Particle Sensor

BENEFITS
Reduce Defects
• Real-time monitoring of defect-causing particles
• Proven technology provides reliable and accurate data
• Users can react immediately to particle contamination events
• Meets ISO 21501-4
Increase Productivity
• Low cost solution for multipoint monitoring
• Interfaces with Facility Net or Pharmaceutical Net
software for comprehensive management of
cleanroom conditions
• System validation documentation available
Cost Effective
The Airnet II particle sensor is the latest product that makes it easy and cost • Small footprint and flexible mounting options make it
effective to monitor your cleanroom for proper operation. These particle easy to install in cleanrooms and minienvironments
sensors offer a small footprint, unparalleled performance and data transmission • Easy to clean/wipe down; designed to minimize particle traps
capabilities while meeting the specification of ISO 21501-4. • Rugged, chemical resistant Polycarbonate (PC) enclosure
• Diode laser reduces maintenance
Installation is simplified with versatile power options such as the use of distributed • Automatic laser shutdown reduces laser failures
power from an in-house system, local power plug in capabilities and the ability to use
Power over Ethernet (PoE). Communication capabilities include the use of Ethernet • Data queue maintains data integrity when
communication is lost
communications to interface with Pharmaceutical Net or Facility Net, optional OPC
communications or the ability to provide an optional 4-20 mA output. • Power over Ethernet (PoE) simplifies installations
• Optional 4-20 mA output for integration with existing systems
Data integrity is maintained through the use of a data queue feature that will • Optional OPC communications reduces integration costs
continue to gather data even if communications is lost. These units incorporate
a Dynamic Flow Sensing system that will alarm with a 15% change in flow
• Optional XR coating protects sensor against corrosive or
oxidizing vapors
conditions to assure proper flow conditions and vacuum system operation.
APPLICATIONS
For situations where Vaporized Hydrogen Peroxide (VHP) is used for sterilization, • Cleanroom monitoring
an optional VHP compatible unit is available.
• Dedicated monitoring of critical locations
• Trend analysis
• Statistical process control
• Multi-location monitoring

Without measurement, there is no control.


Airnet II ®

Particle Sensor specifications


301/ 501/ 510/ 510XR/
301 OPC 501 OPC 510 OPC 510XR OPC
Size range (µm) 0.3, 0.5 0.5, 5.01 0.5, 5.0 0.5, 5.0
Flow rate 0.1 CFM 0.1 CFM 1.0 CFM 1.0 CFM
(2.8 LPM) (2.8 LPM) (28 LPM) (28 LPM)
Counting efficiency2 50% ± 20% for most sensitive channel. Meets ISO 21501-4
100% ± 10% at 1.5 to 2.0 times channel one size. Meets ISO 21501-4
Zero count ≤70.7counts/m3 ≤70.7counts/m3 ≤7.07counts/m3 ≤7.07counts/m3
Maximum concentration3 5,100,000/ft.3 8,600,000/ft.3 860,000/ft.3 860,000/ft.3
Laser source Diode
Laser classification Class 1 per EN60825 (Internally, a Class IIIB laser is used, per EN60825.)
Exterior surface Polycarbonate
Dimensions (l, w, h) 5.3 x 3.6 x 3.8 in. 5.3 x 3.6 x 3.8 in. 5.3 x 3.6 x 3.8 in. 5.3 x 3.6 x 3.8 in.
13.5 x 8.9 x 9.6 cm 13.5 x 8.9 x 9.6 cm 13.5 x 8.9 x 9.6 cm 13.5 x 8.9 x 9.6 cm
Weight 1.6 lbs. (.73 kg) 1.6 lbs. (.73 kg) 1.6 lbs. (.73 kg) 1.6 lbs. (.73 kg)
Sample probe or tubing 1/4” ID 1/4” ID 1/4” ID 1/4” ID
Flow system External vacuum 1/4” connection; automatic laser shutoff and alarm on 15% (±5%) flow variation.
Vacuum source >12 in. Hg >12 in. Hg >12 in. Hg >12 in. Hg
Power 24 VDC (0.5 A) 100-240 VAC ± 10%, 50-60 Hz, Power Supply (optional) or use of Power over Ethernet 48 VDC via a PoE router.
Communication connectors Ethernet requiring cable type CAT 5 UTP, and RS-232 (configuration and diagnostic tool only, no data) Data queue on loss of communications.
4-20 mA (optional) (three output channels: two particle data, one instrument status), Optional OPC communications available.

Status indicators Facility Net interface: Programmable status (two-color LED), Activity (one-color LED)
4-20 mA interface (optional): Laser and flow status (two-color LED), Activity (one-color LED)
OPC interface (optional): Laser and flow status (two-color LED), Activity (one-color LED)
Calibration Calibration materials used are traceable to the National Institute for Standards and Technology (NIST) and meet ISO 21501-4 requirements.
Environment Temperature: 4-35 °C, 5-95%: non-condensing relative humidity
1
Airnet 501A has 0.5 and 1.0 µm channels.
2
Allow 15% (± 5%) variations in sample flow.
3
10% coincidence loss at maximum concentration.
Airnet® is a registered trademark of Particle Measuring Systems, Inc.
US Patent 7088447. US Patents Pending.
Particle Measuring Systems, Inc. reserves the right to change specifications without notice.

AUTHORIZED REPRESENTATIVE
Registration applies to the Boulder, Colorado facility.

Particle Measuring Systems China


[email protected]
Particle Measuring Systems Europe Particle Measuring Systems Asia Pacific
Particle Measuring Systems Headquarters Tel: +44 1684 581000 [email protected] Particle Measuring Systems Mexico
5475 Airport Blvd., Boulder, CO 80301 [email protected] [email protected]
1-303-443-7100 1-800-238-1801 Fax: 1-303-546-7331 Particle Measuring Systems Singapore
Instrument Service & Support: 1-800-557-6363 Particle Measuring Systems Japan Tel: +65-6496 0330 Particle Measuring Systems Puerto Rico
Customer Response Center: 1-877-475-3317 [email protected] [email protected] [email protected]

© 2009 Particle Measuring Systems, Inc. All rights reserved. 1009V1.0