F3 Series
F3 Series
F3 Series
Gearmotor / Reducer
F3
■Gearmotor / Gearmotor with Brake / Water-resistant,
Outdoor (IP65) Gearmotor / Gearmotor with Brake
Model and Type Designation 0.1kW‒0.4kW P. D4
Model and Type Designation 0.75kW‒2.2kW IE3 (Premium Efficiency) P. D5
Model and Type Designation 0.75kW‒2.2kW IE1 (Standard Efficiency) P. D6
Concentric Hollow Shaft Standard Model Lineup Indoor Type P. D8 Series
Concentric Hollow Shaft Standard Model Lineup Water-resistant Type P. D9
Concentric Solid Shaft Standard Model Lineup Indoor Type P. D10
Concentric Hollow Shaft 3-Phase Performance Table P. D14
Concentric Solid Shaft 3-Phase Performance Table P. D18
Concentric Hollow Shaft 3-Phase Outer Dimension Diagram P. D22
Concentric Solid Shaft 3-Phase Outer Dimension Diagram P. D34
D1
D2
Concentric Hollow Shaft and Concentric Solid Shaft
Gearmotor
Gearmotor with Brake
Water-resistant, Outdoor
Gearmotor
Gearmotor with Brake
Model and Type Designation
Standard Model Lineup
F3
Series
Number of Pole 4
R a t i n g Continuous Rating
Reduction Method Hypoid Gear and Helical Gear
Lubrication Method Grease Lubrication (Maintenance Free)
Reducer Output Shaft New JIS Key (JIS 1301-1996 Standard) Note) Key materials are included with the Concentric Solid Shaft Type.
Output Shaft Material S43C
Case Material Aluminium Die-cast (Frame No. 50: Aluminium Casting, Frame No. 55: Cast Iron)
Ambient Temperature −10℃‒+40℃ (Note)
Ambient Humidity 85% Max. (Without Any Dew Condensation)
D3
Model and Type Designation
Type Designation
Model and
0.1kW−0.4kW
F3 series 0.1kW‒0.4kW gearmotors and gearmotors with a brake are classified by
codes as shown below. Specify these codes in your inquiry and order.
Series Mount Motor Type Frame Shaft Reduction Motor Capacity Option Terminal Box Auxiliary Mark Spec. Designation
Number Location Ratio
F3 S M 25 80 T010 A
F3 F B 32 R 120 T040 W Z
F3 S W 45 450 T020 P E X AB
① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩ ⑪
①Series Name F3 :F3 Series
(Concentric Hollow Shaft, Concentric Solid Shaft)
S :Concentric Hollow Shaft
②Classification by Mount Form
F :Concentric Solid Shaft
M :Without Brake
B :With Brake
J :With Brake Manual Release Device(Option)
③Classification by Motor Type
Note) Only hollow shafts are available for
W :With Water-resistant Motor(Output Shaft Material SUS420J2) IP65
Water-resistant and Outdoor Types. V :With Water-resistant Brake(Output Shaft Material SUS420J2)IP65
G :With Outdoor Motor(Output Shaft Material S43C)IP65
H :With Outdoor Brake Motor(Output Shaft Material S43C)IP65
④Frame No. and Diameter of Output Shaft Diameter of output shaft (inner diameter for Concentric Hollow Shaft type and outer diameter for Concentric Solid Shaft type)
Hollow Shaft Solid Shaft
Gear Head
Blank L R T
⑥Reduction Ratio 5 : 1/5 − 1500 : 1/1500
T010 :3-Phase 0.1kW
T020 :3-Phase 0.2kW
T040 :3-Phase 0.4kW
⑦Motor Capacity
S100 :1-Phase 100W(capacitor operated)
200 :1-Phase 200W(capacitor operated)
400 :1-Phase 400W(capacitor operated)
Indoor Specification Water-resistant, Outdoor Specification
⑧⑨Options
・Power Supply Voltage A :Standard Voltage With A Model Terminal Box E :Standard Voltage With E Model Terminal Box
(* Please inquire regarding other 3-Phase : 200V/50Hz, 200V/60Hz, 220V/60Hz 3-Phase:200V/50Hz, 200V/60Hz, 220V/60Hz
voltages/frequencies.) WA :High Voltage With A Model Terminal Box WE :High Voltage With E Model Terminal Box
3-Phase:380V/50Hz, 400V/50Hz, 400V/60Hz, 440V/60Hz 3-Phase:380V/50Hz, 400V/50Hz, 400V/60Hz,
・Terminal Box
1-Phase:200V/50Hz, 200V/60Hz 440V/60Hz
Please specify A or Z for indoor specifications.
Note 1)A-Type Terminal Box is standard for
PA : High Voltage With A Model Terminal Box For 400V Brake Specifications *Excluding 50W PE : High Voltage With E Model Terminal Box For 400V Brake Specifications *Excluding 50W
3-phase. 3-Phase:380V/50Hz, 400V/50Hz, 400V/60Hz, 440V/60Hz 3-Phase :
Always add ""A"" as the suffix to the model. (Note) High Voltage with 200V brake specifications is "WA" (Note) High Voltage with 200V brake specifications is "WE"
When the field is blank, there is no terminal
box (lead type). Z :Standard Voltage With Z Model Terminal Box(For Use with Models with a Brake Built-in Rectifier Type)
Refer to the following pages for terminal box
specifications.
3-Phase:200V/50Hz, 200V/60Hz, 220V/60Hz
• Without Brake: Page E19 Note 3)
• With Brake Motor: Page E25
• Built-in Rectifier: Page E26-E30 WZ :High Voltage With Z Model Terminal Box(For Use with Models with a Brake Built-in Rectifier Type)
3-Phase:380V/50Hz, 400V/50Hz, 400V/60Hz, 440V/60Hz
Note 2)1-phase with a terminal box can be acquired
through special order. Note 3)
Refer to〈pages E25〉for more information.
Blank :Standard Voltage Without Terminal Box
Note 3)When an inverter is used, always provide 3-Phase:200V/50Hz, 200V/60Hz, 220V/60Hz
instructions for "AC Switching (A)" (custom
specification) when submitting an order. 1-Phase:100V/50Hz, 100V/60Hz
An inverter cannot be used with "AC
Switching (B)" and "DC Switching".
W :High Voltage Without Terminal Box
Refer to〈pages E26, E27 and E52〉for 3-Phase:200V/50Hz, 200V/60Hz, 220V/60Hz
more information.
This option is only available with 200V
1-Phase:100V/50Hz, 100V/60Hz
brake specifications. P : High Voltage Without Terminal Box For 400V Brake Specifications *Excluding 50W
The option is not available on 400V brake
specifications. 3-Phase:380V/50Hz, 400V/50Hz, 400V/60Hz, 440V/60Hz
(Note) High Voltage with 200V brake specifications is "W"
F3 S 45 N 5 M P 08 T N N T N
F3 F 32 T 20 M P 15 T W N T B4 X AA
F3 S 45 S 30 W P 22 T N N E N X T9HZ
① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩ ⑪ ⑫ ⑬ ⑭ ⑮
SUS420J2 S ─ ─ ─
⑤Reduction Ratio 5 : 1/5 − 450 : 1/450
M :Induction Standard Motor (IP44)
⑥Classification by Motor Type
W :Induction Water-resistant Motor (IP65)
⑦Motor Specs. P :IE3 Efficiency (Premium Efficiency)
08 :3-Phase 0.75kW
⑧Motor Capacity 15 :3-Phase 1.5kW
22 :3-Phase 2.2kW
⑨Number of Phase T :3-Phase
N :Standard Voltage 3-Phase 3Rated 200V/50Hz, 200V/60Hz, 220V/60Hz
⑩Power Supply Voltage
W :High Voltage 3-Phase 3Rated 380V/50Hz, 400V/50Hz, 400V/60Hz, 440V/60Hz
⑪Standard N :Japanese, European (CE Marking)
T :T Model Terminal Box (Steel Plate)
⑫Terminal Box E :E Model Terminal Box (Aluminium)
For models with a brake, the brake lead wire is housed inside the terminal Box. Please refer to〈page E25〉.
N :Without Brake
B2 :200V Brake Specification
B4 :400V Brake Specification
⑬Brake Specs
V2 :Water-resistant 200V Brake Specification
Note) There are no 1.5kW or 2.2kW
gearmotors with a brake. V4 :Water-resistant 400V Brake Specification
J2 :With Brake Manual Release Device (Option) 200V Brake Specification
J4 :With Brake Manual Release Mechanism (Option) 400V Brake Specification
Blank:Standard Specifications
⑭Auxiliary Mark
X :Mark for Special Additional Specs
Built-in Rectifier Hardwiring Indication Mark
Please refer to the list of specification marks on〈page E28-E29〉for details.
⑮Spec. Designation
Terminal Box Positioning Mark
Please refer to the list of specification marks on〈page E40-E51〉for details
D5
Model and Type Designation
Type Designation
Model and
F3 S M 45 80 075
F3 F B 55 R 120 150 W X AA
F3 S W 55 100 220 P E X T9HZ
① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩ ⑪
①Series Name F3 :F3 Series
(Concentric Hollow Shaft, Concentric Solid Shaft)
S :Concentric Hollow Shaft
②Classification by Mount Form
F :Concentric Solid Shaft
M Without Brake
B :With Brake
J :With Brake Manual Release Device(Option)
③Classification by Motor Type
Note) Only hollow shafts are available for
W :With Water-resistant Motor(Output Shaft Material SUS420J2) IP65
Water-resistant and Outdoor Types. V :With Water-resistant Brake(Output Shaft Material SUS420J2)IP65 Note)0.75kW only
G :With Outdoor Motor(Output Shaft Material S43C)IP65
H :With Outdoor Brake Motor(Output Shaft Material S43C)IP65 Note)0.75kW only
④Frame No. and Diameter of Output Shaft Diameter of output shaft (inner diameter for Concentric Hollow Shaft type and outer diameter for Concentric Solid Shaft type)
Hollow Shaft Solid Shaft
Gear Head
⑤Output Shaft
Placement Marks Motor
With the output shaft protruding from the left With the output shaft protruding from the right With the output shafts protruding from both sides
when looking from the input shaft side ( ) when looking from the input shaft side ( ) when looking from the input shaft side ( )
Blank L R T
⑥Reduction Ratio 5 : 1/5 − 1500 : 1/1500
075 :3-Phase 0.75kW
⑦Motor Capacity 150 :3-Phase 1.5kW
220 :3-Phase 2.2kW
Indoor Specification Water-resistant, Outdoor Specification Terminal Box
Blank:Standard Voltage With Terminal Box E :Standard Voltage E Model Terminal Box
3-Phase: 200V/50Hz, 200V/60Hz, 220V/60Hz 3-Phase:200V/50Hz, 200V/60Hz, 220V/60Hz
1-Phase: 100V/50Hz, 100V/60Hz
⑧⑨Options
・Power Supply Voltage W :High Voltage With Terminal Box WE:High Voltage E Model Terminal Box
(*Please inquire regarding other voltages/frequencies.) 3-Phase:380V/50Hz, 400V/50Hz, 400V/60Hz, 440V/60Hz 3-Phase: 380V/50Hz, 400V/50Hz, 400V/60Hz,
1-Phase:100V/50Hz, 100V/60Hz 440V/60Hz
P :High Voltage With Terminal Box For 400V Brake Specifications PE :High Voltage E Model Terminal Box
3-Phase:380V/50Hz, 400V/50Hz, 400V/60Hz, 440V/60Hz 3-Phase: 380V/50Hz, 400V/50Hz, 400V/60Hz, 440V/60Hz
(Note) High Voltage with 200V brake specifications is "W" (Note) High Voltage with 200V brake specifications is "WE"
Blank : Standard Specifications
⑩Auxiliary Mark
X :Mark for Special Additional Specs
Terminal Box Positioning Mark
⑪Spec. Designation
Please refer to the lists of specification marks on〈page E40-E51〉for details.
D6
Model and
Type Designation
D7
Standard Model Lineup
Lineup
Standard Model
3-Phase 0.1kW
1-Phase 100W
Note 1)
Note 2)
3-Phase 0.2kW
1-Phase 200W
Note 2)
3-Phase 0.4kW
Gearmotor
1-Phase 400W
Gearmotor
with Brake
Note 2)
Note 2)
3-Phase 1.5kW
3-Phase 2.2kW
Note 1)High reduction ratio (1/300 and above) is not available for 1-Phase 100W.
2)A small frame no. type.
3)The models enclosed with " " are the low torque type. Special care should be given to
the allowable torque in the performance table.
D8
Lineup
Standard Model
Standard Model Lineup
Water-resistant Type
Water-resistant Note 1)
Gearmotor with
Brake
3-Phase 0.2kW
Outdoor Gearmotor
Outdoor Note 1)
Gearmotor with
Brake
3-Phase 0.4kW
Water-resistant Note 1)
Gearmotor
3-Phase 0.75kW
Water-resistant
Gearmotor with
Brake
Note 1)
3-Phase 1.5kW
Water-resistant
Gearmotor
3-Phase 2.2kW
D9
Standard Model Lineup
Lineup
Standard Model
3-Phase 0.1kW
Note 1)
3-Phase 0.2kW
Note 1)
Gearmotor
3-Phase 0.4kW
Gearmotor
with Brake
Gearmotor Equipped
with Brake Manual Note 1)
Release Device
(Optional Specs.)
3-Phase 0.75kW
Note 1)
3-Phase 1.5kW
3-Phase 2.2kW
D10
Standard Model
D11
Lineup
D12
Concentric Hollow Shaft and Concentric Solid Shaft
Gearmotor
Gearmotor with Brake
Water-resistant, Outdoor
Gearmotor
Gearmotor with Brake
Performance Table / F3
Series
F3F
Type
3-Phase
【Remarks】
●Values in the parenthesis in the performance table / dimension diagram are the values of gearmotor with brake.
●The output shaft rotation speed is the value corresponding to the motor synchronous speed and the nominal reduction ratio.
●The key for the outout shaft is not attached to this model.
●The areas shaded with in the performance table show that rotation occurs clockwise as viewed from the side with arrow Ⓐ in
the diagram below if hardwired as shown on〈page E18,E34〉(normal rotation).
●In the case of the Concentric Hollow Shaft, the L shaft rotates clockwise, and the R and T shafts rotate counterclockwise as viewed
from the output shaft.
D13
Lineup
Standard Model
Concentric Hollow Shaft F3 Series (F3S Type)
Output Shaft Output Shaft Output Shaft Output Shaft Outer Dimension
Allowable
Rated Rotation Speed Allowable Torque Allowable O.H.L. Diagram
Capacity Power Rated Actual Thrust Load
Frequency Rotation Frame Reduction
Motor Supply Current Reduction
Speed Number Ratio
Specification Ratio r/min N・m Kgf・m Indoor Type
N Kgf N Kgf
Water-resistant Type
V Hz A r/min 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz
*1/240 1/240 6.3 7.5 101 98 10.3 10 2550 260 637 65
1/200 1/200 7.5 9 98 81 10 8.3 2550 260 637 65
1/160 1/160 9.4 11.3 78 66 8 6.7 2550 260 637 65 P.D22
25
1/120 1/120 12.5 15 59 49 6 5 2550 260 637 65 P.D28
1/100 19/1880 15 18 49 41 5 4.2 2550 260 637 65
1/80 1/80 18.8 22.5 39 32 4 3.3 2550 260 637 65
1/60 1/59 25 30 31 25 3.2 2.6 1860 190 471 48
200 50 0.61 1420 1/50 1/50 30 36 25 22 2.6 2.2 1860 190 471 48
3-Phase
200 60 0.54 1700 1/40 1/40 37.5 45 21 18 2.1 1.8 1810 185 451 46
0.1kW
220 60 0.54 1720 1/30 2/59 50 60 16 13 1.6 1.3 1670 170 422 43
1/25 1/25 60 72 13 11 1.3 1.1 1570 160 392 40
P.D22
20 1/20 1/20 75 90 11 8.6 1.1 0.88 1470 150 373 38
P.D28
1/15 1/15 100 120 7.7 6.5 0.79 0.66 1320 135 333 34
1/12.5 2/25 120 144 6.5 5.4 0.66 0.55 1270 130 316 32
1/10 1/10 150 180 5.2 4.3 0.53 0.44 1180 120 294 30
1/7.5 2/15 200 240 3.8 3.2 0.39 0.33 1080 110 270 28
1/5 1/5 300 360 2.5 2.2 0.26 0.22 980 100 244 25
*1/240 1/240 6.3 7.5 184 184 18.8 18.8 3140 320 785 80
*1/200 1/200 7.5 9 184 175 18.8 17.9 3140 320 785 80
1/160 1/160 9.4 11.3 169 140 17.9 14.3 3140 320 785 80 P.D23
30
1/120 1/120 12.5 15 126 105 12.9 10.7 3140 320 785 80 P.D29
1/100 19/1880 15 18 105 87 10.7 8.9 3140 320 785 80
1/80 1/80 18.8 22.5 84 71 8.6 7.2 3090 315 775 79
1/60 1/60 25 30 67 55 6.8 5.6 2550 260 637 65
1/50 1/50 30 36 55 46 5.6 4.7 2450 250 613 63
1/40 1/40 37.5 45 44 37 4.5 3.8 2300 235 576 59
1/30 1/30 50 60 33 27 3.4 2.8 2110 215 527 54
1/25 1/25 60 72 27 24 2.8 2.4 2010 205 502 51
P.D22
200 50 1.1 1420 25 1/20 1/20 75 90 23 19 2.3 1.9 1860 190 466 48
3-Phase P.D28
200 60 1.0 1710 1/15 1/15 100 120 17 14 1.7 1.4 1720 175 429 44
0.2kW
220 60 1.0 1720 1/12.5 19/235 120 144 14 12 1.4 1.2 1620 165 405 41
1/10 1/10 150 180 11 9.2 1.1 0.94 1520 155 380 39
1/7.5 2/15 200 240 8.3 7 0.85 0.71 1370 140 342 35
1/5 1/5 300 360 5.5 4.6 0.56 0.47 1230 125 307 31
1/30 2/59 50 60 33 27 3.4 2.8 1670 170 422 43
1/25 1/25 60 72 27 24 2.8 2.4 1570 160 392 40
1/20 1/20 75 90 23 19 2.3 1.9 1470 150 373 38
20 1/15 1/15 100 120 17 14 1.7 1.4 1320 135 333 34 P.D22
(Small Frame No.)
1/12.5 2/25 120 144 14 12 1.4 1.2 1270 130 316 32 P.D28
1/10 1/10 150 180 11 9.2 1.1 0.94 1180 120 294 30
1/7.5 2/15 200 240 8.3 7 0.85 0.71 1080 110 270 28
1/5 1/5 300 360 5.5 4.6 0.56 0.47 980 100 244 25
*1/240 1/240 6.3 7.5 270 270 27.6 27.6 3630 370 912 93
*1/200 1/200 7.5 9 270 270 27.6 27.6 3630 370 912 93
*1/160 1/160 9.4 11.3 270 270 27.6 27.6 3630 370 912 93 P.D24
35
1/120 1/120 12.5 15 253 211 25.8 21.5 3530 360 883 90 P.D30
1/100 19/1880 15 18 211 175 21.5 17.9 3530 360 883 90
1/80 1/80 18.8 22.5 169 140 17.2 14.3 3480 355 873 89
1/60 1/60 25 30 133 111 13.6 11.3 3090 315 767 78
1/50 1/50 30 36 111 92 11.3 9.4 2990 305 747 76
1/40 1/40 37.5 45 88 74 9 7.5 2840 290 711 73
1/30 1/30 50 60 67 55 6.8 5.6 2650 270 662 68
1/25 1/25 60 72 55 46 5.6 4.7 2550 260 637 65
P.D23
200 50 2.1 1410 30 1/20 1/20 75 90 44 37 4.5 3.8 2400 245 600 61
3-Phase P.D29
200 60 1.8 1690 1/15 1/15 100 120 33 27 3.4 2.8 2160 220 539 55
0.4kW
220 60 1.8 1710 1/12.5 19/235 120 144 27 24 2.8 2.4 2060 210 506 52
1/10 1/10 150 180 23 19 2.3 1.9 1910 195 475 48
1/7.5 2/15 200 240 17 14 1.7 1.4 1760 180 438 45
1/5 1/5 300 360 11 9.2 1.1 0.94 1520 155 375 38
1/30 1/30 50 60 67 55 6.8 5.6 2110 215 527 54
1/25 1/25 60 72 55 46 5.6 4.7 2010 205 502 51
1/20 1/20 75 90 44 37 4.5 3.8 1860 190 466 48
25 1/15 1/15 100 120 33 27 3.4 2.8 1720 175 429 44 P.D22
(Small Frame No.)
1/12.5 19/235 120 144 27 24 2.8 2.4 1620 165 405 41 P.D28
1/10 1/10 150 180 23 19 2.3 1.9 1520 155 380 39
1/7.5 2/15 200 240 17 14 1.7 1.4 1370 140 342 35
1/5 1/5 300 360 11 9.2 1.1 0.94 1230 125 307 31
Note 1) The allowable O.H.L. are the values measured at the position of 20mm from the edge of output shaft.
2) Please be sure to read the remarks stated on〈page D13〉regarding the rotation method of output shaft.
3) The models marked with * are limited torque type. Be sure to refer to the allowable torque in the performance table.
D14
Lineup
Standard Model
0.75kW−2.2kW IE3 (Premium Efficiency)
Output Shaft Output Shaft Output Shaft Output Shaft Outer Dimension
Allowable
Rated Rotation Speed Allowable Torque Allowable O.H.L. Diagram
Capacity Power Rated Actual Thrust Load
Frequency Rotation Frame Reduction
Motor Supply Current Reduction
Speed Number Ratio
Specification Ratio r/min N・m Kgf・m Indoor Type
N Kgf N Kgf
Water-resistant Type
V Hz A r/min 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz
*1/240 1/240 6.3 7.5 554 554 56.5 56.5 5190 530 1275 130
*1/200 1/200 7.5 9 554 554 56.5 56.5 5190 530 1275 130
*1/160 1/160 9.4 11.3 554 526 56.5 53.7 5190 530 1275 130 P.D25
45
1/120 1/120 12.5 15 473 395 48.3 40.3 4750 485 1177 120 P.D31
1/100 19/1880 15 18 395 328 40.3 33.5 4750 485 1177 120
1/80 1/80 18.8 22.5 316 263 32.2 26.8 4750 485 1177 120
1/60 1/60 25 30 249 208 25.4 21.2 3480 355 870 89
1/50 1/50 30 36 208 173 21.2 17.7 3480 355 870 89
1/40 1/40 37.5 45 166 138 16.9 14.1 3480 355 870 89
1/30 1/30 50 60 124 104 12.7 10.6 3280 335 821 84
1/25 1/25 60 72 104 86 10.6 8.8 3190 325 796 81
P.D24
200 50 3.2 1440 35 1/20 1/20 75 90 83 70 8.5 7.1 2990 305 747 76
3-Phase P.D30
200 60 3.0 1720 1/15 1/15 100 120 63 52 6.4 5.3 2740 280 686 70
0.75kW
220 60 2.9 1740 1/12.5 19/235 120 144 52 43 5.3 4.4 2600 265 669 68
1/10 1/10 150 180 41 34 4.2 3.5 2450 250 613 63
1/7.5 2/15 200 240 31 25 3.2 2.6 2250 230 567 58
1/5 1/5 300 360 21 18 2.1 1.8 1960 200 500 51
1/30 1/30 50 60 124 104 12.7 10.6 2650 270 662 68
1/25 1/25 60 72 104 86 10.6 8.8 2550 260 637 65
1/20 1/20 75 90 83 70 8.5 7.1 2400 245 600 61
30 1/15 1/15 100 120 63 52 6.4 5.3 2160 220 539 55 P.D23
(Small Frame No.)
1/12.5 19/235 120 144 52 43 5.3 4.4 2060 210 506 52 P.D29
1/10 1/10 150 180 41 34 4.2 3.5 1910 195 475 48
1/7.5 2/15 200 240 31 25 3.2 2.6 1760 180 438 45
1/5 1/5 300 360 21 18 2.1 1.8 1520 155 375 38
*1/240 1/240 6.3 7.5 1264 1264 129 129 9800 1000 2452 250
*1/200 1/200 7.5 9 1264 1264 129 129 9020 920 2256 230
1/160 1/160 9.4 11.3 1264 1049 129 107 8330 850 2059 210 P.D27
55
1/120 1/120 12.5 15 947 789 96.6 80.5 7500 765 1863 190 P.D32
1/100 1/100 15 18 789 658 80.5 67.1 6420 655 1618 165
1/80 1/80 18.8 22.5 631 526 64.4 53.7 6420 655 1618 165
1/60 1/60 25 30 498 416 50.8 42.4 4750 485 1067 109
1/50 1/50 30 36 416 345 42.4 35.2 4750 485 1067 109
1/40 1/40 37.5 45 332 276 33.9 28.2 4750 485 1067 109
1/30 1/30 50 60 249 208 25.4 21.2 4750 485 1067 109
1/25 1/25 60 72 208 173 21.2 17.7 4700 480 1067 109
P.D25
200 50 6.4 1450 45 1/20 1/20 75 90 166 138 16.9 14.1 4460 455 1067 109
3-Phase P.D31
200 60 6.0 1740 1/15 1/15 100 120 124 104 12.7 10.6 4070 415 1067 109
1.5kW
220 60 5.7 1750 1/12.5 19/235 120 144 104 86 10.6 8.8 3920 400 1040 106
1/10 1/10 150 180 83 70 8.5 7.1 3630 370 967 99
1/7.5 2/15 200 240 63 52 6.4 5.3 3330 340 900 92
1/5 1/5 300 360 41 34 4.2 3.5 2940 300 800 82
1/30 1/30 50 60 249 208 25.4 21.2 3280 335 821 84
1/25 1/25 60 72 208 173 21.2 17.7 3190 325 796 81
1/20 1/20 75 90 166 138 16.9 14.1 2990 305 747 76
35 1/15 1/15 100 120 124 104 12.7 10.6 2740 280 686 70 P.D24
(Small Frame No.)
1/12.5 19/235 120 144 104 86 10.6 8.8 2600 265 669 68 P.D30
1/10 1/10 150 180 83 70 8.5 7.1 2450 250 613 63
1/7.5 2/15 200 240 63 52 6.4 5.3 2250 230 567 58
1/5 1/5 300 360 41 34 4.2 3.5 1960 200 500 51
*1/120 1/120 12.5 15 1264 1156 129 118 7500 765 1863 190
P.D27
55 1/100 1/100 15 18 1156 964 118 98.4 6420 655 1618 165
P.D32
1/80 1/80 18.8 22.5 926 771 94.5 78.7 6420 655 1618 165
1/60 1/60 25 30 731 609 74.6 62.1 5240 535 1275 130
P.D26
50 1/50 1/50 30 36 609 508 62.1 51.8 5240 535 1275 130
P.D32
1/40 1/40 37.5 45 487 406 49.7 41.4 5240 535 1275 130
200 50 8.8 1450 366 305 4750
3-Phase 1/30 1/30 50 60 37.3 31.1 485 1067 109
200 60 8.4 1740
2.2kW 1/25 1/25 60 72 305 254 31.1 25.9 4750 485 1067 109
220 60 7.9 1750
1/20 1/20 75 90 244 203 24.9 20.7 4750 485 1067 109
1/15 1/15 100 120 182 152 18.6 15.5 4410 450 1067 109 P.D25
45
1/12.5 19/235 120 144 152 126 15.5 12.9 4120 420 1040 106 P.D31
1/10 1/10 150 180 122 102 12.4 10.4 3920 400 967 99
1/7.5 2/15 200 240 91 76 9.3 7.8 3530 360 900 92
1/5 1/5 300 360 61 51 6.2 5.2 3140 320 800 82
Note 1) The allowable O.H.L. are the values measured at the position of 20mm from the edge of output shaft.
2) Please be sure to read the remarks stated on〈page D13〉regarding the rotation method of output shaft.
3) The models marked with * are limited torque type. Be sure to refer to the allowable torque in the performance table.
D15
Lineup
Standard Model
Concentric Hollow Shaft F3 Series (F3S Type)
Output Shaft Output Shaft Output Shaft Output Shaft Outer Dimension
Allowable
Rated Rotation Speed Allowable Torque Allowable O.H.L. Diagram
Capacity Power Rated Actual Thrust Load
Frequency Rotation Frame Reduction
Motor Supply Current Reduction
Speed Number Ratio
Specification Ratio r/min N・m Kgf・m Indoor Type
N Kgf N Kgf
Water-resistant Type
V Hz A r/min 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz
*1/240 1/240 6.3 7.5 554 554 56.5 56.5 5190 530 1275 130
*1/200 1/200 7.5 9 554 554 56.5 56.5 5190 530 1275 130
*1/160 1/160 9.4 11.3 554 526 56.5 53.7 5190 530 1275 130 P.D25
45
1/120 1/120 12.5 15 473 395 48.3 40.3 4750 485 1177 120 P.D31
1/100 19/1880 15 18 395 328 40.3 33.5 4750 485 1177 120
1/80 1/80 18.8 22.5 316 263 32.2 26.8 4750 485 1177 120
1/60 1/60 25 30 249 208 25.4 21.2 3480 355 870 89
1/50 1/50 30 36 208 173 21.2 17.7 3480 355 870 89
1/40 1/40 37.5 45 166 138 16.9 14.1 3480 355 870 89
1/30 1/30 50 60 124 104 12.7 10.6 3280 335 821 84
1/25 1/25 60 72 104 86 10.6 8.8 3190 325 796 81
P.D24
200 50 3.2 1440 35 1/20 1/20 75 90 83 70 8.5 7.1 2990 305 747 76
3-Phase P.D30
200 60 3.0 1720 1/15 1/15 100 120 63 52 6.4 5.3 2740 280 686 70
0.75kW
220 60 2.9 1740 1/12.5 19/235 120 144 52 43 5.3 4.4 2600 265 669 68
1/10 1/10 150 180 41 34 4.2 3.5 2450 250 613 63
1/7.5 2/15 200 240 31 25 3.2 2.6 2250 230 567 58
1/5 1/5 300 360 21 18 2.1 1.8 1960 200 500 51
1/30 1/30 50 60 124 104 12.7 10.6 2650 270 662 68
1/25 1/25 60 72 104 86 10.6 8.8 2550 260 637 65
1/20 1/20 75 90 83 70 8.5 7.1 2400 245 600 61
30 1/15 1/15 100 120 63 52 6.4 5.3 2160 220 539 55 P.D23
(Small Frame No.)
1/12.5 19/235 120 144 52 43 5.3 4.4 2060 210 506 52 P.D29
1/10 1/10 150 180 41 34 4.2 3.5 1910 195 475 48
1/7.5 2/15 200 240 31 25 3.2 2.6 1760 180 438 45
1/5 1/5 300 360 21 18 2.1 1.8 1520 155 375 38
*1/240 1/240 6.3 7.5 1264 1264 129 129 9800 1000 2452 250
*1/200 1/200 7.5 9 1264 1264 129 129 9020 920 2256 230
1/160 1/160 9.4 11.3 1264 1049 129 107 8330 850 2059 210 P.D27
55
1/120 1/120 12.5 15 947 789 96.6 80.5 7500 765 1863 190 P.D32
1/100 1/100 15 18 789 658 80.5 67.1 6420 655 1618 165
1/80 1/80 18.8 22.5 631 526 64.4 53.7 6420 655 1618 165
1/60 1/60 25 30 498 416 50.8 42.4 4750 485 1067 109
1/50 1/50 30 36 416 345 42.4 35.2 4750 485 1067 109
1/40 1/40 37.5 45 332 276 33.9 28.2 4750 485 1067 109
1/30 1/30 50 60 249 208 25.4 21.2 4750 485 1067 109
1/25 1/25 60 72 208 173 21.2 17.7 4700 480 1067 109
P.D25
200 50 6.4 1450 45 1/20 1/20 75 90 166 138 16.9 14.1 4460 455 1067 109
3-Phase P.D31
200 60 6.0 1740 1/15 1/15 100 120 124 104 12.7 10.6 4070 415 1067 109
1.5kW
220 60 5.7 1750 1/12.5 19/235 120 144 104 86 10.6 8.8 3920 400 1040 106
1/10 1/10 150 180 83 70 8.5 7.1 3630 370 967 99
1/7.5 2/15 200 240 63 52 6.4 5.3 3330 340 900 92
1/5 1/5 300 360 41 34 4.2 3.5 2940 300 800 82
1/30 1/30 50 60 249 208 25.4 21.2 3280 335 821 84
1/25 1/25 60 72 208 173 21.2 17.7 3190 325 796 81
1/20 1/20 75 90 166 138 16.9 14.1 2990 305 747 76
35 1/15 1/15 100 120 124 104 12.7 10.6 2740 280 686 70 P.D24
(Small Frame No.)
1/12.5 19/235 120 144 104 86 10.6 8.8 2600 265 669 68 P.D30
1/10 1/10 150 180 83 70 8.5 7.1 2450 250 613 63
1/7.5 2/15 200 240 63 52 6.4 5.3 2250 230 567 58
1/5 1/5 300 360 41 34 4.2 3.5 1960 200 500 51
*1/120 1/120 12.5 15 1264 1156 129 118 7500 765 1863 190
P.D27
55 1/100 1/100 15 18 1156 964 118 98.4 6420 655 1618 165
P.D32
1/80 1/80 18.8 22.5 926 771 94.5 78.7 6420 655 1618 165
1/60 1/60 25 30 731 609 74.6 62.1 5240 535 1275 130
P.D26
50 1/50 1/50 30 36 609 508 62.1 51.8 5240 535 1275 130
P.D32
1/40 1/40 37.5 45 487 406 49.7 41.4 5240 535 1275 130
200 50 8.8 1450 366 305 4750
3-Phase 1/30 1/30 50 60 37.3 31.1 485 1067 109
200 60 8.4 1740
2.2kW 1/25 1/25 60 72 305 254 31.1 25.9 4750 485 1067 109
220 60 7.9 1750
1/20 1/20 75 90 244 203 24.9 20.7 4750 485 1067 109
1/15 1/15 100 120 182 152 18.6 15.5 4410 450 1067 109 P.D25
45
1/12.5 19/235 120 144 152 126 15.5 12.9 4120 420 1040 106 P.D31
1/10 1/10 150 180 122 102 12.4 10.4 3920 400 967 99
1/7.5 2/15 200 240 91 76 9.3 7.8 3530 360 900 92
1/5 1/5 300 360 61 51 6.2 5.2 3140 320 800 82
Note 1) The allowable O.H.L. are the values measured at the position of 20mm from the edge of output shaft.
2) Please be sure to read the remarks stated on〈page D13〉regarding the rotation method of output shaft.
3) The models marked with * are limited torque type. Be sure to refer to the allowable torque in the performance table.
D16
Standard Model
D17
Lineup
Lineup
Standard Model
Concentric Solid Shaft F3 Series (F3F Type)
Note 1) The allowable O.H.L. are the values in the central position of the output shaft.
2) Please be sure to read the remarks stated on〈page D13〉regarding the rotation method of output shaft.
3) The models marked with * are limited torque type. Be sure to refer to the allowable torque in the performance table.
D18
Lineup
Standard Model
0.75kW−2.2kW IE3 (Premium Efficiency)
Note 1) The allowable O.H.L. are the values in the central position of the output shaft.
2) Please be sure to read the remarks stated on〈page D13〉regarding the rotation method of output shaft.
3) The models marked with * are limited torque type. Be sure to refer to the allowable torque in the performance table.
D19
Lineup
Standard Model
Concentric Solid Shaft F3 Series (F3F Type)
Note 1) The allowable O.H.L. are the values in the central position of the output shaft.
2) Please be sure to read the remarks stated on〈page D13〉regarding the rotation method of output shaft.
3) The models marked with * are limited torque type. Be sure to refer to the allowable torque in the performance table.
D20
Standard Model
D21
Lineup
Diagrams
Outer Dimension
Concentric Hollow Shaft F3 Series (F3S Type)
2 2
4-M10×P1.5 4-M10×P1.5 117
37 37 28
□70
135
Flange surface
64.5(61)
The values within parentheses are of those with brake motors. 132(128.5) 78.5(95.5)
Frame No. 25
Fig.1 When the protective
cap is attached.
When the protective
cap is attached. (
A A)
Protective cap
F3S-25
(attachment)
D
Fig.2 Small Frame No. Type
B
E
(
A A)
When the protective When the protective
cap is attached. cap is attached.
Flange surface Flange surface
Protective cap
F3S-25
(attachment)
Protective cap
F3S-30
(attachment)
Protective cap
F3S-30
(attachment)
141
69.5
140 84.5
120 (
A A)
7 7
124 106 159 31 227.5(237.5)
33 58 33 Flange surface Flange surface 58 101
53 53
17 17 48 91
Protective cap 8
F3S-30
φ30H8 φ30H8 (attachment)
58 48
135
2 2 Flange surface
80
25 96 88
15.5
40.5 40.5
Protective cap
F3S-30
(attachment)
Protective cap
F3S-35
(attachment)
(95) (95)
Fig.2
When the protective When the protective 434.5(444.5)
cap is attached. cap is attached.
138 22
7 7 185 227.5(237.5)
142 124 68 117
38 66 38 Flange surface Flange surface
56 105
62 62
20 20 Protective cap 10
F3S-35
φ35H8 φ35H8
(attachment)
68
56
4-φ12.5 4-φ10.6 68 56
135
2 2 Flange surface
80
96 88
18 30
48 48
(95) (95)
Fig.3 38
142
66 38
When the protective When the protective
cap is attached. cap is attached.
138 185
37.5
499(524)
276.5(301.5)
7 7
20 20 Flange surface 124 68 117
62 62 56 105
Protective cap Flange surface
F3S-35 10
φ35H8 φ35H8 (attachment)
68 56
φ85h7 φ49 φ49 φ85h7 136 38.3 □178
4-φ12.5 98.5
4-φ10.6 68 56 119.5
142
2 2 Flange surface
φ20
4-M12 P1.75 4-M12 P1.75
80
30
18 125 88
Fig.4
48 48
Protective cap
F3S-35
(attachment)
Indoor Specification
Without Brake With Brake Indoor Specification
Capacity Capacity
TypeFig. Number Weight Fig. Number Type Weight
3-Phase 0.4kW F3SM-35-80∼240-T040(W)A 1 15kg 3-Phase 0.4kW F3SB-35-80∼240-T040(W,P)A 1 17kg
3-Phase 0.75kW【IE3】 F3S35N5∼60-MP08TN(W)NTN 2 21kg 3-Phase 0.75kW【IE3】 F3S35N5∼60-MP08TN(W)NTB2(B4) 2 23kg
3-Phase 1.5kW【IE3】 F3S35N5∼30-MP15TN(W)NTN 3 28kg 3-Phase 1.5kW【IE3 F3S35N5∼30-MP15TN(W)NTB2(B4) 3 31kg
3-Phase 0.75kW【IE1】 F3SM-35-5∼60-075(W) 4 17.5kg 3-Phase 0.75kW【IE1】 F3SB-35-5∼60-075(W,P) 4 19.5kg
3-Phase 1.5kW【IE1】 F3SM-35-5∼30-150(W) 5 24.5kg 3-Phase 1.5kW【IE1】 F3SB-35-5∼30-150(W,P) 5 27.5kg
D24
Diagrams
Outer Dimension
Frame No. 45
Fig.1 (108) (108)
When the protective When the protective (
A A)
cap is attached. cap is attached.
19.5
164 272 227.5(237.5)
168 7 7
150 87 185
50 68 50 Flange surface Flange surface 69 167
26 26 75 75
Protective cap 14
F3S-45
φ45H8 φ45H8
(attachment) 87
69
φ100h7 φ64 φ64 φ100h7 174 48.8 □156
4-φ20.5 69 103
4-φ17.5 87
119.5 135
2 Flange surface
2
Fig.2
(108) (108)
When the protective When the protective A(A)
cap is attached. cap is attached.
33
168 164 235 B
7 7
50 68 50 150 87 148
Flange surface 75 75 Flange surface 73 134
26 26
Protective cap
14
F3S-45
φ45H8 φ45H8
(attachment)
87 73
Fig.3
(
A A)
When the protective When the protective
cap is attached. cap is attached.
Protective cap
F3S-45
(attachment)
Fig.4
A(A)
When the protective When the protective
cap is attached. cap is attached.
Protective cap
F3S-45
(attachment)
D25
Diagrams
Outer Dimension
Concentric Hollow Shaft F3 Series (F3S Type)
φ20
2 2 Flange surface
3-M4
80
158 88
4-M16 P2.0 40 40 4-M16 P2.0
19 19
59 59
D26
Diagrams
Outer Dimension
Frame No. 55
Fig.1
(143) (143)
When the protective When the protective
cap is attached. cap is attached.
220 A(A)
216 22.5
8 8 336 276.5(301.5)
61 98 61 Flange surface 200
100 100 Flange surface
116 220
32 32 94 198
Protective cap 16
F3S-5055
(attachment)
φ55H8 φ55H8
130
108
2 2 Flange surface
4-M20×P2.5 4-M20×P2.5 φ25
3-M4 125 88
21.5 50 50 21.5
71.5 71.5
Fig.2
143 143 A(A)
When the protective When the protective
cap is attached. cap is attached.
(attachment)
φ55H8 φ55H8
φ120h7 φ120h7
φ79 φ79
4-φ20.5 4-φ17.5
2 2
4-M20×P2.5 71.5 71.5 4-M20×P2.5 B
D27
Diagrams
Outer Dimension
Concentric Hollow Shaft F3 Series (F3S Type)
Leg Mount Type Water-resistant, Outdoor Gearmotor /
Water-resistant, Outdoor Gearmotor with Brake
Frame No. 20
Fig.1 64 64
When the protective When the protective
(308)
cap is attached. cap is attached. 256.5
92 127
7 7
96 78 48.5 78.5
24 24 Flange surface Flange surface
48 39 39 38.5 68.5
13 13 Protective cap
6
F3S-20
φ20H8 φ20H8 (attachment)
48.5
φ53h7 φ53h7 38.5
φ29 φ29 97 22.8
4-φ10.5 4-φ8.6 38.5
48.5
2 2 108.5
4-M10×P1.5 4-M10×P1.5
37 37 28
□80
Protective cap
F3S-20
(attachment)
Frame No. 25
Fig.1 When the protective
cap is attached.
When the protective
cap is attached.
(A)
A
B
Flange surface Flange surface C
Protective cap D
F3S-25
(attachment)
E
F
114.5
2 2
4-M10×P1.5 4-M10×P1.5
39.5 39.5
□80 28
69.5
140
The values within parentheses are of those with brake motors.
2 2
K K H
M M 28
N □80
O
130.5
2 2 Flange surface
4-M10×P1.5 4-M10×P1.5
25
15.5 28
40.5 40.5 99 □80
40.5 82 40.5
□80 28
78
159
The values within parentheses are of those with brake motors.
D29
Diagrams
Outer Dimension
Concentric Hollow Shaft F3 Series (F3S Type)
Leg Mount Type Water-resistant, Outdoor Gearmotor /
Water-resistant, Outdoor Gearmotor with Brake
Frame No. 35
Fig.1 95 95 (475)
142 When the protective When the protective 417
Flange surface cap is attached. cap is attached. Flange surface 222
38 66 38 138
7 7 68 154
20 20 Protective cap 124 54 140
F3S-35 62 62 10
(attachment)
φ35H8 φ35H8
68
54
φ85h7 φ85h7
φ49 φ49 136 38.3 φ141
4-φ16.5 54
68
2 2 114.5
4-M16×P2 4-M16×P2
58 58 28
□80
69.5
Fig.2 142
(95)
When the protective
(95)
When the protective 434.5(504.5)
cap is attached. cap is attached.
185 22 227.5(297.5)
38 66 38 138
7 7 68 117
20 20 Flange surface 124 Flange surface 56 105
62 62 10
Protective cap
φ35H8 φ35H8 F3S-35
(attachment)
68 56
4-φ12.5 4-φ10.6 68 56
130.5
30 28
18
99 □80
48 48
68 56
2 2 4-M12×P1.75 4-M12×P1.75
Flange surface φ20
30 28
18 128 □80
48 48
Fig.4 (474.5)
95 95 405
When the protective When the protective 185
cap is attached. cap is attached.
142 Flange surface
138 Flange surface 68 117
38 38 7 124 7
66 56 105
20 20 Protective cap
F3S-35 62 62 10
(attachment)
φ35H8 φ35H8
68
56
φ85h7 φ85h7
φ49 φ49 136 38.3 φ162
4-φ12.5 4-φ10.6 56
68
2 2 126.5
4-M12×P1.75 4-M12×P1.75
48 48 28
□80
78
159
48 48 □80 28
86
179.5
The values within parentheses are of those with brake motors.
4-φ20.5 4-φ17.5 69
87
119.5 103 130.5
2 2 φ20
4-M20×P2.5 4-M20×P2.5 Flange surface
50 28
23 99 □80
73 73
(A)
Fig.2 108 108 A
When the protective When the protective
cap is attached. cap is attached. 272
168 164 87 185
50 50 Flange surface 7 7 Flange surface
68 150 69 167
26 26
Protective cap 75 75 14
F3S-45
φ45H8 φ45H8 (attachment)
87
69
φ100h7 φ100h7
φ64 φ64 174 48.8 φ160 φ162
4-φ20.5 4-φ17.5 69 103
87 119.5
126.5
2 2 φ20
4-M20×P2.5 73 73 4-M20×P2.5 28
□80
78
159
2 2 φ20
4-M16×P2.0 4-M16×P2.0
Flange surface
23 40 28
C □80
63 63
Flange surface
87 148
Flange surface
73 134
Protective cap 14
F3S-45
(attachment)
87
73
174 48.8 φ179 φ186
73 98.5
87 115
φ20 137.5
28
□80
110.5
D31
Diagrams
Outer Dimension
Concentric Hollow Shaft F3 Series (F3S Type)
Leg Mount Type Water-resistant, Outdoor Gearmotor /
Water-resistant, Outdoor Gearmotor with Brake
Frame No. 50
Fig.1 172
(120)
cap is attached.
(120)
When the protective When the protective
cap is attached. 657
168 304 43 310
55 62 55 Flange surface 7 7
154 118 186 21
29 29 77 77 Flange surface 102 170
Protective cap 14
F3S-5055
(attachment)
φ50H8 φ50H8
106 90
2 2 φ20
4-M16×P2.0 4-M16×P2.0
Flange surface 3-M4 28
19 40 40 19 161 □80
59 59
Fig.2
120 120 611
When the protective When the protective 304
cap is attached. cap is attached.
172 Flange surface 168 Flange surface 118 186
55 55 7 7
62 154 102 170
29 29 Protective cap
F3S-5055 77 77 14
(attachment)
φ50H8 φ50H8 106
90
φ110h7 φ74 φ74 φ110h7 212 53.8 φ186
90 121
4-φ16.5 4-φ14
106 137.3
137.5
2 2 φ20
4-M16×P2.0 4-M16×P2.0 □80 28
82 3-M4
59 59
110.5
86
The values within parentheses are of those with brake motors. 179.5
Frame No. 55
Fig.1 (143)
When the protective
(143)
When the protective
220 cap is attached. cap is attached. A
22.5
216 336 B
8 8
61 98 61 Flange surface 200 116 220
100 100 Flange surface 94 198
32 32
Protective cap 16
F3S-5055
(attachment)
φ55H8 φ55H8
130 108
2 2 Flange surface
4-M20×P2.5 4-M20×P2.5 φ25 C □80 28
3-M4
21.5 50 50 21.5
71.5 71.5
□80 28
2 2 φ25
4-M20×P2.5 71.5 71.5 4-M20×P2.5 3-M4
110.5
The values within parentheses are of those with brake motors.
D32
Outer Dimension
D33
Diagrams
Diagrams
Outer Dimension
Concentric Solid Shaft F3 Series (F3F Type)
37 37 37 37 37 37 28
□70
(57.5) (57.5) (57.5) 47.5
Flange
Flange surface
surface
Flange Flange Flange Flange
surface surface surface surface
D34
Diagrams
Outer Dimension
Frame No. 22
Fig.1
F G
(
A A)
B
Flange Flange
C
surface surface D
Flange Flange Flange Flange
surface surface surface surface
H H H
E
D35
Diagrams
Outer Dimension
Concentric Solid Shaft F3 Series (F3F Type)
Fig.4
Fig.4 241
230
234.5
230 296 A(A)
150 73 73 150 73 150 73 235
7 7 7 7 7 7 (250 )
75 75 75 75 75 75 87 148
65 65 65 65 73 134
Flange surface Flange surface
60 60 60 60 43
Flange surface Flange surface Flange surface Flange surface
φ40h6 φ40h6
φ40h6 φ40h6 87
73 12
φ100h7 φ100h7 φ100h7 174 φ186
4-φ16.5 4-φ14 4-φ16.5 4-φ14 4-φ16.5 4-φ14 73 98.5
87 115
D39
Diagrams
D40
Concentric Hollow Shaft
Gearmotor
Gearmotor with Brake
Performance Table /
Dimension Diagram
F3
Series
F3S
Type
1-Phase
【Remarks】
●Values in the parenthesis in the performance table / dimension
diagram are the values of gearmotor with brake.
●The output shaft rotation speed is the value corresponding to the
motor synchronous speed and the nominal reduction ratio.
●The key for the outout shaft is not attached to this model.
●The areas shaded with in the performance table show
that rotation occurs clockwise as viewed from the side with
arrow Ⓐ in the diagram below if hardwired as shown on〈page
E18〉(normal rotation).
●1-Phase 100W uses a capacitor-operated motor, making
starting torque 60‒80%.
D41
Lineup
Standard Model
Concentric Hollow Shaft F3 Series (F3S Type)
Output Shaft Output Shaft Output Shaft Output Shaft Outer Dimension
Allowable
Rated Rotation Speed Allowable Torque Allowable O.H.L. Diagram
Capacity Power Rated Actual Thrust Load
Frequency Rotation Frame Reduction
Motor Supply Current Reduction
Speed Number Ratio
Specification Ratio r/min N・m Kgf・m
N Kgf N Kgf Indoor Type
Note 1) The allowable O.H.L. are the values measured at the position of 20mm from the edge of output shaft.
2) Please be sure to read the remarks stated on〈page D41〉regarding the rotation method of output shaft.
3) The models marked with * are limited torque type. Be sure to refer to the allowable torque in the performance table.
D42
Standard Model
D43
Lineup
Diagrams
Outer Dimension
Concentric Hollow Shaft F3 Series (F3S Type)
2 2
4-M10×P1.5 4-M10×P1.5
37 37
100 (200 )
57.5
125.5
D44
Diagrams
Outer Dimension
Frame No. 25
Fig.1
79 79
When the protective When the protective 327.5
cap is attached. cap is attached.
114 159
7 7
118 Flange surface 100 Flange surface 53.5 105.5
27 64 27 43.5
50 50 95.5
14 14 Protective cap
F3S-25 8
2 2
4-M10×P1.5 4-M10×P1.5
39.5 39.5
57.5 100 (200 )
126.5
Fig.2
When the protective When the protective
cap is attached. cap is attached.
Flange surface Flange surface
Protective cap
F3S-25
(attachment)
D45
Diagrams
Outer Dimension
Concentric Hollow Shaft F3 Series (F3S Type)
Frame No. 35
D46
Outer Dimension
D47
Diagrams
D48
Concentric Hollow Shaft
Reducers
(Double Shaft Type)
Model and Type Designation
Standard Model Lineup
F3
Series
D49
Model and Type Designation
Type Designation
Model and
Series Mount Motor Type Frame Reduction Capacity Option Terminal Box Auxiliary Mark Spec. Designation
Number Ratio
F3 S 30 50 040
F3 S 45 240 075 X
① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩
④Frame No. and Diameter of Output Shaft Output Shaft Diameter (Inner Diameter)
Blank:Standard Specifications
⑦⑧Options
No option is available.
Blank:Standard Specifications
⑨Auxiliary Mark
X :Mark for Special Additional Specs.
⑩Spec. Designation
Note) Spec. Designation is not shown as a
part of the product model name on the Blank:Standard Specifications
nameplate. It is shown in the Spec.
Designation column on the nameplate.
Note 1)Please note that F3 series Double Shaft Type Reducers have the F3S type (Hollow Shaft) only, and do not have the F3F type (Solid Shaft).
D50
Lineup
Standard Model
Standard Model Lineup
F3S Type (Hollow Shaft) Model Lineup
4P Motor Frame Reduction Ratio
Type Capacity Number
Note The models enclosed with " " are the low torque type. Special care should be given to
the allowable torque in the performance table.
D51
D52
Concentric Hollow Shaft
Reducer
(Double Shaft Type)
Performance Table /
Dimension Diagram
F3
Series
【Remarks】
●The corresponding motor capacities are the values when using
F3S
Type
a 4-pole motor.
●The key for the outout shaft is not attached to this model.
■Relation for Rotating Direction(As viewed from the side with arrow Ⓐ in the diagram below)
The rotation directions shown by the arrows just show rotation in relation to
input/output shafts, and do not limit rotation direction.
A A
D53
Lineup
Standard Model
Concentric Hollow Shaft F3 Series (F3S Type)
Note 1) The allowable O.H.L. are the values measured at the position of 20mm from the edge of output shaft.
2) Please be sure to read the remarks stated on〈page D53〉regarding the rotation method of output shaft.
3) The models marked with * are limited torque type. Be sure to refer to the allowable torque in the performance table.
D54
Lineup
Standard Model
Equivalent of 0.75kW−2.2kW
Note 1) The allowable O.H.L. are the values measured at the position of 20mm from the edge of output shaft.
2) Please be sure to read the remarks stated on〈page D53〉regarding the rotation method of output shaft.
3) The models marked with * are limited torque type. Be sure to refer to the allowable torque in the performance table.
D55
Diagrams
Outer Dimension
Concentric Hollow Shaft F3 Series (F3S Type)
64 64
When the protective When the protective 208
cap is attached. cap is attached.
92 127
7 7 25
96 78 48.5 78.5
24 24 Flange surface Flange surface 22
48 39 39 38.5 68.5
13 13 Protective cap
6
F3S-20
φ20H8 φ20H8 (attachment)
48.5 13.5
38.5 φ12h6 4
φ53h7 φ53h7
φ29 φ29 97 22.8 φ115 φ114.5
4-φ10.5 4-φ8.6 38.5
48.5
2 2
4-M10×P1.5 4-M10×P1.5
37 37
Frame No. 25
79 79
When the protective When the protective A
cap is attached. cap is attached.
114 B
7 7 25
118 100 53.5 C
27 27 Flange surface Flange surface 22
64 50 50 43.5 D
14 14 Protective cap
F3S-25 8
2 2
4-M10×P1.5 39.5 39.5 4-M10×P1.5
D56
Diagrams
Outer Dimension
Frame No. 30
82 82
When the protective When the protective A
cap is attached. cap is attached.
120 B
7 106 7 G
124 Flange surface Flange surface 58 C
33 58 33 H
53 53 48 D
17 17 Protective cap
F3S-30 8
2 2
N P P N
Equivalent of 0.2kW F3S-30-80∼240-020 260 180 122 110 46 115 25 22 12h6 114.5 4 13.5 4-φ12.5 4-M12×P1.75 4-φ10.6 45.5 6.5kg
Equivalent of 0.4kW F3S-30-5∼60-040 258 159 101 91 48 128 30 27 15h6 127 5 17 4-φ10.5 4-M10×P1.5 4-φ8.6 40.5 6kg
Frame No. 35
95 95 A
When the protective When the protective B
cap is attached. cap is attached. F
142 Flange surface 7 138 Flange surface 68 C
38 38 124 7 G
66 56 D
20 20 Protective cap
F3S-35 62 62 10
(attachment)
φ35H8 φ35H8
68 K
E φH J
φ85h7 φ85h7
φ49 φ49 136 38.3 φI
L N E
68
2 2
M O O M
Equivalent of 0.4kW F3S-35-80∼240-040 316.5 222 154 140 54 30 27 15h6 127 5 17 4-φ16.5 4-M16×P2 ─ 58 9.5kg
Equivalent of 0.75kW F3S-35-5∼60-075 296.5 185 117 105 56 35 32 20h6 142 6 22.5 4-φ12.5 4-M12×P1.75 4-φ10.6 48 8kg
D57
Diagrams
Outer Dimension
Concentric Hollow Shaft F3 Series (F3S Type)
2 2 φ20
4-M20×P2.5 73 73 4-M20×P2.5
2 2 φ20
4-M16×P2.0 63 63 4-M16×P2.0
Frame No. 50
120 120
When the protective When the protective 475.5
cap is attached. cap is attached. 304
Flange surface 168 Flange surface 45
172 118 186
55 55 7 7 40
62 154 102 170
29 29 Protective cap
F3S-5055 77 77 14
(attachment)
φ50H8 φ50H8 106
φ30h6 8 33
90
φ110h7 φ74 φ74φ110h7 212 53.8
90 121
4-φ16.5 4-φ14
106 137.3
2 2 φ20
4-M16×P2.0 59 59 4-M16×P2.0 3-M4
D58
Diagrams
Outer Dimension
Frame No. 55
143 143 A
When the protective When the protective B
cap is attached. cap is attached. 336
216 C
220 Flange surface Flange surface 116 220
61 61 8 8
98 200 94 198
32 32 Protective cap 100 100 16
F3S-5055
(attachment)
φ55H8 φ55H8 130 E
φD
108 8
φ120h7 φ120h7
φ79 φ79 260 59.3
2 2 φ25
4-M20×P2.5 71.5 71.5 4-M20×P2.5 3-M4
D59
D60
Concentric Hollow Shaft
S-Type Reducer
(Designated Motor Attachable Type)
D61
Model and Type Designation
Type Designation
Model and
F3 S S 30 50 040
F3 S S 45 240 075 X
① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩
④Frame No. and Diameter of Output Shaft Output Shaft Diameter (Inner Diameter)
Blank:Standard Specifications
⑨Auxiliary Mark
X :Mark for Special Additional Specs
⑩Spec. Designation
Note) Spec. Designation is not shown as a
part of the product model name on the Blank : Standard Specifications
nameplate. It is shown in the Spec.
Designation column on the nameplate.
Note 1) Please note that F3 series S-Type Reducers have the F3S type (Hollow Shaft) only, and do not have the F3F type (Solid Shaft).
D62
Lineup
Standard Model
Standard Model Lineup
F3S Type (Hollow Shaft) Model Lineup
4P Motor Frame Reduction Ratio
Type Capacity Number
S-Type Reducer
1/5 1/7.5 1/10 1/12.5 1/15 1/20 1/25 1/30 1/40
35
1/50 1/60
0.75kW
45 1/80 1/100 1/120 1/160 1/200 1/240
Note The models enclosed with " " are the low torque type. Special care should be given to
the allowable torque in the performance table.
D63
D64
Concentric Hollow Shaft
S-Type Reducer
(Designated Motor Attachable Type)
Performance Table /
Dimension Diagram
F3
Series
F3S
Type
【Remarks】
●Please refer to〈page D53〉 for the output shaft rotation direction in
regard to input/output shaft rotation direction.
●The values of output shaft allowable torque indicate the values
during operation of a 4-pole motor.
●If used with motors other than a 4-pole motor, the value with the
torque correction coefficient on〈page E54〉multiplied to it is the
rotation's output shaft allowable torque.
●The key for the outout shaft is not attached to this model.
D65
Lineup
Standard Model
Concentric Hollow Shaft F3 Series (F3S Type)
Note 1) The allowable O.H.L. are the values measured at the position of 20mm from the edge of output shaft.
2) Please be sure to read the remarks stated on〈page D53〉regarding the rotation method of output shaft.
3) The models marked with * are limited torque type. Be sure to refer to the allowable torque in the performance table.
D66
Lineup
Standard Model
Equivalent of 0.75kWー2.2kW
Note 1) The allowable O.H.L. are the values measured at the position of 20mm from the edge of output shaft.
2) Please be sure to read the remarks stated on〈page D53〉regarding the rotation method of output shaft.
3) The models marked with * are limited torque type. Be sure to refer to the allowable torque in the performance table.
D67
Diagrams
Outer Dimension
Concentric Hollow Shaft F3 Series (F3S Type)
S-Type Reducer
Frame No. 20
64 64
When the protective When the protective
cap is attached. cap is attached.
92 194.5 S
7 7 8
78 127
39 39 78.5 4.5
96 Flange surface Flange surface 48.5
24 24 38.5
48 68.5
13 13 Protective cap 6
F3S-20
φ20H8 φ20H8 (attachment)
48.5 5
38.5 φ110G7
φ53h7 φ53h7 10
φ29 φ29 97 22.8 φ160
4-φ10.5 4-φ8.6 38.5
48.5 φ130
φ11H7Depth33
(Standard surface)
2 2
4-M10×P1.5 4-M10×P1.5
4-M8×P1.25
37 37 Depth11 (Penetrated)
Frame No. 25
Fig.1
79 79
When the protective When the protective 225.5
cap is attached. cap is attached. S
114 159 8
7 7 4.5
118 100 53.5 105.5
27 27 Flange surface Flange surface
64 50 50 43.5 95.5
14 14 Protective cap
F3S-25
8
Fig.2 79 79
When the protective When the protective
cap is attached. cap is attached. 207
114 140 S
7 7 8
118 100 53.5 86.5
27 27 Flange surface Flange surface 4.5
64 50 50 43.5 76.5
14 14 Protective cap
8
F3S-25
φ25H8 φ25H8 (attachment)
53.5 5
43.5 φ110G7
φ66h7 φ66h7 10
φ39 φ39 107 28.3 φ160
4-φ10.5 43.5
φ130
53.5 φ11H7Depth33
(Standard surface)
2 2
4-M10×P1.5 4-M10×P1.5
4-M8×P1.25
Depth11 (Penetrated)
39.5 39.5
D68
Diagrams
Outer Dimension
Frame No. 30
Fig.1
82 82
When the protective When the protective 246.5
cap is attached. cap is attached.
120 180
S
7 106 7 8
124 Flange surface Flange surface 58 122
33 58 33 4.5
53 53 46 110
17 17 Protective cap
F3S-30 8
(attachment)
φ30H8 φ30H8
58 5
46 φ110G7
φ75h7 φ75h7 10
φ44 φ44 116 33.3 φ160
4-φ12.5 4-φ10.6 46
φ130
58 φ11H7Depth33
(Standard surface)
2 2
4-M12×P1.75 4-M12×P1.75 4-M8×P1.25
45.5 45.5 Depth11 (Penetrated)
Fig.2 82 82
When the protective When the protective 235.5
cap is attached. cap is attached.
120 159 S
7 106 7 8
124 Flange surface Flange surface 58 101
33 58 33 4.5
53 53 48 91
17 17 Protective cap
F3S-30 8
D69
Diagrams
Outer Dimension
Concentric Hollow Shaft F3 Series (F3S Type)
S-Type Reducer
Frame No. 35
Fig.1 95 95 294
When the protective When the protective 222 S
cap is attached. cap is attached.
142 138 8
Flange surface Flange surface 68 154
38 66 38 7 124 7 4.5
54 140
20 20 Protective cap
F3S-35 62 62 10
(attachment)
φ35H8 φ35H8
68 5
54 φ110G7
φ85h7 φ85h7 16
φ49 φ49 136 38.3 φ160
4-φ16.5 54 φ130
68
φ14F7Depth36
(Standard surface)
2 2 4-M8×P1.25
4-M16×P2 4-M16×P2
58 58 Depth20
Fig.2
95 95
When the protective When the protective 265.5
cap is attached. cap is attached. 9 S
138 185
7 124 7 4.5
142 Flange surface Flange surface 68 117
38 66 38 62 62 56 105
20 20 Protective cap
F3S-35 10
(attachment)
φ35H8 φ35H8
68 6
56 φ130G7
φ85h7 φ85h7 21.5
φ49 φ49 136 38.3 φ200
4-φ12.5 4-φ10.6 56
68 φ165
φ19F7Depth42
(Standard surface)
2 2
4-M12×P1.75 48 4-M12×P1.75
48 4-M10×P1.5
Depth23 (Penetrated)
D70
Diagrams
Outer Dimension
Frame No. 45
Fig.1 108 108
350 S
When the protective When the protective 9
cap is attached. cap is attached. 272
168 164 87 4.5
185
50 50 Flange surface 7 7 Flange surface
68 150 69 167
26 26
Protective cap 75 75 14
F3S-45
φ45H8 φ45H8 (attachment) 6
87
69 φ130G7
φ100h7 φ100h7 21.5
φ64 174 48.8 φ200
φ64
4-φ20.5 4-φ17.5 69 103 φ165
87 119.5
φ19F7Depth42
(Standard surface)
2 2 φ20 4-M10×P1.5
4-M20×P2.5 73 73 4-M20×P2.5
Depth23 (Penetrated)
Fig.3
108 108
When the protective When the protective 356.5
cap is attached. cap is attached. S
164 235 16
7 150 7 5
168 87 148
50 50 Flange surface Flange surface
68 75 75 73 134
26 26 Protective cap 14
F3S-45 8
φ45H8 φ45H8 (attachment)
87
73
φ100h7 φ100h7 φ180G7 φ250
φ64 φ64 174 48.8 31
98.5 φ215
4-φ16.5 4-φ14 73
87 115
φ28F7Depth62
2 2 φ20 (Standard surface)
4-M16×P2.0 63 63 4-M16×P2.0 4-M12×P1.75
Depth16 (Penetrated)
D71
Diagrams
Outer Dimension
Concentric Hollow Shaft F3 Series (F3S Type)
S-Type Reducer
Frame No. 50
120 120 435.5
When the protective When the protective 304 S
cap is attached. cap is attached.
Flange surface Flange surface 16
172 168 118 186
55 55 7 7
62 154 102 170 5
29 29 Protective cap
F3S-5055 77 77 14
(attachment) 8
φ50H8 φ50H8 106
90
φ110h7 φ74 φ250
φ74φ110h7 212 53.8 φ180G7 31
90 121
4-φ16.5 4-φ14 φ215
106 137.3
φ28F7Depth62
2 2 φ20 (Standard surface)
4-M12×P1.75
4-M16×P2.0 4-M16×P2.0 3-M4 Depth16 (Penetrated)
59 59
The values within parentheses are of those with brake motors.
Frame No. 55
Fig.1 143 143 434.5
When the protective When the protective S
cap is attached. cap is attached. 336
12
220 Flange surface 216 Flange surface 116 220
61 61 8 8 4.5
98 200 94 198
32 32 Protective cap 100 100 16
F3S-5055
(attachment)
φ55H8 φ55H8 130 8
108 27
φ120h7 φ120h7 φ130G7 φ200
φ79 φ79 260 59.3 φ165
4-φ20.5 108 149
4-φ17.5
130 169.5
φ24F7Depth52
(Standard surface)
4-M10×P1.5
2 2 φ25 Depth25
4-M20×P2.5 71.5 71.5 4-M20×P2.5 3-M4
4-φ20.5 4-φ17.5
108 149 φ215
130 169.5
φ28F7Depth62
(Standard surface)
2 2 φ25 4-M12×P1.75
4-M20×P2.5 71.5 71.5 4-M20×P2.5 3-M4 Depth16 (Penetrated)
D72
Outer Dimension
D73
Diagrams
D74