DGCA & EASA Module 15: Part-17 Engine Fire Protection System
DGCA & EASA Module 15: Part-17 Engine Fire Protection System
DGCA & EASA Module 15: Part-17 Engine Fire Protection System
8. What is the operating principle of the spot detector sensor in a fire detection system?.
A. A conventional thermocouple that produces a current flow.
B. A bimetallic thermoswitch that closes when heatedto a high temperature.
C. Resistant core material that prevents current flow at normal temperatures.
Ans : A bimetallic thermoswitch that closes when heatedto a high temperature.
Explanation: Jeppesen A&P Powerplant Textbook 11-2.
9. In a fixed fire-extinguishing system, there are two small lines running from the system and exiting
overboard. These line exit ports are covered with a blowout type indicator disc. Which of the following
statements is true?.
A. When the red indicator disc is missing, it indicates the fire extinguishing system has been normally
discharged.
B. When the green indicator disc is missing, it indicates the fire extinguishing system has had a
thermal discharge.
C. When the yellow indicator disc is missing, it indicates the fire extinguishing system has been
normally discharged.
Ans : When the yellow indicator disc is missing, it indicates the fire extinguishing system has been
normally discharged.
Explanation: NIL.
10. Two continuous-loop fire detection systems that will not test due to a brokendetector element are
the.
A. thermocouple system and the Lindberg system.
B. Kidde system and the Fenwal system.
C. Kidde system and the Lindberg system.
Ans : Kidde system and the Fenwal system.
Explanation: Jeppesen A&P Powerplant Textbook 16-15.
11. Which of the following fire detection systems measures temperature rise compared to a reference
temperature?.
A. Lindberg continuous element.
B. Thermocouple.
C. Thermal switch.
Ans : Thermocouple.
Explanation: Jeppesen A&P Powerplant Textbook 11-4.
13. How are most aircraft turbine engine fire extinguishing systems activated?.
A. Manual remote control valve.
B. Pushrod assembly.
C. Electrically discharged cartridges.
Ans : Electrically discharged cartridges.
Explanation: NIL.
14. A fire detection system that operates on the rate of temperature rise is a.
A. thermocouple system.
B. thermal switch system.
C. continuous loop system.
Ans : thermocouple system.
Explanation: NIL.
15. Why does one type of Fenwal fire detection system use spot detectors wired in parallel between
two separate circuits?.
A. So that a single fault may exist in the system without sounding a false alarm.
B. To provide an installation that is equal to two separate systems: a primary system and a
secondary, or back-up system.
C. So that a double fault may exist in the system without sounding a false alarm.
Ans : So that a single fault may exist in the system without sounding a false alarm.
Explanation: NIL.
16. How does carbon dioxide (CO2) extinguish an aircraft engine fire?.
A. By lowering the temperature to a point where combustion will not take place.
B. The high pressure spray lowers the temperature and blows out the fire.
C. Contact with the air converts the liquid into snow and gas which smothers the flame.
Ans : Contact with the air converts the liquid into snow and gas which smothers the flame.
Explanation: NIL.
18. Which of the following is the safest fire extinguishing agent to use from a standpoint of toxicity and
corrosion hazards?
A. Bromotrifluoromethane (Halon 1301).
B. Bromochlorodifluoromethane (Halon 1211).
C. Dibromodifluoromethane (Halon 1202).
Ans : Bromotrifluoromethane (Halon 1301).
Explanation: NIL.
19. The explosive cartridge in the discharge valve of a fire extinguisher container is.
A. not a life dated unit.
B. a life dated unit.
C. mechanically fired.
Ans : a life dated unit.
Explanation: Jeppesen A&P Technician Airframe Textbook 16-22.
20. A fire detection system operates on the principle of a buildup of gas pressure within a tube
proportional to temperature. Which of the following systems does this statement define?.
A. Thermal switch system.
B. Lindberg continuous element system.
C. Kidde continuous loop system.
Ans : Lindberg continuous element system.
Explanation: Jeppesen A&P Technician Powerplant Textbook 11-16.
21. The most satisfactory extinguishing agent for an intake fire is.
A. methyl bromide.
B. dry chemical.
C. carbon dioxide.
Ans : dry chemical.
Explanation: Jeppesen A&P Technician Propulsion Textbook 16-22.
22. How is the fire extinguishing agent distributed in the engine section?.
A. Spray nozzles and perforated tubing.
B. Spray nozzles and fluid pumps.
C. Nitrogen pressure and slinger rings.
Ans : Spray nozzles and perforated tubing.
Explanation: Jeppesen A&P Technician Propulsion Textbook 16-22.
23. What is the principle of operation of the continuous loop fire detector system sensor?.
A. Core resistance material which prevents current flow at normal temperatures.
B. A bimetallic thermoswitch which closes when heated to a high temperature.
C. Fuse material which melts at high temperatures.
Ans : Core resistance material which prevents current flow at normal temperatures.
Explanation: Jeppesen A&P Technician Propulsion Textbook 11-5.
24. The fire detection system that uses a single wire surrounded by a continuous string of ceramic
beads in a tube is the.
A. Kidde system.
B. thermocouple system.
C. Fenwal system.
Ans : Fenwal system.
Explanation: Jeppesen A&P Technician Propulsion Textbook 11-5.
25. The fire detection system that uses two wires imbedded in a ceramic core within a tube is the.
A. Lindberg system.
B. Kidde system.
C. Fenwal system.
Ans : Kidde system.
Explanation: Jeppesen A&P Technician Propulsion Textbook 11-5.
27. Which of the following fire detection systems will detect a fire when an element is inoperative but
will not test when the test circuit is energized?.
A. The Kidde system and the Fenwal system.
B. The thermocouple system and the Lindberg system.
C. The Kidde system and the thermocouple system.
Ans : The Kidde system and the Fenwal system.
Explanation: Jeppesen A&P Technician Propulsion Textbook 11-5.
28. After a fire is extinguished, or overheat condition removed in aircraft equipped with a Systron-
Donner fire detector, the detection system.
A. must be manually reset.
B. automatically resets.
C. sensing component must be replaced.
Ans : automatically resets.
Explanation: Jeppesen A&P Technician Propulsion Textbook 11-7.
29. For fire detection and extinguishing purposes, aircraft powerplant areas are divided into fire zones
based on.
A. the volume and smoothness of the airflow through enginecompartments.
B. engine type and size.
C. hot and cold sections of the engine.
Ans : hot and cold sections of the engine.
Explanation: NIL.
Click Here For : DGCA & EASA Module 15 : Part-18 Engine Monitoring and
Ground Operation Question
30. What is the function of a fire detection system?.
A. To discharge the powerplant fire extinguishing system at the origin of the fire.
B. To activate a warning device in the event of a powerplant fire.
C. To identify the location of a powerplant fire.
Ans : To activate a warning device in the event of a powerplant fire.
Explanation: NIL.
31. What retains the nitrogen charge and fire extinguishing agent in a high rate of discharge (HRD)
container?.
A. Pressure gauge and cartridge.
B. Breakable disk or fusible disk.
C. Pressure switch and check tee valve.
Ans : Breakable disk or fusible disk.
Explanation: Jeppesen A&P Technician Propulsion Textbook 11-15.
33. The pulling out (or down) of an illuminated fire handle in a typical large jet aircraft fire protection
system commonly accomplishes what events?.
A. Closes fuel shutoff, closes hydraulic shutoff, disconnects the generator field, and arms the fire
extinguishing system.
B. Closes fuel shutoff, closes hydraulic shutoff, closes the oxygen shutoff, disconnects the generator
field, and arms the fire-extinguishing system.
C. Closes all firewall shutoff valves, disconnects the generator, and discharges a fire bottle.
Ans : Closes fuel shutoff, closes hydraulic shutoff, disconnects the generator field, and arms the fire
extinguishing system.
Explanation: NIL.
34. The most satisfactory extinguishing agent for an electrical fire is.
A. carbon tetrachloride.
B. methyl bromide.
C. carbon dioxide.
Ans : carbon dioxide.
Explanation: Jeppesen A&P Technician Propulsion Textbook 11-13
35. Which of the following fire detectors are commonly used in the power section of an engine
nacelle?.
A. Rate of temperature rise detectors.
B. CO detectors.
C. Smoke detectors.
Ans : Rate of temperature rise detectors.
Explanation: Jeppesen A&P Technician Propulsion Textbook 11-3.
36. Which of the following fire detection systems uses heat in the normal testing of the system?.
A. The Kidde system and the Fenwal system.
B. The thermocouple system and the Lindberg system.
C. The thermocouple system and the Fenwal system.
Ans : The thermocouple system and the Lindberg system.
Explanation: Jeppesen A&P Technician Propulsion Textbook 11-5.
37. How are extinguisher spray rings checked for freedom from obstruction?.
A. Firing the system.
B. Blowing through with compressed air.
C. Pumping water through the system.
Ans : Blowing through with compressed air.
Explanation: Answer a is the only reasonable answer.
39. The advantage of the two shot fire bottle system is.
A. one bottle can be discharged after certain time delay from the other bottle.
B. both bottles can be used in either of the engines.
C. one bottle can be used twice.
Ans : both bottles can be used in either of the engines.
Explanation: Jeppesen Gas Turbine Engines 13-6 refers. Note that each bottle can only be
discharged once.
45. When installing a flow valve on a 'two shot' fire extinguishing system care must be taken to make
sure.
A. flow arrow should be in a correct direction.
B. flow valve is pointing towards the respective bottle.
C. priority system must have the bigger flow side.
Ans : flow arrow should be in a correct direction.
Explanation: Two shot systems do not have any priority. Any flow valve must be fitted in the right
direction which is toward the engine not the bottle!.
46. Omission of crushable washer on engine fire-wire connector will.
A. allow moisture ingress.
B. affect fire wire continuity.
C. affect fire wire capacitance.
Ans : allow moisture ingress.
Explanation: Jeppesen A&P power plant page 11-10 refers to copper crush washers at the
connectors. Answers a and c cannot be right therefore b makes best sense.
48. The Kidde Fault Free Fire detection system has how many internal wires in the sensing element?.
A. 1.
B. 3.
C. 2.
Ans : 2.
Explanation: Jeppesen Gas Turbine Powerplants Page 12-5 Refers.
51. On a fire bottle, if the indicator pin was protruding, this would indicate.
A. the bottle is under weight.
B. extinguisher had been fired.
C. an over pressure had occurred in the bottle.
Ans : extinguisher had been fired.
Explanation: C.A.I.P's AL/3-10 describes and shows a discharge indicator pin device.
Click Here For : DGCA & EASA Module 15 : Part-18 Engine Monitoring and
Ground Operation Question
Email ThisBlogThis!Share to TwitterShare to Facebook