Apv Delta Sv1: Instruction Manual

Download as pdf or txt
Download as pdf or txt
You are on page 1of 44

INSTRUCTION MANUAL

APV DELTA SV1


B U T T E R F LY VA LV E

FORM NO.: H170726 REVISION: UK-8 R E A D A N D U N D E R S TA N D T H I S M A N U A L P R I O R TO O P E R AT I N G O R S E RV I C I N G T H I S P R O D U C T.

Scan for SV1/SVS1F Valve


Maintenance Video
UK

Declaration of Conformity
for Valves and Valve Manifolds
SPX FLOW Technology Rosista GmbH, Gottlieb-Daimler-Str. 13, D-59439 Holzwickede
herewith declares that the

APV double seal and double seat valves of the series


SD4, SDT4, SDU4, SDMS4, SDMSU4, SDTMS4, SWcip4, DSV,
DA3, DA3SLD, DE3, DEU3, DET3, DKR2, DKRT2, DKRH2
in the nominal diameters DN 25 - 150, ISO 1“ – 6“ and 1 Sh5 - 6 Sh5

APV butterfly valves of the series SV1 and SVS1F, SVL and SVSL
in the nominal diameters DN 25 - 100, DN 125 - 250 and ISO 1“ – 4“

APV ball valves of the series KHI, KHV


in the nominal diameters DN 15 - 100

APV single seat, diaphragm and spring loaded valves of the series
S2, SW4, SWhp4, SW4DPF, SWmini4, SWT4, SWS4, MF4, MS4, MSP4, AP/T1, CPV,
RG4, RG4DPF, RGMS4, RGE4, RGE4DPF, RGEMS4, PR2, PRD2, SI2, UF/R3, VRA/H
in the nominal diameters DN 10 - 150, ISO 1/2“ – 4“ and 1 Sh5 - 6 Sh5

and the valve manifolds installed thereof

meet the requirements of the Directives 2006/42/EC (superseding 89/392/EEC


and 98/37/EC) and ProdSG (superseding GPSG - 9.GPSGV).

For official inspections, SPX FLOW Technology Rosista GmbH presents


a technical documentation according to Appendix VII of the Machinery Directive,
this documentation consisting of documents of the development and construction,
description of measures taken to meet the conformity and to correspond with
the basic requirements on safety and health, incl. an analysis of the risks,
as well as an operating manual with safety instructions.

The conformity of the valves and valve manifolds is guaranteed.

Authorised person for the documentation:


SPX FLOW Technology Rosista GmbH, Frank Baumbach,
Gottlieb-Daimler-Str. 13, D-59439 Holzwickede

January 2017

Manager Research and Development


APV UK
APV_SV1_UK-8_012017.qxp

Table of Contents Page

1. General Terms 2
2. Safety Instructions 2-3
3. Intended Use 3
4. Mode of Operation 4
4.1. General Terms
5. Auxiliary Equipment 5-7
5.1. Valve position indication - actuated valve
5.2. Valve position indication - manually operated valve
5.3. Handle with adjusting device
5.4. Control Unit
5.5. Adapter for control unit
5.5.1. Adapter for control unit
5.6. Turning actuator for control unit
6. Cleaning 8
7. Installation 8-9
7.1. Connections
7.2. Welding Instructions
8. Dimensions / Weights 10 - 11
9. Technical Data 12 - 13
9.1. General Data
9.2. Compressed air quality
9.3. Kvs - values
9.4. Opening / Closing times
9.5. Torques
9.6. Control air consumption
10. Materials 14
11. Maintenance 15
12. Service Instructions 16 - 18
12.1. Disassembly from the line system
12.2. Disassembly of actuating device
12.3. Dismantling of inner parts
12.4. Replacement of seals
12.5. Installation of seals and bearing bushes
12.6. Installation of actuating device
12.7. Installation of proximity switches
13. Spare Parts Lists 19
(see attachment)

SV1 - FZ CU DN 25 - 100, 1”-4” - RN 01.037 - 14

SV1 - H DN 25 - 100, 1”-4” - RN 01.037.5 - 9

Handle SV-HL valve position indication - RN 01.037.0


DN25 - 100, 1” - 4”
Turning actuator K-80, K-125, K-180 F/L - RN 01.073
Turning actuator spring/air for feedback unit - RN 01.076

Butterfly Valve 1
DELTA SV1
Instruction Manual: UK - rev. 8
APV UK
APV_SV1_UK-8_012017.qxp

1. General Terms

This instruction manual has to be read carefully and observed by


the responsible operating and service personnel.
We do not accept any liability for damage or malfunctions resulting
from the non-compliance with this instruction manual.
Descriptions and data given herein are subject to technical
changes.

2. Safety Instructions
The valve must only be assembled, disassembled and
reassembled by persons who have been trained in APV valves
or by SPX FLOW service team members. If necessary, contact
your local SPX FLOW representative.

DANGER!

- The technical safety symbol draws your attention to important


! directions for operating safety. You will find it wherever the
activities described are bearing health hazards or risks for
persons or material assets.

! - Do not reach into the open valve or into the yoke!


Risk of bruising at movable parts of the valve.

- In dismantled state there is the risk of injury by sudden


! valve operation.

- Regular maintenance including replacement of seals and bearing


bushes must be scheduled for the valve in order to prevent
leakages and discharge of liquids.

- Before any maintenance of the valve, the line system must be


! depressurized and discharged if possible.

- Electric and pneumatic connections must be separated.


!
- Observe the following Service Instructions to ensure
safe maintenance of the valve.

Butterfly Valve 2
DELTA SV1
IInstruction Manual: UK - rev. 8
APV UK
APV_SV1_UK-8_012017.qxp

2. Safety Instructions

- DANGER!

! Welded actuators are preloaded by spring force.

Opening of the actuators is strictly forbidden.


Danger to life!

Actuators which are no longer used and / or defective


must be disposed in professional manner.

Defective actuators must be returned


to your SPX FLOW representative
for their professional disposal and free of charge for you.

Please address to your local SPX FLOW representative.

3. Intended Use

The intended use as field of application of the butterfly valve is


the shut-off of pipeline sections.

Arbitrary, structural changes at the valve may affect safety


as well as the intended functionality of the valve and
are not permissible.

Authorizations and External Approvals:


ATEX (Directive 2014/34/EU)

3 Butterfly Valve
DELTA SV1
Instruction Manual: UK - rev. 8
APV UK
APV_SV1_UK-8_012017.qxp

4. Mode of Operation

4.1. General Terms


Use of high-quality stainless steel and seal materials to the
specified requirements, the butterfly valve range DELTA SV1 is
applicable in the food and beverage industries as well as in the
chemical and pharmaceuticl industries.

Valves of the series DELTA SV1 can either be operated manually


or remote controlled via a pneumatic actuator. Manual operation
and pneumatic actuator including add-on pieces are inter-
changeable.

In the standard design “NC”, the pneumatic turning actuator opens


the valve with compressed air.
Reset by spring force into the limit position closed.

Extension of operating time of actuated valves by pneumatic air


throttle or adjusting screw in the control unit to optimize the
flow behaviour and to reduce the risk of pressure hammers in
installations if necessary.

The butterfly valve can also be used in vacuum systems.

The valve opens and closes by turning the disc by 90°.

Smooth valve passage without diversion of line flow.

The opening diameter complies with the size of the inner line
diameter.

Butterfly Valve 4
DELTA SV1
IInstruction Manual: UK - rev. 8
APV UK
APV_SV1_UK-8_012017.qxp

5. Auxiliary Equipment

5.1. Valve position indication - valve with pneumatic actuator


Proximity switches to signal the limit position of the valve disc
can be installed in the yoke area if required.

We recommend to use our APV standard proximity switches.


Type: three-wire proximity switch (ref.-No. 08-60-011/93, H16223)
Operating distance: 4mm / diameter: 11mm / length: 30 mm.

Feedback complete with support and proximity switch


(ref.-No. 15-33-023/93) for a limit position.

Using a valve position indicator other than APV, we cannot accept


any liability for faulty function.

5.2. Valve position indication - valve with manual operation


Specific manual actuations with feedback feature are available:
a) Feedback of the disc position closed
(simple variant).
b) Feedback of both disc positions
open and closed is possible.

5.3. Manual operation with adjusting device


As a special design, a handle is available which provides for the
fixation of intermediate positions beside the two limit positions.

5 Butterfly Valve
DELTA SV1
Instruction Manual: UK - rev. 8
APV UK
APV_SV1_UK-8_012017.qxp

5. Auxiliary Equipment

5.4. Control unit (CU, fig. 5.4.)


Fig. 5.4.
Units with feedback switch and magnet valve for the pneumatic
control of the valve for assembly on the actuator are also available
CU4
in fieldbus technology.
control unit
The assembly of a control unit on a pneumatic actuator
is possible.

The following different designs are available:

CU3 CU41-T-Direct Connect


control unit Direct Connect
08 - 45 - 101/93; H320461
AS-i extended CU41-T-AS-i extended
62 slaves 08 - 45 - 111/93; H320468
CU31 Device Net
Device Net
16 - 31 - 240/93; H209422
CU31 Profibus
Profibus
08 - 45 - 001/93; H315495

5.5. Adapter for control unit (fig 5.5.)


CU31 Profibus, CU31 Device Net
The following adapters are required to install the control unit
on the SV1 valve.

Spare parts for CU2 adapter


Fig. 5.5.
reference No.
1 Item Pcs. Designation
ID - No.
000 08-48-416/93
- - CU2 adapter K080 SVS1F, DKR
H209431
2
000 08-60-779/93
1 1 CU operating cam cpl. SVS/DKR
H208853

4 000 08-60-760/15
2 3 cyl. screw ISO1207-M5x18-A2-7
H208835
3 5 000 08-60-333/93
3 1 adapter set
H310442
6 000 58-06-387/83
-4 1 o-ring 88,62-1,78 NBR
H208639
000 58-06-044/83
7* -5 2 o-ring 5,28-1,78 NBR
H208640
000 08-60-728/93
-6 1 CU adapter for SVS,DKR
H208803
o-ring 90-2 NBR 000 58-06-426/83
8 7* 1
9 * scope of supply actuator H143352
000 58-06-049/83
8 1 o-ring 13,0-2,0 NBR 70
H208642
000 08-60-740/93
9 2 blind plug G1/8"
H208815

Butterfly Valve 6
DELTA SV1
IInstruction Manual: UK - rev. 8
APV UK
APV_SV1_UK-8_012017.qxp

5. Auxiliary Equipment

5.5.1. Adapter for control unit (fig. 5.5.1.)


Fig. 5.5.1. CU41-T-Direct Connect, CU41-T-AS-i extended
The following adapters are required to install the control unit
on the SV1 valve:
6

Spare parts for CU4 T-adapter


7 reference No.
Item Pcs. Designation
ID - No.
4 000 08-48-601/93
2 - - CU4 T-adapter cpl.
5 H 320475

000 08-46-571/93
1 1 CU4 T-adapter
H319875
1
000 65-05-054/13
2 3 cyl. screw ISO1207-M5x16-A2-7
H79000
8 3 o-ring 11,11-1,78 NBR 000 58-06-034/83
3 1
70shore A H321897
000 58-06-059/83
4 1 o-ring 6-2 NBR
H320505
9 000 58-06-493/83
5 1 o-ring 101,27-2,62
H148389
CU4-operating cam 000 08-60-900/93
6 1
complete H320479
000 08-60-905/93
7 1 CU4 SVS, DKR operating rod
H320480
000 08-46-569/93
8 2 CU4 clamp halves complete
H319873
cyl. screw ISO 4762 M4x40 000 65-05-040/13
9 2
inner hexagon H320360

5.6. Turning actuator for control unit


- For the assembly of a control unit on the butterfly valve
a special turning actuator is required.
The standard turning actuator must be replaced.

Turning actuator for control unit

DN 25 - 100 / K080 F/L ref.-No.: 000 - 15 - 37 - 070/17


Inch 1” - 4” / K080 F/L H123937

7 Butterfly Valve
DELTA SV1
Instruction Manual: UK - rev. 8
APV UK
APV_SV1_UK-8_012017.qxp

6. Cleaning

6.1. Cleaning recommendation

The valve passage is cleaned by the cleaning liquids during


cleaning of the connected pipelines.

Depending on the degree and constituents of soiling, the cleaning


liquids, times and processes must be scheduled for the individual
application.

The compatibility of the individually selected cleaning processes


and liquids with the respectively used seals must be verified.

7. Installation / Connections
In normal installation position, the actuator is positioned vertically
to the top. Depending on the respective application, optional
installation positions can, however, also be realized.

SV1 valves with weld ends are welded direct into the product
line.

Separate dismantling by a flange connection, etc. in the continuing


pipeline must be provided.

Attention: Observe welding instructions 7.2.

7.1. Connections:
Beside the housings with weld ends the following connections
are alternatively available:
- threaded and cone port to DIN 11851,
- threaded port RJT, ISS/IDF, SMS.
- clamp connection to 32676 (DN 25 - 100)
- clamp connection to ISO 2852 (Inch 1” - 4”)

Butterfly Valve 8
DELTA SV1
IInstruction Manual: UK - rev. 8
APV UK
APV_SV1_UK-8_012017.qxp

7. Installation / Connections

7.2. Welding Instructions


- Welding may only be carried out by certified welders (DIN EN ISO
9606-1). (seam quality DIN EN ISO 5817)

- The welding of the housing halves must be effected in such a way


that deformation strain cannot be transfered to the housing halves.

- TIG orbital welding is the most appropriate method.

- Before welding, all heat sensitive parts (e.g. seal, bearing, disc) of
the valve must be removed.

- After welding of the housing halves and after work at the pipelines,
the corresponding parts of the installation or pipelines must be
cleaned from welding residues and soiling.
If these cleaning instructions are not observed, welding residues
and dirt particles can settle in the valve and cause damage or be
carried over to other parts of the installation.

- Any damage resulting from the non-observance of these welding


instructions is not subject to our guarantee.

9 Butterfly Valve
DELTA SV1
Instruction Manual: UK - rev. 8
APV UK
APV_SV1_UK-8_012017.qxp

8. Dimensions / Weights

SV1 with
CU41 control unit

SV1 with
turning actuator

ØC
B1

ØC

ØD
ØE
ØD

A A

Weights in kg
Dimensions in mm
butterfly valve butterfly valve with
with turning actuator
DN A B B1 ØC ØD ØE
turning actuator and control unit
25 52 271,5 451,5 85 26 29 4,0 5,0
40 52 280 460 85 38 41 4,2 5,2
50 52 285 465 85 50 53 4,5 5,5
65 52,4 293,5 473,5 85 66 70 4,8 5,8
80 52,4 301 481 85 81 85 5,5 6,5
100 52,4 311 491 85 100 104 6,1 7,1
Inch
1” 52 271,5 451,5 85 22,6 25 4,0 5,0
1,5” 52 280 460 85 34,8 38 4,2 5,2
2” 52 285 465 85 47,8 51 4,5 5,5
2,5” 52,4 293,5 473,5 85 60,3 63,5 4,8 5,8
3” 52,4 297 477 85 72,9 76,1 5,5 6,5
4” 52,4 311 491 85 97,6 101,6 6,1 7,1

Butterfly Valve 10
DELTA SV1
IInstruction Manual: UK - rev. 8
APV UK
APV_SV1_UK-8_012017.qxp

8. Dimensions / Weights

SV1 with
manual actuation

ØD
ØE

Dimensions in mm
A

DN A B C ØD ØE Weights in kg
25 52 88 165 26 29 1,5
40 52 96,5 165 38 41 1,6
50 52 101,5 165 50 53 1,8
65 52,4 110 165 66 70 2,0
80 52,4 117,5 165 81 85 2,2
100 52,4 127,5 165 100 104 2,6
Inch
1” 52 88 165 22,6 25 1,5
1,5” 52 96,5 165 34,8 38 1,6
2” 52 101,5 165 47,8 51 1,8
2,5” 52,4 110 165 60,3 63,3 2,0
3” 52,4 113,5 165 72,9 76,1 2,2
4” 52,4 127,5 165 97,6 101,6 2,6

11 Butterfly Valve
DELTA SV1
Instruction Manual: UK - rev. 8
APV UK
APV_SV1_UK-8_012017.qxp

9. Technical Data

9.1. General data


- max. line pressure : 10 bar
elbow union - G1/8"
slewable
- max. operating temperature : 135o C EPDM, HNBR
tightening torque 2 Nm
* VMQ, * FPM

- short-term load : 140o C EPDM, HNBR


* VMQ, * FPM
* (no steam)

- vacuum tightness : 2 mbar

- opening angle of butterfly valve : 90o


min. air pressure for actuator : 6 bar
max. air pressure for actuator : 10 bar

turning actuator - air connection (for hose) : 6x1


K080 F/L elbow union - G1/8"
slewable : tightening torque 2 Nm

9.2. Compressed air quality: Quality class acc. to DIN/ISO 8573-1

content of solid particles: Quality Class 3


max. size of solid particles per m³
10000 of 0,5µm <d<1,0 µm
500 of 1,0µm <d<5,0 µm

content of water: Quality Class 4


max. dew point temperature + 3°C
For installations at lower temperatures
or at higher altitudes, additional
measures must be considered
to reduce the pressure dew point
accordingly.

content of oil: Quality Class 1


max. 0,01 mg/m³
The oil applied must be compatible with Polyurethane
elastomer materials.

9.3. kvs - values in m³/h


DN Inch
25 1” 40
40 1,5” 89
50 2” 160
65 2,5” 250
80 3” 440
100 4” 630

Butterfly Valve 12
DELTA SV1
IInstruction Manual: UK - rev. 8
APV UK
APV_SV1_UK-8_012017.qxp

9. Technical Data

9.4. Opening and closing times


The actuating times depend on the length of the air line between
the magnet valve to the air control and the actuator.
For air lines with a length of up to 1 m, the opening time for
butterfly valves DN 25/1” to DN 100/4” at 6 bar control air pressure
amounts to about 1 second. The closing time, after air shut-off,
depends on the nominal dimension and amounts to 2 to 3
seconds.
If the valves are subject to strong friction, e.g. through dry seals,
the actuating times extend accordingly.

9.4.1. Opening and closing times for butterfly valves


The opening and closing times of valves
equipped with a control unit can be adjusted.

opening time in sec.


closing time in sec.
control air pres. 6bar
DN Inch hose length 1 m
25 1” 1 sec. 1,5 sec.
40 1,5” 1 sec. 1,5 sec.
50 2” 1 sec. 1,5 sec.
65 2,5” 1 sec. 2,5 sec.
80 3” 1 sec. 3,0 sec.
100 4” 1,2 sec. 3,5 sec.
All time data are approximate values taken from
sample measurements.

9.5. Torque Md [Nm] for butterfly valves


DN Inch Md [Nm]
25 1” 10
40 1,5” 12
50 2” 16
65 2,5” 20
80 3” 22
100 4” 24

9.6. Control air consumption


at 6 bar control pressure
turning actuator K080 (spring/air)
per stroke 1,8 (NL)

13 Butterfly Valve
DELTA SV1
Instruction Manual: UK - rev. 8
APV UK
APV_SV1_UK-8_012017.qxp

10. Materials

- Valve disc 1.4571/1.4404 (DIN EN


10088)

- Housing flange
DN 25 - 100 1.4301/1.4404 (DIN EN
10088)
1” - 4” 1.4404 (DIN EN 10088)
- SV seal
standard: EPDM
option: HNBR, VMQ, FPM
- bearing bush polyamide PA 12

- handle polyamide PA 6.6

Actuator
- yoke, actuator 1.4301

- coupling 1.4308

- indicator PE - hard

- piston polyacetal POM


- spindle bearing polyamide PA 12

- air connection polyamide PA 6.6

Butterfly Valve 14
DELTA SV1
IInstruction Manual: UK - rev. 8
APV UK
APV_SV1_UK-8_012017.qxp

11. Maintenance

Scan for SV1/SVS1F Valve - The maintenance intervals depend on the application of the valve
Maintenance Video and should be determined by the operator carrying out regular
checks of the valve.

- There are a few wear parts on SV1 butterfly valves, principally


the SV seal and bearings.

- It is recommended that spare seals and bearings are


kept by the user.
Complete seal kits for the valve service are available
(see spare parts lists).

- If damaged seals are replaced, generally all seals and


bearings should be changed.
SV seal - Dismantling and installation of seals according to service
grease instructions.

- All seals must be slightly greased before their installation.


Grease SV seal according to illustration
- especially in the cross bores.
grease
- Assembly of valve and change of valve design NC or NO
by installation of the turning actuator according to Service
Instructions.
grease
- The inner parts of the actuator are maintenance free.

Attention! Use food-grade special grease being suited for the


respective seal material, only.

Recommendation:
APV assembly grease for EPDM, FPM, HNBR and NBR
(0,75 kg /can - ref. No. 000 70-01-019/93)
(60 g /tube - ref. No. 000 70-01-018/93)
or
APV asssembly grease for VMQ
(0,6 kg /can - ref. No. 000 70-01-017/93)
(60 g /tube - ref. No. 000 70-01-016/93)

!!! Do not use grease containing mineral oil for EPDM seals !!!

!!! Do not use Silicone-based grease for VMQ seals !!!

Less suited grease types can influence the function and


life time.

15 Butterfly Valve
DELTA SV1
Instruction Manual: UK - rev. 8
APV UK
APV_SV1_UK-8_012017.qxp

12. Service Instructions

12.1. Dismantling from the line system

Attention! The valve can only be dismantled via an additional


separate connection in the continuing pipeline.

Danger!
!
1. Shut off connecting lines, let down line pressure and drain
pipeline if possible.

2. Disconnect electric and pneumatic connections.

3. Release clamp connection at support of proximity switches.


Pull off proximity switch.

4. Release additional separate connection in the pipeline.

12.2. Dismantling of the actuating device


The item numbers refer to the spare parts drawings.

- Manual actuation with limit switch:


Screw off fastening screw (10) at the handle (8) and lift off handle.

- Manual actuation with adjusting device:


Screw off fastening screw at handle. Release both fastening
screws of the scale sheet, lift off handle with indicator and scale.
- Pneumatic actuator:
Remove the two fastening screws (7) at the yoke (9), lift off
actuator (13) to the top. Lift off coupling (12) and position
indicator (11).
Attention! If valve position indicators are installed,
see to the position of the operating cam
(see 12.6. and 12.7. ).
- Actuator with control unit:
Dismantling of actuator from yoke as described in chapter
Actuator. The control unit needs not be removed from the
actuator.

12.3. Dismantling of the inner parts


Dismantling is only possible via an additional separate connection
in the pipeline.
Seal ring (3), bearings (2), valve disc (5)
- Remove all fastening screws around the housing halves (4) and
part the housing halves.
- Remove the inner parts.

Butterfly Valve 16
DELTA SV1
IInstruction Manual: UK - rev. 8
APV UK
DELTA SV1 - DE - 7.qxp 16.09.2010

12. Service Instructions

12.4. Replacement of seals

1. Turn the disc (5) in the seal ring (3) into open position.

2. Remove bearings (2).

3. By a slight pressing, the seal ring (3) is deformed in its longitudinal


axis, and, thus, can be pulled off via the short bearing spindle.

4. Pull the seal ring (3) off the actuating spindle.

5. Clean the valve disc (5).

6. Grease the holes of the new seal ring (3) according to chapter 9
and insert the long actuating spindle of the valve disc (5).

7. Turn the disc (5) in the seal ring (3) into open position.

8. By slight pressure the seal ring (3) is deformed in its longitudinal


projecting ring axis, and, thus, can be pushed on via the short bearing spindle.
fig. 1 on the
disc bolt 12.5. Installation of seals and bearings

The current design of the valve disc has a projected ring


on the disc bolt (fig. 1).
The new valve disc can also be installed in old housings.

1. Place bearings (2) on the spindle of the disc.


The bearing bushes must be flush with the housing flange (fig. 2).

2. Insert the disc (5) in open position with seal ring (3) and
fig. 2 bearings (2) into one housing half (4).
bearing bush
3. Assemble the housing halves (4) with the screws (6)
alternately crosswise.
During the assembly of the housing halves, the projecting ring
presses into the plastic surface of the bearing bush and secures
the bearing bush against longitudinal movement.

Attention! Tightening of the screws (6), the valve disc (5)


must be in open position.
Damage of valve disc seal during assembly in
closed position is possible.

Bearings must not project the housing flange


bearing bush (fig. 3).
fig. 3
wrong assembly

bearing bush

17 Butterfly Valve
DELTA SV1
Instruction Manual: UK - rev. 8
APV UK
APV_SV1_UK-8_012017.qxp

12. Service Instructions

12.6. Installation of the actuating device

1. Observe the steps mentioned in 12.2. in reverse order.

2. With manual butterfly valves, the disc (5) and the handle (8) are
in a line.

3. Attach the position indicator (11) to align with the valve disc
onto the square of the actuating spindle of the disc (5).

4. Observe the design of the valve for the installation of the


coupling (12) on butterfly valves with feedback

- NC = normally closed
Valve disc (5) is closed, place coupling (12).
The upper operating cam must be adjusted to the upper
yoke bore.

- NO = normally open
Valve disc (5) is open, place coupling (12).
The lower operating cam must be adjusted to the lower
yoke bore.

5. Place actuator (13) with yoke and fasten them with the screws (7).

12.7. Installation of feedback units (proximity switches)

- Valve position indication OPEN:


Installation of the feedback unit in the lower yoke bore.

- Valve position indication CLOSED:


Installation of the feedback unit in the upper yoke bore.

- Insert proximity switch support into the yoke bore and fasten it.
Introduce the proximity switch into the support until it stops and fix
it by the clamp connection.

Butterfly Valve 18
DELTA SV1
IInstruction Manual: UK - rev. 8
APV UK
APV_SV1_UK-8_012017.qxp

13. Spare Parts Lists

The reference numbers of the spare parts for the different valve
designs and sizes are included in the attached spare parts
drawings with corresponding lists.
Please indicate the following data to place an order for spare parts:
- number of parts required
- reference number
- designation.

subject to change

19 Butterfly Valve
DELTA SV1
Instruction Manual: UK - rev. 8
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und Mitteilung
ihres Inhalts nicht gestattet, soweit nicht schriftlich zugestanden. Verstoß verpflichtet
zum Schadensersatz und kann strafrechtliche Folgen haben (Paragraph 18 UWG,
Paragraph 106 UrhG). Eigentum und alle Rechte, auch für Patenterteilung und
Gebrauchsmustereintragung, vorbehalten. SPX Flow Technology Rosista GmbH.

Name:
Datum:

Geprüft:
Ersatzteilliste: spare parts list
Trytko Trytko Trytko
30.01.14 30.10.14 06.07.16

DN25-100 1-4 inch 1+2S


Butterfly valve SV1-A-CU
Scheibenventil SV1-FZ-CU
Blatt
1
von
D-59425 Unna Germany

RN01.037-14
5
SPX Flow Technology Rosista GmbH
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und Mitteilung ihres
Inhalts nicht gestattet, soweit nicht schriftlich zugestanden. Verstoß verpflichtet
zum Schadensersatz und kann strafrechtliche Folgen haben (Paragraph 18 UWG,
Paragraph 106 UrhG). Eigentum und alle Rechte, auch für Patenterteilung und
Gebrauchsmustereintragung, vorbehalten. SPX Flow Technology Rosista GmbH.

Ersatzteilliste: spare parts list Datum: 30.01.14 30.10.14 06.07.16


Name: Trytko Trytko Trytko
Scheibenventil SV1-FZ-CU Geprüft: SPX Flow Technology Rosista GmbH
D-59425 Unna Germany
Butterfly valve SV1-A-CU Datum: Blatt 2 von 5
DN25-100 1-4 inch 1+2S Name:
Geprüft:
RN01.037-14
pos. Beschreibung Material DN25 1" DN40 1,5" DN50 2"
WS-Nr. WS-Nr. WS-Nr. WS-Nr. WS-Nr. WS-Nr.
item description material

Menge
quantity
ref.-no. ref.-no. ref.-no. ref.-no. ref.-no. ref.-no.
Verschlussstopfen 08-74-010/93
1 1 Kunststoff
Lock plug H16503
Lagerbuchse PA12 08-01-150/93
2 2
Bearing 30%GF H13832
Dichtung SV EPDM 58-33-278/93 58-33-325/93 58-33-378/93 58-33-425/93 58-33-428/93 58-33-475/93
1
Seal SV FDA-konform H77435 H77451 H77459 H77477 H77484 H77502
Dichtung SV FPM 58-33-278/73 58-33-325/73 58-33-378/73 58-33-425/73 58-33-428/73 58-33-475/73
1
Seal SV FDA-konform H77433 H77450 H77457 H77475 H77482 H77500
3
Dichtung SV HNBR 58-33-278/33 58-33-325/33 58-33-378/33 58-33-425/33 58-33-428/33 58-33-475/33
1
Seal SV FDA-konform H168744 H168263 H168745 H168930 H168826 H168234
Dichtung SV VMQ 58-33-278/13 58-33-325/13 58-33-378/13 58-33-425/13 58-33-428/13 58-33-475/13
1
Seal SV FDA-konform H77432 H77449 H77456 H77474 H77481 H77499
Gehäusehälfte 1.4404 09-93-277/42 09-94-319/42 09-93-377/42 09-94-419/42 09-93-427/42 09-94-469/42
2
Housing half matt/satin fin. H22883 H23562 H22928 H23588 H22980 H23611
4
Gehäusehälfte 1.4301 09-93-277/12 09-94-319/12 09-93-377/12 09-94-419/12 09-93-427/12 09-94-469/12
2
Housing half matt/satin fin. H22879 H22924 H22976
Klappe 08-55-276/43 08-55-318/43 08-55-376/43 08-55-418/43 08-55-426/43 08-55-468/43
5 1 1.4404
Disc H16037 H114442 H16047 H114440 H16059 H114977
Skt. Mutter 65-50-060/15
6 DIN EN 24032-A2 1.4301
Hex. Nut 4xM8 H79281
Skt. Schraube 65-01-095/15
7 2 DIN EN 24017-A2-70 1.4301
Hex. Screw M8x35 H78791
Skt. Schraube 67-01-085/15
8 2 DIN EN 24017-A2-70 1.4301
Hex. Screw M8x28 H78778
Laterne 15-40-030/17 15-40-816/17
9 1 1.4301
Yoke H173105 H170929
Skt. Schraube 65-01-080/15
10 2 DIN EN 24017-A2-70 1.4301
Hex. Screw M8x12 H78770
Zeiger 08-29-021/93
11 1 PE-HART
Position indicator H14634
Kupplungsstück 08-52-050/13
12 1 1.4308
Coupling H15865
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und Mitteilung ihres
Inhalts nicht gestattet, soweit nicht schriftlich zugestanden. Verstoß verpflichtet
zum Schadensersatz und kann strafrechtliche Folgen haben (Paragraph 18 UWG,
Paragraph 106 UrhG). Eigentum und alle Rechte, auch für Patenterteilung und
Gebrauchsmustereintragung, vorbehalten. SPX Flow Technology Rosista GmbH.

Ersatzteilliste: spare parts list Datum: 30.01.14 30.10.14 06.07.16


Name: Trytko Trytko Trytko
Scheibenventil SV1-FZ-CU Geprüft: SPX Flow Technology Rosista GmbH
D-59425 Unna Germany
Butterfly valve SV1-A-CU Datum: Blatt 3 von 5
DN25-100 1-4 inch 1+2S Name:
Geprüft:
RN01.037-14
pos. Beschreibung Material DN25 1" DN40 1,5" DN50 2"
WS-Nr. WS-Nr. WS-Nr. WS-Nr. WS-Nr. WS-Nr.
item description material

Menge
quantity
ref.-no. ref.-no. ref.-no. ref.-no. ref.-no. ref.-no.
Drehantrieb F/L in Eizelverpackung / 15-31-055/17
1 1.4301
Actuator spring/air with individual packaging H315054
13
Drehantrieb L/L in Eizelverpackung / 15-31-065/17
1 1.4301
Actuator double/air with individual packaging H333445
Scheibe 67-01-022/15
14 4 DIN 125 A=8,4 1.4301
Disk H79594
in Eizelverpackung /
Drehantrieb F/L für RME 15-37-070/17
15 1 with individual 1.4301
Actuator s/a for control-unit packaging H315055
CU4-T-Adapter PA6.6 GF30 08-48-601/93
16 1
CU4-T-Adapter schwarz H320475
Control-Unit CU PA6.6 GF30 siehe Betriebsanleitung CU
17 1
Control-Unit CU schwarz see manual CU

Pos. 3, 4, 5 nur im kompletten Dichtungssatz erhältlich


Item 3, 4, 5 available as complete seal kits only
Dichtungssatz 58-34-565/00 58-34-571/00 58-34-566/00 58-34-572/00 58-34-567/00 58-34-573/00
1 FPM
Seal kit H206225 H206249 H206229 H206253 H206233 H206257
Dichtungssatz 58-34-565/01 58-34-571/01 58-34-566/01 58-34-572/01 58-34-567/01 58-34-573/01
1 EPDM
Seal kit H206226 H206250 H206230 H206254 H206234 H206258
Dichtungssatz 58-34-565/02 58-34-571/02 58-34-566/02 58-34-572/02 58-34-567/02 58-34-573/02
1 VMQ
Seal kit H206227 H206251 H206231 H206255 H206235 H206259
Dichtungssatz 58-34-565/06 58-34-571/06 58-34-566/06 58-34-572/06 58-34-567/06 58-34-573/06
1 HNBR
Seal kit H206228 H206252 H206232 H206256 H206236 H206260
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und Mitteilung ihres
Inhalts nicht gestattet, soweit nicht schriftlich zugestanden. Verstoß verpflichtet
zum Schadensersatz und kann strafrechtliche Folgen haben (Paragraph 18 UWG,
Paragraph 106 UrhG). Eigentum und alle Rechte, auch für Patenterteilung und
Gebrauchsmustereintragung, vorbehalten. SPX Flow Technology Rosista GmbH.

Ersatzteilliste: spare parts list Datum: 30.01.14 30.10.14 06.07.16


Name: Trytko Trytko Trytko
Scheibenventil SV1-FZ-CU Geprüft: SPX Flow Technology Rosista GmbH
D-59425 Unna Germany
Butterfly valve SV1-A-CU Datum: Blatt 4 von 5
DN25-100 1-4 inch 1+2S Name:
Geprüft:
RN01.037-14
pos. Beschreibung Material DN65 2,5" 3" DN80 DN100 4"
WS-Nr. WS-Nr. WS-Nr. WS-Nr. WS-Nr. WS-Nr.
item description material

Menge
quantity
ref.-no. ref.-no. ref.-no. ref.-no. ref.-no. ref.-no.
Verschlussstopfen 08-74-010/93
1 1 Kunststoff
Lock plug H16503
Lagerbuchse PA12 08-01-150/93 08-01-151/93
2 2
Bearing 30%GF H13832 H13833
Dichtung SV EPDM 58-33-478/93 58-33-525/93 58-33-503/93 58-33-528/93 58-33-628/93 58-33-675/93
1
Seal SV FDA-konform H77509 H77532 H77528 H77539 H77579 H77601
Dichtung SV FPM 58-33-478/73 58-33-525/73 58-33-503/73 58-33-528/73 58-33-62478/73 58-33-675/73
1
Seal SV FDA-konform H77507 H77530 H77526 H77537 H77577 H77599
3
Dichtung SV HNBR 58-33-478/33 58-33-525/33 58-33-503/33 58-33-528/33 58-33-528/33 58-33-675/33
1
Seal SV FDA-konform H168827 H169235 H169236 H168832 H166721 H166722
Dichtung SV VMQ 58-33-478/13 58-33-525/13 58-33-503/13 58-33-528/13 58-33-528/13 58-33-675/13
1
Seal SV FDA-konform H77506 H77529 H77525 H77536 H77576 H77598
Gehäusehälfte 1.4404 09-93-477/42 09-94-519/42 09-93-552/42 09-93-527/42 09-93-627/42 09-94-669/42
2
Housing half matt/satin fin. H23039 H23640 H23123 H23092 H23154 H23684
4
Gehäusehälfte 1.4301 09-93-477/12 09-94-519/12 09-93-552/12 09-93-527/12 09-93-627/12 09-94-669/12
2
Housing half matt/satin fin. H23035 H23088 H23150
Klappe 08-55-476/43 08-55-518/43 08-55-527/43 08-55-526/43 08-55-626/43 08-55-668/43
5 1 1.4404
Disc H16071 H114978 H16090 H16082 H16102 H114979
Skt. Mutter 65-50-060/15 65-50-060/15
6 DIN EN 24032-A2 1.4301
Hex. Nut 4xM8 H79281 6xM8 H79281
Skt. Schraube 65-01-095/15
7 2 DIN EN 24017-A2-70 1.4301
Hex. Screw M8x35 H78791
Skt. Schraube 67-01-085/15 67-01-085/15
8 DIN EN 24017-A2-70 1.4301
Hex. Screw 2xM8x28 H78778 4xM8x28 H78778
Laterne 15-40-025/17
9 1 1.4301
Yoke H173103
Skt. Schraube 65-01-080/15
10 2 DIN EN 24017-A2-70 1.4301
Hex. Screw M8x12 H78770
Zeiger 08-29-021/93
11 1 PE-HART
Position indicator H14634
Kupplungsstück 08-52-050/13
12 1 1.4308
Coupling H15865
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und Mitteilung ihres
Inhalts nicht gestattet, soweit nicht schriftlich zugestanden. Verstoß verpflichtet
zum Schadensersatz und kann strafrechtliche Folgen haben (Paragraph 18 UWG,
Paragraph 106 UrhG). Eigentum und alle Rechte, auch für Patenterteilung und
Gebrauchsmustereintragung, vorbehalten. SPX Flow Technology Rosista GmbH.

Ersatzteilliste: spare parts list Datum: 30.01.14 30.10.14 06.07.16


Name: Trytko Trytko Trytko
Scheibenventil SV1-FZ-CU Geprüft: SPX Flow Technology Rosista GmbH
D-59425 Unna Germany
Butterfly valve SV1-A-CU Datum: Blatt 5 von 5
DN25-100 1-4 inch 1+2S Name:
Geprüft:
RN01.037-14
pos. Beschreibung Material DN65 2,5" 3" DN80 DN100 4"
WS-Nr. WS-Nr. WS-Nr. WS-Nr. WS-Nr. WS-Nr.
item description material

Menge
quantity
ref.-no. ref.-no. ref.-no. ref.-no. ref.-no. ref.-no.
Drehantrieb F/L in Eizelverpackung / 15-31-055/17
1 1.4301
Actuator spring/air with individual packaging H315054
13
Drehantrieb L/L in Eizelverpackung / 15-31-065/17
1 1.4301
Actuator double/air with individual packaging H333445
Scheibe 67-01-022/15
14 4 DIN 125 A=8,4 1.4301
Disk H79594
in Eizelverpackung /
Drehantrieb F/L für RME 15-37-070/17
15 1 with individual 1.4301
Actuator s/a for control-unit packaging H315055
CU4-T-Adapter PA6.6 GF30 08-48-601/93
16 1
CU4-T-Adapter schwarz H320475
Control-Unit CU PA6.6 GF30 siehe Betriebsanleitung CU
17 1
Control-Unit CU schwarz see manual CU

Pos. 3, 4, 5 nur im kompletten Dichtungssatz erhältlich


Item 3, 4, 5 available as complete seal kits only
Dichtungssatz 58-34-568/00 58-34-574/00 58-34-575/00 58-34-569/00 58-34-570/00 58-34-576/00
1 FPM
Seal kit H206237 H206261 H206265 H206241 H206245 H206269
Dichtungssatz 58-34-568/01 58-34-574/01 58-34-575/01 58-34-569/01 58-34-570/01 58-34-576/01
1 EPDM
Seal kit H206238 H206262 H206266 H206242 H206246 H206270
Dichtungssatz 58-34-568/02 58-34-574/02 58-34-575/02 58-34-569/02 58-34-570/02 58-34-576/02
1 VMQ
Seal kit H206239 H206263 H206267 H206243 H206247 H206271
Dichtungssatz 58-34-568/06 58-34-574/06 58-34-575/06 58-34-569/06 58-34-570/06 58-34-576/06
1 HNBR
Seal kit H206240 H206264 H206268 H206244 H206248 H206272
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und Mitteilung
ihres Inhalts nicht gestattet, soweit nicht schriftlich zugestanden. Verstoß verpflichtet
zum Schadensersatz und kann strafrechtliche Folgen haben (Paragraph 18 UWG,
Paragraph 106 UrhG). Eigentum und alle Rechte, auch für Patenterteilung und
Gebrauchsmustereintragung, vorbehalten. SPX Flow Technology Rosista GmbH.

Name:
Datum:

Geprüft:
Ersatzteilliste: spare parts list
Trytko Trytko
31.01.14 06.07.16

DN25-100 ; 1-4 inch 1+2S


Butterfly valve SV1- handle
Scheibenventil SV1 - Handbetätigung
Blatt
1
von
D-59425 Unna Germany

RN01.037.5-9
5
SPX Flow Technology Rosista GmbH
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und Mitteilung ihres
Inhalts nicht gestattet, soweit nicht schriftlich zugestanden. Verstoß verpflichtet
zum Schadensersatz und kann strafrechtliche Folgen haben (Paragraph 18 UWG,
Paragraph 106 UrhG). Eigentum und alle Rechte, auch für Patenterteilung und
Gebrauchsmustereintragung, vorbehalten. SPX Flow Technology Rosista GmbH.

Ersatzteilliste: spare parts list Datum: 31.01.14 06.07.16


Name: Trytko Trytko
Scheibenventil SV1-Handbetätigung Geprüft: SPX Flow Technology Rosista GmbH
D-59425 Unna Germany
Butterfly valve SV1-handle Datum: Blatt 2 von 5
DN25-100 ; 1-4 inch 1+2S Name:
Geprüft:
RN01.037.5-9
pos. Beschreibung Material DN25 1" DN40 1,5" DN50 2"
WS-Nr. WS-Nr. WS-Nr. WS-Nr. WS-Nr. WS-Nr.
item description material

Menge
quantity
ref.-no. ref.-no. ref.-no. ref.-no. ref.-no. ref.-no.
Verschlussstopfen 08-74-010/93
1 1 Kunststoff
Lock plug H16503
Lagerbuchse PA12 08-01-150/93
2 2
Bearing 30%GF H13832
Dichtung SV EPDM 58-33-278/93 58-33-325/93 58-33-378/93 58-33-425/93 58-33-428/93 58-33-475/93
1
Seal SV FDA-konform H77435 H77451 H77459 H77477 H77484 H77502
Dichtung SV FPM 58-33-278/73 58-33-325/73 58-33-378/73 58-33-425/73 58-33-428/73 58-33-475/73
1
Seal SV FDA-konform H77433 H77450 H77457 H77475 H77482 H77500
3
Dichtung SV HNBR 58-33-278/33 58-33-325/33 58-33-378/33 58-33-425/33 58-33-428/33 58-33-475/33
1
Seal SV FDA-konform H168744 H168263 H168745 H168930 H168826 H168234
Dichtung SV VMQ 58-33-278/13 58-33-325/13 58-33-378/13 58-33-425/13 58-33-428/13 58-33-475/13
1
Seal SV FDA-konform H77432 H77449 H77456 H77474 H77481 H77499
Gehäusehälfte 1.4404 09-93-277/42 09-94-319/42 09-93-377/42 09-94-419/42 09-93-427/42 09-94-469/42
1
Housing half matt/satin fin. H22883 H23562 H22928 H23588 H22980 H23611
4
Gehäusehälfte 1.4301 09-93-277/12 09-94-319/12 09-93-377/12 09-94-419/12 09-93-427/12 09-94-469/12
1
Housing half matt/satin fin. H22879 H22924 H22976
Klappe 08-55-276/43 08-55-318/43 08-55-376/43 08-55-418/43 08-55-426/43 08-55-468/43
5 1 1.4404
Disc H16037 H114442 H16047 H114440 H16059 H114977
Skt. Mutter 65-50-060/15
6 DIN EN 24032-A2 1.4301
Hex. Nut 4xM8 H79281
Skt. Schraube 67-01-085/15
7 DIN EN 24017-A2-70 1.4301
Hex. Screw 4xM8x28 H78778
Handbetätigung PA6.6 08-41-065/93
8 1
Handle 30% GF H15059
Skt. Schraube 65-01-037/15
9 1 DIN EN 24014-A2-70 1.4301
Hex. Screw M5x28 H78740
Sicherungsscheibe M5 67-01-010/93
10 1 1.4301
Safety disk M5 H79581
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und Mitteilung ihres
Inhalts nicht gestattet, soweit nicht schriftlich zugestanden. Verstoß verpflichtet
zum Schadensersatz und kann strafrechtliche Folgen haben (Paragraph 18 UWG,
Paragraph 106 UrhG). Eigentum und alle Rechte, auch für Patenterteilung und
Gebrauchsmustereintragung, vorbehalten. SPX Flow Technology Rosista GmbH.

Ersatzteilliste: spare parts list Datum: 31.01.14 06.07.16


Name: Trytko Trytko
Scheibenventil SV1-Handbetätigung Geprüft: SPX Flow Technology Rosista GmbH
D-59425 Unna Germany
Butterfly valve SV1-handle Datum: Blatt 3 von 5
DN25-100 ; 1-4 inch 1+2S Name:
Geprüft:
RN01.037.5-9
pos. Beschreibung Material DN25 1" DN40 1,5" DN50 2"
WS-Nr. WS-Nr. WS-Nr. WS-Nr. WS-Nr. WS-Nr.
item description material

Menge
quantity
ref.-no. ref.-no. ref.-no. ref.-no. ref.-no. ref.-no.
Pos. 1, 2, 3 nur im kompletten Dichtungssatz erhältlich
Item 1, 2, 3, available as complete seal kits only
Dichtungssatz 58-34-565/00 58-34-571/00 58-34-566/00 58-34-572/00 58-34-567/00 58-34-573/00
1 FPM
Seal kit H206225 H206249 H206229 H206253 H206233 H206257
Dichtungssatz 58-34-565/01 58-34-571/01 58-34-566/01 58-34-572/01 58-34-567/01 58-34-573/01
1 EPDM
Seal kit H206226 H206250 H206230 H206254 H206234 H206258
Dichtungssatz 58-34-565/02 58-34-571/02 58-34-566/02 58-34-572/02 58-34-567/02 58-34-573/02
1 VMQ
Seal kit H206227 H206251 H206231 H206255 H206235 H206259
Dichtungssatz 58-34-565/06 58-34-571/06 58-34-566/06 58-34-572/06 58-34-567/06 58-34-573/06
1 HNBR
Seal kit H206228 H206252 H206232 H206256 H206236 H206260
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und Mitteilung ihres
Inhalts nicht gestattet, soweit nicht schriftlich zugestanden. Verstoß verpflichtet
zum Schadensersatz und kann strafrechtliche Folgen haben (Paragraph 18 UWG,
Paragraph 106 UrhG). Eigentum und alle Rechte, auch für Patenterteilung und
Gebrauchsmustereintragung, vorbehalten. SPX Flow Technology Rosista GmbH.

Ersatzteilliste: spare parts list Datum: 31.01.14 06.07.16


Name: Trytko Trytko
Scheibenventil SV1-Handbetätigung Geprüft: SPX Flow Technology Rosista GmbH
D-59425 Unna Germany
Butterfly valve SV1-handle Datum: Blatt 4 von 5
DN25-100 ; 1-4 inch 1+2S Name:
Geprüft:
RN01.037.5-9
pos. Beschreibung Material DN65 2,5" 3" DN80 DN100 4"
WS-Nr. WS-Nr. WS-Nr. WS-Nr. WS-Nr. WS-Nr.
item description material

Menge
quantity
ref.-no. ref.-no. ref.-no. ref.-no. ref.-no. ref.-no.
Verschlussstopfen 08-74-010/93
1 1 Kunststoff
Lock plug H16503
Lagerbuchse PA12 08-01-150/93 08-01-151/93
2 2
Bearing 30%GF H13832 H13833
Dichtung SV EPDM 58-33-478/93 58-33-525/93 58-33-503/93 58-33-528/93 58-33-628/93 58-33-675/93
1
Seal SV FDA-konform H77509 H77532 H77528 H77539 H77579 H77601
Dichtung SV FPM 58-33-478/73 58-33-525/73 58-33-503/73 58-33-528/73 58-33-62478/73 58-33-675/73
1
Seal SV FDA-konform H77507 H77530 H77526 H77537 H77577 H77599
3
Dichtung SV HNBR 58-33-478/33 58-33-525/33 58-33-503/33 58-33-528/33 58-33-628/33 58-33-675/33
1
Seal SV FDA-konform H168827 H169235 H169236 H168832 H166721 H166722
Dichtung SV VMQ 58-33-478/13 58-33-525/13 58-33-503/13 58-33-528/13 58-33-628/13 58-33-675/13
1
Seal SV FDA-konform H77506 H77529 H77525 H77536 H77576 H77598
Gehäusehälfte I 1.4404 09-93-477/42 09-94-519/42 09-93-552/42 09-93-527/42 09-93-627/42 09-94-669/42
1
Housing half I matt/satin fin. H23039 H23640 H23123 H23092 H23154 H23684
4
Gehäusehälfte I 1.4301 09-93-477/12 09-94-519/12 09-93-552/12 09-93-527/12 09-93-627/12 09-94-669/12
1
Housing half I matt/satin fin. H23035 H23088 H23150
Klappe 08-55-476/43 08-55-518/43 08-55-527/43 08-55-526/43 08-55-626/43 08-55-668/43
5 1 1.4404
Disc H16071 H114978 H16090 H16082 H16102 H114979
Skt. Mutter 65-50-060/15 65-50-060/15
6 DIN EN 24032-A2 1.4301
Hex. Nut 4xM8 H79281 6xM8 H79281
Skt. Schraube 65-01-085/15 65-01-085/15
7 DIN EN 24017-A2-70 1.4301
Hex. Screw 4xM8x28 H78778 6xM8x28 H78778
Handbetätigung PA6.6 08-41-065/93
8 1
Handle 30% GF H15059
Skt. Schraube 65-01-037/15
9 1 DIN EN 24014-A2-70 1.4301
Hex. Screw M5x28 H78740
Sicherungsscheibe M5 67-01-010/93
10 1 1.4301
Safety disk M5 H79581
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und Mitteilung ihres
Inhalts nicht gestattet, soweit nicht schriftlich zugestanden. Verstoß verpflichtet
zum Schadensersatz und kann strafrechtliche Folgen haben (Paragraph 18 UWG,
Paragraph 106 UrhG). Eigentum und alle Rechte, auch für Patenterteilung und
Gebrauchsmustereintragung, vorbehalten. SPX Flow Technology Rosista GmbH.

Ersatzteilliste: spare parts list Datum: 31.01.14 06.07.16


Name: Trytko Trytko
Scheibenventil SV1-Handbetätigung Geprüft: SPX Flow Technology Rosista GmbH
D-59425 Unna Germany
Butterfly valve SV1-handle Datum: Blatt 5 von 5
DN25-100 ; 1-4 inch 1+2S Name:
Geprüft:
RN01.037.5-9
pos. Beschreibung Material DN65 2,5" 3" DN80 DN100 4"
WS-Nr. WS-Nr. WS-Nr. WS-Nr. WS-Nr. WS-Nr.
item description material

Menge
quantity
ref.-no. ref.-no. ref.-no. ref.-no. ref.-no. ref.-no.
Pos. 1, 2, 3 nur im kompletten Dichtungssatz erhältlich
Item 1, 2, 3, available as complete seal kits only
Dichtungssatz 58-34-568/00 58-34-574/00 58-34-575/00 58-34-569/00 58-34-570/00 58-34-576/00
1 FPM
Seal kit H206237 H206261 H206265 H206241 H206245 H206269
Dichtungssatz 58-34-568/01 58-34-574/01 58-34-575/01 58-34-569/01 58-34-570/01 58-34-576/01
1 EPDM
Seal kit H206238 H206262 H206266 H206242 H206246 H206270
Dichtungssatz 58-34-568/02 58-34-574/02 58-34-575/02 58-34-569/02 58-34-570/02 58-34-576/02
1 VMQ
Seal kit H206239 H206263 H206267 H206243 H206247 H206271
Dichtungssatz 58-34-568/06 58-34-574/06 58-34-575/06 58-34-569/06 58-34-570/06 58-34-576/06
1 HNBR
Seal kit H206240 H206264 H206268 H206244 H206248 H206272
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und Mitteilung
ihres Inhalts nicht gestattet, soweit nicht schriftlich zugestanden. Verstoß verpflichtet
zum Schadensersatz und kann strafrechtliche Folgen haben (Paragraph 18 UWG,
Paragraph 106 UrhG). Eigentum und alle Rechte, auch für Patenterteilung und
Gebrauchsmustereintragung, vorbehalten. SPX Flow Technology Rosista GmbH.

Ersatzteilliste: spare parts list Datum: 13.02.14


Name: Trytko
Handbetätigung SV-HL für Ventilstellungsmeldung Geprüft: SPX Flow Technology Rosista GmbH
D-59425 Unna Germany
Handle for butterfly valves SV-man. yoke for valve position indication Datum: Blatt 1 von 2
Name:
DN25-100; 1-4 zoll / inch Geprüft:
RN01.037.0
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und Mitteilung
ihres Inhalts nicht gestattet, soweit nicht schriftlich zugestanden. Verstoß verpflichtet
zum Schadensersatz und kann strafrechtliche Folgen haben (Paragraph 18 UWG,
Paragraph 106 UrhG). Eigentum und alle Rechte, auch für Patenterteilung und
Gebrauchsmustereintragung, vorbehalten. SPX Flow Technology Rosista GmbH.

Ersatzteilliste: spare parts list Datum: 13.02.14


Name: Trytko
Handbetätigung SV-HL für Ventilstellungsmeldung Geprüft: SPX Flow Technology Rosista GmbH
D-59425 Unna Germany
Handle for butterfly valves SV-man. yoke for valve position indication Datum: Blatt 2 von 2
Name:
DN25-100; 1-4 zoll / inch Geprüft:
RN01.037.0
DN40, 50 DN65-100
pos. Beschreibung Material DN25+1"
1,5", 2" 2,5"-4"
WS-Nr. WS-Nr. WS-Nr. WS-Nr. WS-Nr. WS-Nr.
item description material

Menge
quantity
ref.-no. ref.-no. ref.-no. ref.-no. ref.-no. ref.-no.
Handbetätigung 08-41-139/17 08-41-017/17 08-41-137/17
1 1.4301
Handle H15153 H174199 H15149
Skt. Schraube 65-01-037/15
1 1 DIN EN 24014-A2-70 1.4301
Hex. screw M5x28 H78740
Sicherungsscheibe 64-01-010/93
2 1 M5 1.4301
Safety washer H79581
Handbetätigung 08-41-065/93
3 1 PA6.6 30%GF
Handle H15059
Laterne 15-40-053/17 15-40-055/17 15-40-054/17
4 1 1.4301
Yoke H33746 H171201 H33748
Scheibe 67-01-022/15
5 6 DIN 125 A8,4 A2
Washer H79594
Skt. Schraube 65-01-095/17
6 2 DIN EN 24017-A2-70 1.4301
Hex. screw M8x35 H78791
Ronde 08-58-026/17
7 1 SV-H VSM ø85x4 1.4301
Round plate H153636
Cliepsgleitlager 08-01-094/93
8 1 MCM-12-04 Iglidur
Clip slide bearing H169101
Skt. Schraube 65-01-078/15
9 2 DIN EN 24014-A2-70 1.4301
Hex. screw M8x10 H158966
Kupplung SV-H VSM 08-52-051/17
10 1 1.4308
Coupling valve position indication H15866
Zeiger 08-29-021/93
11 1 PE-HART
Position indicator H14634
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und Mitteilung
ihres Inhalts nicht gestattet, soweit nicht schriftlich zugestanden. Verstoß verpflichtet
zum Schadensersatz und kann strafrechtliche Folgen haben (Paragraph 18 UWG,
Paragraph 106 UrhG). Eigentum und alle Rechte, auch für Patenterteilung und
Gebrauchsmustereintragung, vorbehalten. SPX Flow Technology Rosista GmbH.

Ersatzteilliste: spare parts list Datum: 22.11.12 12.03.14


Name: Trytko Trytko
Geprüft: Goebel SPX Flow Technology Rosista GmbH
Drehantrieb K080, K125, K180 F/L D-59425 Unna Germany
Datum: Blatt 1 von 2
Actuator K080, K125, K180 spring/air Name:
Geprüft:
RN 01.073

DRAT K080 DRAT K125 DRAT K180


Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und Mitteilung
ihres Inhalts nicht gestattet, soweit nicht schriftlich zugestanden. Verstoß verpflichtet
zum Schadensersatz und kann strafrechtliche Folgen haben (Paragraph 18 UWG,
Paragraph 106 UrhG). Eigentum und alle Rechte, auch für Patenterteilung und
Gebrauchsmustereintragung, vorbehalten. SPX Flow Technology Rosista GmbH.

Ersatzteilliste: spare parts list Datum: 22.11.12 12.03.14


Name: Trytko Trytko
Geprüft: Goebel SPX Flow Technology Rosista GmbH
Drehantrieb K080, K125, K180 F/L D-59425 Unna Germany
Datum: Blatt 2 von 2
Actuator K080, K125, K180 spring/air Name:
Geprüft:
RN 01.073
pos. Beschreibung Material K080 K125 K180
WS-Nr. WS-Nr. WS-Nr. WS-Nr. WS-Nr. WS-Nr.
item description material

Menge
quantity
ref.-no. ref.-no. ref.-no. ref.-no. ref.-no. ref.-no.
Drehantrieb komplett 1.4301 15-31-055/17 15-31-057/17 15-31-923/17
1
Actuator complete matt-glänzend H105500 H105502 H32589
Drehantrieb komplett 1.4301 15-31-055/13 15-31-057/13 15-31-923/13
1
Actuator complete poliert H135919 H131940 H32588
Drehantrieb Schweißteil 15-31-054/17 15-31-056/17 15-31-922/17
1 1 1.4301
Actuator welded H105499 H105501 H32587
Spindel komplett mit Lager 15-24-021/13 15-24-031/13 15-24-033/13
2 1 1.4301
Shaft complete with bearing H31494 H31502 H31504
Spindel 15-24-020/13 15-24-030/13 15-24-032/13
2.1 1 1.4301
Shaft H31493 H31501 H31503
Winkelverschraubung G1/8" schwenkbar Polyamid/ 08-63-221/93
3 1
Elbow union G1/8" slewable Glasf H16371
O-Ring 58-06-130/83
1 NBR
O-ring 32,2x3 H76965
4
O-Ring 58-06-222/73
1 FPM
O-ring 49,5x3 H77000
Lager für Drehantrieb 15-28-002/34
1 POM
Bearing for actuator H31673
5
Lager für Drehantrieb 15-28-009/63
1 PA12
Bearing for actuator H31684
Stellring 67-08-007/13 67-08-008/13
6 1 1.4301
Adjust ring H79757 H79758
Zyl. Kerbstift 67-15-035/13 67-15-036/13
7 1 DIN EN ISO 8740-V2A 1.4305
Cyl. pin 5x26 H79916 8x45 H79917
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und Mitteilung
ihres Inhalts nicht gestattet, soweit nicht schriftlich zugestanden. Verstoß verpflichtet
zum Schadensersatz und kann strafrechtliche Folgen haben (Paragraph 18 UWG,
Paragraph 106 UrhG). Eigentum und alle Rechte, auch für Patenterteilung und
Gebrauchsmustereintragung, vorbehalten. SPX Flow Technology Rosista GmbH.

Ersatzteilliste: spare parts list Datum: 28.03.13 08.05.14


Name: Trytko Trytko
Geprüft: SPX Flow Technology Rosista GmbH
Drehantrieb K080, K125, K180 F/L für Rückmeldeeinheit D-59425 Unna Germany
Datum: Blatt 1 von 2
Actuator K080, K125, K180 spring/air for control unit Name:
Geprüft:
RN 01.076
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und Mitteilung
ihres Inhalts nicht gestattet, soweit nicht schriftlich zugestanden. Verstoß verpflichtet
zum Schadensersatz und kann strafrechtliche Folgen haben (Paragraph 18 UWG,
Paragraph 106 UrhG). Eigentum und alle Rechte, auch für Patenterteilung und
Gebrauchsmustereintragung, vorbehalten. SPX Flow Technology Rosista GmbH.

Ersatzteilliste: spare parts list Datum: 28.03.13 08.05.14


Name: Trytko Trytko
Geprüft: SPX Flow Technology Rosista GmbH
Drehantrieb K080, K125, K180 F/L für Rückmeldeeinheit D-59425 Unna Germany
Datum: Blatt 2 von 2
Actuator K080, K125, K180 spring/air for control unit Name:
Geprüft:
RN 01.076
pos. Beschreibung Material K080 K125 K180
WS-Nr. WS-Nr. WS-Nr. WS-Nr. WS-Nr. WS-Nr.
item description material

Menge
quantity
ref.-no. ref.-no. ref.-no. ref.-no. ref.-no. ref.-no.
Drehantrieb komplett 1.4301 15-37-070/17 15-37-106/17 15-37-103/17
1
Actuator complete matt-glänzend H123937 H128942 H134034
Drehantrieb komplett 1.4301 15-37-070/13 15-37-106/13 15-37-103/13
1
Actuator complete poliert H316969 H327700 H328071
Drehantrieb Schweißteil 15-37-071/17 15-37-105/17 15-37-104/17
1 1 1.4301
Actuator welded H123936 H128940 H134503
Spindel komplett mit Lager 15-24-021/13 15-24-031/13 15-24-033/13
2 1 1.4301
Shaft complete with bearing H31494 H31502 H31504
Spindel 15-24-020/13 15-24-030/13 15-24-032/13
2.1 1 1.4301
Shaft H31493 H31501 H31503
O-Ring 58-06-130/83
1 OR 32,3x3 NBR
O-ring H76965
3
O-Ring 58-06-222/73
1 OR 49,5x3 FPM
O-ring H77000
Lager für Drehantrieb 15-28-002/34
1 POM
Bearing for actuator H31673
4
Lager für Drehantrieb 15-28-009/63
1 PA12
Bearing for actuator H31684
Stellring 67-08-007/13 67-08-008/13
5 1 1.4301
Adjust ring H79757 H79758
Zyl. Kerbstift 67-15-035/13 67-15-036/13
6 1 DIN EN ISO 8740-V2A 1.4305
Cyl. pin 5x26 H79916 8x45 H79917
O-Ring 58-06-426/83
7 1 OR 90x2 NBR
O-ring H143352
O-Ring 58-06-052/83
8 1 OR 15,3x2,4 NBR
O-ring H107914
Druckstück Drehantrieb 08-48-117/53
9 1 Hostaform
Thrust ring turning actuator H105080
APV DELTA SV1
B U T T E R F LY VA LV E

S P X F L O W SPX FLOW

Design Center Production


Gottlieb-Daimler-Straße 13 Stefana Rolbieskiego 2
D-59439 Holzwickede, Germany PL- Bydgoszcz 85-862, Poland
P: (+49) (0) 2301-9186-0 P: (+48) 52 566 76 00
F: (+49) (0) 2301-9186-300 F: (+48) 52 525 99 09

SPX FLOW reserves the right to incorporate the latest design and material changes without notice or obligation.
Scan for SV1/SVS1F Valve
Maintenance Video
Design features, materials of construction and dimensional data, as described in this manual, are provided for your information only
and should not be relied upon unless confirmed in writing. Please contact your local sales representative for product availability in your region.
For more information visit www.spxflow.com.

ISSUED 10/2016 - Translation of Original Manual


COPYRIGHT ©2016 SPX FLOW, Inc.

You might also like