User Manual Fm60 New Version
User Manual Fm60 New Version
Flexible Multiplexer
User’s Manual
New version December -12-2004
261012-013
The manual provides information about the features, functions, installation,
operation, testing and maintenance, and other useful messages of the FM-60.
The user reading this manual is presumed to have basic understandings of
telecommunications. This manual is subject to change without notice. For
product updates, new product releases, manual revisions, software upgrades, and
technical support visit Comtrend Corporation at http://www.comtrendcorp.com
Copyright
Copyright© 2001 Comtrend Corporation. All rights reserved. The content of this
manual is subject to change without notice. The information and messages
contained herein are proprietary to Comtrend Corporation. No part of this
manual may be translated, transcribed, reproduced, in any form, or by any means
without prior written permission by Comtrend Corporation.
Technical support
If your device is malfunctioning or you require technical service please send Email
to: [email protected]
Manual Organization
This manual is organized into five parts; Part I: includes a device overview and
guide for initial configuration. Part II: introduces the configurations for common
units. Part III: introduces the configurations for the voice channel units. Part IV:
introduces the configurations for the data channel units. Appendices: introduces
the pin assignments, system specifications, and cable specifications.
ii
• Chapter 3: Initial configuration
Appendices:
!" For protection against shock hazard, make sure that all power related cabling
and wiring are disconnected and removed before servicing the equipment.
iii
!" Avoid spilling liquid on the equipment.
!" Install the equipment into a rack that is secured to the building.
!" To prevent overheating of the equipment, make sure the equipment is not
operating in an ambient temperature over 50 degrees Celsius.
ESD Warning
Electrostatics Discharge (ESD) may cause severe damage to the circuit board that
you are handling. To avoid this, always wear an antistatic wrist strap or ankle
strap or any device with the same function when handling or servicing the
equipment.
iv
TABLE OF CONTENTS
v
CHAPTER 5 SYSTEM CONFIGURATION.........................................26
5.1 System Administration ........................................................ 26
5.1.1 EMCU................................................................................ 27
5.1.2 E1 Line 1+1 Protection ........................................................ 28
5.1.3 Timing Source .................................................................... 29
5.1.4 Software Download............................................................. 30
5.2 SNMP and COM Ports .......................................................... 31
5.2.1 SNMP Parameters ............................................................... 31
5.2.2 CID/Console Port Parameters ............................................... 32
5.3 Viewing Alarm Records ........................................................ 33
5.3.1 Enabling BER Alarm ............................................................ 34
5.4 Alarm Event List ................................................................. 34
5.5 Introducing the Loopbacks................................................... 35
vi
10.1.3 Reset Push Button ............................................................ 126
10.1.4 Alarm-Cut-Off Push Button ................................................ 127
10.1.5 LAN Port.......................................................................... 127
10.2 Configuration ................................................................... 128
10.2.1 Saving and Downloading Configurations .............................. 128
10.2.2 Self Test .......................................................................... 129
vii
16.1 Application....................................................................... 156
16.2 Faceplate......................................................................... 157
16.3 Configuration ................................................................... 158
16.4 Maintenance .................................................................... 159
viii
21.6 Remote Control over the CT-210 MSDSL NTU....................... 200
21.6.1 Saving Configurations to the CT-210 ................................... 200
21.6.2 Loopback Test to the CT-210.............................................. 201
ix
LIST OF FIGURES
Figure 1-1 Application ............................................................................... 5
Figure 2-1 Rear Panel of FM-60 Chassis ....................................................... 6
Figure 2-2 Power Supply Connectors ........................................................... 7
Figure 2-3 Office Alarm Connectors............................................................. 7
Figure 2-4 CID Flow Control DIP Switch....................................................... 8
Figure 2-5 Console Port DIP Switch............................................................. 8
Figure 2-6 E1 Interface ............................................................................. 9
Figure 2-7 External Clock Connectors ........................................................ 10
Figure 2-8 GND/FG Short-circuit Connectors .............................................. 10
Figure 2-9 Operations of the Units ............................................................ 11
Figure 3-1 Console Connection ................................................................. 14
Figure 3-2 LAN Connection ...................................................................... 17
Figure 4-1 FM-60 CID Main Menu ............................................................. 23
Figure 5-1 Administration ........................................................................ 26
Figure 5-2 E1 1+1 Protection ................................................................... 29
Figure 5-3 Software Download Window ..................................................... 30
Figure 5-4 Setting SNMP and COM Port Parameters .................................... 31
Figure 5-5 Viewing Alarm Records ............................................................ 33
Figure 5-6 Alarm Event List ..................................................................... 34
Figure 5-7 E1 Local loopback ................................................................... 35
Figure 5-8 E1 Line Loopback .................................................................... 36
Figure 5-9 E1 Payload loopback ................................................................ 36
Figure 5-10 Channel Loopback to E1 Line .................................................. 36
Figure 5-11 Channel Unit Loopback To user ............................................... 37
Figure 6-1 E1 Performance by Quarter and Day.......................................... 39
Figure 6-2 Collecting Performance Statistics According to Item..................... 40
Figure 6-3 Setting the Thresholds............................................................. 41
Figure 7-1 TSI Configuration Main Screen .................................................. 45
Figure 7-2 Time Slot Selections ................................................................ 46
Figure 8-1 FM-60 In-band Management A.................................................. 51
Figure 8-2 FM-60 In-band Management B.................................................. 51
Figure 8-3 FM-60 In-band Management C.................................................. 52
x
Figure 8-4 In-band Management Between Two FM-60s Via E1 ...................... 57
Figure 8-5 In-band Management Between Two FM-60s Across DCS............... 57
Figure 8-6 Two FM-60 Connection Diagram ................................................ 58
Figure 8-7 In-band Management of FM-60s in Multi-Grade........................... 67
Figure 8-8 In-band Management of Multi-Grade with multiple ENRS.............. 68
Figure 8-9 Multi-Grade In-band Management with a single ENRS.................. 87
Figure 8-10 In-band Management via E1 to LAN....................................... 105
Figure 9-1 EPSU Faceplate ..................................................................... 123
Figure 10-1 EMCU-B Faceplate ............................................................... 125
Figure 10-2 EMCU Configuration Screen .................................................. 128
Figure 11-1 ELIU Faceplate .................................................................... 130
Figure 11-2 Jumpers on the ELIU/ELIU2 .................................................. 131
Figure 11-3 ELIU Configuration Screen .................................................... 132
Figure 11-4 Maintenance of ELIU ............................................................ 133
Figure 12-1 ENRS Faceplate ................................................................... 134
Figure 12-2 ENRS Configuration ............................................................. 135
Figure 13-1 Application of the Voice Units ................................................ 138
Figure 13-2 EE&M Faceplate................................................................... 139
Figure 13-3 EEM2 Faceplate ................................................................... 140
Figure 13-4 EEM4 Faceplate ................................................................... 141
Figure 13-5 EEM2 DIP Switches.............................................................. 142
Figure 13-6 EE&M Configuration Screen .................................................. 143
Figure 13-7 EE&M Maintenance Screen.................................................... 144
Figure 14-1 Application of the ELTU ........................................................ 146
Figure 14-2 ELTU Faceplate.................................................................... 147
Figure 14-3 ELTU Configuration Screen.................................................... 148
Figure 14-4 Maintenance of ELTU............................................................ 149
Figure 15-1 POTS Extension Service ....................................................... 150
Figure 15-2 EFXO-8 Port Faceplate.......................................................... 151
Figure 15-3 Faceplate Status of the EFXO-8P and EFXS-8P ........................ 152
Figure 15-4 Configuration of the EFXO-8P and EFXS-8P............................. 153
Figure 15-5 Maintenance Screen ............................................................ 154
Figure 16-1 Application of EE0U ............................................................. 156
Figure 16-2 EE0U Faceplate ................................................................... 157
Figure 16-3 EE0U Configuration Screen ................................................... 158
xi
Figure 16-4 EE0U Maintenance Screen .................................................... 159
Figure 17-1 Application of EBRI .............................................................. 160
Figure 17-2 EBRI Faceplate.................................................................... 161
Figure 17-3 EBRI Configuration Screen.................................................... 162
Figure 17-4 EBRI Maintenance Screen..................................................... 164
Figure 17-5 EOC of EBRI ....................................................................... 165
Figure 17-6 Performance of EBRI............................................................ 167
Figure 18-1 Application of EBCU ............................................................. 169
Figure 18-2 EBCU Faceplate ................................................................... 170
Figure 18-3 EBCU Configuration Menu ..................................................... 171
Figure 18-4 Maintenance of EBCU ........................................................... 173
Figure 18-5 EOC to CPE......................................................................... 174
Figure 18-6 Performance ....................................................................... 176
Figure 18-7 Remote Configuring CT-128.................................................. 178
Figure 18-8 X.50 Configuration Panel ...................................................... 180
Figure 18-9 B1 Channel......................................................................... 181
Figure 18-10 DS0A Configuration Panel ................................................... 182
Figure 19-1 Application of EDSU ............................................................. 183
Figure 19-2 EDSU Faceplate................................................................... 184
Figure 19-3 EDSU Configuration Screen................................................... 185
Figure 19-4 EDSU Maintenance Screen.................................................... 186
Figure 20-1 ESUB Application................................................................. 188
Figure 20-2 ESUB Faceplate ................................................................... 189
Figure 20-3 ESUB Configuration Panel ..................................................... 190
Figure 20-4 X.50 Configuration Panel ...................................................... 191
Figure 20-5 EDSU B1 Channel ................................................................ 192
Figure 20-6 DS0A Configuration Panel..................................................... 193
Figure 20-7 ESUB Maintenance Screen .................................................... 194
Figure 21-1 EMSU Application ................................................................ 195
Figure 21-2 EMSU Faceplate .................................................................. 196
Figure 21-3 EMSU Configuration Screen .................................................. 197
Figure 21-4 EMSU Maintenance Screen ................................................... 198
Figure 21-5 EMSU Performance Screen ................................................... 199
Figure 21-6 Save VCDB to the Remote CT-210 Flash................................. 200
Figure 21-7 EMSU Loopbacks ................................................................. 201
xii
Figure 22-1 ELAN Application ................................................................. 203
Figure 22-2 ELAN Faceplate ................................................................... 204
Figure 22-3 ELAN Configuration Menu ..................................................... 205
Figure 22-4 ELAN: Bridge Mode- Port Configuration .................................. 206
Figure 22-5 ELAN: Bridge Mode- Common Configurations .......................... 208
Figure 22-6 ELAN: Bridge Mode- LAN Interface ........................................ 208
Figure 22-7 ELAN: Bridge Mode- Static MAC Entry .................................... 209
Figure 22-8 ELAN: Bridge Mode-Spanning Tree Protocol ............................ 210
Figure 22-9 Router Mode ....................................................................... 211
Figure 22-10 ELAN: Router Mode-LAN Interface ....................................... 211
Figure 22-11 ELAN: Router Mode- Routing Table....................................... 212
Figure 22-12 ELAN: Router- Port Configuration......................................... 213
Figure 23-1 EATU Application 1 .............................................................. 217
Figure 23-2 EATU Application 2 .............................................................. 217
Figure 23-3 EATU Faceplate ................................................................... 219
Figure 23-4 EATU Configuration.............................................................. 221
Figure 23-5 EATU Maintenance ............................................................... 223
Figure 23-6 EATU Performance ............................................................... 224
xiii
LIST OF TABLES
Table 5-1 CID and COM Port Setup ........................................................... 32
Table 6-1 Default of the E1 Thresholds ...................................................... 41
Table 7-1 TSI Configurations between/among channel units......................... 43
Table 7-2 Different States of Time Slots..................................................... 47
Table 11-1 ELIU/ELIU2 Jumper Settings .................................................. 131
Table 13-1 EEM2 DIP Switch Settings ...................................................... 142
Table 13-2 Wire Type Parameters............................................................ 143
Table 17-1 EBRI Configuration Parameters ............................................... 163
Table 18-1 EBCU Configuration Parameters .............................................. 172
Table 22-1 ELAN Port MAP Setup ............................................................ 210
xiv
Part I: Getting Started
Part I provides an overview of the FM-60, including its features, and applications.
Then, it provides information for hardware installation, initial configuration of the
device and basic configuration of the device.
1
Chapter 1 Introduction
The FM-60 is a flexible transmission system, which provides voice and data
applications by time division multiplexing and de-multiplexing on 2.048 Mbps E1
signals. Timeslot interchange (TSI) technique is applied to provide timeslot
assignment and timeslot interchange capability, so that any 64 Kbps or Nx64 Kbps
user signals can be assigned and cross-connected to any E1 timeslot(s).
The FM-60 has a compact design. It is equipped with 18 slots for various units.
Three of them are for common units, and the remaining fifteen slots are for
channel units. The channel units provide versatile user services. All the channel
units are hot-swappable, and different types of channel units can be placed in the
FM-60 simultaneously with arbitrary combination.
Featured with a built-in SNMP agent, the FM-60 supports network management
for operation, administration, maintenance, and provision. It can be managed
through user-friendly GUI management software. FM-60 is equipped with two
RS-232 ports and one Ethernet port for management. Moreover, the FM-60
supports remote management capability, which allows it to be managed over
in-band E1 timeslot. Accompanied with the static routing function, management
messages can be routed from one FM-60 to next FM-60 over E1 line, so that the
remote management capability can be greatly extended.
The FM-60 also provides the function of remote control with CT-128 Multiple-Rate
NTU and CT-50 Subrate NTU. When the CT-128 or the CT-50 is connected to the
FM-60, it can be remotely controlled by the network management system.
2
1.1 Features
!" Installed in standard 19 inch rack
!" E1 network interface with 2 or 4 E1 lines
!" E1 network interface meets G.703 specifications
!" 15 channel units for customer applications
!" Versatile user services include: 2W/4W E&M, Loop termination, FXO/FXS,
ISDN BRITE, IDSL (128 Kbps baseband transmission), G.703 64Kbps
co-directional, V.35 Nx64Kbps, V.24 subrate, MSDSL, LAN extension, ADSL
!" Timeslot interchange (TSI) functionality
!" Arbitrary timeslot assignment from tributary signals to E1 lines
!" Cross connection between tributary signals and between E1 lines
!" Firmware downloading
!" Configuration data storage in non-volatile memory
!" Ethernet interface for centralized control
!" 1+1 protection switch for E1 lines
!" Timing source: Loop, external, and internal
!" Test unit for analog and digital tests
!" Power unit redundancy to guarantee system reliability
!" GUI management software
!" SNMP management
!" Remote management over in-band E1 timeslot
!" Remote control with CT-128 Multiple Rate NTU and CT-50 Subrate NTU
3
1.2 System Diagram
The FM-60 consists of customer interface units (channel units), one E1 line
interface unit (ELIU or ELIU2), one maintenance and control unit (EMCU-B), and
two power supply units (EPSU).
The digital or analog user signals from the customer loops are terminated by
channel units (CU), and are then transmitted to the EMCU-B. Time slot
interchange for transmitting the CU data to the desired E1 time slots or to other
CU locations is performed inside the EMCU-B by the time slot interchange (TSI).
Interchanged data is sent to the ELIU/ELIU2 for transmitting data to the
corresponding time slots on E1 lines.
The FM-60 timing sources can be generated from a 2.048 MHz external clock,
received E1 lines, and internal oscillator. The EMCU-B selects one of these clock
sources and connects it to the phase lock loop (PLL) inside EMCU-B to derive
system synchronization clocks of FM-60. The EMCU-B also generates a 2.048
MHz output clock.
4
1.3 System Application
The FM-60 can be applied to various applications using different channel units.
The following diagram displays those applications. For specific application of a
channel unit, refer to the following chapters that describe each unit individually.
5
Chapter 2 Installation
2.1 Chassis
The FM-60 is mounted on a standard 19-inch rack and it provides 18 slots. The
dimensions of the chassis are 432mm (H) x 256mm (W) x 300mm (D).
6
Power Supply Connector
The FM-60 is operated on a -48 VDC power source with tolerance of -42 volts to
-56 volts. Two -48V terminal blocks: JDU1 and JDU2, are provided on the rear
panel. The maintenance personnel can connect the power source to either or
both of the terminal blocks. Each terminal block has three pins.
There are two office alarm wire strap pins on the rear panel: audible and visible
alarm, each with three pins. The pin assignments are listed below:
!" NC: If a normally close signal is required, connect the alarm wire to the COM
pin and NC pin. In normal state, the NC and COM are short-circuited. If an
alarm occurs, NC and COM are open-circuited.
7
!" NO: If a normally open signal is required, connect the alarm wire to the COM
pin and NO pin. In normal state, the NO and COM are open-circuited. If an
alarm occurs, NO and COM are short-circuited.
There are four small switches on the CID port DIP Switch. The default settings
are off (disable), 38.4 Kbps, and flow control disabled. This switch is used to set
the CID port parameters.
DIP Switch Switch No. Position Function
SW 1 / SW 2 ON / ON The CID port rate is
configured by the FM-60
CID software.
ON/ OFF Rate = 9.6Kbps
OFF/ON Rate = 19.2Kbps
OFF/OFF Rate = 38.4Kbps
SW3/ SW4 - Reserved
There are four switches on the Console port DIP switch. The default settings are
off (disable), 38.4 Kbps, and flow control disabled. This switch is used to set the
Console port parameters.
DIP Switch Switch No. Position Function
The Console port rate is
ON / ON configured by the FM-60
CID software.
SW 1 / SW 2
OFF/ON Rate = 19.2 Kbps
OFF/OFF Rate = 38.4 Kbps
ON/OFF Reserved
ON Flow Control Enable
SW3
OFF Flow Control Disable
SW4 - Reserved
8
E1 Connectors
There are two types of E1 connectors: BNC of 75 ohms impedance and wire strap
pin of 120 ohms impedance.
BNC connector
FM-60 provides two types of line interface unit for purchase option.
9
External Clock Connectors
A device can use the FM-60 clock via the connection to the EXT_CLK (O) connector.
The output clock is a 120 ohms symmetrical 2.048 MHz square wave, which meets
ITU-T G.703.
The GND and FG Pins are located at the bottom right side of the rear panel.
There is a short-circuiting plate between the GND and FG. This is default
assembly.
10
2.2 Common Units
This section introduces the components and installation of common units in FM-60
and it describes detail information of the EPSU. For detailed information on the
EMCU-B and ELIU/ELIU2, refer to the following chapters.
2.2.1 Introduction
The common units are fundamental elements in a FM-60. They are in charge of
power source, data processing, test and maintenance, configuration and
operation of the channel units.
When you face the chassis, the common units are on your left side and are labeled
EPSU, EMCU and ELIU in sequence.
11
2.2.2 Installation
Before installation, make sure no card resides in the chassis. Then, do as follows.
STEP 1 Connect the power source to either JDU1 and JDU2 or both.
STEP 2 Insert the EPSU in either of the EPSU slots. Fasten the unit in the
slot with the locking handles at both ends on the faceplate.
STEP 3 Measure the jacks on the EPSU faceplate and estimate if the power is
correctly supplied to the channel units.
STEP 4 Adjust the CID and Console DIP switches on the rear panel to a
desired data rate. An alternative is to do this after the EMCU-B is
inserted, but then also reset the EMCU-B (push the faceplate Reset
button). During the reset process, the traffic on the channel units
will be interrupted.
STEP 5 Insert the EMCU-B into the EMCU slot. Fasten the unit in the slot
with the locking handles at both ends on the faceplate.
STEP 6 Install the ELIU/ELIU2. Before sliding the card into the ELIU slot,
first select an E1 interface (BNC or wire strap pins) using the onboard
jumpers. The jumper setting is introduced in the later chapter of
ELIU/ELIU2. Use the locking handles at both ends on the faceplate
to fasten the unit.
STEP 7 Connect to the E1 connectors. Note that ELIU2 can connect 1st E1
and 2nd only.
STEP 8 To use an external clock, connect the external clock wire to the
Ext_CLK (I) connector.
STEP 9 To output the FM-60 clock, connect the Ext_CLK (O) connector.
12
2.3 Channel Units
2.3.1 Introduction
Channel units can be positioned in slot 1 to slot 15. On each channel unit’s
faceplate, DB-9 or DB-25 connectors are provided to connect to customer end and
screws and locking handles are provided on the faceplate for fasten purpose.
When you face the chassis, the channel units are on your left side and are labeled
slot 1 to slot 15 respectively. Each channel unit is equipped with locking handles
at both ends on the faceplate for fasten purpose.
2.3.2 Installation
Each channel unit has the same installation procedures. The chassis (including
power) and common units should be installed prior to the channel units.
STEP 1 Verify if any hardware jumper or DIP switch should be set. Few
channel units, e.g., EEM2 has jumpers to set.
STEP 2 Slide a channel unit in an available slot (Slot 1 to Slot 15). Make sure
it fits into the backplane connector. Do not mis-put it into a
common unit slot.
STEP 3 Press the locking handles at both ends to fasten the unit into the slot.
13
Chapter 3 Initial Setup
Initial setup is performed via the console port. Its major purpose is to set the IP
address of the FM-60 that enables the user to login to the system via the LAN port.
The default IP address is 172 168.2.1.
Note: Make sure your console PC is installed with standard VT-100 emulation
program, like Telix or HyperTerminal Edition 5.
14
Note: for the cross-over cable pin assignment, refer to Appendices.
STEP 4 Enter the FM-60 IP address by typing these at the command prompt.
STEP 5 Press the Enter key. The system will inform “To use new IP address,
you must reset FM-60 system.”
STEP 6 To reset the system, enter sys rst command to reset the system.
>sys rst
15
3.2 Using the CID Port for Dialup Access
The FM-60 can be accessed via a null modem or normal modem. For this access,
you need the CID port IP address to connect your PC and the MCID, the Network
Manager. The default CID port IP address is 192.168.1.10. It can be modified
from the FM-60 CID menu: [System] > [Administration] > [CID Port IP].
STEP 2 The CID port baud rate is pre-set to 38.4 Kbps with software control
disabled at the factory.
STEP 3 To change the baud rate or enable the software control function, adjust
the CID DIP switch at the rear panel of the chassis.
STEP 6 Use the Dialup Networking to add a new session and set up the
parameters that are necessary to connect to the FM-60. After the
connection is established, a session icon will be created on the Dialup
Networking folder.
STEP 8 You will be prompted to enter the user name and password. Skip the
user name and password.
STEP 9 After establishing the session, start the MCID. The MCID software
startup is introduced in Chapter 4.
STEP 10 When you start the MCID, you will need an IP address for the FM-60.
You can use the default IP address (only for CID port), 192.168.1.10, if
it was not changed.
16
3.3 Using the LAN port
STEP 2 Start the MCID. When you start the MCID, you will need an IP address
for the FM-60. You can use the default IP address (only for LAN port),
172.168.2.1, if it was not changed.
17
Chapter 4 MCID Startup
The MCID software provides a Graphical User Interface (GUI), which can be used
to configure, maintain, and operate an FM-60 across Ethernet. You can use the
LAN port or CID port to access the MCID and configure the device.
To install the MCID, your workstation should meet the following minimum
requirements:
18
4.2 MCID Installation
STEP 1: Insert the compact disk with the FM-60 MCID software into your
workstation’s CD-ROM drive.
STEP 2: Unzip the file on the compact disk and run Setup.exe. A welcome
screen will display.
19
STEP 3: Click Next to start the installation.
STEP 4: You can click Next to install the software to the defaulted folder or click
the Browse button to select a different folder, and click Next to continue.
20
STEP 5: When an installation complete screen appears, click Finish to complete
the installation.
STEP 6: A shortcut icon of the FM-60 MCID will be established on your desktop as
shown below.
4.3 Login
STEP 1: Use a cross-over RJ45 LAN cable to connect the MCID terminal to the LAN
port on the EMCU of the FM-60.
STEP 2: Double click the MCID icon on the desktop to display the login menu.
Enter the following information of the FM-60. The default values are
also listed below. Use the default settings to login if they were not
changed.
21
STEP 3: Click Start CID to enter the main screen of the device.
22
4.4 CID Main Menu
The FM-60 main menu is shown below. From this screen, you can view the System
Configuration, Performance, and Timeslot Interchange (TSI).
At the top-left of this window are four buttons: System, Performance, TSI and
Alarm Cut Off (ACO). Below the buttons is a list of all the slots of the FM-60. To the
right is a graphical display of all the slots and their respective units.
The IP address of the operated FM-60 displays on the top of the CID screen.
23
4.4.1 Buttons
The Alarm Cut Off (ACO) button, , is located below the TSI button. It is
used to stop the audio alarm physically connected to the FM-60.
4.4.3 Indicators
! Green The green indicator always lights when the CID is in its normal
state, or it lights when a command is successfully accomplished.
! Red The red indicator lights when the command that you performed
fails.
24
4.4.4 Slot Status Colors
On the screen bottom, several colors display to verify the slot state. Under the
color, simple key words are given.
!" Config. Match: the card installed matches the type that it is configured.
!" Config. Mismatch: the card installed does not match the type that it is
configured.
!" Unconfig.Occupied: the slot is not configured but the card is inserted.
25
Chapter 5 System Configuration
On the FM-60 CID main menu, click System on the top left to access the System
menu. The menu includes the following sub-menus. To exit the menu, click
Exit.
!" EMCU
26
5.1.1 EMCU
The EMCU panel displays information of the MIB version, software version, and
the release date for reference, and it performs the following functions:
The CID port IP address is used for dial-up access. To change the IP address of
the CID port, type an IP address and mask in the [CID Port] IP field and the
[Subnet Mask] field.
To use the new IP address, click the System Restart button on the top right, or
push the Reset button on the EMCU-B faceplate.
27
Signalling Bit
The signaling bits are used for voice application. You can choose the desired
signalling bits for time slot 16 on each E1.
STEP 1: Use the scroll bar to scroll and select a signalling type. There are 16
choices from unused to ABCD.
The four E1 lines are divided into 2 pairs: 1st E1 & 2nd E1 (1&2) and 3rd E1 & 4th E1
(3&4).
STEP 5: Click the set 1&2 or set 3&4 button to apply the settings.
28
The following table explains 1+1 protection in detail.
Item Description Value
1&2, 3&4 Pair of E1 line ELIU: 1&2,
3&4
ELIU2: 1& 2
Threshold This is the Bit Error Rate (BER) to identify the E1 line 1.0E-1(10-1) ~
performance/status. 1.0E-7(10-7)
Active E1 This is the master E1 line via which data will be 1~2 or 3~4
Line received or transmitted. The other is the slave line
used for backup purpose.
For example, you select 1st E1 as the active line. The
nd
2 E1 will be the slave.
Lock-in The lock-in number is the switchable times between 1 ~ 15
number active and slave E1 lines.
If the BER of the active E1 line exceeds the threshold,
the slave line will be activated. The active E1 will be
used again when it returns to normal (BER below the
threshold). This cycle is called a switchable time.
When the lock-in number is reached, the system will
fix on the slave E1 line and no switch will be processed.
At the timing source panel, the Working Timing Source field displays the
current timing source that is used by the FM-60. To change the timing source, do
as follows.
STEP 1: Alternatively, you can make E1 line an option among the timing sources
by selecting an E1 line to be the RCLK1 in the [RCLK1] field, and selecting
the other E1 line to be the RCLK2 in the [RCLK2] field.
STEP 2: In the [First Priority] field, select an item (Internal, External, RTLK1, or
RCLK2). This field specifies the prior timing source that will be applied
to the FM-60.
STEP 3: In the [Second Priority] field, select an item. This field specifies the
second timing source. The second source will be activated immediately
29
when the prior timing source fails or becomes unavailable.
You can do the software download via a TFTP server using the EMCU-B LAN port.
To perform it, click the SW Download button on the Administration screen to enter
the software download window as shown below.
In the window, enter the IP address of the TFTP server and the download file name,
and then select the module you would like to upgrade. Finally, click the Download
button to perform the software upgrade.
Note 1: Software Download cannot be performed via the CID COM port because
the rate is too slow to download the file.
Note 2: When the download is proceeding, the EMCU faceplate on the CID main
menu will appear blue.
30
5.2 SNMP and COM Ports
To configure the SNMP and COM port parameters, select [SYSTEM] > [SNMP/COM
Ports] to display the following screen.
The SNMP & COM Ports Parameters screen includes the following sub-panels:
Trap
!" Trap IP Address: This IP address will receive the alarm traps issued by the
device.
31
Community string
By default, the baud rates of Console port and CID port that are configured by the
CID cannot be effective since it is hardware adaptive only. To enable the
software control function, the DIP switches on the rear panel of the chassis should
be set to a correct position.
To configure the COM port parameters, use the scroll bar in each field to select an
appropriate parameter.
32
5.3 Viewing Alarm Records
You can view the alarm records for inspection and trouble analysis. Up to 100
alarm occurrences can be recorded. For all the alarm events, refer to
Appendices.
STEP 1: Click the Refresh button to retrieve or refresh the alarm record. Once
you have paused on this screen for a certain period of time, you can click
this button again to refresh the screen and see if there is any new alarm
that might just happen.
STEP 2: Click the Clear Alarm Record button to delete all the alarms.
33
5.3.1 Enabling BER Alarm
E1 line bit error rate over 10-3 bps can be set as an alarm event for each E1.
STEP 1: Tick an E1 line. To de-select, tick it again to make the check mark
disappear.
You can enable or disable the individual alarm events. The enabled alarm events
will be reported when it occurs. The alarm events are listed on the
[System]>[Alarm Event] screen.
STEP 1: To select an alarm event, tick the item, or click Select All Events to
select all the items. Also tick Alarm Enabled. The selected alarm
events will be reported when they occur.
STEP 2: To deselect the item, tick the item again to make the check mark
disappear, or click the Unselect All Events button.
Note: For the complete list of the alarm events, refer to Appendices.
34
5.5 Introducing the Loopbacks
In the telecom field, a loopback is a technique to return the signal for isolating a
problem. When performing a loopback test, the signal sent to a destination that is
returned as received to the originator. This may help diagnose a problem.
This section describes the loopback tests that are used in the FM-60. There are E1
Local loopback, E1 Line loopback, E1 Payload loopback, To Line loopback and To
User loopback. Each loopback is demonstrated below.
E1 Local loopback:
35
E1 Line loopback:
E1 Payload loopback:
To Line loopback:
36
To User loopback:
37
Chapter 6 E1 Performance Monitoring
On the FM-60 CID main menu, click Performance on the top left to access the
Performance menu. The menu includes the following sub-menus. To exit the
menu, click Exit.
The E1 line performance and status are monitored and collected from the near
end and far end E1 interfaces. The E1 statistics parameters are listed below.
38
6.1 Performance Collected According to Time
The screen collects the line performance based on Quarter and Day. Up to 7-day
or 96 -quarter performances can be recorded. You can also print the results by
clicking the Print button.
STEP 1: Click an E1 line (E1-1, E1-2, E1-3, E1-4) on the left side.
39
STEP 2: Tick Quarter or Day.
The screen collects the line performance according to item at the near end or far
end. You can also print the results by clicking the Print button.
40
6.3 Setting E1 Performance Thresholds
You can set the E1 thresholds for each E1 line. Click Performance> Threshold
to access the Threshold screen.
STEP 1: Select an E1 line by clicking E1-1, E1-2, E1-3, or E1-4. The default
thresholds displays as follows.
Item Near Threshold Far Threshold
Quarter Day Quarter Day
LCV 65535 None
PCV 65535 65535
ES 900 900
SES 900 900
SES 900 900
SEFS 900 900
UAS 900 900
CSS 900 900
DM 15 15
Control Slip 900 900
41
STEP 2: Place the cursor in the item’s column, and type a new value that you
need.
42
Chapter 7 Time Slot Interchange
On the FM-60 CID main menu, click TSI on the top left to access the TSI
configuration menu. Before you start to set the TSI, the line interface unit and
channel units should be installed and configured.
The following table lists possible TSI connections between or among channel units.
For example, if an EBRI will be connected to another EBRI. Both units should
have the same port configuration (their B1 channel, B2 channel or both channels
are enabled).
!" For EBCU-EBCU connection, both EBCU should be of the same rate.
!" For EBCU-EDSU connection, both units should be of the same rate (64 or 128
kbps). For 64kbps, EBCU should use B1.
43
!" For the EDSU-EDSU connection, both EDSU should be of the same rate.
!" For the EBRI-EBRI connection, both EBRI should be of the same
configuration.
Before you start to read the chapter, be familiar with the following terms that will
help to understand this chapter.
!" Source Time Slot: It is the source of data. A Source TS can transmit data
to numerous destinations (also called Destination Time Slot).
!" Destination Time Slot: It is the destination of the data sent by the Source
Time Slot. A Destination Time Slot can be assigned to only one Source Time
Slot. Many Destination TS may share one Source TS.
!" Bi-direction: Normally, data is sent from the Source TS to one or more
Destination TS, which is one-way only. You can also assign a Destination TS
to be bi-directional. That is, in addition to one-way transmission, data can
be sent from the Destination TS to the Source TS. But, only the Destination
TS can be assigned to be bi-directional.
44
7.1 Setting TSI
This section specifies the general procedure to setting the TSI. All the units have
very similar procedures on TSI configuration.
Select TSI from the CID main screen to access the TSI main screen. The screen
displays all the available time slots. The upper part lists the channel units’ time
slots. The bottom two or four rows list the E1 time slots. (ELIU has four E1 lines,
and ELIU2 has two E1 lines.) Each E1 has 31 time slots, and TS16 may be
configured for CAS function.
45
STEP 1: The status of time slots can be identified by specific colors listed below.
STEP 2: Select a blue time slot as the Source TS. The selected time slot (also
called source time slot) will turn pink.
STEP 3: Click the Enter TSI button to select the Destination time slots.
STEP 3: The screen displays all effective Destination TS that can react with the
Source TS. For example, an EE&M TS is selected as Source TS. EE&M
is a voice unit, so the TSI selection screen displays all the available TS on
the voice channel units, like EE&M, EEM2, and EEM4. Those that are not
configured or are not the same type will appear gray.
STEP 4: On the screen, the Source TS appears pink, and the effective Destination
TS appears blue. Each TS is divided to two blocks: input and output.
46
I - Input of data.
O- Output of data.
The status or configuration of a TS can be verified according to its
colors.
White input and output- this TS is available for TSI configuration.
Blue input and white output- this is a destination TS that receives
data from source TS only.
Yellow output and blue input- this is a source TS for bi-direction
transmission.
White input and gray output- this TS is already configured for TSI.
Blue input and yellow output- it means this is a destination TS
used for bi-direction transmission.
White input and blue output- this is a destination TS for one way
transmission.
STEP 8: Click the Set TSI button. A dialog box displays informing the setup is
successful.
STEP 10: Click the Back button to return to the TSI configuration screen.
STEP 11: You may learn that all the configured TS are green.
Note: Only one destination time slot can be set to bi-directional used together
with the source time slot for mutual data transfer. Simultaneously, more
than one destination time slots can be used for one-way data flow. Those
destination time slots receive data from the source TS.
47
Chapter 8 Inband Management
The ENRS supports inband management. With an ENRS installed in the local
FM-60, other FM-60s connected to it via E1 can be configured with time slots used
for the inband management.
IMPORTANT NOTICE:
!" To configure the FM-60s via in-band connection, make sure the clocks of the
devices are synchronized.
!" In subsequent explanations and examples, where the term EMCU is used,
this means the MCU-B.
48
8.1 In-band Management via EMCU-B
The EMCU-B has two HDLC controllers. Each HDLC controller supports
management of ten FM-60s. Two HDLC controllers can be used to manage
twenty FM-60s. When the EMCU-B is used for in-band management, only two
E1s (if four are available) at most can be configured for the in-band connection.
STEP 1: Enter the FM-60 CID. On the main menu, click the EMCU-B faceplate to
enter the EMCU-B configuration screen.
49
STEP 3: Click the button, HDLC IP Address to display the screen below.
STEP 4: Enter the IP address of the remote FM-60. Up to ten IP addresses can
be added in the table. You can delete an IP address by highlighting it,
and clicking the Delete button.
STEP 5: In the [HDLC TSI] field, click a blue time slot that will be used for the
in-band management. This time slot is used to connect to the remote
FM-60.
Note: Only two E1 lines can be used for the in-band management.
50
8.2 In-band Management via ENRS
51
Figure 8-3 FM-60 In-band Management C
STEP 1: Use a cross-over RJ45 cable to connect the EMCU-B to the MCID-based
PC.
52
STEP 2: Start the MCID and open the ENRS CID screen.
STEP 3: Click a port (1 to 32) in the [Port Select] field to select an HDLC controller.
A row named ENRS below the number list displays the status of each
controller. Red means the port is selected; green means the port is
configured; grey means the port is unconfigured.
Note: The ENRS row is read-only. It displays the state of the selected HDLC
controller: selected, configured, or unconfigured. If you attempt to click a
number on the row, this message displays to tell you that it is
unconfigurable: ENRS is read-only! Please Select E1 Time Slot!
53
STEP 4: Click the IP Address… button to display the screen below to assign the
IP address of the EMCU-B.
STEP 5: On the screen, type the IP address of the EMCU-B. Click the Add button
to add the entry.
STEP 7: Click Local to make it appear red. Thus, the ENRS is able to be
configured for the in-band management.
54
STEP 9: Disconnect the PC’s connection to the EMCU-B and connect the PC to the
ENRS with a cross-over RJ45 cable.
55
STEP 10: Enter the IP address and subnet of the remote FM-60, or you can enter
a network segment. The MCID can detect those FM-60s on the same
network segment. Up to 32 network segments can be added in the
table.
STEP 11: In the [HDLC TSI] field, click a blue time slot that will be used for the
in-band management.
56
8.3 In-band Management Between Two FM-60s
The following diagram shows an application in which the central site has an FM-60
and a PC running the MCID. The FM-60 in the central site is directly connected to
three FM-60s via E1.
In this example, the FM-60 in the central site requires an EMCU-B and an ENRS.
The remote FM-60 only requires an EMCU-B. An FM-60 can mount up to three
ENRS units and can ideally manage up to hundreds of FM-60s.
57
8.3.1 Collecting In-band Management Parameters
To configure the in-band management over two nodes, collect the following
information.
!" The port number of the HDLC (1-32) used to control the remote and local
FM-60, and the number of E1 lines and time slots used to connect to the
remote FM-60.
!" The number of the HDLC port (1-2): Each EMCU-B provides two HDLC
controllers. Each controller can be selected and used to connect to the
FM-60 in the central site.
!" The number of E1 lines and time slots used to connect to the FM-60 in the
central site.
58
Setting up the FM-60 in the central site
!" HDLC TSI: 2nd E1/TS6 (used to connect the remote FM-60)
STEP 1: Use the Console port to set up the Ethernet IP (LAN port) address of the
EMCU-B. (Note: The console cable is a DB9 null modem cable.) In this
example, set the IP address to 172.16.7.21 (The value of the subnet
mask uses the factory default). The console commands are listed as
follows:
>sys ip 172 16 7 21
>sys rst
59
STEP 2: Connect the EMCU-B LAN port to the PC running the MCID. In this
example, set the IP address of the PC to 172.16.7.20/16 (should be
located in the same subnet as the FM-60).
STEP 3: Run the MCID on the PC and enter the ENRS configuration menu.
60
STEP 4: Select a port in the [Port Select] field for the local FM-60 connection. In
this example, select Port 1. The selected port turns red in the ENRS
field.
STEP 5: Click the IP address… button to enter the IP address of the local FM-60.
In this example, type 172.16.7.21. Click the Add button to add the IP
address to the address pool. The pop-up screen is shown below. Then
click Close.
61
STEP 6: Click the Local icon on the ERNS Configuration screen shown below to
make an internal connection for the local FM-60, and then click the Set
HDLC TSI button:
STEP 7: Select a port in the [Port Select] field for the remote FM-60 connection.
In this example, select Port 2. The selected port turns red in the [ENRS]
field.
62
STEP 8: Click the IP address… button to enter the IP address of the remote
FM-60. In this example, enter 172.16.7.19 for the IP address. Click the
Add button to add the IP address in the address pool, and then click
Close. The resulting screen is shown below:
STEP 9: Select a time slot on one of the four E1 lines, and then click the Set HDLC
TSI button. In this example, select TS6 on the second E1.
63
STEP 10: Connect the PC running the MCID to the ENRS LAN port, and set the IP
address of the PC to the same subnet with that of the FM-60s. In this
example, the IP address of the PC running MCID should be 172.16.7.20.
!" HDLC TSI: 2nd E1/TS6 (this is the line connected to the central site)
STEP 1: Use the Console port to set up the Ethernet IP (LAN port) address of the
EMCU-B. (Note: The console cable is a DB9 null modem cable.) In this
example, set the IP address to 172.16.7.19 (The value of the subnet
mask uses the factory default). The commands are shown below:
>sys ip 172 16 7 19
>sys rst
64
STEP 2: Connect the EMCU-B LAN port to the PC running the MCID. In this
example, set the IP address of the PC to 172.16.7.20/16 (should be
located on the same subnet as the Ethernet IP address of EMCU-B).
STEP 3: Run the MCID on the PC and enter the EMCU-B configuration menu by
clicking the EMCU-B faceplate on the GUI.
65
STEP 4: Select a HDLC controller in the [HDLC] field by clicking 1 or 2. In this
example, click 1.
STEP 5: At the bottom of the screen in the [HDLC TSI] field, enter a value for the
E1 line and the time slot. In this example, select TS6 and E1-2
(timeslot 6 and the second E1), by clicking in the 6th column and 2nd row.
This results in the square in the 6th column and 2nd row changing to red,
as shown in the picture below.
66
8.4 In-band Management of FM-60s via E1 in
Multi-Grade
67
8.4.1 Multi-Grade In-Band Management with Multiple ENRS
In this application, both FM-60s in the central site and Area A require an EMCU-B
and ENRS. The FM-60 in Area B only requires the EMCU-B. The central site PC
running the MCID is able to manage both the remote FM-60s (Area A & Area B),
and the Area A PC running the MCID can manage the FM-60s in Area B and the
Central Site.
68
Set up the FM-60 in central site
!" ENRS: The central site HDLC port number (1-32) used to control the FM-60s;
E1, and time slot of the Area A (the E1/time slot is the line that the central
site uses to connect to the Area A)
!" ENRS:
69
STEP 1: Use the Console port to set up the Ethernet IP (LAN port) address of the
EMCU-B. (Note: The console cable is a DB9 null modem cable.) In this
example, set the IP address to 172.16.7.21 (The value of the subnet
mask uses the factory default). The console commands are listed as
follows:
>sys ip 172 16 7 21
>sys rst
STEP 2: Connect the EMCU-B LAN port to the PC running the MCID. In this
example, set the IP address of the PC to 172.16.7.20/16 (should be
located in the same subnet as the FM-60).
70
STEP 3: Run the MCID on the PC and enter the ENRS configuration menu.
STEP 4: Select a port in the [Port Select] field for the local FM-60 connection. In
this example, select Port 1. The selected port turns red in the [ENRS]
field.
71
STEP 5: Click the IP address… button to enter the IP address for the local FM-60.
In this example, type 172.16.7.21. Click the Add button to add the IP
address to the address pool, and then click Close. The pop-up screen is
shown below:
STEP 6: Click the Local icon at the top-left of the ERNS Configuration screen to
make an internal connection for the local FM-60, and then click the Set
HDLC TSI button at the bottom-left of the screen:
72
STEP 7: Select a port in the [Port Select] field for the remote devices. In this
example, select Port 2. The selected port turns red in the [ENRS] field.
STEP 8: Click the IP address… button to enter the IP address for the FM-60 in
area A. In this example, type 172.16.7.23. Click the Add button to add
the IP address in the address pool and click Close. The screen is shown
below:
73
STEP 9: Add two more IP addresses, one for the FM-60 in area B, and one for PC2.
In this example, add 172.16.7.26 (Area B) and 172.16.7.19 (PC2), and
then click the Close button. The screen is shown below:
STEP 10: Select a time slot on one of the four E1 lines, and then click the Set
HDLC TSI button. In this example, select TS1 on the 1st E1.
74
STEP 11: Connect the PC running the MCID to the ENRS LAN port, and set the IP
address of the PC to the same subnet with that of the FM-60s. In this
example, the IP address of the PC running the MCID should be
172.16.7.20.
75
Set up the FM-60 in Area A
!" ENRS:
STEP 1: Use the Console port to set up the Ethernet IP (LAN port) address of the
EMCU-B. (Note: The console cable is a DB9 null modem cable.) In this
example, set the IP address to 172.16.7.23 (The value of the subnet
mask uses the factory default). The console commands are listed as
follows:
>sys ip 172 16 7 23
>sys rst
76
STEP 2: Connect the EMCU-B LAN port to the PC running the MCID. In this
example, set the IP address of the PC to 172.16.7.19/16 (should be
located in the same subnet as the FM-60).
STEP 3: Run the MCID on the PC and enter the ENRS configuration menu.
77
STEP 4: Select a port in the [Port Select] field for the local FM-60 connection. In
this example, select Port 1. The selected port turns red in the [ENRS]
field.
STEP 5: Click the IP address… button to enter the IP address of the local FM-60.
In this example, type 172.16.7.23. Click the Add button to add the IP
address in the address pool, and then click Close. The screen is shown
below:
78
STEP 6: Click the Local icon on the ENRS Configuration screen shown below to
make an internal connection for the local FM-60, and then click the Set
HDLC TSI button:
STEP 7: Select a port in the [Port Select] field for the remote devices. In this
example, select Port 2 for the FM-60 in area B. The selected port turns
red in the [ENRS] field.
79
STEP 8: Click the IP address… button to enter the IP address of the FM-60 in
area A. In this example, type 172.16.7.26. Click the Add button to add
the IP address in the address pool, and then click the Close button. The
screen is shown below:
STEP 9: Select a time slot on one of the four E1 lines, and then click the Set HDLC
TSI button. In this example, select TS1 on the third E1.
80
STEP 10: Select a port in the [Port Select] field for the remote devices. In this
example, select Port 3 for the FM-60 in the central site and PC1. The
selected port turns red in the [ENRS] field.
STEP 11: Click the IP address… button to enter two IP addresses for the FM-60
in central site and PC1. In this example, add 172.16.7.21 and
172.16.7.20. And then click the Close button. The screen is shown
below:
81
STEP 12: Select a time slot on one of the four E1 lines, and then click the Set
HDLC TSI button. In this example, select TS1 on the second E1.
STEP 13: Connect the PC running the MCID to the ENRS LAN port, and set the IP
address of the PC to the same subnet with that of the FM-60s. In this
example, the IP address of the PC running the MCID should be
172.16.7.19.
82
Setting up the FM-60 in Area B
EMCU-B: IP address, HDLC, E1, time slot of Area B (the E1/time slot is the line
that the Area B uses to connect to the Area A)
In this example, the following parameters are used to configure the EMCU-B:
!" HDLC TSI: Third E1/TS1 (this is the line connected to Area A)
83
STEP 1: Use the Console port to set up the Ethernet IP (LAN port) address of the
EMCU-B. (Note: The console cable is a DB9 null modem cable.) In this
example, set the IP address to 172.16.7.2 (The value of the subnet mask
uses the factory default). The commands are shown below:
>sys ip 172 16 7 2
>sys rst
STEP 2: Connect the EMCU-B LAN port to the PC running the MCID. In this
example, set the IP address of the PC to 172.16.7.2/16 (should be
located on the same subnet with the Ethernet IP address of the EMCU-B).
84
STEP 3: Run the MCID on the PC and enter the EMCU-B configuration menu by
clicking the EMCU-B on the GUI.
85
STEP 5: In the [HDLC TSI] field, select an E1 line and the time slot. In this
example, click the TS1 on the third E1 (column 1, row 3).
86
8.4.2 Multi-Grade In-Band Management with a Single ENRS
This application only requires a single ENRS installed in the central site FM-60 to
implement multi-grade in-band management. The other FM-60s in Area A and
Area B only require an EMCU-B. This application uses TSI cross-connection to
achieve the in-band management.
87
Set up the FM-60 in central site
!" ENRS: The central site HDLC port number (1-32) used to control the FM-60s;
E1, and the time slot of Area A (the E1/time slot is the line that the central
site uses to connect to the Area A)
!" ENRS:
STEP 1: Use the Console port to set up the Ethernet IP (LAN port) address of the
EMCU-B. (Note: The console cable is a DB9 null modem cable.) In this
example, set the IP address to 172.16.7.21 (The value of the subnet
mask uses the factory default). The console commands are listed as
follows:
88
>sys ip 172 16 7 21
>sys rst
STEP 2: Connect the EMCU-B LAN port to the PC running the MCID. In this
example, set the IP address of the PC to 172.16.7.20/16 (should be
located in the same subnet as FM-60).
STEP 3: Run the MCID on the PC and enter the ENRS configuration menu.
89
STEP 4: Select a port in the Port Select field for the local FM-60 connection. In
this example, select Port 1. The selected port turns red in the [ENRS]
field.
STEP 5: Click the IP address… button to enter the IP address for the local FM-60.
In this example, type 172.16.7.21. The pop-up screen is shown below:
90
STEP 6: Click the Add button to add the IP address to the address pool, and then
click Close. The screen is shown below:
STEP 7: Click the Local icon on the left hand side of the ERNS Configuration
screen shown below to make an internal connection for the local FM-60,
and then click the Set HDLC TSI button:
91
STEP 8: Select a port in the [Port Select] field for the remote devices. In this
example, select Port 2 for the FM-60 in Area A. The selected port turns
red in the [ENRS] field.
STEP 9: Click the IP address… button to enter the IP address for the FM-60 in
area A. In this example, type 172.16.7.23. The pop-up screen is shown
below:
92
STEP 10: Click the Add button to add the IP address in the address pool, and then
click Close. The screen is shown below:
STEP 11: Select a time slot on one of the four E1 lines, and then click the Set
HDLC TSI button. In this example, select TS1 on the first E1.
93
STEP 12: Select a port in the [Port Select] field for the remote devices. In this
example, select Port 3 for the FM-60 in Area B. The selected port turns
red in the [ENRS] field.
STEP 13: Click the IP address… button to enter the IP address for the FM-60 in
area B. In this example, type 172.16.7.26. The pop-up screen is shown
below:
94
STEP 14: Click the Add button to add the IP address to the address pool, and
then click Close. The screen is shown below:
STEP 15: Select a time slot on one of the four E1 lines, and then click the Set
HDLC TSI button. In this example, select TS2 on the first E1.
STEP 16: Connect the PC running the MCID to the ENRS LAN port, and set the IP
address of the PC to the same subnet with that of the FM-60s. In this
example, the IP address of the PC running MCID should be 172.16.7.20.
95
Set up the FM-60 in Area A
The FM-60 in Area A only needs an EMCU-B. The messages can be transmitted
from Central Side to Area B via the cross-connection. The cross-connection is
configured in this FM-60
EMCU-B: IP address, HDLC, E1, time slot (the E1s/time slots are the lines that the
Area A uses to connect to the Area B and the Central Site)
In this example, the following parameters are used to configure the FM-60:
!" EMCU-B:
HDLC controller = 1
HDLC TSI: 2nd E1/TS1 (this is the line connected to the Central Site)
96
STEP 1: Use the Console port to set up the Ethernet IP (LAN port) address of the
EMCU-B. (Note: The console cable is a DB9 null modem cable.) In this
example, set the IP address to 172.16.7.23 (The value of the subnet
mask uses the factory default). The console commands are listed as
follows:
>sys ip 172 16 7 23
>sys rst
STEP 2: Connect the EMCU-B LAN port to the PC running the MCID. In this
example, set the IP address of the PC to 172.16.7.19/16 (should be
located in the same as the FM-60).
97
STEP 3: Run the MCID on the PC and enter the EMCU-B configuration menu by
clicking the EMCU-B on the GUI.
STEP 5: In the [HDLC TSI] field, select an E1 line and the time slot. In this
example, click the TS1 on the second E1.
98
STEP 6: Click the Set button at the bottom-left corner of the screen.
STEP 7: To make a cross-connection: E1-2/TS2 #-$ E1-3/TS2, click the TSI icon
on the upper left hand side of the screen.
STEP 8: In this example, select TS2 on the second E1 in the [E1 Time Slot] field.
Then click the Enter TSI button to enter the next screen.
99
STEP 9: Select TS2 on the third E1, and then click the Set TSI button to make a
cross connection. (Before selection, make sure the function of
Bi-direction is on.)
100
Setting up the FM-60 in Area B
EMCU-B: IP address, HDLC, E1, time slot of the Area B (the E1/time slot is the line
that the Area B uses to connect to the Area A)
In this example, the following parameters are used to configure the EMCU-B:
!" HDLC TSI: 3rd E1/TS2 (this is the line connected to the Area A)
101
STEP 1: Use the Console port to set up the Ethernet IP (LAN port) address of the
EMCU-B. (Note: The console cable is a DB9 null modem cable.) In this
example, set the IP address to 172.16.7.26 (The value of the subnet
mask uses the factory default). The commands are shown below:
>sys ip 172 16 7 26
>sys rst
STEP 2: Connect the EMCU-B LAN port to the PC running the MCID. In this
example, set the IP address of the PC to 172.16.7.7/16 (should be
located in the same subnet as FM-60).
102
STEP 3: Run the MCID on the PC and enter the EMCU-B configuration menu by
clicking the EMCU-B on the GUI.
103
STEP 5: In the [HDLC TSI] field, select an E1 line and the time slot. In this
example, click the TS2 on the third E1.
104
8.5 In-band Management via E1 to LAN
The FM-60 not only provides management in an E1 environment, but also in a LAN
environment. This application shows the combination of both environments. In
real applications, the customer may utilize the E1 network to manage the devices
located in the remote LAN. This provides a flexible way for network management.
In this application, the FM-60 in the central site communicates to the FM-60A in
the remote LAN via E1. Both FM-60s must have EMCU-B and ENRS cards. FM-60
A uses the LAN port of the ENRS to connect to the LAN. In the remote LAN, FM-60
B and FM-60 C only need the EMCU-B, and they connect to the LAN via the LAN
port of the EMCU-B.
Note: In this application, both console MCID based terminal and the console
FM-60 should be located in different subnets from any other FM-60s to
eliminate data loops.
105
8.5.1 Set up the FM-60 in the central site
!" ENRS: The central site HDLC port number (1-32) used to control the FM-60s;
E1, and the time slot (the E1/time slot is the line that the central site uses to
connect to the FM-60 A)
!" ENRS:
172.16.8.0/255.255.255.0/2/1
STEP 1: Use the Console port to set up the Ethernet IP (LAN port) address of the
EMCU-B. (Note: The console cable is a DB9 null modem cable.) In this
example, set the IP address to 172.16.7.21. The console commands are
listed as follows:
106
>sys ip 172 16 7 21
>sys rst
STEP 2: Connect the EMCU-B LAN port to the PC running the MCID. In this
example, set the IP address of the PC to 172.16.7.20/24 (should be
located in the same subnet as the FM-60).
STEP 3: Run the MCID on the PC and enter the Main Menu>System>
Administration menu to change the subnet mask for the Ethernet IP
address. In this example, set the subnet mask to 255.255.255.0 in the
[Ethernet Subnet mask] field. Click Set.
107
STEP 4: Enter the ENRS configuration menu.
108
STEP 5: Select a port in the [Port Select] field for the local FM-60 connection. In
this example, select Port 1. The selected port turns red in the [ENRS]
field.
STEP 6: Click the IP address… button to enter the IP address for the local FM-60.
In this example, type 172.16.7.21. The pop-up screen is shown below:
109
STEP 7: Click the Add button to add the IP address in the address pool, and then
click Close. The screen is shown below:
STEP 8: Click the Local icon on the ERNS Configuration screen shown below to
make an internal connection for the local FM-60, and then click the Set
HDLC TSI button:
110
STEP 9: Select a port in the [Port Select] field for the remote devices. In this
example, select Port 2 for the remote FM60s. The selected port turns red
in the [ENRS] field.
STEP 10: Click the IP address… button to enter the IP address and Subnet Mask
for the remote FM-60s. In this example, type
172.16.8.0/255.255.255.0. The pop-up screen is shown below:
111
STEP 11: Click the Add button to add the IP address in the address pool, and then
click Close. The screen is shown below:
STEP 12: Select a time slot on one of the four E1 lines, and then click the Set
HDLC TSI button. In this example, select TS1 on the second E1.
STEP 13: Connect the PC running the MCID to the ENRS LAN port, and set the IP
address of the PC to the same subnet with that of the FM-60s. In this
example, the IP address of the PC running MCID should be 172.16.7.20.
STEP 14: Click System Reset on the upper-right corner of the screen to reset
the FM-60.
112
8.5.2 Set up the FM-60 A
!" ENRS:
STEP 1: Use the Console port to set up the Ethernet IP (LAN port) address of the
EMCU-B. (Note: The console cable is a DB9 null modem cable.) In this
example, set the IP address to 172.16.8.1. The console commands are
listed as follows:
>sys ip 172 16 8 1
>sys rst
113
STEP 2: Connect the EMCU-B LAN port to the PC running the MCID. In this
example, set the IP address of the PC to 172.16.8.19/24 (should be
located in the same subnet as the FM-60).
STEP 3: Run the MCID on the PC and enter the Main Menu>System>
Administration menu to change the subnet mask for the Ethernet IP
address. In this example, set the subnet mask to 255.255.255.0 in the
[Ethernet Subnet mask] field. Click Set.
114
STEP 4: Enter the ENRS configuration menu.
115
STEP 5: Select a port in the [Port Select] field for the local FM-60 connection. In
this example, select Port 1. The selected port turns red in the [ENRS]
field.
STEP 6: Click the IP address… button to enter the IP address for the local FM-60.
In this example, type 172.16.8.1. The pop-up screen is shown below:
116
STEP 7: Click the Add button to add the IP address in the address pool, and then
click Close. The screen is shown below:
STEP 8: Click the Local button on the left side of the ERNS Configuration screen
shown below to make an internal connection for the local FM-60, and
then click the Set HDLC TSI button.
117
STEP 9: Select a port in the [Port Select] field for the remote devices. In this
example, select Port 2 for the PC in the central site. The selected port
turns red in the [ENRS] field.
STEP 10: Click the IP address… button to enter the IP address for the PC in the
central site. In this example, type 172.16.7.20. The pop-up screen is
shown below:
118
STEP 11: Click the Add button to add the IP address in the address pool, and then
click the Close button. The screen is shown below:
STEP 12: Select a time slot on one of the four E1 lines, and then click the Set
HDLC TSI button to finish the configuration. In this example, select
TS1 on the second E1.
119
8.5.3 Set up the FM-60 B and FM-60 C
The following parameters should be entered before setting up the FM-60 B and
FM-60 C:
Configuration Steps:
STEP 1: Use the Console port to set the Ethernet IP address by using the following
commands: (Note: The console cable is a DB9 null modem cable.)
>sys rst
STEP 2: Connect the EMCU-B LAN port to the PC running the MCID. In this
example, set the IP address of the PC to 172.16.8.X/24 (located in the
same subnet as the Ethernet IP address of the EMCU-B).
120
STEP 3: Run the MCID on the PC and enter the Main Menu>System>
Administration menu to change the subnet mask to 255.255.255.0 in
the Ethernet [Subnet mask] field. Click the Set button below, and then
click System Reset to restart the FM-60.
121
Part II: Common Units
Part II explains how to configure the parameters of the common units in FM-60. It
includes EPSU, EMCU-B, ELIU/ELIU2, and ENRS. The EPSU, EMCU-B and ELIU
units are essential components for running the FM-60. The ENRS is a network
management unit for E1 in-band management. It is an optional unit in the FM-60.
122
Chapter 9 EPSU - Power Supply Unit
The power supply unit (EPSU) performs DC-to-DC power conversion. It has
short-circuit and over-voltage protection function. Its faceplate is equipped with
test jacks for +5V, +12V, and –12V, respectively.
9.1 Faceplate
After the EPSU is installed, the PWR LED indicator will be lit to show the unit is
functioning. If failed, the FAIL LED indicator will be lit.
LED
Description
Indicator
Green –48 volts DC voltage is applied
PWR
Off Power is not connected.
Power source is unavailable or the EPSU
Red
FAIL fails.
Off The output power is operating normally.
Measuring
Description
Jack
+12V This jack is used for a voltameter to measure if
-12V system provides ±12V, and +5V to the channel
+5V units.
This jack is used for ground purpose during
measurement. When measuring the voltage, the
GND GND pointer of the voltameter should be placed
here. The other pointer is placed on one of the
above three measuring jacks.
123
Chapter 10 EMCU- Maintenance and Control unit
Maintenance and control unit (EMCU-B) is the core control element of FM-60. It
is in charge of operation, administration, maintenance, and provision of other
units. These functions are achieved via the CID operation. The following lists
the functions that EMCU-B does via CID.
!" Loopback tests of the channel units and ELIU/ELIU2/EMCU self test
124
10.1 Faceplate
LED
Description
Indicator
Green The unit is ready to serve.
INS The unit fails or is not ready to
Off
serve.
Red A major alarm occurs.
MAJOR
Off No major alarm is detected
Yellow A minor alarm occurs
MINOR
Off No minor alarm is detected
The ACO button is pushed to stop
Yellow the audio alarm but the alarm event
ACO
is not solved yet.
Off The ACO button is not pushed.
Yellow Collision occurs over LAN.
COL
Off No collision over LAN
Green Data is transmitted over LAN.
ACT
Off No data over LAN.
Push Button Description
ACO Alarm Cut Off- to stop the audible alarm.
Connector Description
Console Console and CID are both RS-232 DB9
connectors. For their pin assignments, refer
CID
to Appendices.
LAN port is a 10BaseT Ethernet connector. For
LAN
its pin assignments, refer to Appendices.
125
10.1.1 Console Port
The Console physical interface is RS-232 interface port, which meets the following
specifications. It is used to connect to console for local management through a
9-pin RS232 cross-over cable.
The CID port is a 9-pin RS-232 interface. It is used to connect to a null modem
or a modem. Its specification and pin definitions are the same as Console COM
port.
For null modem connection, use a standard null modem cable to connect the
FM-60 CID COM port to a workstation. For a modem connection, use a straight
through cable to connect. Baud rate of the CID port and the COM port of the
workstation should be set to the same rate. The default rate of the FM-60 is 38.4
Kbps.
The reset push button is a hardware reset control button. It is used to reset the
system. When the COM1/COM2 baud rate, SNMP parameters or IP address is
changed, push the reset button once to start new settings. This function can also
be performed via the CID software.
126
10.1.4 Alarm-Cut-Off Push Button
The ACO push button is labeled ACO on front panel of EMCU-B and it is used to
stop the audible office alarm. However, this button has no effect on solving the
problems occurred. The problem should be handled by the maintenance
personnel.
The CID software management is achieved via a 10BaseT LAN port. Centralized
control of FM-60s can be operated under the Ethernet environment. The network
segment of your PC LAN port must be the same as the FM-60 LAN port.
Use a cross-over RJ45 cable to connect the LAN port and the PC Ethernet card.
127
10.2 Configuration
Enter the FM-60 CID. On the main menu, click the EMCU-B faceplate to enter the
EMCU configuration screen.
You can save all the current configurations on your workstation. These
configurations include settings like system parameters, TSI, ELIU/ELIU2 and
channel units.
STEP 4: Go to the file directory that you saved the data and see if the file exists.
128
Note: Always use this function to back-up the configurations in the storage
device when changing the system parameters.
To download the stored configurations to the FM-60 flash memory, follow the
steps below:
The EMCU-B provides a self-evaluation test. It is used to test the board circuit.
The result will be reported a few seconds after the Self Test button is clicked.
129
Chapter 11 ELIU/ELIU2 - Line Interface Unit
11.1 Faceplate
130
11.2 Jumper Settings
The following figure diagrams the positions of each jumper that should be
adjusted before you insert the card into the chassis slot.
Each jumper has three pins and they are labeled 1, 2 and 3.
Note: The settings for 3rd E1 and 4th E1 are available for ELIU only.
131
11.3 Configuration
The following table lists the functions of each parameter. After you have filled in
a parameter in each field, click the set button to apply the settings.
Field Function
CRC-4 Enable Once the CRC-4 function is enabled, the Bit 1 of Timeslot 0 will
be used for Cyclic Redundancy Check.
CAS Enable Once the CAS function is enabled, TS16 will be used for
Channel Associated Signalling function.
Comment This is a user-defined description of the E1 line.
Note: the factory default values of the fields, CRC-4 Enable and CAS Enable, are
enabled.
132
11.4 Maintenance
Start the CID and enter the ELIU maintenance screen that is shown below. On the
maintenance screen, you can perform self-test and initialize the loopback.
STEP 1: Click the self test button on the ELIU Maintenance screen.
STEP 2: On the self test screen, click the start test button.
STEP 3: After self-test is completed, the system will report the result.
Use the scroll bar to select a type of the loopback from the Loopback field, and
click the Set button. Click Ok on the prompt. The prompt “Enable Loopback
Success” displays. The Status field displays the loopback type. To release the
loopback, use the scroll bar to select Normal from the Loopback field and click Set
button again. And then click Ok on the prompt. The Status field will display
Normal. There are three types of the loopback selectable: Payload, Line and
Local.
133
Chapter 12 ENRS - Network Routing Server
Integrating the ENRS (Network Routing Server), at least one hundred FM-60s can
be simultaneously managed. It can be installed in any Slot 1 to Slot 15. An
FM-60 can mount up to three ENRS. Each ENRS supports 32 ports. Each port
can configure 32 sets of FM-60s or 32 networks consisting of FM-60s.
This chapter only introduces the hardware features and basic CID configuration
for the ENRS. The inband management procedure is stated in Chapter 8.
12.1 Faceplate
LED
Description
Indicator
Green The unit is ready to serve.
INS The unit fails or is not ready to
Off
serve.
Yellow Collision occurs over LAN.
COL
Off No collision over LAN
Green Data is transmitted over LAN.
ACT
Off No data over LAN.
Connector Description
LAN port is a 10BaseT Ethernet connector used to
LAN connect to the PC in Central office for management.
For its pin assignments, refer to Appendices.
134
12.2 Configuration
STEP 1: Self Test: to perform the self test of the board circuit.
STEP 2: Port Select: To select a HDLC port. There are 32 ports on the ENRS.
Each port can manage 32 subnets consisting of FM-60.
135
STEP 3: Click the IP Address… button, and the screen below will display.
On the screen, type the HDLC IP address and subnet mask of the remote FM-60.
Click the Add button to add the entry.
STEP 4: E1-1 to E1-4: To select an E1 time slot from 1st E1 to 4th E1 to which the
remote FM-60 is connected. Then click the Set HDLC TSI button to apply
the setting.
136
Part III: Voice Channel Units
Part III explains how to configure the parameters of the voice channel units in
FM-60. These channel units include EE&M, EEM2, EEM4, ELTU, EFXO-8P and EFXS.
The EE&M, EEM2 and EEM4 provide the E & M signalling for the interconnection
between the voice exchanges. The ELTU is used for the voice DID application. The
EFXO-8P channel unit provides the phone interface to connect to the PBX, and the
EFXS channel unit provides the switch interface to connect to the phone.
137
Chapter 13 E&M Voice Channel Units
13.1 Application
There are four voice channel units, EE&M, EEM2 and EEM4 for voice and analog
leased line applications. Either of which transfers the signals between voice and
A-law PCM (ITU-T G.711) code (through CODEC).
!" EE&M: for 2-wire/4-wire applications. 2-wire or 4-wire are CID software
selectable. This unit provides four ports.
!" EEM2: for 2-wire applications. This unit provides eight 2-wire 600ohm/900
ohm VF (Voice Frequency) ports and E/M signaling processing. The
selection of 600 ohm or 900 ohm should be achieved via the onboard DIP
switches.
!" EEM4: for 4-wire applications. This unit provides eight 4-wire 600 ohm VF
(Voice Frequency) ports and E/M signaling processing.
Note: For 4-wire application, T1/R1 is defined as Transmit and T/R as Receive.
For 2-wire application, T/R is defined as both Transmit and Receive.
138
13.2 Faceplate
13.2.1 EE&M
139
13.2.2 EEM2
Connector Description
140
13.2.3 EEM4
After inserted in the slot, INS and TEST LED indicators will blink in sequence, then
the INS blinks twice, and finally, the TEST blinks twice.
141
13.3 EEM2 DIP Switch Settings
The EEM2 has eight DIP switches, S1 ~ S8 on board for user’s configuration. S1
~ S8 are used to specify the wire features, 2 wire 600 ohm or 2 wire 900 ohm for
Port 1 to Port 8 respectively. Each switch has six small switches. Their settings
are described in the following table.
Note: Before you slide the EEM2 into the slot, make sure you have set a correct
DIP switch setting for each port. DIP switch setting is not available and
unnecessary for EE&M and EEM4.
142
13.4 Configuration
On the configuration screen, you have to click a port from the Port Select field first.
Then, configure the parameters. The following table lists the possible parameters
for user’s configuration. After you have filled in a parameter in each field, click
the Set button to apply the settings.
Wire Type 2W, 600 ohm 2W, 900 ohm 4W
Level adaption level -25.5 ~ + -8.0 ~ -30.5 ~-0.5 -8.0 ~ -19.0 -17.0 ~
143
13.5 Maintenance
The self test is used to verify the operation of the board circuit. Click the Self
Test button to initialize the test. The test results will appear in a minute.
You can perform the Line loopback by clicking the To Line button. The Loopback
Status field displays Loopback Toward Line. To release the loopback, click the
Release button. The Loopback Status field displays Normal.
Click E-lead, M-lead, or both leads and then click the Enable button to be made
busy. The direction of the FM-60 E-lead is defined as Transmit, and the M-lead is
144
Receive. The selected E-Lead or M-Lead will be grounded and the corresponding
outgoing ABCD bits over E1 will be set to 1.1.0.1 respectively.
145
Chapter 14 ELTU- Loop Termination Unit
14.1 Application
The Loop Termination Unit (ELTU) is suitable for DID application shown below. It
is used for voice signal application between the FM-60 E1 multiplexer and the DP
(dial pulse) or DTMF (dual-tone multi-frequency) loop trunk of the switching
device. The unit converts normal and reverse battery conditions from the trunk
circuit into signalling bits for digital transmission and converts received signalling
information into loop closures for the trunk circuit.
146
14.2 Faceplate
147
14.3 Configuration
On the screen, there are up to four ports can be configured. Follow the steps
below to configure the ELTU.
STEP 2: Select a parameter in the [Input level] and [Output level] fields.
Field Value
Level adaption [input] -10.5 ~ +4.5 dB
Level adaption [output] -11.5 ~ +3.5 dB
148
14.4 Maintenance
Enter the ELTU maintenance screen that is shown below. The screen will indicate
make busy status. You can also perform self test for each port.
The self test is used to verify the operation of the board circuit. Click the Self
Test button to initialize the test. The test results will appear in a minute.
Click the Enable button to make the port busy, or click the Disable button to
retrieve the original status. When the Make Busy function is made busy, the
Status field displays Make Busy. When it is disabled, the Status field displays
Loop Busy.
149
Chapter 15 EFXO-8P and EFXS-8P
15.1 Application
Each EFXO-8P and EFXS-8P provides eight voice frequency interfaces. The
configurations of both cards are the same. The figure below depicts the
application of the POTS extension service.
150
15.2 Faceplate
The EFXO-8P and EFXS-8P have common faceplate LED indicators and connectors.
They both have eight LEDS (numbered 1-8) and eight LAN ports on the faceplate.
The following table explains the faceplate LED indicators and connectors of the
EFXO-8P. The EFXS-8P faceplate is the same as the EFXO-8P.
LED
Description
Indicator
At least one port of the unit is
Green
INS configured via CID.
Off None of the ports is configured.
When the EFXS-8P is off hook, the
correspondent LED of both EFXS-8P
and EFXO-8P will turn on, or when the
Green
loopback is initialized, the
correspondent LED on either EFXO-8P
or EFXS-8P will turn on.
P1-P8
When both EFXO-8P and EFXS-8P are
idle, and the EFXO-8P receives the
Blink ringing information from the PSTN or
PABX, the correspondent LED on both
EFXS-8P and EFXO-8P blinks.
Off The port is idle.
Connector Description
RJ11 ports. Their pin assignments are listed in
P1-P8
Appendices.
151
15.3 Configuration
On the left of the Configuration screen, the faceplate of the card is shown to
indicate the card status. You can also find the board version and the port you are
configuring above the faceplate.
152
The configuration parameters of EFXO-8P and EFXS-8P are the same. Select a
port by clicking the number button, 1-8, and configure the port’s Input Level and
Output Level.
153
15.4 Maintenance
The Self test is used to verify the operation of the board circuit. Click the Self
Test button to initialize the test. The test results will appear in a minute.
You can perform the Line loopback by clicking the To Line button. The Loopback
Status field displays Loopback Toward Line. To release the loopback, click the
Release button. The Loopback Status field displays Normal.
154
Part IV: Data Channel Units
Part IV explains how to configure the parameters of the data channel units in
FM-60. These data channel units include the G.703 64kbit/s, ISDN BRI,
U-interface, V.35 DSU, sub-rate, MSDSL and ADSL.
!" Chapter 16: Describes EE0U – G.703 64Kbit/s codirectional data channel unit
!" Chapter 17: Describes EBRI – ISDN basic rate access data channel unit
!" Chapter 18: Describes EBCU – ISDN U-interface data channel unit
!" Chapter 19: Describes EDSU – V.35 DSU data channel unit
155
Chapter 16 EE0U- G.703 64K Codirectional
Unit
16.1 Application
The G.703 64Kbit/s codirectional unit (EE0U) is one of the data channel units of
FM-60. It is used for tandem application. There are at least eight G.703 64
Kbit/s codirectional ports on the EE0U channel unit. The application of EE0U is
shown below.
156
16.2 Faceplate
157
16.3 Configuration
158
16.4 Maintenance
Click the Maintenance tab to enter the EE0U maintenance screen as the
following displays:
The self test is used to verify the operation of the board circuit. Click the Self
Test button to initialize the test.
You can perform the Line loopback by clicking the To Line button or perform the
loopback toward the DTE by clicking the To User button. After performing the
loopback, the Loopback Status field will display the test status. To release the
loopback, click the Release button. The Loopback Status field displays Normal.
159
Chapter 17 EBRI- Brite Unit
17.1 Application
The BRITE unit (EBRI) provides ISDN basic rate access at U-interface that is used
to extend ISDN basic rate service. The ISDN U-interface provides full duplex,
basic rate (2B+D) digital transmission on two-wire metallic local line. The
application of the EBRI is shown below.
160
17.2 Faceplate
Faceplate Description
It lights to indicate at least one port is
INS Green
configured via the CID to serve.
It lights to indicate the incoming of
LOS Red
either port signal is lost.
It lights to indicate that B1 loopback
LPBK Yellow
or B2 loopback is enabled.
Connector Description
T/R is an RS-232 DB9 connector. It contains two
T/R ports. Each port has a TIP and a RING signals.
For detailed pin assignments, refer to Appendices.
161
17.3 Configuration
Enter the EBRI CID configuration screen. There are two ports configurable. The
screen is shown below.
162
transmission wires.
163
17.4 Maintenance
Enter the EBRI CID maintenance screen that is shown below. On the maintenance
screen, you can perform self test, manual test, and loopback test.
The self test is used to verify the operation of the board circuit. Click the Self
Test button to initialize the test. The test results will appear in a minute.
You can perform the loopback toward the E1 line (To Line) or toward the DTE (To
User) by marking the checkbox B1, B2 or D. And click the Set button to perform
the loopback. To release the loopback, cancel the mark on the checkbox and click
the Set button again.
164
17.4.1 EBRI EOC to CPE Test
The EBRI EOC to CPE screen involves two panels, To CPE and From CPE. Their
functions and operations are introduced below.
!" To CPE
STEP 1: Select an address (0~7) node to which that the EOC command will be
sent.
Address is a node. This node will loop back signals upon receiving an EOC
command. Address 7 means broadcast; all the downstream nodes should
loopback the signals upon receiving the command. Address 0 means the NT1
(CPE as well).
For example, address 2 is the second node that should loopback the signal.
Select the Standard or Non-standard field.
165
!" [53] Request CCCR
STEP 3: If Non Standard is selected, you will need to select “data” or “message”
in the [data/message] field. And enter the [Information] field in HEX
mode.
STEP 4: Click the start button to send the EOC to CPE. A Set Start EOC Success
message prompts.
STEP 5: To stop the loopback, click the stop button to end the test. A Set Stop
EOC Success message prompts.
This panel shows the status of the selected downstream CPE node. When an EOC
command is sent toward downstream, this part can tell if the appointed CPE node
responds as requested.
166
17.4.2 EBRI Performance
The EBRI Performance screen covers two panels, near end and far end
performances. On either near end or far end, the system will collect and monitor
the statistics of ES, SES, and UAS.
167
The default value of each register is 900. To set a new threshold,
STEP 3: Click the Set Threshold button to apply the new settings.
168
Chapter 18 EBCU- ISDN U-interface Unit
18.1 Application
EBCU is an ISDN U-interface 64 Kbit/s or 128 Kbit/s channel unit. The ISDN
U-interface provides full duplex, basic rate (2B+D) digital transmission on
two-wire metallic local line. Via two-wire metallic line, EBCU connects to four
128 Kbps baseband modems through the ISDN U-interface. The application of
EBCU is shown below.
The EBCU can be connected to the proprietary CT-50 Subrate NTU and CT-128
Multi-Rate NTU/DSU.
169
18.2 Faceplate
170
18.3 Configuration
Enter the EBCU configuration screen. There are four ports to configure.
STEP 2: Tick B1 Channel, B2 Channel or both from the Channel Enable field. D
Channel is functional for the EBCU.
STEP 3: Select a mode and EOC loopback from the Operations and Sealing
Current field.
171
The following table describes the parameters of each port.
Field Parameter
Channel Enable B1 channel, B2 channel
Operation and
sealing current
Mode LULT, w/o sealing current;
LULT, w/sealing current
LUNT
EOC loopback The direction of Embedded Operations Channel loopback:
Single direction: Once the EBCU receives EOC commands
from upstream, it will loopback the incoming signals toward
the upstream.
Both directions: Once the EBCU receives EOC commands
from upstream, it will loopback the incoming signal toward
the upstream. At the same time, the incoming signals
from downstream will also be looped back.
172
18.4 Maintenance
Enter the EBCU Maintenance screen that is shown below. The screen allows you
to perform the self test, manual test, and Loopback via Message.
The manual test and the Test Items fields are reserved only.
173
18.5 EOC to CPE Test
The EOC to CPE screen involves two panels: To CPE and From CPE. Their
functions and operations are introduced below.
To CPE
STEP 1: Select an address (0~7) from the Address field to which the EOC
command will be sent.
Address is a node. This node will loop back signals upon receiving an EOC
command. Address 7 means broadcast; all the downstream nodes should loop
back the signals upon receiving the command. Address 0 means the NT1 (CPE as
well).
For example, address 2 is the second node that should loopback the signal. Click
Standard or Non-standard button.
174
!" [52] B2 loopback
STEP 3: If Non Standard is selected, you will need to enter “data” or “message”
in the [data/message] field. And enter the [Information] field, in which
the digit uses HEX mode.
STEP 4: Click the start button to send the EOC to CPE. A Set Start EOC Success
message prompts.
STEP 5: To stop the loopback, click the stop button to end the test. A Set Stop
EOC Success message prompts.
From CPE
This panel shows the state of the selected downstream CPE node. When an EOC
command is sent toward the downstream, this part can tell if the appointed CPE
node responds as requested.
175
18.6 Performance
The EBCU Performance screen covers two panels, near end and far end
performances. The near end or far end collects and monitors the statistics of ES,
SES, and UAS.
176
To reset the performance of each item, click the Reset Perf button. The
performance will start counting from zero.
STEP 2: Enter the Remote Control screen. You can configure all the functions
that are performed locally at the CT-128 installation site.
!" Loopback tests (Local loopback, Digital loopback, Remote digital loopback)
and sending the test patterns (511 or 2047) to the network.
177
Figure 18-7 Remote Configuring CT-128
178
18.8 Remotely Configuring the CT-50
To configure the remote CT-50, on the Configuration menu, select a port that is
connected to the CT-50, and click Remote Control tab to open to the Remote
Control screen.
!" X.50:
This multiplexes the sub-rate signals to one or two time slots. It occupies two
time slots (the five sub-rate user ports share the time slots.)
!" DS0A:
This mode maps the sub-rate signals into one time slot. Each port uses one time
slot (each sub-rate user port uses a time slot.)
179
Follow the steps below to configure the remote CT-50.
STEP1: Click the Set as X.50 or Set as DS0A button to specify the CT-50 as a
X.50 or DS0A unit.
STEP2: The [Set X.50 type success] or [Set DS0A type success] message
prompts.
STEP4: The [Current Type] field will change from Undefined to the type you
select.
STEP5: Select a port form the [Port Select] field to configure the parameters.
180
For X.50 type, the two ports share two times slots. The point is how to apply
each port to the time slots. X.50 supports data rates from 2.4 Kbps to 128 Kbps.
STEP5: Click B1 or B2 channel to which you wish to apply the above settings.
STEP6: Click on the blue unused time slot. The following lists the conditions for
each data rate and interface.
!" When Port 1 is set to Sync, it provides up to 128Kbps. Ports 2-5 can be set to
19.2 Kbps at highest data rate.
!" Each B1 and B2 channel has 64K. Both are listed as a table. The following
diagrams the B1 channel after B1 button is clicked.
181
STEP7: Click Select and return to the previous screen.
The DS0A mode provides 2.4 K ~19.2 K data rates for each port.
STEP 1: Select a port by clicking a port number 1 or 2 from the [Port Select] field.
182
Chapter 19 EDSU- DSU Data Port Units
19.1 Application
The EDSU is a DSU Data Port unit. It provides Nx64 Kbps data service equipped
with two V.35 data ports. Its application is shown below.
183
19.2 Faceplate
184
19.3 Configuration
Enter the EDSU CID, and then click the configuration tab on the screen. There
are two ports to be configured as the following shows:
STEP 1: Click button 1 or button 2 from the [Port Select] field to choose the port
you want to configure.
STEP 2: Fill in a parameter in each field. The following table lists the parameters
of each port.
Field Parameter
N*64K N= 1~31
Interface V.35, view-only
RTS
!" Normal: Before sending commands to the unit, the DTE should
(Ready to
send the RTS signal first as a request call.
send)
!" Permanent ON: Before sending commands to the unit, The DTE
does not need to send the RTS signal.
Tail
!" Enable: the transmit clock from DTE is used to sample the
transmit data (TD).
!" Disable: the transmit clock from DCE is used to sample the
transmit data.
185
STEP 3: Click the Set button. (click the Deconfig button to give up the
configuration for selected port; click the Deconfig ALL button to give up
the configuration for both two ports; click the Refresh button to refresh
the configuration screen.)
19.4 Maintenance
After configuring the EDSU, click the Maintenance tab to enter the EDSU
maintenance screen as the following shows:
The self test is used to verify the operation of the board circuit. Click the Self
Test button to initialize the test. The test results will appear in a minute.
186
This field is reserved only.
You can perform the Line loopback by clicking the To Line button or perform the
loopback toward the DTE by clicking the To User button. After performing the
loopback, the [Loopback Status] field will display the test status. To release the
loopback, click the Release button. The [Loopback Status] field displays
Normal.
187
Chapter 20 ESUB- Subrate Unit
20.1 Application
ESUB is a subrate unit. It is equipped with five V.24 DTE interfaces for connection
to the customer equipment. Customer data is multiplexed /de-multiplexed to or
from the B channels according to the scheme described in division 3 of X.50.
!" DS0A
!" X.50
188
20.2 Faceplate
189
20.3 Configuration
This multiplexes the sub-rate signals to one or two time slots. It occupies two
time slots (the five sub-rate user ports share the time slots.)
This maps each sub-rate signal into one time slot. It occupies five time slots
(each sub-rate user port uses a time slot.)
190
Follow the steps to configure the ESUB as X.50 or DS0A.
STEP1: Click the Set as X.50 or Set as DS0A button to specify the ESUB as a
X.50 or DS0A unit.
STEP2: The “Set X.50 type success” or “Set DS0A type success” message
prompts.
STEP4: The [Current Type] field will change from Undefined to the type you
select.
STEP5: Select a port form the [Port Select] field to configure the parameters.
For X.50 type, the five ports share two times slots. The point is how to apply
each port to the time slots. Complete the following steps to configure each port.
191
STEP3: Select a mode, Sync or Async in the [Interface] field.
STEP5: Click B1 or B2 channel to which that you wish to apply to above settings.
STEP6: Click on the blue unused time slot. The following lists the conditions for
each data rate and interface.
!" When Port 1 is set to Sync, it provides 56K/64K data rates. Port 2 to Port 5
can be set to 19.2 K at highest data rate.
!" Each B1 and B2 channel has 64K. Both are listed as a table. The following
diagrams the B1 channel after B1 button is clicked.
192
20.3.2 DS0A Mode
The DS0A mode provides 2.4 K ~19.2 K data rates for each port.
Configuration Procedures:
STEP 1: Select a port by clicking a port number (1 ~5) from the [Port Select]
field.
193
20.4 Maintenance
After configuring the ESUB, click the Maintenance tab to enter the ESUB
maintenance screen as the following shows:
The self test is used to verify the operation of the board circuit. Click the Self
Test button to initialize the test. The test results will appear in a minute.
You can perform the BER Test by clicking the Start button. The BER test sends
out 2X15E-1 test pattern. To stop the test, click Stop. The Get Result button
allows you to display the BER test result.
You can perform the Line loopback by clicking the To Line button or perform the
loopback toward the DTE by clicking the To User button. After performing the
loopback, the [Loopback Status] field will display the test status. To release the
loopback, click the Release button. The [Loopback Status] field displays Normal.
194
Chapter 21 EMSU - MSDSL Unit
The EMSU is the line-card type of multi-rate Symmetric Digital Subscriber Line
(SDSL) LTU. It has 2B1Q-based SDSL interface on the network side, and data is
transmitted to network through one single twisted pair with data rate from 64
kbps to 1984 kbps. It provides two SDSL data port and each data port supports
data rate from 64 Kbps to 1984 Kbps.
21.1 Application
The EMSU is a plug-in channel unit of the FM-60 and performs as the LT mode of
the MSDSL line. It works with the CT-210 MSDSL NTU (acts as NT mode) to
provide Nx64K data access.
195
21.2 Faceplate
LB
No loopback or self-test is
Off
undergoing.
Connector Description
196
21.3 Configuration
The EMSU supports two ports. To configure the port, enter the EMSU CID
configuration screen.
STEP 2: Specify the value (1 to 31) in the Data Rate (Nx64K) field.
To deconfigure a port, click the Deconfig button. The link to the remote CT-210
will be terminated in two minutes. To reset the line rate, click the Deconfig
button, select the data rate, and click Set to apply the setting. The line rate will
be effective immediately.
197
21.4 Maintenance
The Self test is used to verify the operation of the board circuit. Click the Self
Test button to initialize the test. The test results will appear in a minute.
You can perform To User and To Line loopbacks. The [Loopback Status] field
displays the loopback that is activated. To release the loopback, click the
Release button. The [Loopback Status] field displays Normal.
You can perform the BER Test by clicking the Start button. The BER test sends
out 2X15E-1 test pattern. To stop the test, click Stop. The Get Result button
allows you to display the BER test result.
198
21.5 Performance
The Performance screen allows you to collect the statistics of ES, SES, and UAS at
near and far ends for the past four quarters. You can reset the value by clicking
the Reset Perf button, or set the alarm thresholds by clicking the Set Threshold
button.
199
21.6 Remote Control over the CT-210 MSDSL NTU
The Remote Control screen allows you to apply the line rate setting of the EMSU to
the remote CT-210, and it also allows you to perform the loopbacks to the CT-210.
The [Remote Control] > [Configuration] screen displays the CT-210 LED status,
the hardware version, and the software version for monitoring. It also allows you
to save the line rate setting of the EMSU to the remote CT-210. Click the VCDB
Save button, the line rate setting of the EMSU will then be remotely written to the
CT-210 flash memory. If this function is not performed, the CT-210 may be
rebooted with the old parameters, and thus the link between the EMSU and
CT-210 may not be able to be connected.
200
21.6.2 Loopback Test to the CT-210
The Loopback screen allows you to perform Line, Payload, and Local loopbacks.
201
Chapter 22 ELAN- LAN Extension Unit
22.1 Overview
The ELAN is a channel unit of the FM-60 E1 Flexible Multiplexer. An ELAN can be
installed in any CU slot and up to three ELAN modules can be installed in one
FM-60 shelf. An ELAN is designed to provide LAN extension between networks. In
addition to bridging function, this unit also supports static routing. With the use of
the ELAN module, customers can easily establish an intra-network connecting
multiple distant locations.
Each ELAN module is equipped with one 10/100BaseT Ethernet port on its front
panel. This RJ-45 port is used to connect to the Local Area Network. Each ELAN
supports eight HDLC controllers. That is, up to eight different paths can be
established via the TSI assignment on the FM-60. Each path can be allocated its
own bandwidth (E1 time-slot) and may go to any E1 line. Each card can support a
total bandwidth of up to 32 time-slots. The destination of each path can be either
an IP address, or a sub-network with a user-defined network mask.
!" Equipped with eight HDLCs which support up to eight different paths
202
22.2 Applications
Builds LAN connections between the headquarters and all branches to provide an
enterprise intranet, and also connect to an ISP to provide Internet service.
203
22.3 Faceplate
The ELAN is equipped with three LED indicators and one 10/100 BaseT RJ45
connector.
204
22.4 Configuration
Enter the FM-60 ELAN configuration main menu. This menu includes three
functional panels: Type, Common Configurations, and Port Configuration. The
following section describes how to configure the card in more detail.
There are two card types: bridge and router. Define the card type by clicking on
the Set as Bridge or Set as Router button. Before the card is configured or
when it is disabled, the [Current Type] field reads “Undefined”.
!" Bridge: When the Set as Bridge button is clicked, a pop-up message, Set as
Bridge OK! will prompt the user to confirm this selection. The three
buttons: LAN, Static, and STP in the Common Configurations> Bridge
panel will be activated. The [Current Type] field displays Bridge.
!" Router: When the Set as Router button is clicked, a pop-up message, Set as
Router OK! will prompt the user to confirm this selection. The two buttons:
LAN and Router in the Common Configurations> Router panel will be
activated. The [Current Type] field displays Router.
205
To disable the card, click on the Disable Type button. The [Current Type] field
will indicate Undefined.
Bridge mode includes settings for the LAN interface, static MAC entry, spanning
tree protocol (STP), and port configurations. To run in bridge mode, you only need
to set up the port configurations and TSI cross connection. The port
configurations are stated in the Basic Configurations below. The explanation
of basic configurations will be followed by an explanation of advanced functions
like setting the LAN interface, creating static MAC entries, and STP. Refer to
Chapter 7 to set the TSI, and establishing the connection.
Basic Configurations
In the Port Configuration panel under the ELAN main menu, you can configure the
parameters for each port. Select a specific port by clicking on buttons 1 through
8 in the [Port Select] field. These buttons will open the configuration menu for
each port. After you configure the port, click Set to apply the settings.
To modify the settings after the port is set up, deconfigure the port by clicking
Deconfig, and then change the settings. The Deconfig All button is used to
206
deconfigure all eight ports of the card. When the port is configured, the Status
field will indicate Configured. If it is not configured or it has been subsequently
deconfigured, it reads Unconfigured.
Each port supports from 1 x 64 Kbps to 31 x 64 Kbps. The first number here
represents the time slot’s number. A single port can support up to 31 time slots.
However, there are a total of 32 time slots to be allocated amongst the eight ports.
For example, if port 1 occupies two time slots then the rest of the ports can only
use 29 time slots (32-2 = 30).
This field is used to set up the session link protocol. When HDLC is selected, you
also need to fill in the next [Keep-Alive] field. In PPP mode, the [Keep Alive] field
is an optional field to complete. In Ethernet mode, the [Keep Alive] field is
invalid.
!" Keep Alive (0-255): This field is used to set the interval at which the
Keep-Alive message will be sent. The value ranges from 0 to 255 seconds.
A zero (0) means no Keep-Alive message will be sent.
This field is functional when HDLC or PPP protocol is selected. In HDLC mode,
this field must be set. The Keep-Alive message is sent to inform the remote end
that the port is ready. The remote end should return an acknowledgement
packet upon receiving the Keep-Alive message. The session will then be
established. In PPP mode, the Keep-Alive message is sent at regular intervals to
inform the remote end that the port is operating.
!" PPP Authen. Method: In PPP mode, if authentication is required, you can
select an Authentication Method (CHAP or PAP) in the [PPP Authen. Method]
field, and fill in the [PPP Authen. Method] and [PPP Authen. Password] fields.
If authentication is not required, select None in the [PPP Authen. Method]
field.
!" PPP Authen. User Name/ PPP Authen. Password: it is necessary to fill in these
two fields when an authentication method (CHAP or PAP) is selected.
!" STP: To use the port’s STP feature, you must first enable the card’s STP
feature from the Common Configurations> STP menu.
207
Advanced Configurations
For advanced configuration of the LAN interface, Static MAC entries, and STP
functions, refer to the information below.
Fill in the IP address and subnet mask for the LAN interface, and click Set to apply
the settings. The IP address here can be used for remote access functions like
ping.
208
!" Create/ Delete static MAC entries
To add a static MAC entry, fill in the MAC address and port MAP. Click Add, and
an Add OK! Pop-up message will prompt the user for confirmation. Up to twenty
MAC entries can be established in the table.
There are nine interfaces defined in the [Port Map] field: the LAN and ports 1
through 8. The number zero (0) represents Filter. Packets will be filtered-out
when they are not destined to an appointed MAC address. The number one (1)
represents Forward. Packets will be forwarded to the defined MAC address via
the Port Map. The following table describes the port map for each interface:
Interface Port Map
LAN 100000000
Port 1 010000000
Port 2 001000000
Port 3 000100000
Port 4 000010000
Port 5 000001000
Port 6 000000100
209
Port 7 000000010
Port 8 000000001
For example, an entry with the MAC address 00:06:10:0a:00:6b and the Port
Map 010000000 is established. It means packets are forwarded to the
destination, 00:06:10:0a:00:6b via Port 1.
To delete a MAC entry, highlight an established MAC entry, and click Delete. A
Delete OK! pop-up message will prompt the user for confirmation.
The Spanning Tree Protocol screen sets the STP function for the LAN interface and
Ports 1 through 8. To enable the STP protocol, select Enable in the [STP] field.
Enter a value ranging from 0 to 65535 in the [Priority] field. Disable the STP
function for the LAN interface by choosing Disable in the [LAN Port Operation]
field; to disable STP for a specific port, enter the port’s configuration menu; this is
described further below.
210
22.4.3 Router mode parameters
Router mode includes settings for the LAN interface, static routes, and port
configurations. These functions are discussed in more detail below.
Set up the IP address and subnet mask for the LAN interface. You can enable the
Routing Information Protocol (RIP) by selecting Enable in the RIP mode on the
LAN interface, and select the necessary RIP protocol in the following fields. When
the RIP Authentication field is enabled, also fill in the [RIP Authentication Code]
field.
211
!" Routing
RIP:
To add a static route, enter the destination IP address, subnet mask, and the next
hop (normally default gateway) IP address to which packets will be forwarded.
Click Add. To delete a static route, highlight a route that was created in the table,
and click Delete.
212
22.4.4 Port Configurations
In the Port Configuration panel under ELAN main menu, you can configure the
specific parameters for each port. Select a specific port by clicking 1 through 8
buttons in the [Port Select] field and enter the port’s configuration menu. After
you configure the port, click Set to apply the settings.
To modify the settings after the port has been set up, de-configure the port by
clicking Deconfig, and then change the settings. The Deconfig All button will
deconfigure all eight ports on the card. When a port is configured, the Status
field will display “Configured”. If it has not been configured or it has
subsequently been deconfigured, the status field will display “Unconfigured”.
Enter a number from 1 to 31. Each port supports from 1 x 64 Kbps to 31 x 64 Kbps.
The first number here represents the time slot number. A single port can support
up to 31 time slots. However, a total of 32 time slots can be allocated amongst the
eight ports. For example, if port 1 occupies two time slots, the rest of the ports can
213
only use 30 time slots (32-2 = 30).
This field is used to set the time interval at which the Keep-Alive message will be
sent. The value ranges 0 to 255 seconds. Zero (0) means no Keep-Alive message
will be sent. In HDLC mode, the Keep-Alive message is sent to inform the remote
end that the port is ready. The remote end should return an acknowledgement
packet upon receiving the Keep-Alive message. The session will then be
established. In PPP mode, the Keep-Alive message is sent at regular intervals to
inform the remote end that the port is operational.
These fields are used to set up the port’s IP address and subnet mask.
!" RIP
Mode: To activate the RIP function of the port, first select Enable in the [Mode]
field under RIP from the ELAN main menu> Common Configurations>
Router>Routing. Then, select Enable in the [Mode] field on this menu.
Poison Reverse: When the Poison Reverse is enabled, the port adopts the split
214
horizon with poison reverse scheme to avoid routing loop problems. If disabled,
the port will use the simple split horizon scheme to solve the problem.
215
Chapter 23 EATU- ADSL Channel Unit
The FM60-EATU is a channel unit of the FM-60 E1 Flexible Multiplexer. This unit
has four ADSL ports for Internet access. With its concentration scheme and TSI
capability, multiple end users’ ADSL traffic can be concentrated onto any time-slot
of an E1 line to increase the bandwidth utilization. At the ISP side, the only
requirement is an unchannelized E1 router/bridge, such as CT-591, to terminate
the traffic.
The FM60-EATU is equipped with two Ethernet LAN ports, which enable for
cascading with other EATU units to accommodate more ADSL services over an E1
line. It also enables interfacing capability with an external router/bridge to allow
for more advanced functions.
With the EATU channel unit, the FM-60 can be enhanced as an integrated access
platform providing not only a leased line, but also ADSL services.
!" Master: Besides the ADSL circuits, this card type can support TSI capability to
concentrate ADSL traffic onto an E1 line.
!" Slave: Provides ADSL circuits only. It has to work with a Master unit to
concentrate its traffic onto an E1 line.
216
23.1 Application
In addition to the typical application (Fig.23-1), the EATU can be used for another
application, illustrated in Figure 23-2. The EATU can be connected to an external
router (e.g., CT-591) through the faceplate UP RJ45 port. Via the router, data
can be transmitted to the data network.
217
23.2 Features
!" Upgrades the FM-60 to a last mile total solution Compatible with other
vendor’s ADSL CPE
218
23.3 Faceplate
The EATU can be cascaded in an FM-60. The Master EATU is able to connect to up
to three slave EATUs. The master EATU is marked M on the faceplate; the Slave
EATU is marked S.
219
Note:
!" *The cross-over cable is for the sample stage only; a straight-through cable
will be used for mass production.
!" A menu-driven interface is provided for software upgrade of the unit. To use
this, connect to a PC via the UP LAN port.
!" The LOS LEDs (P1-P4) will only work after the port link is established. If the
port link doesn’t successfully train with the remote CPE, the LOS LEDs won’t
be operational.
A master EATU accommodates up to three slave units, and their slot position
should follow these rules.
!" The slave EATUs can only be installed in slots higher than the master EATU.
For example, there are two slot numbers for a master unit and a slave unit:
3, and 4. Slot 3 is the slot number to reside the master EATU.
220
!" The slave units must reside in the subsequent three slots next to the master
unit. Any of the three slots can be used for the slave units.
23.5 Configuration
The EATU Configuration page covers two working panels: Common Configuration
and Port Configuration.
221
Common Configuration: displays the information about the software version
and status, and it can be used to configure the card’s common settings. The Set
CU button is used to apply the common settings. The Delete CU button is used
to de-configure the card common settings.
!" Nx64K: This field is used to set up the E1 bandwidth [N= 1-31].
!" Link Protocol: [PPP and HDLC]. This field is used to set up the session link
protocol.
This field is used to set the time interval at which the Keep-Alive message will be
sent. The value ranges from 0 to 255 seconds. Zero (0) means no Keep-Alive
message will be sent. In HDLC mode, the Keep-Alive message is sent to inform
the remote end that the port is ready. Upon receiving the Keep-Alive message,
the remote end should return an acknowledgement packet. The session will then
be established. In PPP mode, the Keep-Alive message is sent at regular intervals
to inform the remote end that the port is operational.
Port Configuration: displays the status of the ports and the slave units that are
connected to the master, and configures the port settings. The port settings
include Detection of Loss of Signal, and Upstream and downstream data rates. If
LOS is enabled, an alarm will be declared if a LOS is detected. The Set button is
used to submit the port settings. The Deconfig button is used to deconfigure
the settings of the port. The Deconfig All button is used to deconfigure all the
ports.
222
23.6 Maintenance
You can test the unit by clicking on the Ping Test button. Three pings will be sent,
and the results will be listed within a few seconds.
223
23.7 Performance
The Performance page allows you collect the statistics for the current 15 minutes
and past four quarters.
224
Appendices
225
26 Major (MJ) E1 SEFS exceeds day threshold
27 Major (MJ) E1 SEFS exceeds quarter threshold
28 Major (MJ) E1 UAS exceeds day threshold
29 Major (MJ) E1 UAS exceeds quarter threshold
30 Major (MJ) E1 CSS exceeds day threshold
31 Major (MJ) E1 CSS exceeds quarter threshold
32 Major (MJ) E1 DM exceeds day threshold
33 Major (MJ) E1 DM exceeds quarter threshold
34 Major (MJ) E1 Control SLIP exceeds day threshold
35 Major (MJ) E1 Control SLIP quarter threshold
226
Appendix B: System Specifications
Common Units
ELIU/ ELIU2- E1 Port number ELIU : 4 ports
Line interface unit ELIU2 : 2 ports
Line type 120 symmetrical, 75
coaxial
Line code HDB3
Frame Basic frame, CRC
multiframe,TS16
multiframe
EMCU-B - Number of HDLC 2
Maintenance and controller
control unit
Static routing Yes
function
Maintenance See "Other
function Specifications" below
ENRS - Network Number of HDLC 32
routing server controller
Static routing Yes
function
EPSU - Power Input power See "Other
supply unit Specifications" below
Redundancy Yes
Channel Units
EE&M - 2W/4W E&M Port number 4
unit
Interface 2-wire 600W, 2-wire
900W, 4-wire 600W
Encoding A-law
Signaling E&M
EEM2 - 2W E&M unit Port number 8
227
Interface 2-wire 600W, 2-wire
900W
Encoding A-law
Signaling E&M
EEM4 - 4W E&M unit Port number 8
Interface 4-wire 600W
Encoding A-law
Signaling E&M
ELTU - Loop Port number 4
terminating unit
Interface 2-wire 900W
Coding A-law
Signaling Loop started
EE0U - G.703 64 Port number 8
Kbps unit
Interface G.703 co-directional
interface
EBRI - ISDN BRITE Port number 2
unit
Interface ISDN U-interface
Line code 2B1Q
Mode LULT or LUNT
Power feeding DC 96 Volts
Embedded EOC (ANSI T1.601) and
operations MP-EOC
channel (TR-TSY-000829)
EBCU - Baseband Port number 4
channel unit
Interface ISDN U-interface
Line code 2B1Q
Data rate 64 or 128Kbps
EDSU - Data service Port number 2
unit
Interface V.35
Data rate N x 64Kbps, N = 1〜31
ESUB - Subrate unit Port number 5
228
Interface V.24
Data rate Async.: 2.4, 4.8, 9.2,
19.2 Kbps
Sync. : 2.4, 4.8, 9.2,
19.2, 64Kbps (64 Kbps
for port #1 only)
Operation mode X.50 or DS0A
(exclusive)
E1 network Line Rate 2.048 Mbps ± 50 ppm
Interface
Line Code HDB3
Pulse Shape ITU-T G.703
Test Load 120 ohms ± 0.5
Impedance resistive, balanced
Nominal Peak 3V
Voltage of a Mark
(Pulse)
Peak Voltage of a ± 0.3V
Space (No Pluse)
Nominal Pulse 244 ns.
Width
Other Synchronization Timing source Loop, external, and
Specifications internal
Internal clock 2.048 MHz ± 32 ppm
generator
External timing 2.048 MHz
input & output
Alarm relay contact Audible/visible,
normally closed/
normally open
Management Local Two RS-232 ports and
interface one 10BaseT Ethernet
port
Remote In-band E1 timeslot (64
Kbps)
229
Power Input power Dual power feed, DC
-42 ~ -56 volts
Maximum power 240 W
consumption
Fuse 5A
Environmental Temperature 0〜50 degrees Celsius
requirements (operating)
Humidity 5%〜95%,
non-condensing
Dimensions 43.2 cm (W) x 25.6 cm (H) x 30 cm (D)
230
Appendix C: Connector Pin Assignments
1 DCD 6 DSR
2 RXD 3 TXD
3 TXD 2 RXD
4 DTR 6 DSR
5 Ground 5 Ground
7 RTS 8 RTS
8 CTS 7 CTS
Pin Function
1 TX+
2 TX-
3 RX+
6 RX-
231
ENRS & ELAN LAN port
Pin Function
1 TX+
2 TX-
3 RX+
6 RX-
232
Pin Function
T1/R1 1 Port 1 TIP1
2 Port 2 TIP1
3 GND
4 Port 3 TIP1
5 Port 4 TIP1
6 Port 1 Ring1
7 Port 2 Ring1
8 Port 3 Ring1
9 Port 4 Ring1
233
EEM2 Access Connector
P1~P4 P5~P8
DB25
Port No. Function Port No. Function
1 1 Tip 5 Tip
2 - - - -
3 1 Ear 5 Ear
4 2 Tip 6 Tip
5 - - - -
6 2 Ear 6 Ear
7 - - - -
8 3 Tip 7 Tip
9 - - - -
10 3 Ear 7 Ear
11 4 Tip 8 Tip
12 - - - -
13 4 Ear 8 Ear
14 1 Ring 5 Ring
15 - - - -
16 1 Mouth 5 Mouth
17 2 Ring 6 Ring
18 - - - -
19 2 Mouth 6 Mouth
20 3 Ring 7 Ring
21 - - - -
22 3 Mouth 7 Mouth
23 4 Ring 8 Ring
24 - - - -
25 4 Mouth 8 Mouth
234
EEM4 Access Connector
P1~P4 P5~P8
DB25
Port No. Function Port No. Function
1 1 Tip 5 Tip
2 1 Tip1 5 Tip1
3 1 Ear 5 Ear
4 2 Tip 6 Tip
5 2 Tip1 6 Tip1
6 2 Ear 6 Ear
7 - - - -
8 3 Tip 7 Tip
9 3 Tip1 7 Tip1
10 3 Ear 7 Ear
11 4 Tip 8 Tip
12 4 Tip1 8 Tip1
13 4 Ear 8 Ear
14 1 Ring 5 Ring
15 1 Ring1 5 Ring1
16 1 Mouth 5 Mouth
17 2 Ring 6 Ring
18 2 Ring1 6 Ring1
19 2 Mouth 6 Mouth
20 3 Ring 7 Ring
21 3 Ring1 7 Ring1
22 3 Mouth 7 Mouth
23 4 Ring 8 Ring
24 4 Ring1 8 Ring1
25 4 Mouth 8 Mouth
235
ELTU Access Connector
T/R
Pin Function
1 Port 1 TIP
2 Port 2 TIP
3 GND
4 Port 3 TIP
5 Port 4 TIP
6 Port 1 Ring
7 Port 2 Ring
8 Port 3 Ring
9 Port 4 Ring
EBRI Connector
T/R
Pin Function
1 Port 1 TIP
2 Port 2 TIP
3 -
4 -
5 -
6 Port 1 Ring
7 Port 2 Ring
8 -
9 -
236
EE0U Access Connector
DB25 T/R T1/R1
1 Port 1 Tip Port 1 Tip1
2 - -
3 Port 2 Tip Port 2 Tip1
4 Port 3 Tip Port 3 Tip1
5 - -
6 Port 4 Tip Port 4 Tip1
7 - -
8 Port 5 Tip Port 5 Tip1
9 - -
10 Port 6 Tip Port 6 Tip1
11 Port 7 Tip Port 7 Tip1
12 - -
13 Port 8 Tip Port 8 Tip1
14 Port 1 Ring Port 1 Ring1
15 - -
16 Port 2 Ring Port 2 Ring1
17 Port 3 Ring Port 3 Ring1
18 - -
19 Port 4 Ring Port 4 Ring1
20 Port 5 Ring Port 5 Ring1
21 - -
22 Port 6 Ring Port 6 Ring1
23 Port 7 Ring Port 7 Ring1
24 - -
25 Port 8 Ring Port 8 Ring1
237
EDSU Access Connector
V35
Function Source
Interface
1 Protective Ground --
2 Transmit Data (A) DTE
3 Receive Data (A) EDSU
4 Request to Send (A) DTE
5 Clear to Send (A) EDSU
6 Data Set Ready (A) EDSU
7 Signal Ground --
8 Received Line Signal Detector (A) EDSU
9 Receive Clock (B) EDSU
10 -- --
11 Transmit Clock (B)– DTE DTE
12 Transmit Clock (B)– DCE EDSU
13 -- --
14 Transmit Data (B) DTE
15 Transmit Clock (A)– DCE EDSU
16 Receive Data (B) EDSU
17 Receive Clock (A) EDSU
18 -- --
19 -- --
20 -- --
21 -- --
22 -- --
23 -- --
24 Transmit Clock (A)– DTE DTE
25 -- --
238
EBCU Access Connector
T/R
Pin Function
1 Port 1 TIP
2 Port 2 TIP
3 -
4 Port 3 TIP
5 Port 4 TIP
6 Port 1 Ring
7 Port 2 Ring
8 Port 3 Ring
9 Port 4 Ring
Asynchronous Synchronous
239
Appendix D: Cable Specifications
240
Appendix E: Frequently Asked Questions
Q1. Unable to access the FM-60 via the CID software over PPP
Make sure both your modem and the FM-60 are set to the same rate. The factory
default setting of the FM-60 is 38.4 Kbps. You can modify the rate to 19.2 Kbps
via the CID.
The default setting of the CID port IP address is 192.168.1.10. If it was changes,
use the new IP address to log on.
The following is an example on using the default IP address to access the FM-60.
STEP 3: Make sure you have reset FM-60 after changing the baud rate of the CID
port.
STEP 4: You must manually assign an IP to your PC that runs the CID software,
and make sure it is set to the same network segment as the FM-60 CID
port (the default IP of FM-60’s CID port is 192.168.1.10). The following
is an example on how to modify your TCP/IP for the PPP session on
241
Windows 98. For other operating systems, the procedures may differ.
242
!" Click the Server Type tab and click the TCP/IP Settings… button.
!" Click Specify an IP address and type the IP address of your PC. Click OK to
complete the setting.
243