Manual: DES-1250G

Download as pdf or txt
Download as pdf or txt
You are on page 1of 25

D-Link™ DES-1250G

WebSmart 48-Port 10/100Mbps+2-Port Combo 10/100/1000Mbps


Copper/SFP(Mini GBIC) Gigabit Switch

Manual

First Edition

Building Networks for People

RECYCLABLE

i
TABLE OF CONTENT
About This Guide...................................................................................................................................................................................... 1
Purpose ................................................................................................................................................................................................. 1
Terms/Usage ......................................................................................................................................................................................... 1
Introduction............................................................................................................................................................................................... 3
Gigabit Ethernet Technology ................................................................................................................................................................ 3
Fast Ethernet Technology ..................................................................................................................................................................... 3
Switching Technology .......................................................................................................................................................................... 3
VLAN (Virtual Local Area Network)................................................................................................................................................... 4
Features................................................................................................................................................................................................. 5
Unpacking and Installation ....................................................................................................................................................................... 9
Unpacking............................................................................................................................................................................................. 9
Installation ............................................................................................................................................................................................ 9
Rack Mounting ..................................................................................................................................................................................... 9
Connecting Network Cable................................................................................................................................................................... 9
AC Power............................................................................................................................................................................................ 10
Identifying External Components ........................................................................................................................................................... 13
Front Panel.......................................................................................................................................................................................... 13
Rear Panel ........................................................................................................................................................................................... 13
Understanding LED Indicators ............................................................................................................................................................... 14
Power and System LEDs .................................................................................................................................................................... 14
Ports 1~48 10/100M Status LEDs....................................................................................................................................................... 14
Ports 49~50 Gigabit Status LEDs ....................................................................................................................................................... 14
Ports 49~ 50 mini-GBIC Status LEDs ................................................................................................................................................ 15
Configuration .......................................................................................................................................................................................... 19
Installing the Web Management Utility.............................................................................................................................................. 19
Discovery List..................................................................................................................................................................................... 19
Monitor List ........................................................................................................................................................................................ 20
Device Setting..................................................................................................................................................................................... 20
Toolbar................................................................................................................................................................................................ 21
Configuring the Switch ....................................................................................................................................................................... 22
Login................................................................................................................................................................................................... 22
Setup Menu ......................................................................................................................................................................................... 23
Configuring Setup Setting................................................................................................................................................................... 23
Port Settings.................................................................................................................................................................................... 23
VLAN Settings (Virtual Local Area Network) ............................................................................................................................... 24
Trunk Setting .................................................................................................................................................................................. 25
Device Status .................................................................................................................................................................................. 25
Statistic............................................................................................................................................................................................ 25
System Setting ................................................................................................................................................................................ 26
Trap Setting..................................................................................................................................................................................... 27
Set Password ................................................................................................................................................................................... 27
Backup Setting ................................................................................................................................................................................ 27
Reset Setting ................................................................................................................................................................................... 27
Logout................................................................................................................................................................................................. 28
Technical Specifications ......................................................................................................................................................................... 41

ii
ABOUT THIS GUIDE
Congratulations on your purchase of the Web Smart 48+2G-Port 10/100/1000Mbps/SFP Switch. This device integrates 1000Mbps
Gigabit Ethernet, 100Mbps Fast Ethernet, and 10Mbps Ethernet network capabilities in a highly flexible package.

Purpose
This guide discusses how to install your Web Smart 48+2G-Port 10/100/1000Mbps/SFP Switch.

Terms/Usage
In this guide, the term “Switch” (first letter upper case) refers to your Web Smart 48+2G-Port 10/100/1000Mbps Switch, and “switch”
(first letter lower case) refers to other Ethernet switches.

1
INTRODUCTION
This chapter describes the features of the Web-Smart 48+2G-Port 10/100/1000Mbps/SFP Switch and some background information
about Ethernet/Fast Ethernet/Gigabit Ethernet switching technology.

Gigabit Ethernet Technology


Gigabit Ethernet is an extension of IEEE 802.3 Ethernet utilizing the same packet structure, format, and support for CSMA/CD
protocol, full-duplex, flow control, and management objects, but with a tenfold increase in theoretical throughput over 100-Mbps Fast
Ethernet and a hundredfold increase over 10-Mbps Ethernet. Since it is compatible with all 10-Mbps and 100-Mbps Ethernet
environments, Gigabit Ethernet provides a straightforward upgrade without wasting a company’s existing investment in hardware,
software, and trained personnel.
The increased speed and extra bandwidth offered by Gigabit Ethernet are essential to coping with the network bottlenecks that
frequently develop as computers and their busses get faster and more users use applications that generate more traffic. Upgrading key
components, such as your backbone and servers to Gigabit Ethernet can greatly improve network response times as well as
significantly speed up the traffic between your subnets.
Gigabit Ethernet enables fast optical fiber connections to support video conferencing, complex imaging, and similar data-intensive
applications. Likewise, since data transfers occur 10 times faster than Fast Ethernet, servers outfitted with Gigabit Ethernet NIC’s are
able to perform 10 times the number of operations in the same amount of time.
In addition, the phenomenal bandwidth delivered by Gigabit Ethernet is the most cost-effective method to take advantage of today and
tomorrow’s rapidly improving switching and routing internetworking technologies. With expected advances in the coming years in
silicon technology and digital signal processing that will enable Gigabit Ethernet to eventually operate over unshielded twisted-pair
(UTP) cabling, outfitting your network with a powerful 1000-Mbps-capable backbone/server connection creates a flexible foundation
for the next generation of network technology products.

Fast Ethernet Technology


The growing importance of LANs and the increasing complexity of desktop computing applications are fueling the need for high
performance networks. A number of high-speed LAN technologies have been proposed to provide greater bandwidth and improve
client/server response times. Among them, 100BASE-T (Fast Ethernet) provides a non-disruptive, smooth evolution from the current
10BASE-T technology. The non-disruptive and smooth evolution nature, and the dominating potential market base, virtually
guarantees cost-effective and high performance Fast Ethernet solutions.
100Mbps Fast Ethernet is a standard specified by the IEEE 802.3 LAN committee. It is an extension of the 10Mbps Ethernet standard
with the ability to transmit and receive data at 100Mbps, while maintaining the CSMA/CD Ethernet protocol. Since the 100Mbps Fast
Ethernet is compatible with all other 10Mbps Ethernet environments, it provides a straightforward upgrade and takes advantage of the
existing investment in hardware, software, and personnel training.

Switching Technology
Another approach to pushing beyond the limits of Ethernet technology is the development of switching technology. A switch bridges
Ethernet packets at the MAC address level of the Ethernet protocol transmitting among connected Ethernet or Fast Ethernet LAN
segments.
Switching is a cost-effective way of increasing the total network capacity available to users on a local area network. A switch
increases capacity and decreases network loading by dividing a local area network into different segments, which do not compete with
each other for network transmission capacity.
The switch acts as a high-speed selective bridge between the individual segments. The switch, without interfering with any other
segments, automatically forwards traffic that needs to go from one segment to another. By doing this the total network capacity is
multiplied, while still maintaining the same network cabling and adapter cards.
Switching LAN technology is a marked improvement over the previous generation of network bridges, which were characterized by
higher latencies. Routers have also been used to segment local area networks, but the cost of a router, the setup and maintenance
required make routers relatively impractical. Today switches are an ideal solution to most kinds of local area network congestion
problems.

3
VLAN (Virtual Local Area Network)
A VLAN is a group of end-stations that are not constrained by their physical location and can communicate as if a common broadcast
domain, a LAN. The primary utility of using VLAN is to reduce latency and the need for routers, by using faster switching instead.
Other VLAN utility includes:
Security, Security is increased with the reduction of opportunity in eavesdropping on a broadcast network because data will be
switched to only those confidential users within the VLAN.
Cost Reduction, VLANs can be used to create multiple broadcast domains, thus eliminating the need of expensive routers.
Port-based (or port-group) VLAN is the common method of implementing a VLAN, and is the one supplied in the Switch.

4
Features
48×10/100Mbps Auto-negotiation Fast Ethernet RJ-45 ports
2×10/100/1000Mbps Auto-negotiation Gigabit RJ-45 ports
2×mini-GBIC/SFP ports, share with the 2 gigabit copper ports
All RJ-45 ports support auto MDI/MDIX, so there is no need to use cross-over cables or an up-link port
Half-duplex transfer mode for 10/100Mbps RJ45 ports
Full-duplex transfer mode for 10/100/1000Mbps RJ45 ports
Store-and-Forward switching scheme capability to support rate adaptation and ensure data integrity
Up to 4K unicast addresses entities per device, self-learning, and table aging
1536KBytes packet buffer
Supports IEEE 802.3x flow control for full-duplex mode ports
Supports Back-pressure flow control for half-duplex mode ports
Supports 802.1Q VLAN
Supports Port-base QoS
Supports seven Port-base Trunking group
Supports Port Mirroring
Supports Port-setting for Speed/Disable, Flow control
Easy configuration via Web Browser
Easy setting via Web Management Utility
Standard 19” Rack-mount size

5
UNPACKING AND INSTALLATION
This chapter provides unpacking and installation information for the Switch.

Unpacking
Open the shipping cartons of the Switch and carefully unpacks its contents. The carton should contain the following items:
One Web Smart 48+2G-Port 10/100/1000Mbps/SFP Switch
One AC power cord, suitable for your area’s electrical power connections
Four rubber feet to be used for shock cushioning
Screws and two mounting brackets
CD-Rom with Web Management Utility and User’s Guide
If any item is found missing or damaged, please contact your local reseller for replacement.

Installation
The site where you install the hub stack may greatly affect its performance. When installing, consider the following pointers:
Install the Switch in a fairly cool and dry place. See Technical Specifications for the acceptable temperature and humidity operating
ranges.
Install the Switch in a site free from strong electromagnetic field generators (such as motors), vibration, dust, and direct exposure to
sunlight.
Leave at least 10cm (about 4 inches) of space at the front and rear of the hub for ventilation.
Install the Switch on a sturdy, level surface that can support its weight, or in an EIA standard-size equipment rack. For information on
rack installation, see the next section, titled Rack Mounting.
When installing the Switch on a level surface, attach the rubber feet to the bottom of each device. The rubber feet cushion the hub and
protect the hub case from scratching.

Rack Mounting
The Switch can be mounted in an EIA standard-size, 19-inch rack, which can be placed in a wiring closet with other equipment.
Attach the mounting brackets at the Switch’s front panel (one on each side), and secure them with the provided screws.

Figure 1. Combine the Switch with the provided screws


Then, use screws provided with the equipment rack to mount each Switch in the rack.

Figure 2. Mount the Switch in the rack

Connecting Network Cable


The Switch supports 10Mbps Ethernet or 100Mbps Fast Ethernet and it runs both in half- and full- duplex mode using two pairs of
Category 5 cables.
The Switch also supports 2-Ports Gigabit Ethernet that runs in Auto-negotiation mode and 10Mbps Ethernet or 100Mbps Fast
Ethernet that runs both in half- and full- duplex mode and 1000Mbps Gigabit Ethernet runs in full-duplex mode using four pairs of
Category 5 Cables.
These RJ-45 ports are Auto-MDI type port. The Switch can auto transform to MDI-II or MDI-X type, so you can just make an easy
connection that without worrying if you are using a standard or crossover RJ45 cable.
There are additional two mini-GBIC ports for optional mini-GBIC/SFP modules.

9
IDENTIFYING EXTERNAL COMPONENTS
This chapter describes the front panel, rear panel, and LED indicators of the Switch.

Front Panel
The figure below shows the front panels of the Switch.
LED Indicators Mini GBIC Ports
┌──────────────────────────────────────────────────────────┐ ┌────┐

└─────────────────────────────────────────┘ └───┘
10/100 Base-TX 1000 Base-T
Twisted-Pair Ports Twisted Pair Ports

Figure 3. Front panel of 48+2G-port Gigabit Ethernet Switch


LED Indicator:
Comprehensive LED indicators display the status of the Switch and the network (see the LED Indicators chapter below).
Fast Ethernet Ports (Port 1~48):
These ports support network speeds of either 10Mbps or 100Mbps, and can operate in half- and full- duplex transfer modes. These
ports also supports automatic MDI/MDIX crossover detection function gives true “plug and play” capability, just need to plug-in the
network cable to the hub directly and don’t care if the end node is NIC (Network Interface Card) or switch and hub.
Gigabit Ethernet Ports (Port 49~50):
The Switch is equipped with two Gigabit twisted pair ports, supported auto negotiable 10/100/1000Mbps and auto MDI/MDIX
crossover detection function. These two ports can operate in half-duplex mode for 10/100Mbps and full-duplex mode for
10/100/1000Mbps.
Note: When the port was set to “Forced Mode”, the Auto MDI/MDIX will be disabled.

mini-GBIC (SFP) Ports (Port 49~50):


The Switch is equipped with two mini-GBIC ports, supported optional 1000BASE-SX/LX mini-GBIC transceivers.
Port 49 and 50 are the same ports with the mini-GBIC no.49 and 50 ports, when the mini-GBIC transceiver is plugged in, the
device will activate mini-GBIC, and the RJ-45 port will be disabled.
Reset:
The Reset button is to reset all settings back to factory defaults.
Note: Be sure that you record the setting of your device, or else all settings will be erased when pressing the “Reset” button.

Rear Panel

Figure 4. Rear panel of the Switch


AC Power Connector:
This is a three-pronged connector that supports the power cord. Plug in the female connector of the provided power cord into this
connector, and the male into a power outlet. Supported input voltages range from 100-240V AC at 50-60Hz.

13
UNDERSTANDING LED INDICATORS
The front panel LEDs provide instant status feedback, and help monitor and troubleshoot when needed.

Figure 5. LED indicators of the Switch

Power and System LEDs


POWER: Power Indicator
On : When the Power LED lights on, the Switch is receiving power.

Off : When the Power turns off or the power cord has improper connection.

CPU: Management Indicator


Blinking : When the CPU is working, the System LED is blinking.

On/Off : The CPU is not working.

Ports 1~48 10/100M Status LEDs


Link/ACT: Link/Activity
On : When the Link/ACT LED lights on, the respective port is successfully
connected to an Ethernet network.

Blinking : When the Link/ACT LED is blinking, the port is transmitting or


receiving data on the Ethernet network.

Off : No link.

Ports 49~50 Gigabit Status LEDs


Link/ACT: Link/Activity
On : When the Link/ACT LED lights on, the respective port is successfully
connected to an Ethernet network.

Blinking : When the Link/ACT LED is blinking, the port is transmitting or


receiving data on the Ethernet network.

Off : No link.

SPEED:
On : When the green light is on, the respective port is connected to a
(Green) 1000Mbps Gigabit Ethernet network.

On When the Amber light is on, the respective port is connected to a


(Amber) 100Mbps Fast Ethernet network.

Off : When the respective port is connected to a 10Mbps Ethernet or No link.

14
Ports 49~ 50 mini-GBIC Status LEDs
Link/ACT: Link/Activity
On : When the mini-GBIC transceiver is installed and connected to a
network, the Link/ACT LED lights on.

Blinking : When the LED is blinking, the mini-GBIC module is receiving data on a
network.

Off : No link.

15
CONFIGURATION
Through the Web Browser you can configure Switch settings such as VLAN, Trunking, QoS… etc.
With the attached Web Management Utility, you can easily discover all Web Management Switches, assign the IP Address, change
the password, and upgrade new firmware.

Installing the Web Management Utility


The following provides instructions guiding you through the installation of the Web Management utility.
1. Insert the Utility CD in the CD-ROM Drive.
2. From the Start menu on the Windows desktop, choose Run.
3. In the Run dialog box, type D:\Web Management Utility\setup.exe (D:\ depends where your CD-Rom drive is located) and click
OK.
4. Follow the on-screen instructions to install the utility.
5. Upon completion, go to Program Files -> D-Link_web_management_utility and execute the Web Management utility. (Figure
6.)

Figure 6. Web Management Utility


The Web Management Utility is divided into four parts: Discovery List, Monitor List, Device Setting, and Toolbar function. For
detailed instruction, follow the section below.

Discovery List
This is the list where you can discover all the Web management devices in the entire network.
By pressing the “Discovery” button, you can list all the Web Management devices in the discovery list.
Double click or press the “Add to monitor list” button to select a device from the Discovery List to the Monitor List.

System word definitions in the Discovery List:


MAC Address: Shows the device MAC Address.
IP Address: Shows the current IP address of the device.
Protocol version: Shows the version of the Utility protocol.
Product Name: Shows the device product name.
System Name: Shows the appointed device system name.
Location: Shows where the device is located.
Trap IP: Shows the IP where the Trap is to be sent.

19
Subnet Mask: Shows the Subnet Mask set of the device.
Gateway: Shows the Gateway set of the device.

Monitor List
All the Web Smart Devices in the Monitor List can be monitored; you can also receive traps and show the status of the device.
System word definitions in the Monitor List:
S: Shows the system symbol of the Web-Smart device, represents a device system that is not alive.
IP Address: Shows the current IP address of the device.
MAC Address: Shows the device MAC Address.
Protocol version: Shows the version of the Utility protocol.
Product Name: Shows the device product name.
System Name: Shows the appointed device system name.
Location: Shows where the device is located.
Trap IP: Shows the IP where the Trap is to be sent.
Subnet Mask: Shows the Subnet Mask set of the device.
Gateway: Shows the Gateway set of the device.
View Trap: The Trap function can receive the events that occur from the Web Management Switch in the Monitor List.
There is a light indicator behind the “View Trap” button, when the light is green, it means that no trap has been transmitted, and when
it is red, it means that a new trap has been transmitted; this is to remind us to view the trap. (Figure 7)

Figure 7.
When the “View Trap” button is clicked, a Trap Information window will pop up; it will display the trap information including the
Symbol, Time, Device IP, and the Event occured. (Figure 8)
The symbol “ ” represents the trap signal, this symbol will disappear after you review and click on the event record.

Figure 8.
Note: In order to receive Trap information, the Switch has to be configured with the Trap IP and Trap Events settings in the Web browser, which are
available in the Trap Setting Menu (see Page 40 for detail).

Add Item: To add a device to the Monitor List manually, enter the IP Address of the device that you want to monitor.
Delete Item: To delete the device in the Monitor List.

Device Setting
You can set the device by using the function key in the Device Setting Dialog box.
Configuration Setting: In this Configuration Setting, you can set the IP Address, Subnet Mask, Gateway, Set Trap to (Trap IP
Address), System name, and Location.
Select the device in the Discovery list or Monitor List and press this button. The Configuration Setting window will pop up as seen in
Figure 9. After filling in the data that you want to change, you must fill in the password and press the “Set” button to process the data
change immediately.

20
The factory default password is "admin."
Figure 9. Configuration Setting
Password Change: You can use this Password Change when you need to change the password, fill in the required passwords in the
dialog box and press the “Set” button to process the password change immediately.

Figure 10. Password Change


Firmware Upgrade: When the device has a new function, there will be a new firmware to update the device; use this function to
upgrade the firmware.

Figure 11.
Web Access: Double click the device in the Monitor List or select a device in the Monitor List and press the “Web Access” button to
access the device in Web browser.

Toolbar
The toolbar in the Web Management Utility has four main tabs: File, View, Options, and Help.
In the “File TAB”, there is Monitor Save, Monitor Save As, Monitor Load, and Exit.
Monitor Save: To record the setting of the Monitor List to the default settings. The next time you open the Web Management
Utility, it will automatically load the default recorded setting.
Monitor Save As: To record the setting of the Monitor List to anappointed filename and file path.
Monitor Load: To manually load the setting file of the Monitor List.
Exit: To exit the Web Management Utility.
In the “View TAB”, there is the view log and clear log function. These functions will help you display trap settings.
View Log: To show the event of the Web Management Utility and the device.

21
Clear Log: To clear the log.
In the “Option TAB”, there is the Refresh Time function; this function helps you to refresh the time for monitoring the device.
Choose 15 secs, 30 secs, 1 min, 2 min, and 5 min to select the time for monitoring.
In the “Help TAB”, there is About function, it will show out the version of the Web Management Utility.

Configuring the Switch


The 48+2G-Port 10/100/1000Mbps Gigabit Ethernet Web Smart Switch has a Web GUI interface for smart switch configuration. The
Switch can be configured through the Web Browser. A network administrator can manage, control and monitor the Switch from the
local LAN. This section indicates how to configure the Switch to enable its smart functions including:
Port Setting (Speed/Disable, Duplex mode, Flow Control, and Port base QoS)
Virtual LAN Group setting (VLAN)
Port trunking
Port mirroring
System Setting
Device status and Statistic

Login
Before you configure this device, note that when the Web Smart Switch is configured through an Ethernet connection, the manager
PC must be set on same the IP network. For example, when the default network address of the default IP address of the Web Smart
Switch is 192.168.0.1, then the manager PC should be set at 192.168.0.x (where x is a number between 2 and 254), and the default
subnet mask is 255.255.255.0.

Open Internet Explorer 5.0 or above Web browser.


Enter IP address http://192.168.0.1 (the factory-default IP address setting) into the address location.

Figure 12.
Or through the Web Management Utility, you do not need to remember the IP Address. Select the device shown in the Monitor List of
the Web Management Utility to settle the device on the Web Browser.
When the following dialog page appears, enter the default password "admin" and press Login to enter the main configuration
window.

Figure 13.
After entering the password, the main page comes up; the screen will display the device status.

22
Figure 14. Device Status

Setup Menu
When the main page appears, find the Setup menu on the left side of the screen (Figure 15). Click on the setup item that you want to
configure. There are eleven options: Port Settings, VLAN Settings, Trunk Setting, Device Status, Statistic, System Settings, Trap
Setting, Password Setting, Backup Setting, and Reset Setting as shown in the Main Menu screen.

Figure 15. Setup menu

Configuring Setup Setting


There are four items, including Port Settings, VLAN Settings, and Trunk Settings in the Setup menu.
Port Settings
The Port Settings menu (Figure 16) will display each port’s status, press the ID parameter to set each port’s Speed, Flow Control, and
QoS priority. When you need to renew the posted information, press the “Refresh” button.
The Link Status in the screen will display the connection speed and duplex mode; this dialog box will display down when the port is
disconnected.

23
Figure 16. Port Configuration
To change the port setting, click on the ID parameter to enter the selected port to configure its Speed/Disable, Flow control, and QoS
setting.

Figure 17.
Speed:
This setting has six modes—1000M Full, 100M Full, 100M Half, 10M Full, 10M Half, Auto, and Disable—for speed or port
disable selections.
Note: If the speed set to 100M full mode or 10M full mode, flow control should have the fixed setting set to disable.

Flow Control:
This setting determines whether or not the Switch will be handling flow control. Set FlowCtrl to Enable for avoiding data transfer
overflow. Or if it is set to Disable, there is either no flow control or other hardware/software management.
When the port is set to forced mode, then the flow control will automatically set to Disable.
Note: Sending packets between two groups may cause packet loss.

QoS:
In some ports that need to have a high priority to manage the data transfer, QoS should be changed. Set the port’s QoS to high to
determine that the port will always transfer its data first.

VLAN Settings (Virtual Local Area Network)


A VLAN is a collection of switch ports that make up a single broadcast domain. You can configure a VLAN for a single
switch, or for multiple switches. When you create a VLAN, you can control traffic flow and ease the administration of
moves, adds, and changes on the network, by eliminating the need to change physical cabling.
On VLAN settings, there are two main settings, VID Table Setting and Port VLAN Setting.
VID: Select the VID group that you set.
When you select VID Table Setting, press “Add new VID” to create new VID group, from port 01 ~ port 16. Select Untag Port, Tag
Port, or Not Member for each port. To save the VID group, press the “Apply” button. To remove the selected VID group, select the

24
VID group and press the “Remove the VID” button. To modify the VID group setting, select the VID group and change the setting,
and press the “Apply” button to save the settings.

Figure 18.
When you select Port VLAN setting, fill in each port’s PVID value between 1 and 4094.

Figure 19.
Trunk Setting
The Trunk function enables the Switch to cascade two devices with a double times bandwidth (up to 4000Mbps in full-duplex mode).
There are seven groups for trunk setting, each group has a fixed setting to choose from, Group 1~Group 6 for 10/100Mbps setting and
Group 7 for 10/100/1000Mbps setting

Figure 22. Trunk Settings


Be sure that the selected trunk setting port connects to the device with a same VLAN group.
Device Status
Click on the “Status” button to present the device status on this screen, it will show the System Status, Port Status, VLAN Status, and
Trunk Status.
Press “Refresh” when you need to renew the posted information.
Statistic
The Statistic Menu screen will show the status of each port packet count.

25
Figure 23. Statistic

For detailed packet information, click on the ID parameter as seen Figure 24.

Figure 24.
System Setting
The System Setting includes the System name, Location name, Login Timeout, IP Address, Subnet Mask, and Gateway. Through the
Web Management Utility, you can easily recognize the device by using the System Name and the Location Name.
The Login Timeout is used to set the idle time-out for security purposes. When there is no action while running the Web Smart Utility
and the time is up, you must re-login to Web Smart Utility before you set the Utility.

Fill in the IP Address, Subnet Mask, and Gateway for the device.

26
Figure 25.
Trap Setting
The Trap Setting enables the device to monitor the Trap through the Web Management Utility. Set the Trap IP Address of the
manager where the trap is to be sent.

Figure 26. Trap Setting

System Events: Monitoring the system’s trap.


Device Bootup: A trap when booting up the system.
Illegal Login: A trap when there is an incorrect password login, and it will record from where the IP logins in.
Fiber Port Events: Monitoring the Fiber port status.
Link Up/Link Down: A trap when linking status occurs in the fiber port.
Abnormal* Receive Error: A trap when there are receive data errors in fiber port.
Abnormal* Transmit Error: A trap when there are transmit data errors in fiber port.
Copper Port Events: Monitoring the copper port status.
Abnormal* Receive Error: A trap when there are receive data errors in copper port.
Abnormal* Transmit Error: A trap when there are transmit data errors in copper port.
Abnormal*: 50 error packet count within 10 seconds.
Set Password
Password is the invaluable tool for the manager to secure Web Management Switch. Use this function to change the password.
If you forget the password, press the “Reset” button in the rear panel of the Switch; the current setting includes VLAN, Port Setting…
etc. will be lost and the Switch will restore to the default setting.

Figure 27. Set Password


Backup Setting
The backup tools help you to backup the current setting of the Switch. Once you need to backup the setting, press the “Backup”
button to save the setting.
To restore a current setting file to the device, you must specify the backup file and press the “Restore” button to process the setting of
the recorded file.

Figure 28. Backup Setting


Note: When restoring a recorded file, the current password will not be erased.

Reset Setting
The Factory Reset button helps you to reset the device back to the default setting from the factory. Be aware that the entire
configuration will be reset; the IP address of the device will be set to the default setting of 192.168.0.1.

27
Figure 29. Reset Setting

Logout
When you use this function, the Web configuration will logout and return to the first Login page.

Figure 30. Logout

28
TECHNICAL SPECIFICATIONS

General

Standards IEEE 802.3 10BASE-T Ethernet


IEEE 802.3u 100BASE-TX Fast Ethernet
IEEE 802.3z 1000BASE-SX/LX Gigabit Ethernet
IEEE 802.3ab 1000BASE-T Gigabit Ethernet
IEEE 802.3x Full Duplex Flow Control

Protocol CSMA/CD

Data Transfer Rate Ethernet: 10Mbps (half-duplex), 20Mbps (full-duplex)


Fast Ethernet: 100Mbps (half duplex), 200Mbps (full-duplex)
Gigabit Ethernet: 2000Mbps (full-duplex)

Topology Star

Network Cables 10BASET: 2-pair UTP Cat. 3, 4, 5; up to 100m


100BASE-TX: 2-pair UTP Cat. 5; up to 100m
1000BASE-T: 4-pair UTP Cat. 5; up to 100m
Fiber module: mini-GBIC Fiber module(1000BBASE-SX/LX)

Number of Ports 48 × 10/100Mbps Auto-MDIX RJ45 ports


2 × 10/100/1000Mbps Auto-MDIX RJ45 ports
2 × mini-GBIC fiber slot (disables the Gigabit Copper ports when active)

Physical and Environmental

AC inputs 100-240V AC, 50-60 Hz internal universal power supply

Power Consumption 24Watts (Max)

Temperature Operating: 0° ~ 40° C (32° ~ 104° F), Storage: -10° ~ 70° C (14° - 158° F)

Humidity Operating: 10% ~ 90%, Storage: 5% ~ 90%

Dimensions 440 x 44 x 310 mm (W x H x D) (17.3 x 1.7 x 12.2 in.)

EMI: FCC Class A, CE Mark Class A, VCCI Class A

Safety: CUL(UL60950)

Performance

Transmits Method: Store-and-forward

Filtering Address Table:


4K entries per device

Packet Filtering/Forwarding
Rate: 10Mbps Ethernet: 14,880/pps
100Mbps Fast Ethernet: 148,800/pps
1000Mbps Gigabit Ethernet: 1,488,000/pps

MAC Address Learning:


Automatic update

Transmits Method: Store-and-forward

RAM Buffer: 1536K Bytes per device

41
REGISTRATION

Register your product on-line at:


http://support.dlink.com/register

Product registration is entirely voluntary and failure to complete or return this form will not diminish
your warranty rights.

43
Subject to the terms and conditions set forth herein, D-Link Systems, Inc. (“D-Link”) provides this Limited Warranty:
• Only to the person or entity that originally purchased the product from D-Link or its authorized reseller or distributor, and
• Only for products purchased and delivered within the fifty states of the United States, the District of Columbia, U.S. Possessions or Protectorates, U.S.
Military Installations, or addresses with an APO or FPO.
Limited Warranty: D-Link warrants that the hardware portion of the D-Link product described below (“Hardware”) will be free from material defects in
workmanship and materials under normal use from the date of original retail purchase of the product, for the period set forth below (“Warranty Period”), except
as otherwise stated herein.

• Hardware (excluding power supplies and fans): One (1) year


• Power supplies and fans: One (1) year
• Spare parts and spare kits: Ninety (90) days
The customer's sole and exclusive remedy and the entire liability of D-Link and its suppliers under this Limited Warranty will be, at D-Link’s option, to repair or
replace the defective Hardware during the Warranty Period at no charge to the original owner or to refund the actual purchase price paid. Any repair or
replacement will be rendered by D-Link at an Authorized D-Link Service Office. The replacement hardware need not be new or have an identical make, model
or part. D-Link may, at its option, replace the defective Hardware or any part thereof with any reconditioned product that D-Link reasonably determines is
substantially equivalent (or superior) in all material respects to the defective Hardware. Repaired or replacement hardware will be warranted for the remainder
of the original Warranty Period or ninety (90) days, whichever is longer, and is subject to the same limitations and exclusions. If a material defect is incapable
of correction, or if D-Link determines that it is not practical to repair or replace the defective Hardware, the actual price paid by the original purchaser for the
defective Hardware will be refunded by D-Link upon return to D-Link of the defective Hardware. All Hardware or part thereof that is replaced by D-Link, or for
which the purchase price is refunded, shall become the property of D-Link upon replacement or refund.
Limited Software Warranty: D-Link warrants that the software portion of the product (“Software”) will substantially conform to D-Link’s then current functional
specifications for the Software, as set forth in the applicable documentation, from the date of original retail purchase of the Software for a period of ninety (90)
days (“Software Warranty Period”), provided that the Software is properly installed on approved hardware and operated as contemplated in its documentation.
D-Link further warrants that, during the Software Warranty Period, the magnetic media on which D-Link delivers the Software will be free of physical defects.
The customer's sole and exclusive remedy and the entire liability of D-Link and its suppliers under this Limited Warranty will be, at D-Link’s option, to replace
the non-conforming Software (or defective media) with software that substantially conforms to D-Link’s functional specifications for the Software or to refund
the portion of the actual purchase price paid that is attributable to the Software. Except as otherwise agreed by D-Link in writing, the replacement Software is
provided only to the original licensee, and is subject to the terms and conditions of the license granted by D-Link for the Software. Replacement Software will
be warranted for the remainder of the original Warranty Period and is subject to the same limitations and exclusions. If a material non-conformance is
incapable of correction, or if D-Link determines in its sole discretion that it is not practical to replace the non-conforming Software, the price paid by the original
licensee for the non-conforming Software will be refunded by D-Link; provided that the non-conforming Software (and all copies thereof) is first returned to D-
Link. The license granted respecting any Software for which a refund is given automatically terminates.
Non-Applicability of Warranty: The Limited Warranty provided hereunder for Hardware and Software portions of D-Link's products will not be applied to and
does not cover any refurbished product and any product purchased through the inventory clearance or liquidation sale or other sales in which D-Link, the
sellers, or the liquidators expressly disclaim their warranty obligation pertaining to the product and in that case, the product is being sold "As-Is" without any
warranty whatsoever including, without limitation, the Limited Warranty as described herein, notwithstanding anything stated herein to the contrary.

Submitting A Claim: The customer shall return the product to the original purchase point based on its return policy. In case the return policy period has
expired and the product is within warranty, the customer shall submit a claim to D-Link as outlined below:

• The customer must submit with the product as part of the claim a written description of the Hardware defect or Software nonconformance in sufficient
detail to allow D-Link to confirm the same, along with proof of purchase of the product (such as a copy of the dated purchase invoice for the product) if the
product is not registered.
• The customer must obtain a Case ID Number from D-Link Technical Support at 1-877-453-5465, who will attempt to assist the customer in resolving any
suspected defects with the product. If the product is considered defective, the customer must obtain a Return Material Authorization (“RMA”) number by
completing the RMA form and entering the assigned Case ID Number at https://rma.dlink.com/.
• After an RMA number is issued, the defective product must be packaged securely in the original or other suitable shipping package to ensure that it will
not be damaged in transit, and the RMA number must be prominently marked on the outside of the package. Do not include any manuals or accessories
in the shipping package. D-Link will only replace the defective portion of the product and will not ship back any accessories.
• The customer is responsible for all in-bound shipping charges to D-Link. No Cash on Delivery (“COD”) is allowed. Products sent COD will either be
rejected by D-Link or become the property of D-Link. Products shall be fully insured by the customer and shipped to D-Link Systems, Inc., 17595 Mt.
Herrmann, Fountain Valley, CA 92708. D-Link will not be held responsible for any packages that are lost in transit to D-Link. The repaired or replaced
packages will be shipped to the customer via UPS Ground or any common carrier selected by D-Link. Return shipping charges shall be prepaid by D-
Link if you use an address in the United States, otherwise we will ship the product to you freight collect. Expedited shipping is available upon request and
provided shipping charges are prepaid by the customer.
D-Link may reject or return any product that is not packaged and shipped in strict compliance with the foregoing requirements, or for which an RMA number is
not visible from the outside of the package. The product owner agrees to pay D-Link’s reasonable handling and return shipping charges for any product that is
not packaged and shipped in accordance with the foregoing requirements, or that is determined by D-Link not to be defective or non-conforming.
What Is Not Covered: The Limited Warranty provided herein by D-Link does not cover: Products that, in D-Link’s judgment, have been subjected to abuse,
accident, alteration, modification, tampering, negligence, misuse, faulty installation, lack of reasonable care, repair or service in any way that is not
contemplated in the documentation for the product, or if the model or serial number has been altered, tampered with, defaced or removed; Initial installation,
installation and removal of the product for repair, and shipping costs; Operational adjustments covered in the operating manual for the product, and normal
maintenance; Damage that occurs in shipment, due to act of God, failures due to power surge, and cosmetic damage; Any hardware, software, firmware or
other products or services provided by anyone other than D-Link; and Products that have been purchased from inventory clearance or liquidation sales or
other sales in which D-Link, the sellers, or the liquidators expressly disclaim their warranty obligation pertaining to the product. While necessary maintenance
or repairs on your Product can be performed by any company, we recommend that you use only an Authorized D-Link Service Office. Improper or incorrectly
performed maintenance or repair voids this Limited Warranty.
Disclaimer of Other Warranties: EXCEPT FOR THE LIMITED WARRANTY SPECIFIED HEREIN, THE PRODUCT IS PROVIDED “AS-IS” WITHOUT ANY
WARRANTY OF ANY KIND WHATSOEVER INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY, FITNESS FOR A
PARTICULAR PURPOSE AND NON-INFRINGEMENT. IF ANY IMPLIED WARRANTY CANNOT BE DISCLAIMED IN ANY TERRITORY WHERE A
PRODUCT IS SOLD, THE DURATION OF SUCH IMPLIED WARRANTY SHALL BE LIMITED TO THE DURATION OF THE APPLICABLE WARRANTY
PERIOD SET FORTH ABOVE. EXCEPT AS EXPRESSLY COVERED UNDER THE LIMITED WARRANTY PROVIDED HEREIN, THE ENTIRE RISK AS TO
THE QUALITY, SELECTION AND PERFORMANCE OF THE PRODUCT IS WITH THE PURCHASER OF THE PRODUCT.
Subject to the terms and conditions set forth herein, D-Link Systems, Inc. (“D-Link”) provides this Limited Warranty:
• Only to the person or entity that originally purchased the product from D-Link or its authorized reseller or distributor, and
• Only for products purchased and delivered within the fifty states of the United States, the District of Columbia, U.S. Possessions or Protectorates, U.S.
Military Installations, or addresses with an APO or FPO.
Limited Warranty: D-Link warrants that the hardware portion of the D-Link product described below (“Hardware”) will be free from material defects in
workmanship and materials under normal use from the date of original retail purchase of the product, for the period set forth below (“Warranty Period”), except
as otherwise stated herein.

• Hardware (excluding power supplies and fans): One (1) year


• Power supplies and fans: One (1) year
• Spare parts and spare kits: Ninety (90) days
The customer's sole and exclusive remedy and the entire liability of D-Link and its suppliers under this Limited Warranty will be, at D-Link’s option, to repair or
replace the defective Hardware during the Warranty Period at no charge to the original owner or to refund the actual purchase price paid. Any repair or
replacement will be rendered by D-Link at an Authorized D-Link Service Office. The replacement hardware need not be new or have an identical make, model
or part. D-Link may, at its option, replace the defective Hardware or any part thereof with any reconditioned product that D-Link reasonably determines is
substantially equivalent (or superior) in all material respects to the defective Hardware. Repaired or replacement hardware will be warranted for the remainder
of the original Warranty Period or ninety (90) days, whichever is longer, and is subject to the same limitations and exclusions. If a material defect is incapable
of correction, or if D-Link determines that it is not practical to repair or replace the defective Hardware, the actual price paid by the original purchaser for the
defective Hardware will be refunded by D-Link upon return to D-Link of the defective Hardware. All Hardware or part thereof that is replaced by D-Link, or for
which the purchase price is refunded, shall become the property of D-Link upon replacement or refund.
Limited Software Warranty: D-Link warrants that the software portion of the product (“Software”) will substantially conform to D-Link’s then current functional
specifications for the Software, as set forth in the applicable documentation, from the date of original retail purchase of the Software for a period of ninety (90)
days (“Software Warranty Period”), provided that the Software is properly installed on approved hardware and operated as contemplated in its documentation.
D-Link further warrants that, during the Software Warranty Period, the magnetic media on which D-Link delivers the Software will be free of physical defects.
The customer's sole and exclusive remedy and the entire liability of D-Link and its suppliers under this Limited Warranty will be, at D-Link’s option, to replace
the non-conforming Software (or defective media) with software that substantially conforms to D-Link’s functional specifications for the Software or to refund
the portion of the actual purchase price paid that is attributable to the Software. Except as otherwise agreed by D-Link in writing, the replacement Software is
provided only to the original licensee, and is subject to the terms and conditions of the license granted by D-Link for the Software. Replacement Software will
be warranted for the remainder of the original Warranty Period and is subject to the same limitations and exclusions. If a material non-conformance is
incapable of correction, or if D-Link determines in its sole discretion that it is not practical to replace the non-conforming Software, the price paid by the original
licensee for the non-conforming Software will be refunded by D-Link; provided that the non-conforming Software (and all copies thereof) is first returned to D-
Link. The license granted respecting any Software for which a refund is given automatically terminates.
Non-Applicability of Warranty: The Limited Warranty provided hereunder for Hardware and Software portions of D-Link's products will not be applied to and
does not cover any refurbished product and any product purchased through the inventory clearance or liquidation sale or other sales in which D-Link, the
sellers, or the liquidators expressly disclaim their warranty obligation pertaining to the product and in that case, the product is being sold "As-Is" without any
warranty whatsoever including, without limitation, the Limited Warranty as described herein, notwithstanding anything stated herein to the contrary.

Submitting A Claim: The customer shall return the product to the original purchase point based on its return policy. In case the return policy period has
expired and the product is within warranty, the customer shall submit a claim to D-Link as outlined below:

• The customer must submit with the product as part of the claim a written description of the Hardware defect or Software nonconformance in sufficient
detail to allow D-Link to confirm the same, along with proof of purchase of the product (such as a copy of the dated purchase invoice for the product) if the
product is not registered.
• The customer must obtain a Case ID Number from D-Link Technical Support at 1-877-453-5465, who will attempt to assist the customer in resolving any
suspected defects with the product. If the product is considered defective, the customer must obtain a Return Material Authorization (“RMA”) number by
completing the RMA form and entering the assigned Case ID Number at https://rma.dlink.com/.
• After an RMA number is issued, the defective product must be packaged securely in the original or other suitable shipping package to ensure that it will
not be damaged in transit, and the RMA number must be prominently marked on the outside of the package. Do not include any manuals or accessories
in the shipping package. D-Link will only replace the defective portion of the product and will not ship back any accessories.
• The customer is responsible for all in-bound shipping charges to D-Link. No Cash on Delivery (“COD”) is allowed. Products sent COD will either be
rejected by D-Link or become the property of D-Link. Products shall be fully insured by the customer and shipped to D-Link Systems, Inc., 17595 Mt.
Herrmann, Fountain Valley, CA 92708. D-Link will not be held responsible for any packages that are lost in transit to D-Link. The repaired or replaced
packages will be shipped to the customer via UPS Ground or any common carrier selected by D-Link. Return shipping charges shall be prepaid by D-
Link if you use an address in the United States, otherwise we will ship the product to you freight collect. Expedited shipping is available upon request and
provided shipping charges are prepaid by the customer.
D-Link may reject or return any product that is not packaged and shipped in strict compliance with the foregoing requirements, or for which an RMA number is
not visible from the outside of the package. The product owner agrees to pay D-Link’s reasonable handling and return shipping charges for any product that is
not packaged and shipped in accordance with the foregoing requirements, or that is determined by D-Link not to be defective or non-conforming.
What Is Not Covered: The Limited Warranty provided herein by D-Link does not cover: Products that, in D-Link’s judgment, have been subjected to abuse,
accident, alteration, modification, tampering, negligence, misuse, faulty installation, lack of reasonable care, repair or service in any way that is not
contemplated in the documentation for the product, or if the model or serial number has been altered, tampered with, defaced or removed; Initial installation,
installation and removal of the product for repair, and shipping costs; Operational adjustments covered in the operating manual for the product, and normal
maintenance; Damage that occurs in shipment, due to act of God, failures due to power surge, and cosmetic damage; Any hardware, software, firmware or
other products or services provided by anyone other than D-Link; and Products that have been purchased from inventory clearance or liquidation sales or
other sales in which D-Link, the sellers, or the liquidators expressly disclaim their warranty obligation pertaining to the product. While necessary maintenance
or repairs on your Product can be performed by any company, we recommend that you use only an Authorized D-Link Service Office. Improper or incorrectly
performed maintenance or repair voids this Limited Warranty.
Disclaimer of Other Warranties: EXCEPT FOR THE LIMITED WARRANTY SPECIFIED HEREIN, THE PRODUCT IS PROVIDED “AS-IS” WITHOUT ANY
WARRANTY OF ANY KIND WHATSOEVER INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY, FITNESS FOR A
PARTICULAR PURPOSE AND NON-INFRINGEMENT. IF ANY IMPLIED WARRANTY CANNOT BE DISCLAIMED IN ANY TERRITORY WHERE A
PRODUCT IS SOLD, THE DURATION OF SUCH IMPLIED WARRANTY SHALL BE LIMITED TO THE DURATION OF THE APPLICABLE WARRANTY
PERIOD SET FORTH ABOVE. EXCEPT AS EXPRESSLY COVERED UNDER THE LIMITED WARRANTY PROVIDED HEREIN, THE ENTIRE RISK AS TO
THE QUALITY, SELECTION AND PERFORMANCE OF THE PRODUCT IS WITH THE PURCHASER OF THE PRODUCT.
Limitation of Liability: TO THE MAXIMUM EXTENT PERMITTED BY LAW, D-LINK IS NOT LIABLE UNDER ANY CONTRACT, NEGLIGENCE, STRICT
LIABILITY OR OTHER LEGAL OR EQUITABLE THEORY FOR ANY LOSS OF USE OF THE PRODUCT, INCONVENIENCE OR DAMAGES OF ANY
CHARACTER, WHETHER DIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL (INCLUDING, BUT NOT LIMITED TO, DAMAGES FOR LOSS OF
GOODWILL, LOSS OF REVENUE OR PROFIT, WORK STOPPAGE, COMPUTER FAILURE OR MALFUNCTION, FAILURE OF OTHER EQUIPMENT OR
COMPUTER PROGRAMS TO WHICH D-LINK’S PRODUCT IS CONNECTED WITH, LOSS OF INFORMATION OR DATA CONTAINED IN, STORED ON,
OR INTEGRATED WITH ANY PRODUCT RETURNED TO D-LINK FOR WARRANTY SERVICE) RESULTING FROM THE USE OF THE PRODUCT,
RELATING TO WARRANTY SERVICE, OR ARISING OUT OF ANY BREACH OF THIS LIMITED WARRANTY, EVEN IF D-LINK HAS BEEN ADVISED OF
THE POSSIBILITY OF SUCH DAMAGES. THE SOLE REMEDY FOR A BREACH OF THE FOREGOING LIMITED WARRANTY IS REPAIR, REPLACEMENT
OR REFUND OF THE DEFECTIVE OR NON-CONFORMING PRODUCT. THE MAXIMUM LIABILITY OF D-LINK UNDER THIS WARRANTY IS LIMITED TO
THE PURCHASE PRICE OF THE PRODUCT COVERED BY THE WARRANTY. THE FOREGOING EXPRESS WRITTEN WARRANTIES AND REMEDIES
ARE EXCLUSIVE AND ARE IN LIEU OF ANY OTHER WARRANTIES OR REMEDIES, EXPRESS, IMPLIED OR STATUTORY.
Governing Law: This Limited Warranty shall be governed by the laws of the State of California. Some states do not allow exclusion or limitation of incidental
or consequential damages, or limitations on how long an implied warranty lasts, so the foregoing limitations and exclusions may not apply. This Limited
Warranty provides specific legal rights and you may also have other rights which vary from state to state.
Trademarks: D-Link is a registered trademark of D-Link Systems, Inc. Other trademarks or registered trademarks are the property of their respective owners.

Copyright Statement: No part of this publication or documentation accompanying this product may be reproduced in any form or by any means or used to
make any derivative such as translation, transformation, or adaptation without permission from D-Link Corporation/D-Link Systems, Inc., as stipulated by the
United States Copyright Act of 1976 and any amendments thereto. Contents are subject to change without prior notice. Copyright 2005 by D-Link
Corporation/D-Link Systems, Inc. All rights reserved.

CE Mark Warning: This is a Class A product. In a residential environment, this product may cause radio interference, in which case the user may be required
to take adequate measures.

FCC Statement: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful interference in a commercial installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communication. However,
there is no guarantee that interference will not occur in a particular installation. Operation of this equipment in a residential environment is likely to cause
harmful interference to radio or television reception. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.

For detailed warranty information applicable to products purchased outside the United States, please contact the corresponding local
D-Link office.

You might also like