EN5231 3 0 01 20 - P4WEH - 10to32
EN5231 3 0 01 20 - P4WEH - 10to32
EN5231 3 0 01 20 - P4WEH - 10to32
CONTENT
Designation 1
Features 1
Model code 2
Spool types / Symbols 2
Function 3
Section view 3
EN 5.231.3. 0/01.20
Accessories 3
Technical Data 4
Performance 4
Dimensions 6
1
MODEL CODE
P4WEH E 10 E80 D01-24PG/V/D
Type
Proportional 4 directional valve, electrical / hydraulic
Control type
E = external pilot supply and drain
EI = external pilot supply, internal pilot drain
IE = internal pilot supply, external pilot drain
I = internal pilot supply and drain
Symbols
See page 2
Series
D01 = standard
D02 = ISO 4401-05-05-0-05 (NG10 only)
Coil Type
PG = DIN connector to DIN 43563
Sealing material
V = FKM (standard)
N = NBR
E J
EA JA
EN 5.231.3. 0/01.20
EB JB
2
FUNCTION SECTION VIEW
The P4WEH is a hydraulic pilot
operated, proportional 4 directional 3 1
valve. The volume flow is controlled
continuously (proportionally) to the
electrical input signal at the solenoid 2
coil.
These valves essentially consist of 3
the pilot stage (pressure regulating
valve) and the main stage
(directional valve). The pilot stage
consists of the valve housing (1), a
control piston with 2 pressure
measuring pins (2) and two
proportional solenoids (3).
The main stage consists of the
6
housing (4), a main piston (5) and a
4
centring spring (6) acting in both
directions.
The pressure supply of the valve
results from the interface according
to ISO 4401. The external pilot 5
supply and drain result from port X
and Y to the pilot valve. The
regulated control pressure is
proportional to the stroke of the main
stage. If one of the two solenoids is
energized, the pilot releases the
connection to control port A or B and
regulates the control pressure
according to the set solenoid current.
*For further information see brochure "Control modules for hydraulic drives -EHCD"
catalogue-24000.2/10/14 or contact customer support [email protected].
3
TECHNICAL DATA ¹
General specifications
Nominal size
10 16 25 32
MTTFd: According to EN ISO 13849-1:2015 chart C1 & C2
Ambient temperature: [°C] -20 to +60
Installation position: No orientation restictions
Weight: [kg] 7,5 9,7 16,0 53,0
Material: Valve casing: Cast iron
Name plate: Aluminium
Surface coating: Valve casing: Phosphate
Hydraulic specifications
Nominal size
10 16 25 32
Operating pressure: [bar] Port P: pmax = 350
Port T, internal leak port: pmax = 10
Port T, external leak port: pmax = 250
Control pressure: [bar] pmin = 30
pmax = 210
Max. nominal flow: [l/min] 180 450 800 1600
Nominal flow ranges: [l/min] 80 100 200 350
(at Δp = 10 bar, P → T) 80/40 150 300 500
150/75 300/150 500/250
Operating fluid: Hydraulic oil to DIN 51524 part 1, 2 and 3
Media operating temperature range: [°C] -20 to +80
Viscosity range: [mm²/s] 10 – 400
Permitted contamination level class 18/16/13 to ISO 4406
of operating fluid:
Sealing material: NBR, FKM (standard)
Control flow: [l/min] 3 5 9 13
(Control 0 → 100 %)
Control volume: [cm³] 1,7 3,2 9,1 21,6
(Control 0 → 100 %)
Electrical specifications
Nominal size
10 16 25 32
Switching time (0 → 100%): [ms] 50 80 100 200
Switching time (100% → 0): [ms] 40 50 70 120
Type of voltage: DC
Rated voltage: [V] 12, 24
Hysteresis: [%] < 4 of Qmax
Repeatability: [%] < ±2 of Qmax
Protection class to DIN EN 60529: with electrical connection “G“ IP65 ²
Hint
If the system pressure exceeds the max. allowable control pressure, it is necessary to use the version with external control and
control pressure within the specifications. Otherwise, the valve with internal pilot control and pressure reducing valve as 30 bar fixed
sandwich plate can be ordered.
¹ see „Conditions and Instructions for Valves“ in brochure 53.000
PERFORMANCE
Q-I-performance NG10
The performance represent typical curves for the (measured at 36 cSt, 50°C), symbols E; EA; EB; J;
various available valve pistons, at a constant Δp, JA; JB, nominal flow 80 l/min
depending on the current supplied by the solenoid
coil.
(Note: The maximum current for the solenoid version
D24 is 800 mA).
The total valve pressure drop (Δp) was measured
between port P and T of the valve.
EN 5.231.3. 0/01.20
4
PERFORMANCE
Q-I-performance NG16
(measured at 36 cSt, 50°C), symbols E; EA; EB; J;
JA; JB, nominal flow 100 l/min
Nominal flow 300 l/min
Q-I-performance NG32
(measured at 36 cSt, 50°C), symbols E; EA; EB; J; JA;
Nominal flow 150 l/min JB, nominal flow 350 l/min
Q-I-performance NG25
(measured at 36 cSt, 50°C), symbols E; EA; EB; J;
JA; JB, nominal flow 200 l/min, Nominal flow 500 l/min
EN 5.231.3. 0/01.20
5
DIMENSIONS NG10
INTERFACE INTERFACE
CETOP 4.2-4 P05-350 (D01) ISO 4401-05-05-0-05 (D02)
(CETOP 4.2-4 R05-350)
standard manual
override
Hint
When using the pressure
reducing as sandwich plate, the
installation height changes by 40
mm to 180.5 mm.
EN 5.231.3. 0/01.20
6
DIMENSIONS NG16
INTERFACE
ISO 4401-07-07-0-05 (D01)
(CETOP 4.2-4-07-350)
standard manual
override
Hint
When using the pressure reducing as
sandwich plate, the installation height
changes by 40 mm to 190.5 mm.
7
DIMENSIONS NG25
INTERFACE
ISO 4401-08-08-0-05 (D01)
(CETOP 4.2-4-08-350)
standard manual
override
Hint
When using the pressure reducing as
sandwich plate, the installation height
changes by 40 mm to 216.5 mm.
EN 5.231.3. 0/01.20
8
DIMENSIONS NG32
INTERFACE
ISO 4401-10-09-0-05 (D01)
(CETOP 4.2-4-10-350)
standard manual
override
Hint
When using the pressure reducing as
sandwich plate, the installation height
changes by 40 mm to 272.2 mm.
EN 5.231.3. 0/01.20
9
Plug
X Y
• Version „E“ –
Pilot oil supply is external from a separate fluid power supply via port X.
The pilot oil drain is also external via port Y.
• Version „EI“ –
Pilot oil supply is external from a separate fluid power supply via port X.
The pilot oil drain is internal via port T.
• Version „IE“ –
Pilot oil supply is internal via port P.
The pilot oil drain is external via port Y.
• Version „I“ –
Pilot oil supply is internal via port P.
The pilot oil drain is internal via port T.
Note
The information in this brochure relates
to the operating conditions and
applications described. For applications
not described, please contact the
relevant technical department.
All technical details are subject to
change without notice.
Justus-von-Liebig-Str.
D-66280 Sulzbach/Saar
Tel: 0 68 97 /509-01
Fax: 0 68 97 /509-598
E-Mail: [email protected]
10