0% found this document useful (0 votes)
50 views6 pages

HW-MS7120 Config Pages

Metrologic scanners can be configured using either a single-code or multi-code method. The single-code method involves powering up the scanner and scanning a single bar code to enable or disable features, while the multi-code method requires scanning an entry/exit code before and after scanning codes for multiple features. The document then provides bar codes to configure settings for standard suffixes, UPC/EAN formatting and transmission, and GTIN-14 format.

Uploaded by

Narbig1
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
50 views6 pages

HW-MS7120 Config Pages

Metrologic scanners can be configured using either a single-code or multi-code method. The single-code method involves powering up the scanner and scanning a single bar code to enable or disable features, while the multi-code method requires scanning an entry/exit code before and after scanning codes for multiple features. The document then provides bar codes to configure settings for standard suffixes, UPC/EAN formatting and transmission, and GTIN-14 format.

Uploaded by

Narbig1
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Bar Code Configuration Methods xii

BAR CODE CONFIGURATION METHODS

Metrologic scanners can be bar code configured in two ways: the Single-Code Method
and the Multi-Code Method.

Single-Code Method

Most features can be enabled or disabled using the Single-Code Method.

1. Power up the scanner.


2. Scan the bar code(s) for the desired feature(s).
3.
been saved to NOVRAM.

Multi-Code Method

All features can be enabled or disabled using the Multi-Code Method.

1. Power up the scanner.


2. Scan the Enter/Exit Configuration Mode bar code. [3 beeps]
3. Scan the bar code(s) for the desired feature(s). [1 beep]
4. Scan the Enter/Exit Configuration Mode bar code [3 beeps] and
save new configuration.

Enter/Exit Configuration Mode

³ 9 9 9 9 9 9

To abort a configuration change, power off the scanner before scanning the
Enter/Exit Configuration Mode bar code.
Prefixes/Suffixes E 14

SECTION E STANDARD SUFFIX CHARACTERS

* Enable CR Suffix Disable CR Suffix

³ 1 1 6 6 1 3 ³ 1 1 6 6 0 3

The scanner will transmit a The scanner will not


Carriage Return after each transmit a Carriage Return
bar code. after each bar code.

* Enable LF Suffix Disable LF Suffix

³ 1 1 6 6 1 2 ³ 1 1 6 6 0 2

The scanner will transmit a The scanner will not


Line Feed after each bar transmit a Line Feed after
code. each bar code.

This feature is
Disabled when
keyboard wedge
defaults are loaded.

Enable Tab Suffix * Disable Tab Suffix

³ 1 1 6 6 1 0 ³ 1 1 6 6 0 0

The scanner will transmit a The scanner will not


TAB (ASCII 09H) after each transmit a TAB (ASCII 09H)
bar code. after each bar code.
SECTION F UPC/EAN

* Transmit UPC-A Do not Transmit


Check Digit UPC-A Check Digit

³ 1 0 7 5 1 7 ³ 1 0 7 5 0 7

Transmit UPC-E * Do Not Transmit


Check Digit UPC-E Check Digit

³ 1 0 7 5 1 6 ³ 1 0 7 5 0 6

* Do Not Expand
Expand UPC-E to 12 Digits UPC-E To 12 Digits

³ 1 0 7 5 1 5 ³ 1 0 7 5 0 5

Expand UPC-E bar codes to Do not expand UPC-E to the


the 12 digit equivalent, 12 digit equivalent, UPC-A
UPC-A bar codes. bar code.

Code Formatting F 1
Code Formatting F 2

SECTION F UPC/EAN

* Do Not Convert
Convert UPC-A to EAN-13 UPC-A to EAN-13

³ 1 0 7 5 1 4 ³ 1 0 7 5 0 4

The scanner converts The scanner will not convert


UPC-A to EAN-13 by UPC-A to EAN-13.
transmitting a leading zero
before the bar code.

Transmit Lead Zero Do Not Transmit


on UPC-E Lead Zero on UPC-E

³ 1 0 7 5 1 3 ³ 1 0 7 5 0 3

This option will transmit a This option will not transmit


zero before each a zero before each UPC-E
UPC-E bar code. bar code.

* Do Not Convert
Convert EAN-8 to EAN-13 EAN-8 to EAN-13

³ 1 0 7 5 1 2 ³ 1 0 7 5 0 2

The scanner will transmit The scanner will not convert


five zeros before the bar EAN-8 to EAN-13.
code to convert EAN-8 to
EAN-13.
SECTION F UPC/EAN

* Transmit UPC-A Do Not Transmit UPC-A


Number System Number System

³ 1 0 7 5 1 1 ³ 1 0 7 5 0 1

Metrologic strongly
discourages using
this feature.
Duplicate numbers
may result in the
database.

* Transmit Do Not Transmit


UPC-A MFR # UPC-A MFR #

³ 1 0 7 6 1 1 ³ 1 0 7 6 0 1

* Transmit Do Not Transmit


UPC-A ITEM # UPC-A ITEM #

³ 1 0 7 6 1 0 ³ 1 0 7 6 0 0

Code Formatting F 3
Code Formatting F 4

SECTION F UPC/EAN

* Transmit EAN-8 Do Not Transmit


Check Digit EAN-8 Check Digit

³ 1 0 7 9 1 0 ³ 1 0 7 9 0 0

* Transmit EAN-13 Do Not Transmit


Check Digit EAN-13 Check Digit

³ 1 0 7 9 1 2 ³ 1 0 7 9 0 2

GTIN-14 Format No GTIN-14 Format

³ 1 0 7 5 1 0 ³ 1 0 7 5 0 0

This feature is not


available with all
models.