Practice Test 4 (https://rank.sanfoundry.
com/analytical-instrumentation-practice-test-4/)
Practice Test 5 (https://rank.sanfoundry.com/analytical-instrumentation-practice-test-5/)
Practice Test 6 (https://rank.sanfoundry.com/analytical-instrumentation-practice-test-6/)
Practice Test 7 (https://rank.sanfoundry.com/analytical-instrumentation-practice-test-7/)
Practice Test 8 (https://rank.sanfoundry.com/analytical-instrumentation-practice-test-8/)
Practice Test 9 (https://rank.sanfoundry.com/analytical-instrumentation-practice-test-9/)
Practice Test 10 (https://rank.sanfoundry.com/analytical-instrumentation-practice-test-10/)
Mock Test 1 (https://rank.sanfoundry.com/analytical-instrumentation-mock-test-1/)
Mock Test 2 (https://rank.sanfoundry.com/analytical-instrumentation-mock-test-2/)
Mock Test 3 (https://rank.sanfoundry.com/analytical-instrumentation-mock-test-3/)
Mock Test 4 (https://rank.sanfoundry.com/analytical-instrumentation-mock-test-4/)
Mock Test 5 (https://rank.sanfoundry.com/analytical-instrumentation-mock-test-5/)
Mock Test 6 (https://rank.sanfoundry.com/analytical-instrumentation-mock-test-6/)
Mock Test 7 (https://rank.sanfoundry.com/analytical-instrumentation-mock-test-7/)
Mock Test 8 (https://rank.sanfoundry.com/analytical-instrumentation-mock-test-8/)
Mock Test 9 (https://rank.sanfoundry.com/analytical-instrumentation-mock-test-9/)
Mock Test 10 (https://rank.sanfoundry.com/analytical-instrumentation-mock-test-10/)
« Prev Page (https://www.sanfoundry.com/analytical-instrumentation-problems/)
Next Page (https://www.sanfoundry.com/analytical-instrumentation-paramagnetic-oxygen-analyser/) »
Analytical Instrumentation Questions and Answers – Amino-Acid Analysers
This set of Analytical Instrumentation Multiple Choice Questions & Answers (MCQs) focuses on “Amino-Acid Analysers”.
1. What is the drawback that occurs in using ion exchange chromatography on sulphonated polystyrene resin and colourimetry for amino-acid
analysis?
a) Less accuracy
b) Low resolution
c) Inconvenient to handle many individual samples
d) Slow in operation
View Answer
Answer: c
Explanation: When ion exchange chromatography is used for amino-acid analysis, high accuracy is obtained. It is inconvenient to handle many
individual samples and cleaning of glassware is laborious.
advertisement
2. Which one of the following methods is the most suitable for amino-acid analysis?
a) Gas chromatography
b) Ion exchange chromatography
c) Paper electrophoresis
d) Resin column chromatography
View Answer
Answer: d
Explanation: Resin column chromatography is the most suitable for amino-acid analysis. Here, ion exchange resin chromatography is followed.
3. Which of the following colour reagents are used in Resin column chromatography?
a) Marquis reagent
b) Benedict reagent
c) Ninhydrin
d) Nessler’s reagent
View Answer
Answer: d
Explanation: Ninhydrin is the colour reagent used in resin column chromatography. The colour reaction occurs during a known period and
controlled temperature.
4. Which of the following amino-acids is measured at a wavelength of 440nm using photometric systems?
a) Proline
b) Alanine
c) Glutamine
d) Valine
View Answer
Answer: a
Explanation: Proline and hydroxyproline are measured at 440nm. All the other amino acids are measured at 570nm.
5. In Automatic amino-acid analyzer, the sample containing ___________ of each amino compound is introduced at the top of the ion exchange
column.
a) 1 to 10 µmoles
b) 1 to 10 moles
c) 0.05 to 2 moles
d) 0.05 to 2 µmoles
View Answer
Answer: d
Explanation: In Automatic amino-acid analyzer, the sample having 0.05 to 2 µmoles of each amino compound is introduced at the top of the ion
exchange column. Buffer is then supplied to the column.
advertisement
6. Which of the following cannot be analysed using resin column chromatography?
a) Peptides
b) Amines
c) Amino compounds
d) Components which are ninhydrin negative
View Answer
Answer: d
Explanation: Components which are ninhydrin negative cannot be analysed using resin column chromatography. Only the components that are
nindydrin positive are analysed using this method.
7. Trapped air in pumps of Automatic amino-acid analyzer is eliminated using which of the following ways?
a) Suction pump
b) De-aerator
c) Overcome naturally by pump pressure
d) Using pulse damper
View Answer
Answer: b
Explanation: De-aerator is used to eliminate trapper air in pumps of an automatic amino-acid analyzer. Here, bubble-trap type de-aerator is used.
8. Amino-acids are distinguishable from each other only by one or two atoms in their structure.
a) True
b) False
View Answer
Answer: a
Explanation: Amino-acids are distinguishable from each other only by one or two atoms in their structure. They are components of all proteins and
are essential for growth of organisms.
9. What is the drawback that occurs in using gas chromatography for amino-acid analysis?
a) Costly
b) Cannot be used for proteins or polypeptides
c) Slow process
d) Complex in operation
View Answer
Answer: b
Explanation: Gas chromatography cannot be used for proteins or polypeptides. Further, accuracy is lost while converting amino-acids into the
gaseous phase.
10. Resin column chromatography does not involve breaking of bonds in amino-acids.
a) True
b) False
View Answer
Answer: b
Explanation: Resin column chromatography involves breaking of bonds in amino-acids. This causes a delay as acid is eluted through the column by
a buffer.
advertisement
Sanfoundry Global Education & Learning Series – Analytical Instrumentation.
To practice all areas of Analytical Instrumentation, here is complete set of 1000+ Multiple Choice Questions and Answers
(https://www.sanfoundry.com/1000-analytical-instrumentation-questions-answers/).
« Prev Page - Analytical Instrumentation Questions and Answers – Detection System of Liquid Chromatography
(https://www.sanfoundry.com/analytical-instrumentation-problems/)
» Next Page - Analytical Instrumentation Questions and Answers – Paramagnetic Oxygen Analyser (https://www.sanfoundry.com/analytical-
instrumentation-paramagnetic-oxygen-analyser/)
advertisement
Deep Dive @ Sanfoundry:
1. Distillation Design Questions and Answers (https://www.sanfoundry.com/1000-distillation-design-questions-answers/)
2. Life Sciences Questions and Answers (https://www.sanfoundry.com/1000-life-sciences-questions-answers/)
3. Unit Processes Questions and Answers (https://www.sanfoundry.com/1000-unit-processes-questions-answers/)
4. Engineering Chemistry Questions and Answers (https://www.sanfoundry.com/1000-engineering-chemistry-questions-answers/)
5. Instrumentation Transducers Questions and Answers (https://www.sanfoundry.com/1000-instrumentation-transducers-questions-
answers/)
6. Biomedical Instrumentation Questions and Answers (https://www.sanfoundry.com/1000-biomedical-instrumentation-questions-
answers/)
7. Biochemistry Questions and Answers (https://www.sanfoundry.com/1000-biochemistry-questions-answers/)
8. Instrumentation Engineering Questions and Answers (https://www.sanfoundry.com/instrumentation-engineering-questions-
answers/)
9. Organic Chemistry Questions and Answers (https://www.sanfoundry.com/1000-organic-chemistry-questions-answers/)