0% found this document useful (0 votes)
114 views11 pages

Second Order Systems

1) Second order systems are described by a standard transfer function involving gain (K), natural period of oscillation (τ), and damping factor (ζ). 2) The characteristic equation determines whether a system is overdamped, critically damped, or underdamped based on the damping factor ζ. 3) For a step input, responses can be characterized by rise time, overshoot, settling time, and other parameters that depend on τ and ζ. 4) For a sinusoidal input, the output amplitude is a function of the input amplitude, frequency, τ, and ζ as described by the transfer function.

Uploaded by

Mn
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
114 views11 pages

Second Order Systems

1) Second order systems are described by a standard transfer function involving gain (K), natural period of oscillation (τ), and damping factor (ζ). 2) The characteristic equation determines whether a system is overdamped, critically damped, or underdamped based on the damping factor ζ. 3) For a step input, responses can be characterized by rise time, overshoot, settling time, and other parameters that depend on τ and ζ. 4) For a sinusoidal input, the output amplitude is a function of the input amplitude, frequency, τ, and ζ as described by the transfer function.

Uploaded by

Mn
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 11

Second Order Systems

Second Order Equations


Standard Form

G (s ) =
K K = Gain
τ 2 s 2 + 2ζτs + 1 τ = Natural Period of Oscillation
ζ = Damping Factor (zeta)

Note: this has to be 1.0!!!

Corresponding Differential Equation


d2 y dy
τ2 2 + 2ζτ + y = Kf (t)
dt dt

1
Origins of Second Order
Equations
K1 K2
1. Multiple Capacity Systems in Series
τ1s + 1 τ 2 s +1

become

K1 K 2 K
or
(τ 1s +1)(τ 2 s + 1) τ 2 s 2 + 2ζτs + 1

2. Controlled Systems (to be discussed later)


3. Inherently Second Order Systems
• Mechanical systems and some sensors
• Not that common in chemical process control

Examination of the Characteristic


Equation
τ 2 s 2 + 2ζτs + 1 = 0
ζ>1 Overdamped Two distinct real
roots
ζ=1 Critically Two equal real
Damped roots
0<ζ<1 Underdamped Two complex
conjugate roots

2
Response of 2nd Order System
to Step Inputs

Overdamped Sluggish, no oscillations


Eq. 5-48 or 5-49
Critically damped Faster than overdamped, no
Eq. 5-50 oscillation
Underdamped Fast, oscillations occur
Eq. 5-51

Ways to describe underdamped responses:


• Rise time • Time to first peak
• Settling time • Overshoot
• Decay ratio • Period of oscillation

Response of 2nd Order Systems


to Step Input ( 0 < ζ < 1)
1. Rise Time: tr is the time the process output takes to first
reach the new steady-state value.
2. Time to First Peak: tp is the time required for the
output to reach its first maximum value.
3. Settling Time: ts is defined as the time required for the
process output to reach and remain inside a band whose
width is equal to ±5% of the total change in y. The term
95% response time sometimes is used to refer to this
case. Also, values of ±1% sometimes are used.
4. Overshoot: OS = a/b (% overshoot is 100a/b).
5. Decay Ratio: DR = c/a (where c is the height of the
second peak).
6. Period of Oscillation: P is the time between two
successive peaks or two successive valleys of the
response.
Eq. 5-51
⎧⎪ ⎡ ⎛ 1−ζ 2 ⎞ ζ ⎛ 1−ζ 2 ⎞⎤ ⎫⎪
y (t ) = KM ⎨1 − e −ζt /τ ⎢cos⎜ t⎟ + sin⎜ t ⎟⎥ ⎬
⎪⎩ ⎢⎣ ⎜⎝ τ ⎟
⎠ 1−ζ 2 ⎜ τ

⎟⎥
⎠⎦ ⎪⎭

3
Response of 2nd Order Systems
to Step Input

as ζ ↓, tr ↓ and OS ↑

0<ζ<1 ζ ≥1

Note that ζ < 0 gives an unstable solution

Relationships between OS, DR, P and τ, ζ


for step input to 2nd order system,
underdamped solution Y ( s) = 2 2 KM ζ <1
s (τ s + 2ζτs + 1)
,

(5-52) πτ
tp =
1−ζ 2
(5-53 ⎛
OS = exp⎜ −
πζ ⎞
⎟ ζ =
[ln(OS ) ]
2 Above
π + [ln (OS ) ]
(5-56)
⎜ 1−ζ 2 ⎟ 2 2
⎝ ⎠
(5-54) DR = (OS )
2

⎛ 2πζ ⎞⎟
= exp⎜ −
⎜ 1 − ζ 2 ⎟⎠

(5-55) 2πτ 1−ζ 2 Above
P= τ= P (5-57)
1−ζ 2 2π
τ
(5-60)
tr = (1 − cos ζ )
−1

1−ζ 2

4
Response of 2nd Order System
to Sinusoidal Input
Output is also oscillatory
Output has a different amplitude than the input
Amplitude ratio is a function of ζ, τ
(see Eq. 5-63)
Output is phase shifted from the input
Frequency ω must be in radians/time!!!
(2π radians = 1 cycle)
P = time/cycle = 1/(ν), 2πν = ω, so P = 2π/ω
(where ν = frequency in cycles/time)

Sinusoidal Input, 2nd Order System


(Section 5.4.2)
Note log scale

• Input = A sin ωt, so


– A is the amplitude of the input function
– ω is the frequency in radians/time
• At long times (so exponential dies out),

 is the output amplitude Note: There is also an equation


for the maximum amplitude
KA ratio (5-66)
Aˆ = (5-63)
[1 − (ωτ ) ] + (2ζωτ )
2 2 2

Bottom line: We can calculate how the output amplitude changes


due to a sinusoidal input

5
Road Map for 2nd Order Equations
Standard Form

Step Sinusoidal Other Input


Response Response Functions
(long-time only) -Use partial
(5-63) fractions

Underdamped Critically Overdamped


0<ζ<1 damped ζ>1
(5-51) ζ=1 (5-48, 5-49)
(5-50)
Relationship between
OS, P, tr and ζ, τ
(pp. 119-120)

Example 5.5
• Heated tank + controller = 2nd order system
(a) When feed rate changes from 0.4 to 0.5
kg/s (step function), Ttank changes from 100
to 102°C.
Find gain (K) of transfer function:

6
Road Map for 2nd Order Equations
Standard Form

Step Sinusoidal Other Input


Response Response Functions
(long-time only) -Use partial
(5-63) fractions

Underdamped Critically Overdamped


0<ζ<1 damped ζ>1
(5-51) ζ=1 (5-48, 5-49)
(5-50)
Relationship between
OS, P, tr and ζ, τ
(pp. 119-120)

Example 5.5
• Heated tank + controller = 2nd order system
(a) When feed rate changes from 0.4 to 0.5
kg/s (step function), Ttank changes from 100
to 102°C.
Find gain (K) of transfer function:

7
Example 5.5
• Heated tank + controller = 2nd order system
(b) Response is slightly oscillatory, with first
two maxima of 102.5 and 102.0°C at 1000
and 3600 S.
What is the complete process transfer
function?

Example 5.5
• Heated tank + controller = 2nd order system
(c) Predict tr:

8
Example 5.6
• Thermowell + CSTR = 2nd order system
′ (s )
(a) Tmeas 1
= Thermocouple

′ ( s)
Treactor (3s + 1)(10s + 1)
CSTR
Find τ, ζ:

Road Map for 2nd Order Equations


Standard Form

Step Sinusoidal Other Input


Response Response Functions
(long-time only) -Use partial
(5-63) fractions

Underdamped Critically Overdamped


0<ζ<1 damped ζ>1
(5-51) ζ=1 (5-48, 5-49)
(5-50)
Relationship between
OS, P, tr and ζ, τ
(pp. 119-120)

9
Example 5.6
• Thermowell + CSTR = 2nd order system
′ (s )
(a) Tmeas 1
=
′ ( s)
Treactor (3s + 1)(10s + 1)
Find τ, ζ:

Example 5.6
• Thermowell + CSTR = 2nd order system
(b) Temperature cycles between 180 and 183°C, with
period of 30 s.
Find ω, Â:

10
Example 5.6
• Thermowell + CSTR = 2nd order system
(c) Find A (actual amplitude of reactor sine wave):

11

You might also like