Ground Fault Sensor: CR7310 Series

The CR7310 Ground Fault Sensor provides a reliable and cost-effective way to sense ground faults by monitoring current flowing through wires. It has a variable trip point and time delay, and outputs a signal when the current reaches the trip level. Applications include monitoring electrical heaters, motors, and lamps. It is rated for currents from 10mA to 100A and has isolated circuits, LED indicators, and calibrated controls.

Uploaded by

bhaskarinvu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
107 views2 pages

Ground Fault Sensor: CR7310 Series

The CR7310 Ground Fault Sensor provides a reliable and cost-effective way to sense ground faults by monitoring current flowing through wires. It has a variable trip point and time delay, and outputs a signal when the current reaches the trip level. Applications include monitoring electrical heaters, motors, and lamps. It is rated for currents from 10mA to 100A and has isolated circuits, LED indicators, and calibrated controls.

Uploaded by

bhaskarinvu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Ground Fault Sensor

The CR7310 Series, Ground Fault Sensor provides a reliable


and cost effective method for sensing ground faults. The cur-
CR7310 Series rent-carrying wires are routed through the opening extending
from the top of the case. When ground current reaches the
level set by the trip point adjustment, the relay trips, illuminates
the tripped LED and provides an output signal. A precision
voltage reference circuit ensures a highly repeatable trip point.
The Sensor is rated as a Class 1 device.
Applications
Monitor Electrical Heater Elements
Sense Motor Over/Under Loads
Detect Lamp burn-out
Indicate Phase Loss

OUTPUT OPTIONS Features


Variable Trip Point and Time Delay
The Relay is available with three different ouput Monitors Currents from 10mAAC to 100 AAC Amps
configurations, electromechanical relay, op- Electrical Isolation Between Circuits
toisolated NPN transistor or zero-crossing op- Output Relay Rated up to 20 Amps
toisolated triac. Specify desired selection in part LED Trip Status Indicator
number. Dead Band Prevents Relay Chatter
Calibrated Dial Option Available
External Current Transformers Available
RELAY (-ELR)
Arrangement: 1 Form C (SPDT) Specifications

D Contact Material: Silver-cadmium oxide


Terminals: 31/4” Male QC
Mechanical Life: 10 million operations,
Mounting:
3/16” dia. clearance holes on 115/16” by 215/16”centers
Environmental:
typ.@ rated load
Operating Temperature: -30° C to +60° C
Electrical Life: 100,000 operations,
Storage Temperature: -55° C to +85° C
Relays, Switches & Sensors

typ. @ rated load


Initial Contact Resistance: Power-On Delay: 100 MS MAX
50 milliohms max. @ 500 mA, 12 VDC Hysteresis: 5% Max.
Contact Rating: UL508/873 & CSA Input Supply Power:
Typical 80mA Max 100mA
DC SWITCHING (-NPN) Sensed Current:
Vce (full off): 30 VDC max.
Max. Continuous: 200% Full Scale
Isink (full on): 120 mADC max.@ rated full-on Frequency: 60-400 Hz *
Vce (full on): 1.5 VDC @ 120 mADC Isink *All specifications for operation at 60 Hz only
Off state leakage current: 5ua @ 30 VDC Altitude: 2000 meters max.
(typical) (Contact factory for High Altitude applications)
Terminals: 21/4” Male Q C Weight 0.5 LBS.

AC SWITCHING (-TRC) Regulatory Agencies


Off state voltage: 240 VAC RMS max.
Minimum switch voltage: 24 VAC RMS E211244
On state current: 500 mA RMS max. continuous
VOLTAGE LOAD TYPE N.O. CONTACT N.C. CONTACT
Switching mode: Zero crossing
Off state leakage: 60 ua @ 240 VAC max. 240 VAC Resistive 20A 10A
Terminals: 2 @ 1/4” Male QC 240 VAC Motor 2HP 1/2 HP
125 VAC Motor 1HP 1/4 HP
28 VDC Resistive 20A 10A
The Professional
Energy Monitoring
Company
3500 Scarlet Oak Blvd. St. Louis MO USA 63122 V: 636-343-8518 F: 636-343-5119
M N TI
ISO 9001:2008 Quality Management System
Web: http://www.crmagnetics.com 66 E-mail: [email protected]
Ground Fault Sensor
OUTLINE DRAWING CR7310 Series
CRGFS A B C D
2.88 1.60 12 0.79
-100
73.16 40.58 304.8 20.07
3.25 1.75 12 0.82
-200
82.55 44.45 304.8 20.83 D
A
C
B

Top view of Current Sensing Relay Shown with Remote Current Remote Current Transformers CRGFS - Series
Transformer Option (-R)

PART NUMBER
CR7310 - - - - - - -

TRIP STATUS
EH - Energized on High, trips
SUPPLY VOLTAGE
AC
TRIP RANGE
.011 - .01 to 0.1 AAC
.11 - 0.1 to 1.0 AAC
TRIP POINT DIAL
CD - Calibrated Dial
I - INTERNAL TRANSFORMER
R1 - REMOTE TRANSFORMER
D
120 - 120 VAC FP - Fixed Trip Point w/ CRGFS-100
when sense current is above trip 110 - 1.0 to 10 AAC
240 - 240 VAC (Specify value of fixed (1.60” window diameter)
point and returns to non-trip 330 - 3.0 to 30 AAC

Relays, Switches, & Sensors


trippoint with order) R2 - REMOTE TRANSFORMER
status when sense current is DC 660 - 6.0 to 60 AAC
w/ CRGFS-200
24D - 24 VDC 101 - 10 to 100 AAC
D CURRENT TRIP

No adjustment
25

below the trip point.


30

(1.75” window diameter)


20

dial provided with


The trip ranges shown are for the fixed set
15

EL - Energized on Low, trips point option


3
10

one wire pass through the


5

All supply voltage tolerances


when sense current is below trip window opening. The trip range - CD - FP
are ± 10 % may be proportionally lowered
point and returns to non-trip with additional wire passes
-3.30 trip range shown

status when sense current is through the window.


above the trip point. OUTPUT OPTIONS
LH - Latch on High, trips when TRIP ON DELAY
sense current is above trip point A - .5 to 6 Sec. NC NO COM +
+
and remains tripped until B - 2 to 25 Sec.
supply power is removed. C - .1 to 1 Sec. -
LL - Latch on Low, trips when X - none
sense current is below trip point Time-on delay is the time from when the relay trips to
and remains tripped until supply when the output energizes. The ranges are ELR NPN TRC
guaranteed minimum, actual range may be slightly Electromechanical Optoisolated Optoisolated
power is removed. greater. Relay NPN Transistor Triac, Zero Crossing

Example Part Numbers:


CR7310-EH-120-.011-CD-ELR-I (Relay with CT on board)
CR7310-EL-240-.11-CD-NPN-R1 (Relay with external CRGFS-100)

The Professional
Energy Monitoring
Company 3500 Scarlet Oak Blvd. St. Louis MO USA 63122 V: 636-343-8518 F: 636-343-5119
M N TI
ISO 9001:2008 Quality Management System
Web: http://www.crmagnetics.com 67 E-mail: [email protected]

You might also like