01

Sensors & Input Devices

STR200-STR202

Part NUMBER Wall Modules


Part Number Model Number The STR is a series of wall modules optimized for
004603000 STR200 public facilities such as office buildings, hotels,
004603010 STR200-W (White) hospitals, schools and shopping malls. Their
pleasant appearance and well-designed interface
004603200 STR202
make them suitable for any contemporary building.
They are both easy to operate and install.
SPECIFICATIONS
The STR200 and STR202 are equipped with a
Ambient Conditions
3-pole stereo-jack to allow connection to the M/STAT
Storage temperature. . . . . . . . . . . –20 °C to +70 °C
unit. The STR200 replaces the TTS100WJ while the
(–4 °F to +158 °F)
STR202 replaces the S/STAT. The STR200-202 can
Operation temperature. . . . . . . . . . . 0 °C to +50 °C be used with the 7728, MRs, and Xenta 102-AX
(+32 °F to +122 °F) controllers.
Humidity. . . . . . . . . . . . . . . . . . . . . . . . . . max. 90%
non-condensing relative humidity The STR200 is equipped with a temperature sensor,
while the STR202 also features a bypass button and
Mechanical
a setpoint offset wheel.
Enclosure material . . . . . . . . . . . . . . . . . . . ABS/PC
Enclosure rating . . . . . . . . . . . . . . . . IP 20/NEMA 1
Dimensions. . . . . . . . . . . . . . . . . . . . . . . see Fig. 1
Weight. . . . . . . . . . . . . . . . . . . . . . . . 85 g (0.19 lb.)
Agency Compliances
Emission
CE. . . . . . . . . . . . . . . . . . . . . . . . . . EN 61000-6-3
C-tick. . . . . . . . . . . . . . . . . . . . . . . . . C-Tick N1831
FCC. . . . . . . . . . . FCC Part 15, Subpart B, Class B
Immunity
CE. . . . . . . . . . . . . . . . . . . . . . . . . . EN 61000-6-1
Safety
CE. . . . . . . . . . . . . . . . . . . . . . . . . . . . EN 61010-1
UL . . . . . . . . . . . . . . . . . . . . . C-UL, UL 916 Listed
Flammability
UL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UL 94 V-0
Sensor Data
Type. . . . . . . . . . . . . . . . . . . . . . . 10 kΩ thermistor
Accuracy . . . . . . . . . . . . . . . . . . . . . . . at 15–30 °C
(59–86 °F), ±0.30 °C (0.54 °F)
02
Sensors & Input Devices STR200 - STR202

FUNCTIONS Model Temp. Setpoint Bypass


Fig. 2 shows an STR202. The STR200 may have Sensor Offset Button
Wheel
less functionality.
STR200 X – –
Bypass Button STR202 X X X
A bypass button is provided on the model
STR202 to change from standby (economy) or
unoccupied mode to comfort mode. DIMENSIONS mm (in)

Setpoint Offset Wheel 84 (3.3)


A setpoint offset wheel is provided on model 82 (3.2)
STR202 for adjusting the temperature setpoint

24 (0.9)
offset.

The adjustment range is configured in the


connected controller.

The adjustment range may be set to the


following limits:

• ±1 ºC (±1.8 ºF)
116 (4.6)
58 (2.28)

• ±2 ºC (±3.6 ºF)
• ±3 ºC (±5.4 ºF)
• ±4 ºC (±7.2 ºF)
• ±5 ºC (±9.0 ºF)

Increase/decrease limits are separately


­adjustable.

Wiring
Figure 1
The STR200 uses a three-wire installation. The
wiring is easily accessible thanks to the plug-in
concept.
STR202
The STR202 requires 1 or 2 more conductors
depending on which controller is used.

Cables
Twisted pair, unshielded. Min. cross-sectional
area: 0.7 mm² (AWG-19). Max. distance: 30 m
(100 ft).

Mounting
The units can be mounted directly onto the wall
or fitted onto a wide variety of back-boxes. The
plug-in concept makes wiring quick and easy.

Maintenance
No maintenance is required for the wall module.
© 2012 Schneider Electric. All rights reserved.

If necessary, the wall module may be cleaned 1. Bypass button.


with a soft cloth. 2. Setpoint offset wheel.