Manual de Operación
Manual de Operación
Manual de Operación
: ·.
·. '
......
·: -.. .:,;·m-:e ·lf·a :; ;'1<,m; ,rn:·.·'.·/: ·. ~a¡;m,.;, tt;·m:~· "';;,:.'·~:,,,_> .:..:_t~·,·: .-:~·:.. ~i,'<:"<~:::,.,,~
Weighing Scales
•
PRW series weighing scales operation manual
CONTENTS
1. INTRODUCTION ............................................................... 1
2. KEY DESCRIPTIONS ...................................................... 1
3. BASIC OPERATION ........ ·................................................ 2
3.1 Zeroing the display ...........................................................2
3.2 Taring .................................·........................................... 2
4. CHECK-WEIGHING ...........................................................3
4.1 About check-weighing ...................................................... 3
4.2 Set limits ........................................................................ 4
4.3 Set check weighing mode .................................................. 4
4.4 Note ...... ........................................................................ 4
5. ACCUMULATED TOTAL .................................................. 5
6. ANIMAL SCALE ................................................................. 6
7. CALIBRATION ................................................................. 6
8. BATTERY OPERATION .............................·......................... 7
9 . Fu N e T 1o N M E N u s.ETT 1N G ............................................. 8
· 2016 PRW series weighing scales operatio n manual
1. INTRODUCT/ON
The PRW series of weighing sea les provides an accurate, fast and
versatile series of general purpose indicator with unit conversion and
animal scale functions.
Ali units include automatic zero tracking , unit conversion, tare, and
an accumulation facility that allows the individual weights to be stored
and recalled as an accumulated total.
Wireless transmission and the distance is farther than 100 meters
2. KEY DESCRIPTIONS
Zero
Set the zero point far all subsequent weighing. The display shows
zero.
A secondary function ..-a, of "Enter" key when setting parameters or
other functions.
Tare
Tares the scale. Stores the current weight in memory as a tare value,
subtracts the tare value from the weight and shows the results. This is the
net weight. Entering a value using the keypad will store that value as the
tare value.
A secondary function . . , of incrementing the active digit when
setting a value far parameters or other functions.
GIN
Press the key , the scale can to select gross weight or net weight
after you tare a weight.
Secondary function ...... , In .the setting mode, this key used to move
active digits right.
M+
To print the results to a PC or printer using the optional RS-232
interface. lt also adds the value to the accumulation memory if the
-1-
PRW series weighing scales opera tior1 r~~L~al - - -- í-~t V YMt
'
UNIT or U
Press this key to select the weight unit.
secondary function (ESC ar ) , is to return to normal operation when
the scale is in a parameter setting mode or use to move active digits left.
when setting values for parameters
ON/ OFF
Turn on ar off the power.
3. BASIC OPERATION
3.1 Zeroing The Display
You can press the ...-~-ER_Q
____ key at any time to set the zero point from
which all other weighing and counting is measured, within 4o/o of power
up zero. This will usually only be necessary when the platform is empty.
When the zero point is obtained the display will show the indicator far
zero.
• The scale has an automatic rezeroing function to account fer minar
drifting or accumulation of material on the platform. However yo,u may
need to press the ~ERQJ key to rezero the scale if small amounts of
I
3.2 Taring
Zero the scale by pressing the IZERQ key if necessary. The zero
indicator will be on.
Place a container on the platform. a value for its weight wilf be
•
displayed.
-2-
~ 2016 PRW series weighing sca les operation manual
Press the [AREJ key to tare the scale. The weight that was displayed
is stored as the tare value and that value is subtracted from the display,
leaving zero on the display. The "TARE" indicator will be on. As product is
added only the weight of the product will be shown. The scale could be
tared a second time if another type of product was to be added to the first
one. Again only the weight that is added after taring will be displayed.
When the container is removed a negative value will be shown. lf the
scale was tared just befare removing the container this value is the gross
weight of the container plus all product that was removed. The zero
indicator will also be on because the platform is back to the same
condition it was when the lZEROIkey was last pressed.
4 Check-Weighing
4.1 About check-weighing
. Check-weighing is a procedure to cause an alarm to sound when the
weight on the scale meets _o r exceeds values stored in memory. The
memory holds values far a high limit and a low limit.
Check mode 2:
When check range, the display will show OK and the beeper will
sound when the weight is between the limits.
Check mode 3:
When check range, the display will show OK and the beeper will
sound when the weight is out of the limits.
-3-
PRW series weighing scales operation manual REV YM1 ¡
5 Accumulated Total
5.1 Note
The scale can be set to accumulate manually by pressing the ~
ke~. See t~e PARAMETERS Section for details of selecting th0 method
usmg function "FL/ P rl:::". The accumulation function is only available
when weighing.
Please note befare every accumulate operate, scale need return to
-4-
•
:
PRW series v1eig híng scales opera tír
2016 ~.; n í'iar ~~ '
-5-
PRW series weighing scales operation manual REV Y~
Press weight on platform, after stable, you will hear beep on twice,
you can add or remate weight now, scale will beep on again after stable,
at last, remove all weight on platform, the last weight value will store in
memory
6 Animal Scales
PRW can set as an animal scale when externa! resolution less than
1/3000, about how to set it, see the technical manual of PRW.
Let the animal on the platform, after sorne second, if reading data
change not a lot, you can hear beep sound and reading data will be
locked.
In reading data lock mode, if you add/remove big weight, display wif f
still update and lock new reading data.
7. CALIBRATION
In weighing mode, press IUNI] key and IM±J key together, "Fo H-L ".
Press ITAREl continuous until display will be shown "ProC". Press IZEROI,
display will be shown "P 1n". Enter the password. Press lGJNI, IUNllj and
IZEROI, Display will be shown "P I SPEd", Press [AREJ, display will be
shown "P2 CRL ". Enter the function by pressing IZEROI, display will be
shown "dE[", Press [ARS continuous until display will be shown "[RL ".
Enter the function by pressing IZEROI, display will be shown "L 1nERr",
Press [AREi to select for normal calibration "nonL 1n". '
Enter the function by pressing IZERQ, display will be shown
"UnL oRd", Make su re there are no loads on the platform and wait few
seconds for stable indicator on. Enter the function by pressing IZERóJ,
display will be shown"05 000": Currently adjustment, lf want to change
by using the keys IM±J, IG!NI, [AREi to select the required setting. · · - ·
Enter the selected setting by pr.essing IZEROI, display will be
shown "L oRd".
-6-
1 201 6 PRW series weig hing sca les operatio n manual
Load the calibration mass weight on the platform and wait few seconds
for display stability.
After the stable indicator on press !ZEROI, display will be
shown "PRSS".
After the calibration the display will start a self test. Remove the load from
platform during the test. Display will come to weighing mode
automatically.
lf display will be shown any error or incorrect value, repeat the procedure
•
aga1n.
8. BATIERY OPERATION
The weighing indicator can be operated from the ba~ery if desired.
The battery life is approximately 35 hours.
When the battery needs charging, the battery symbol will blank. The
scale will still operate far about several minutes after which it will
automatically switch off to protect the battery.
To charge the battery simply plug into the AC adapter. The scale
does not need to be turned on.
The battery should be· charged for 12 hours for full capacity.
In the LCD display has a battery indicator to indicate the status of
battery charging. When the scale is plugged into AC adapter, the
interna! battery will be charged. When turn on the indicator, if the
battery indicator is full then the battery has a full charge. lf it is half then
the pattery is nearly discharged and empty indicates the battery should
· be charged. When charge the battery, the indicator will be flicker.
As the battery is used it may fail to hold a full charge. lf the ~ battery
life become·s unacceptable then contact your distributor.
-7-
PRW series weighing scales operation manual REV YM1 1
-8-
PRW series weighing scales operation manual
1ne 2016