Boia Flygt 2012-01 - TS - ENM-10

Download as pdf or txt
Download as pdf or txt
You are on page 1of 14

Technical

specification

ENM-10 Level regulator


Table of Contents

Table of Contents
PRODUCT DESCRIPTION......................................................................................................................2
Product description.............................................................................................................................2

CHEMICAL RESISTANCE LIST.............................................................................................................. 6


Chemical resistance list...................................................................................................................... 6

PRODUCT RANGE................................................................................................................................. 8
Product range...................................................................................................................................... 8

ENM-10 Level regulator Technical specification 1


PRODUCT DESCRIPTION

PRODUCT DESCRIPTION
Product description
The simplest possible method for level control! A mechanical switch in a plastic casing,
freely suspended at the desired height from its own cable. When the liquid level reaches
the regulator, the casing will tilt and the mechanical switch will close or break the circuit,
thereby starting or stopping a pump or actuating an alarm device. No wear, no
maintenance! In sewage pumping stations, for ground water and drainage pumping — in
fact, for most level control applications — the ENM-10 is the ideal solution.
The regulator casing is made of polypropylene and the cable is sheathed with a special
PVC or Nitrile/PVC rubber compound. The plastic components are welded and screwed
together. Adhesive is never used. Impurities and deposits will not adhere to the smooth
casing.
This level regulator is available in different versions, depending upon the medium in which
it is to be used. As standard, the regulator can be obtained with 6, 13, 20, 30 or 50 metres
(20, 42, 65, 100 or 167 feet) of cable for liquids with specific density between 0.95 and
1.10 g/cm3; for other specific densities and for the Ex-version, the regulator is only
available with 20 metres (65 ft) of cable. The regulator can withstand up to 60°C (140°F).
Technical data
Liquid temperature: min. 0°C (32°F)
max. 60°C (140°F)

Liquid density: min. 0.65 g/cm3


max. 1.5 g/cm3

Degree of protection: IP68, 20 m (65 ft)

Interrupting capacity of micro switch: AC, resistive load, 250V 10A


AC, inductive load, 250V 3A
cos ϕ = 0.5
DC, 30V 5A

With gold plated micro switch: same as above, except:


DC, 24V 10mA
Note that local regulations may limit the voltage.
Materials
Body: Body:

Bending relief: EPDM rubber

Cable: special compound PVC or NBR/PVC nitrile/PVC rubber

Dimensions
Table 1

For density g/cm3 Regulator length mm (in.) Diameter mm (in.)


0.65—0.80 194 (7 10/16) 100 (4)
0.80—0.95 177 (7) 100 (4)
0.95—1.10 162 (6 3/8) 100 (4)
1.05—1.20 142 (5 9/16) 100 (4)
1.20—1.30 133 (5 1/4) 100 (4)

2 ENM-10 Level regulator Technical specification


PRODUCT DESCRIPTION

For density g/cm3 Regulator length mm (in.) Diameter mm (in.)


1.30—1.40 130 (5 2/16) 100 (4)
1.40—1.50 126 (5) 100 (4)

Weight: approx. 2 kg (4.5 lb) for a standard density regulator with 20 m cable.
Approvals: CE, CSA, SEMKO, NEMKO, DEMKO
LVD approval according to EN61058
CSA approval: Cert no. 1330172
Cl.I Zone 0, Gr. IIC;
CL.I Div.1 Gr A, B, C&D;
Cl.II Gr. E, F&G;
Cl.III when installed to the certified Intrinsically Safe relay, Ex ia, rated for the locations per
submitter controll drawing and installation manual.
Intrincically safe circuits are required for the automatic control system. - Use a EX-safety
barrier (e.g. Prod. no. 84 01 07).

0080
Figure 1

Wiring alternative
To conform to local regulations, the level regulators are normally connected through a
transformer to a low-tension control circuit.
Two regulators are used; one for starting and one for stopping. A third regulator can be
connected if an alarm is required at a given level.
Identical regulators can be used for all functions.

M3 M3

M2 M2

M1 M1
24V 24V

Start Stop

Stop Start

Connect the gray and black leads. Connect the gray and brown leads.

ENM-10 Level regulator Technical specification 3


PRODUCT DESCRIPTION

Insulate the brown lead. Insulate the black lead.


Figure 2: Connected for emptying Figure 3: Connected for emptying

Figure 4

Figure 5: Colour code

Maintenance and repair


ENM-10 is very durable and practically maintenance free. You only have to check on it
occasionally, to ensure its continual operation.
• It is recommended to occasionally clean ENM-10, and especially when fat/grease
covers the plastic surface.
• At the same time, make an occular inspection of the regulator to make sure neither
cable, protective sleeve or plastic casing show any signs of damage.

4 ENM-10 Level regulator Technical specification


PRODUCT DESCRIPTION

• A damaged ENM-10 cannot be repaired in any way, due to the hermetic


encapsulation. If the unit is found to be damaged, replace it with a new one.
• For Ex-installations, also make absolutely sure that the Ex-barrier (e.g. Prod. no. 84 01
07) is operating correctly - The LED changes when the switch is toggled.
The manufacturers reserve the right to alter performance specification or design without
notice.

ENM-10 Level regulator Technical specification 5


CHEMICAL RESISTANCE LIST

CHEMICAL RESISTANCE LIST


Chemical resistance list
The liquid in which level regulation is practiced most frequently is, of course, water. Of the
millions of regulators in use all over the world today, it is estimated that nine out of ten
work in water.
However, with a float body of polypropylene, a cable of PVC or NBR/PVC nitrile/PVC
rubber and a bending relief of EPDM rubber, the ENM-10 is virtually insensitive to many
aggressive liquids.
The table shows how resistant the ENM-10 equipped with either PVC or NBR/PVC
nitrile/PVC rubber cable, is to different chemicals at two different temperatures.
The classification is broken down into the following categories:
0 = No effect, 1 = Minor to moderate and 2 = Severe effect. The sign — means that
information is not available.
Keep in mind also that the density of the liquid determines the bouyancy of the regulator.
The ENM-10 is made for seven different densities. See Product description (page 2).
Always observe local regulations:

6 ENM-10 Level regulator Technical specification


CHEMICAL RESISTANCE LIST

Take particular note of:


• risk of fire/explosion
• hygiene requirements
PVC cable NBR/PVC PVC cable NBR/PVC PVC cable NBR/PVC
nitrile/PVC nitrile/PVC Solvents and nitrile/PVC
Acids rubber cable Salts rubber cable miscellaneous rubber cable

20°C 60°C 20°C 60°C 20°C 60°C 20°C 60°C 20°C 60°C 20°C 60°C
(68°F) (140°F) (68°F) (140°F) (68°F) (140°F) (68°F) (140°F) (68°F) (140°F) (68°F) (140°F)

Acetic Acid 50% 1 2 0 0 Aluminium Chloride 0 0 0 0 Aceton 2 2 2 2


Acetic Acid 75% 2 2 0 0 Calcium Sulphate 0 0 0 0 Aniline 2 2 1 2
Benzoic Acid 2 2 0 0 Calcium Chloride 0 0 0 0 Benzene 2 2 2 2
Boric Acid 5% 0 — 0 0 Calcium Nitrate 0 0 0 0 Butyl Alcohol 2 2 0 1
Butyric Acid 2 2 2 2 Copper Chloride 0 0 0 0 Carbon
Tetrachloride 2 2 2 2
Chromic Acid 10% 0 2 2 2 Copper Sulphate 0 0 0 0
Citric Acid 0 1 0 0 Ferric Chloride 0 0 0 0 Chlorobenzene 2 2 2 2
Hydrobromic Ferrous Sulphate 0 0 0 0 Chloroform 2 2 2 2
Acid 5% 1 2 0 0 Magnesium Chloride 0 0 0 0 Ethyl Alcohol 2 2 0 1
Hydrochloric Potassium Sulphate 0 0 0 0 Ethyl Ether 2 2 2 2
Acid 10% 0 1 0 1 Ethyl Acetate 2 2 2 2
Hydrochloric Potassium Nitrate 0 0 0 0
Acid 37% 1 2 0 2 Potassium Ethylene Dichloride 2 2 2 2
Carbonate 1 1 1 1 Ethylene Chloride 2 2 2 2
Hydrocyanic Potassium Formaldehyde 37% 1 2 0 0
Acid 10% 0 0 1 2 Bicarbonate 0 0 0 0 Gasoline 2 2 2 2
Kerosene 2 2 2 2
Acid 5% 0 2 0 1 Sodium Sulphate 0 0 0 0
Hypochloric Acid 1 2 2 2 Sodium Chloride 0 0 0 0 Methyl Alcohol 2 2 0 0
Maleic Acid 2 2 2 2 Sodium Nitrate 0 0 0 0 Methyl Ethyl Ketone 2 2 2 2
Nitric Acid 5% 1 1 1 1 Sodium Bicarbonate 0 0 0 0 Methylene Chloride 2 2 2 2
Sodium Carbonate 0 0 0 0 Nitrobenzene 2 2 2 2
Nitric Acid 65% 2 2 2 2 Phenol 2 2 2 2
Oleic Acid 1 2 2 2 Tin Chloride 1 1 1 1
Oxalic Acid 50% 1 1 1 2 Zinc Sulphate 0 0 0 0 Toluene 2 2 2 2
Phosphoric Zinc Chloride 0 0 0 0 Trichlorethylene 2 2 2 2
Acid 25% 0 0 1 2 Turpentine 2 2 2 2
Phosphoric Oils Xylene 2 2 2 2
Acid 85% 0 0 1 2
Castor Oil 1 1 1 1
Sulphuric Acid 10% 1 2 1 2 Cocoanut Oil 0 — 0 2 Gases
Sulphuric Acid 78% 2 2 2 2 Corn Oil 2 2 2 2
Tannic Acid 0 0 0 0 Diesel Oil 2 2 2 2 Carbon Dioxide 0 0 0 0
Tartaric Acid 1 1 1 1 Carbon Monoxide 0 0 0 0
Linseed Oil 2 2 2 2 Chlorine (wet) 2 2 2 2
Bases Mineral Oils 2 2 2 2 Hydrogen Sulphide 0 0 1 1
Olive Oil 1 1 1 1 Sulphur Dioxide
Ammonium Silicone Oils 0 0 0 0 (wet) 1 1 2 2
Hydroxide 0 — 0 0
Calcium Hydroxide 0 0 0 0
Potassium
Hydroxide 1 2 0 0
Sodium Hydroxide 1 2 0 0

0 = No effect, 1 = Minor to moderate, 2 = Severe effect. — = No information available.


Figure 6

ENM-10 Level regulator Technical specification 7


PRODUCT RANGE

PRODUCT RANGE
Product range
Part no. For Color of Type of Cable Approvals For market Notes
density level cable length [m]
[g/cm³] switch
5828800 0,65-0,80 Blue 1 20 CE
5828801 0,80-0,95 Blue 1 20 CE
5828802 0,95-1,10 Blue 1 6 CE
5828803 0,95-1,10 Blue 1 13 CE
5828804 0,95-1,10 Blue 1 20 CE
5828805 1,05-1,20 Blue 1 20 CE
5828806 1,2-1,3 Blue 1 20 CE
5828807 1,3-1,4 Blue 1 20 CE
5828808 1,4-1,5 Blue 1 20 CE
5828809 0,65-0,80 Grey 5 20 CSA/CE Canada
5828810 0,80-0,95 Grey 5 20 CSA/CE Canada
5828811 0,95-1,10 Grey 5 6 CSA/CE Canada
5828812 0,95-1,10 Grey 5 13 CSA/CE Canada
5828813 0,95-1,10 Grey 5 20 CSA/CE Canada
5828814 1,05-1,20 Grey 5 20 CSA/CE Canada
5828815 1,2-1,3 Grey 5 20 CSA/CE Canada
5828816 1,3-1,4 Grey 5 20 CSA/CE Canada
5828817 1,4-1,5 Grey 5 20 CSA/CE Canada
5828818 0,65-0,80 Grey 1 20 CSA/CE Canada
5828819 0,80-0,95 Grey 1 20 CSA/CE Canada
5828820 0,95-1,10 Grey 1 6 CSA/CE Canada
5828821 0,95-1,10 Grey 1 13 CSA/CE Canada
5828822 0,95-1,10 Grey 1 20 CSA/CE Canada
5828823 1,05-1,20 Grey 1 20 CSA/CE Canada
5828824 1,2-1,3 Grey 1 20 CSA/CE Canada
5828825 1,3-1,4 Grey 1 20 CSA/CE Canada
5828826 1,4-1,5 Grey 1 20 CSA/CE Canada
5828827 0,65-0,80 Blue 2 20 CE USA
5828828 0,80-0,95 Blue 2 20 CE USA
5828829 0,95-1,10 Blue 2 6 CE USA
5828830 0,95-1,10 Blue 2 13 CE USA
5828831 0,95-1,10 Blue 2 20 CE USA
5828832 1,05-1,20 Blue 2 20 CE USA
5828833 1,2-1,3 Blue 2 20 CE USA
5828834 1,3-1,4 Blue 2 20 CE USA
5828835 1,4-1,5 Blue 2 20 CE USA
5828836 0,95-1,10 Grey 5 30 CSA/CE Canada
5828837 0,95-1,10 Grey 5 50 CSA/CE Canada
5828838 0,95-1,10 Grey 5 100 CSA/CE Canada
5828839 0,95-1,10 Grey 5 150 CSA/CE Canada
5828851 0,95-1,10 Red 3 65 CE
5828852 0,95-1,10 Red 3 6 CE
5828853 0,95-1,10 Red 3 13 CE
5828854 0,95-1,10 Red 3 20 CE
5828855 0,95-1,10 Red 3 6 CSA/CE Canada
5828856 0,95-1,10 Red 3 13 CSA/CE Canada
5828857 0,95-1,10 Red 3 20 CSA/CE Canada

Cont.
Figure 7

8 ENM-10 Level regulator Technical specification


PRODUCT RANGE

5828858 0,95-1,10 Red 4 6 CE USA


5828859 0,95-1,10 Red 4 13 CE USA
5828860 0,95-1,10 Red 4 20 CE USA
5828870 0,65-0,80 Blue 5 20 CE
5828871 0,80-0,95 Blue 5 20 CE
5828872 0,95-1,10 Blue 5 6 CE
5828873 0,95-1,10 Blue 5 13 CE
5828874 0,95-1,10 Blue 5 20 CE
5828875 1,05-1,20 Blue 5 20 CE
5828876 1,2-1,3 Blue 5 20 CE
5828877 1,3-1,4 Blue 5 20 CE
5828878 1,4-1,5 Blue 5 20 CE
5828879 0,95-1,10 Blue 1 65 CE
5828880 0,95-1,10 Blue 1 30 CE
5828881 0,95-1,10 Blue 1 50 CE
5828882 0,95-1,10 Grey 1 30 CSA/CE Canada
5828883 0,95-1,10 Grey 1 50 CSA/CE Canada
5828884 0,95-1,10 Blue 2 30 CE USA
5828885 0,95-1,10 Blue 2 50 CE USA
5828886 0,95-1,10 Red 3 30 CE
5828887 0,95-1,10 Red 3 50 CE
5828890 0,95-1,10 Blue 5 30 CE
5828891 0,95-1,10 Blue 5 50 CE
5828892 0,95-1,10 Red 3 6 CE Japan
5828893 0,95-1,10 Red 3 13 CE Japan
5828894 0,95-1,10 Red 3 20 CE Japan
5828895 0,95-1,10 Blue 1 6 CE Japan
5828896 0,95-1,10 Blue 1 13 CE Japan
5828897 0,95-1,10 Blue 1 20 CE Japan
5828898 0,95-1,10 Blue 1 50 CE Japan
Designed for low current and
5947919 0,95-1,10 Blue 5 20 CE slow movements

Designed for low current and


5947920 0,95-1,10 Grey 5 20 CSA/CE slow movements

Type of c able :
1. Blue PVC jacket with color coding of wires: Grey/Brown/Black
2. Blue PVC jacket with color coding of wires: Red/White/Black
3. Red PVC jacket with color coding of wires: Grey/Brown/Black
4. Red PVC jacket with color coding of wires: Red/White/Black
5. BLACK NBR/PVC jacket with color coding of wires: Grey/Brown/Black (NBR=Nitrile rubber)

ENM-10 Level regulator Technical specification 9


Xylem |’zīləm|
1) The tissue in plants that brings water upward from the roots
2) A leading global water technology company

We're 12,000 people unified in a common purpose: creating


innovative solutions to meet our world's water needs. Developing new
technologies that will improve the way water is used, conserved, and
re-used in the future is central to our work. We move, treat, analyze,
and return water to the environment, and we help people use water
efficiently, in their homes, buildings, factories and farms. In more than
150 countries, we have strong, long-standing relationships with
customers who know us for our powerful combination of leading
product brands and applications expertise, backed by a legacy of
innovation.

For more information on how Xylem can help you, go to xyleminc.com

Xylem Water Solutions AB Visit our Web site for the latest version of this document and
more information
Gesällvägen 33
174 87 Sundbyberg The original instruction is in English. All non-English
instructions are translations of the original instruction.
Sweden
Tel. +46-8-475 60 00 © 2011 Xylem Inc

Fax +46-8-475 69 00
http://tpi.xyleminc.com

891480_11.1_en.GB_2012-01_TS_ENM-10