S1A4559109
DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
• Only appropriately trained persons who are familiar with and understand the contents of this manual
and all other pertinent product documentation and who have received safety training to recognize and
avoid hazards involved are authorized to work on and with this drive system. Installation, adjustment,
repair, and maintenance must be performed by qualified personnel.
• The system integrator is responsible for compliance with all local and national electrical code
requirements as well as all other applicable regulations with respect to grounding of all equipment.
• Many components of the product, including the printed circuit boards, operate with mains voltage.
Do not touch. Use only electrically insulated tools.
• Do not touch unshielded components or terminals with voltage present.
• Motors can generate voltage when the shaft is rotated. Prior to performing any type of work on the
drive system, block the motor shaft to prevent rotation.
• AC voltage can couple voltage to unused conductors in the motor cable. Insulate both ends of
unused conductors of the motor cable.
• Do not short across the DC bus terminals or the DC bus capacitors or the braking resistor terminals.
• Before performing work on the drive system:
- Disconnect all power, including external control power that may be present.
- Place a "Do Not Turn On" label on all power switches.
- Lock all power switches in the open position.
- Wait 15 minutes to allow the DC bus capacitors to discharge. The DC bus LED is not an
indicator of the absence of DC bus voltage that can exceed 800 Vdc.
- Measure the voltage on the DC bus between the DC bus terminals (PA/+ and PC/-) using a
properly rated voltmeter to verify that the voltage is <42 Vdc.
- If the DC bus capacitors do not discharge properly, contact your local Schneider Electric
representative. Do not repair or operate the product.
• Install and close all covers before applying voltage.
Failure to follow these instructions will result in death or serious injury.
Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility
is assumed by Schneider Electric for any consequences arising out of the use of this product.
© 2019 Schneider Electric. All Rights Reserved.
S1A45591-09 1/8
03/2020
Altivar Machine Altivar Process Lexium MV Drive
ATV32 ATV320 ATV340 ATV600 (1) ATV900 LXM32 ATV6000
Option Module
Drive version ≥
(Module version ≥ )
V1.5IE11(2)
VW3A3720 Ethernet IP / Modbus TCP
(V1.8IE12)
V1.7IE16
VW3A3725 BACnet MS/TP
(V1.1IEXX)
≥V1.0IE03
VW3M3301 DeviceNet ≤V1.20IE05
(V1.0)
V1.24IE03
VW3M3308 PROFINET
(V1.0IE11)
Upcoming commercialization,
VW3A3530D ATV dPAC Module for the Altivar Firmware Version, contact
your Schneider Electric Customer Care
Center on www.se.com/CCC
2)
3)
! !
4)
XX
XX
XX
XX
5)
XXXXXXXX
XXXXXXXX
1) 2)
NVE22661
VW3A3600
CL
IC
Removing
Slot 1
Slot 2
Slot 3
2 3
IC
CL
Removing
1 2 3
1) STATUS ATV600
ASF
6 8
3A A3 362
D
VW 361 08
37 721
30
19
VW 07
3A 9
25
3A 8
27
ETH LNK
20
VWW3 3A
35
36
3A A3
36
VW 36
37
36
3A
3A
3A
VWW3
ETH NS
3A
W
VW
VW
V
VW
V
V
COM
STATUS
!
ATV340, ATV900
ASF
LNK1
VW 36 618 8
MS
3A A3 360
D
07
VW 609
19
30
3A 8
27
NS
01
VW 3 A
2
36
36
35
VWW3
36
36
3
3A
3A
3A
LNK2
3A
3A
V
VW
VW
VW
VW
COM
2)
!
3)
4)
B A
5)
2)
1)