-F TYPE-G
Country USA EUROPE AUSTRALIA U.K JAPAN GFCI -----
80
31.6
LOAD (%)
60
100
POS
40
NEG
Unit.
Will Damage The
Reverse Polarity
20
0 10 20 30 40 50 60 70
direction direction
100
80
LOAD (%)
90.3
60
7.5
40
7
20
466.8
AC Receptacle
ON
OFF
BATTERY LOAD
100 100
INVERTER Setting
i t Br e
cu
ak
r
On
Ci
er
0
0
Pr
Bat Low
se
s
e
s e
t o R
Saving
Chassis Cat.No.(1GG1HS-212)
Wire Range(10-4 AWG Str
Ground Cu Soldered Wires)
Torque (17.7-26.5 in lb)
Remote
port
13
AC OUTPUT
31.29
Type-A
AC Receptacle
ON
OFF
BATTERY LOAD
100 100
INVERTER Setting
i t Br e
12
cu
ak
r
On
Ci
er
0
34
0
Pr
Bat Low
se
s
e
s e
t o R
Saving
Chassis Cat.No.(1GG1HS-212)
Wire Range(10-4 AWG Str
Ground Cu Soldered Wires)
Torque (17.7-26.5 in lb)
273 Remote
port
13
283.5 AC OUTPUT
31.29
Type-B