TOWER CRANE FDN On Permanant Raft Check For Stability
TOWER CRANE FDN On Permanant Raft Check For Stability
TOWER CRANE FDN On Permanant Raft Check For Stability
CONTENTS Page no
P1 P2
P3 P4
Fh = 26 KN
Fv = 600 KN
M = 1350 KN-m
Z-dir
(-,-) (+,-)
P1 P2 X-dir
(-,+) (+,+)
P3 P4
p1 p2
Pt
5200 mm
p3 p4
3600
5200
Data: L B
Pile Cap Size 5200 5200
Column Size 1400 1400
Grade of Concrete (fck) = 35 N/mm2
Grade of Steel (Fy) = 500 N/mm2
Dia. Of Pile (D) = 1200 mm
Number of Piles = 4 Nos.
Pile Spacing (S) = 3600 mm
Length of Pile Cap, L = S+D+2*300 = 5200 m
Maximum vertical load exerted on each pile from 4 pile group = 33.75 Tons
Vertical load due to moment = 31.04 Tons
Max. B.M at the face of Column (M)= = 142.54 T-m
Factored Max. B.M at face of Column (Mu)= 1.5xM = 213.81 T-m
500
843.75
section for diagonal tension will be tested at a distance of 0.5d from face of column
shear force by linear interpolation = 23.73 Tons
Factored Shear force (Vu) = 1.5*(P) = 35.6 Tons
Permissible shear stress in concrete ( tc ) for 0.19% Steel = 0.33 N/mm2
Nominal shear stress ( tv ) = 0.04 <0.33
tc > tv Hence O.K
PILE DATA:
= 29580 N/mm2
E = 295804 kg/cm2
L1 / T = 0.00
Fixed end moment (Mf) = Qh*(L1 + Lf)/2 (From IS 2911 Part I/sec1)
Mf = 1.3 t-m
Actual moment on the pile (M) = 1.3 t-m Appendix B, fig 3A & 3B)
fck = 35 N/mm2
PAGE NO :
DESIGN CALCULATIONS OF TOWER CRANE PILE FOUNDATION DESIGN REV. NO. : R0
fy = 500 N/mm2
Pu = 50.6 t (Pu=1.5 * P)
d'/D = 0.125
1131 mm2
Minimum reinforcement required =
Pu = 5.6 t
Mu = 1.9 t-m
d'/D = 0.125
The moment due to lateral force is prevelant only upto depth of fixity.
PAGE NO :
DESIGN CALCULATIONS OF TOWER CRANE PILE FOUNDATION DESIGN REV. NO. : R0
Hence vertical reinforcement is curtailed beyond the depth of fixity of pile.
PAGE NO :
DESIGN CALCULATIONS OF TOWER CRANE PILE FOUNDATION DESIGN REV. NO. : R0
Depth of Fixity of Pile (Fixed head) = 4.1 m
The reinforcement required beyond point of curtailment is calculated for maximum compression capacity
Minimum Eccentricity = e = 20 mm
Fck = 35 N/mm2
Fy = 500 N/mm2
Pu = 506250 N
Mu = 10125000 N-mm
Fck = 35 N/mm2
Fy = 500 N/mm2
Pu = 56250 N
Mu = 1125000 N-mm
Mu/(Fckxp/4xD3) = 1125000/(35x3.14/4x600�) = 0