Advanced Transformer Protection, Control Key Features
and Condition Monitoring High-speed transformer differential
protection
Transformers are high capital cost assets in electrical power systems. Internal faults are a Simple settings – wizard requires only
risk for all transformers, with short-circuits dissipating the highest localised energy. Unless nameplate data
cleared quickly, the possibility of rewinding will diminish and core damage may become Novel CT saturation and no gap
irreparable. detection techniques enhances the low
set differential element operating time
The MiCOM Agile P642, P643 and P645 address all these issues - preserving service life and
offering fast protection for transformer faults. A transient bias technique has been Transient bias algorithm enhances relay
included, enhancing relay stability and CT requirements. CT saturation and no gap stability and reduces CT requirements
detection techniques have been included to improve the low set differential element High and low impedance
operating time during CT saturation where the second harmonic blocking might be Restricted Earth Fault (REF) boosts
asserted. An external fault detection algorithm has been incorporated to prevent the CT trip sensitivity
saturation and no gap detection from affecting the second harmonic blocking when there
is an external fault. Voltage, frequency, thermal and
overfluxing elements, CT, VT, trip circuit
Hosted on an advanced IED platform, the P64x incorporates differential, REF, thermal, and and self- supervision
overfluxing protection, plus backup protection for uncleared external faults. Model variants Patented CT supervision ensures no
cover two and three-winding transformers (including auto-transformers), with up to five spurious trip for CT or wiring failures
sets of 3-phase CT inputs. Large CT counts are common in ring bus/mesh corner
Integrated backup overcurrent per
applications, where the P64x summate currents to create each total winding current,
winding or CT input
easing application of backup protection. Backup overcurrent can be directionalised, where
the user includes the optional 3-phase VT input or 2-phase VT input in their chosen model. Fast reset (less than 1 cycle) circuit
breaker failure element
Customer Benefits Readily interfaces with multiple
automation protocols, including
Universal IED for all transformer configurations IEC 61850 with optional redundancy
Protection, control, monitoring, measurements and recording in one device. including IEC 62439 PRP, RSTP and
software based Ethernet failover
Backup and logging of through faults
(Hot Standby)
Simple to configure, set, and commission
Programmable function keys
Programmable Scheme Logic (PSL) allows easy customization of the protection and
control functions
IEC 61850-9-2 process bus ready & Cyber Security
imagination at work
P642, P643, P645 Transformer Protection
Application
The M iC O M Agile P642 is intended for two- As well as transformer protection, the
winding transformer applications, with one P64x range may be applied to other unit
set of 3 - phase C Ts per winding. The P643 applications, such as reactors and
covers up to 3 bias inputs (three C T sets) - motors. The P64x series is supplied with
either a three- winding application, or two- a full suite of protection and control
winding with dual C Ts on one side. W here functions as standard.
4 or 5 feeding connections to the protected
transformer exist, the P645 offers five bias The configuration column of the menu is
input sets. All models have a single- phase used to control which functions the user
V T input, mainly for overfluxing protection. requires in the intended application, and
An additional single phase V T input can be which may be disabled. Disabled
ordered in the P642 to provide N PS over functions are completely removed from
voltage and directional functions to the menu, to simplify settings.
some extent.
Differential elements have an inbuilt
The P643 and P645 allow an additional 3 - configuration wizard to avoid
phase V T input to be connected. This settings errors.
allows overcurrent back up to be
directionalized, and expands the
measurement and recording analog
channels available. The P643 and P645 can
be configured to protect transformers for
differential protection and the unused C T
inputs can be used to protect other
circuits over current protection of
auxiliary transformers.
2 GEGridSolutions.com
P642, P643, P645 Transformer Protection
Functional Overview
GEGridSolutions.com 3
P642, P643, P645 Transformer Protection
Functional Overview
1. The three-phase VT input is optional. The additional single-phase VT input in P643/5 is optional.
2. The 27, 59, 59N functions require the three-phase VT input.
3. The frequency measurement required by the 81 function is obtained from any analogue signal, but the voltage signals have priority over the current signals.
FIGURE 1: System Overview of the P64x series – example 3-winding, 4 bias application)
4 GEGridSolutions.com
P642, P643, P645 Transformer Protection
Main Protection
87T Transformer Differential The CT saturation and no gap detection R E F : R estricted E arth (G rou nd ) F au lt
distinguish between magnetising inrush
The algorithm has a triple slope and saturated current waveforms. An Restricted earth fault protection is
percentage bias restraint, as shown in external fault detection technique has included to cover a larger percentage of
Figure 2. An internal fault will generate been included to prevent the CT saturation the transformer windings than might be
differential current. The bias current is and no gap detection from affecting the possible with the main differential
that which merely flows through the second harmonic blocking during external elements. A separate element per winding
protected unit, as a load or through-fed faults, thus maintaining stability. is provided (P642: HV and LV).
external fault. The initial characteristic is
flat, for ease of commissioning, rising then Energization of a transformer causes P643/P645: HV, LV, and if required, the TV
to bias slope (k1). K1 is a low slope for magnetising inrush current to flow in one tertiary too). Low impedance and high
sensitivity to faults whilst allowing for winding only and the differential elements impedance REF for conventional
mismatch when the power transformer is may need stabilising whilst the inrush transformers and autotransformers
at the limits of its tapchanger range, in persists (see Figure 3). A proven second are available.
addition to any current transformer ratio harmonic current ratio scheme is used.
errors. At currents above rated, extra The differential protection may also be Figure 4 shows a typical restricted earth
errors may be gradually introduced as a restrained when the transformer is fault application. B iased REF is used, to
result of CT saturation, hence the bias overfluxed so that an instantaneous trip is avoid the need for any stabilising resistor
slope increases to k2. not issued for transient overfluxing. or varistor/ metrosil. REF elements operate
O verfluxing restraint is conditioned by the independently of inrush detection,
The P64x incorporates a transient bias percentage of fifth harmonic current potentially offering faster tripping for low
characteristic that increases dynamically present. Two high set instantaneous or moderate fault currents, in addition to
the operating current threshold during differential elements, not subject to enhanced sensitivity. Low impedance REF
external faults, thus enhancing harmonic restraint, are provided to ensure element stability is enhanced by transient
differential element stability and CT rapid clearance of high current faults. bias algorithm.
requirements. To improve the low set
differential element operating times, the The differential protection setting
P64x has a CT saturation and no gap configuration utility requires only known
detection technique that prevents the data – that which resides on the
second harmonic blocking from affecting transformer rating plate, the CT rating
the low set differential element. As a plate and information on any in-zone
result, fast operating times are achieved earthing transformer.
during CT saturation and fault levels
below high set one and two elements.
GEGridSolutions.com 5
P642, P643, P645 Transformer Protection
6 GEGridSolutions.com
P642, P643, P645 Transformer Protection
GEGridSolutions.com 7
Fault Records Communication to Remote Operators
Indication of the faulted phase and Substation Automation
Protection operation Two auxiliary communication ports are available; a rear port
Active setting group providing remote communications and a front port providing local
communications.
Relay and CB operating time
Pre-fault and fault currents An additional, second rear port can be ordered as an option. Any
Bias and differential currents of the following rear port protocols can be chosen at the time of
ordering: Courier/K-Bus, MODBUS, IEC 60870-5- 103, DNP3.0, or
Disturbance Records IEC 61850. An Ethernet port is available as an option for IEC61850
or DNP3.0. Px4x devices can be enhanced with an optional
High performance waveform records contain all CT and VT redundant Ethernet board. The redundancy is managed by the
input channels, plus up to 32 digital states, extracted in market's fastest recovery time protocols: IEC 62439-3 PRP and
COMTRADE format. HSR allowing bumpless redundancy and RSTP (Rapid Spanning
Tree) protocol, offering multi-vendor interoperability. The
IEC 61850-9-2 Process Bus Interface redundant Ethernet board supports either modulated or
An optional process bus interface is available, allowing the relay to demodulated IRIG-B and the SNTP protocol for time
receive current and voltage sampled data from non-conventional synchronisation. The redundant Ethernet board also has a
instrument transformers such as optical and Rogowski devices. In watchdog relay contact and an SNMP interface to alarm in case of
other digital substation architectures, the -9-2 data is generated a failure.
by merging units in the yard, which digitize conventional 1 A/5 A
and 100/120 V secondaries, for safer and more economical cross- Second Rear Courier Port
site communication to IEDs by fibre optic. Grid Solutions' -9-2 The optional second port is designed typically for dialup modem
implementation has been designed to be especially resilient and access by protection engineers / operators, when the main port is
reliable in the presence of "noise", such as latency, jitter or reserved for SCADA traffic.
missing/suspect data.
MiCOM P40 Agile
Plant Supervision
GE’s philosophy is one of continuous improvement in our products
Trip Circuit Supervision and solutions. Our emphasis on communication in MiCOM has
become a focus which secures leadership in the digital substation.
Supervision of the trip circuit can be implemented using
To mark this phase of evolution, the brand “ P40 Agile” is applied to
optocoupled inputs and the programmable scheme logic.
the range. P40 Agile is a mark of performance and quality, proudly
available from GE, and only from GE.
Analog (Current Loop) Inputs and Outputs (CLIO)
Four inputs are provided for transducers with ranges of 0-1 mA,
0-10 mA, 0-20 mA or 4-20 mA. Associated with each input there
are two time delayed protection stages, one for alarm and one for
trip. Each stage can be set for 'Over' or 'Under' operation.
GEGridSolutions.com
For more information please contact
IEC is a registered trademark of Commission Electrotechnique Internationale. IEEE is a registered
GE Grid Solutions trademark of the Institute of Electrical Electronics Engineers, Inc.
Phone: +44 (0) 1785 250 070 Grid-GA-L3-P64x-0688-2016_12-EN. © Copyright 2016, General Electric Company.
All Rights Reserved.
imagination at work