• Available with additional 4-year warranty STG79S 10000 (690) -14.7 (-1.0) 100 (6.9)
Communications/Output Options:
Modular Design
Diagnostics To help contain maintenance & inventory costs, all ST 700
SmartLine transmitters all offer digitally accessible transmitters are modular in design supporting the user’s
diagnostics which aid in providing advanced warning of ability to replace meter bodies, standard displays or
possible failure events minimizing unplanned shutdowns, electronic modules without affecting overall performance.
providing lower overall operational costs Each meter body is uniquely characterized to provide in-
System Integration tolerance performance over a wide range of application
variations in temperature and pressure.
o SmartLine communications protocols all meet the most
current published standards for HART. Modular Features
o All ST 700 units are Experion tested to provide the • Meter body replacement
highest level of compatibility assurance
• Add or remove standard displays
Performance Specifications
STG73S 50 psi (3.5 bar) -14.7 psi (-1.0 bar) 0.5 psi (.035 bar)
STG745 500 psi (35 bar) -14.7 psi (-1.0 bar) 5 psi (.35 bar)
STG74S 500 psi (35 bar) -14.7 psi (-1.0 bar) 5 psi (.35 bar)
100:1 0.020 0.065
STG775 3000 psi (210 bar) -14.7 psi (-1.0 bar) 30 psi (2.1 bar)
STG77S 3000 psi (210 bar) -14.7 psi (-1.0 bar) 30 psi (2.1 bar)
STG78S 6000 psi (420 bar) -14.7 psi (-1.0 bar) 60 psi (4.2 bar)
STG79S 10000 psi (690 bar) -14.7 psi (-1.0 bar) 100 (6.9 bar)
Zero and span may be set anywhere within the listed (URL/LRL) range limits
Notes:
1. Terminal Based Accuracy - Includes combined effects of linearity, hysteresis, and repeatability. Analog output adds 0 .006% of span.
2. For zero based spans and reference conditions of: 25 oC (77 oF) for LRV > = 0 psia, 10 to 55% RH, and 316 Stainless Steel barrier
diaphragm.
4 STG700 Smart Pressure Transmitter
Materials Specifications (see model selection guide for availability/restrictions with various models)
Parameter Description
Barrier Diaphragms Material STG700 Dual Head: 316L SS, Hastelloy® C-2762
STG700 Inline: 316L SS, Hastelloy® C-2762
Process Head Material STG700 Dual Head: Carbon Steel (Zinc Plated)5, 316 SS4, Hastelloy® C-2766
STG700 Inline: 316L SS, Hastelloy® C-2766
Vent/Drain Valves & Plugs 1 STG700 Dual Head:316 SS4, Hastelloy® C-2762
STG700 Inline: N/A
Head Gaskets STG700 Dual Head: Glass-filled PTFE standard. Viton® and graphite are optional.
STG700 Inline: N/A
STG700 Dual Head: Carbon Steel (Zinc plated) standard. Options include 316 SS,
NACE A286 SS bolts and nuts or NACE A286 SS bolts and 304 SS nuts, and Super
Meter Body Bolting
Duplex.
STG700 Inline: N/A
Mounting Bracket Carbon Steel (Zinc-plated) or 304 or 316 Stainless Steel, See Figures 3 & 4
Fill Fluid Silicone, CTFE
Pure Polyester Powder Coated Low Copper (<0.4%)-Aluminum. Meets NEMA 4X,
Electronic Housing
IP66, IP67 and NEMA 7 (explosion proof). All stainless steel housing is optional.
Process Connections STG700 Dual Head: ½ -inch NPT(female)
STG700 Inline: ½ -inch NPT(female), ½ -inch NPT male, 9/16 Aminco, G½ -B Male
Thread
Wiring Accepts up to 16 AWG (1.5 mm diameter).
Dimensions See Figure 3 and Figure 4
Net Weight STG700 Dual Head: 8.3 pounds (3.8 Kg). STG700 Inline: 3.6 pounds (1.6 Kg) with
Aluminum Housing
1
Vent/Drains are sealed with Teflon®
2
Hastelloy® C-276 or UNS N10276
4
Supplied as 316 SS or as Grade CF8M, the casting equivalent of 316 SS.
5
Carbon Steel heads are zinc-plated and not recommended for water service due to hydrogen migration. For that service, use 316
stainless steel wetted Process Heads.
6
Hastelloy® C-276 or UNS N10276. Supplied as indicated or as Grade CW12MW, the casting equivalent of Hastelloy® C-276
6 STG700 Smart Pressure Transmitter
HART Protocol
Version:
HART 7
Power Supply
Voltage: 10.8 to 42.4Vdc at terminals
Load: Maximum 1440 ohms See Figure 2.
Minimum Load: 0 ohms. (For handheld communications a
minimum load of 250 ohms is required)
Standard Diagnostics
ST 700 top level diagnostics are reported as either critical
or non-critical and readable via the DD/DTM tools or
integral display as shown.
Critical Diagnostics
HART DD/DTM Tools Standard Display
Electronic Module DAC Fault Comm El
Failure
Meter Body NVM Corrupt Fault Mtrbody
Config. Data Corrupt Fault Comm El
Electronic Module Diag Fault Comm El
Failure
Meter Body Critical Fault Mtrbody
Failure
Sensor Comms Timeout Fault Mbd Com
Non-Critical Diagnostics
HART DD/DTM Tools
Display Failure
Electronic Module Comm Failure
Meter Body Excess Correct
Sensor Over Temperature
Fixed Current Mode
PV Out of Range
No Factory Calibration
LRV Set Error – Zero Config. Button
URV Set Error – Zero Config. Button
AO Out of Range
Loop Current Noise
Meter Body Unreliable Comm
No DAC Calibration
Sensor Supply Voltage Low
Refer to ST 700 manuals for additional level diagnostic
information.
STG700 Smart Pressure Transmitter 7
Flameproof :
T5: -50oC TO 85oC
Ex d IIC T6…T5 Ga/Gb All Note 1
T6: -50oC TO 65oC
Ex tb IIIC T95oC…T120oC Db
Intrinsically Safe: 4-20 mA / DE/
Note 2 -50oC TO 70oC
Ex ia IIC Ga T4 HART
FISCO Field Device (Only for FF Option) Foundation
Ex ia IIC T4 Ga; Ex ic IIC T4 Gc Note 2 -50oC TO 70oC
Fieldbus
SAEx Zone 2, Increase Safety: 4-20 mA / DE/
E
South Africa II 3 G Ex ec IIC T4 Gc HART/
Note 1 -50oC TO 85oC
Foundation
Fieldbus
Zone 2, Intrinsically Safe: 4-20 mA / DE/
Ex ic IIC T4 Gc HART/
Note 2 -50oC TO 85oC
FISCO Field Device (Only for FF Option) Foundation
Ex ic IIC T4 Gc Fieldbus
Enclosure: IP66/ IP67 All All -
Flameproof:
T5: -50oC TO 85oC
Ex db IIC T6..T5 Ga/Gb All Note 1
T6: -50oC TO 65oC
Ex tb IIIC T95oC…T120oC Db
Intrinsically Safe: 4-20 mA / DE/
Note 2a -50oC TO 70oC
Ex ia IIC T4 Ga HART
Flameproof:
T5: -50oC TO 85oC
Ga/Gb Ex d IIC T6..T5 All Note 1
T6: -50oC TO 65oC
Ex tb IIIC Db T 85oC
Intrinsically Safe: 4-20 mA /
Note 2 -50oC TO 70oC
Ga Ex ia IIC T4 X DE/ HART
FISCO Field Device
(Only for FF Option) Foundation
Note 2 -50oC TO 70oC
EAC Ga Ex ia IIC T4 X Fieldbus
Russia, Belarus
Zone 2, Non Sparking: 4-20 mA /
I and
2 Ex nA IIC T4 Gc X DE/ HART/
Kazakhstan Note 1 -50oC TO 85oC
Foundation
Fieldbus
Zone 2, Intrinsically Safe:
4-20 mA /
Ga Ex ic IIC T4 X
DE/ HART/
FISCO Field Device Note 2 -50oC TO 85oC
Foundation
(Only for FF Option)
Fieldbus
2 Ex ic IIC T4 Gc X
Enclosure : IP 66/67 All All
Flameproof: T5: -50oC TO 85oC
All Note 1
Ex d IIC T6..T5 Ga/Gb T6: -50oC TO 65oC
Intrinsically Safe: 4-20 mA / DE/
Note 2 -50oC TO 70oC
Ex ia IIC T4 Ga HART
FISCO Field Device (Only for FF Option) Foundation
CCoE Ex ia IIC T4 Ga; Ex ic IIC T4 Gc Note 2 -50oC TO 70oC
J Fieldbus
INDIA
Non Sparking 4-20 mA / DE/
Ex nA IIC T4 Gc HART/
Note 1 -50oC TO 85oC
Foundation
Fieldbus
Enclosure: IP66/ IP67 All All -
Flameproof:
T5: -50oC TO 85oC
II 1/2 G Ex db IIC T6..T5 Ga/Gb All Note 1
T6: -50oC TO 65oC
II 2 D Ex tb IIIC T95oC…T120oC Db
UATR Intrinsically Safe: 4-20 mA / DE/
K Note 2 -50oC TO 70oC
UKRAINE II 1 G Ex ia IIC T4 Ga HART
FISCO Field Device (Only for FF Option) Foundation
II 1 G Ex ia IIC T4 Ga Note 2 -50oC TO 70oC
Fieldbus
Enclosure: IP66/ IP67 All All -
Notes:
1. Operating Parameters:
Voltage= 11 to 42 V DC Current= 4-20 mA Normal
The revision is on the label that is on the module. There will be two lines of text on the label:
• First is the Module Part #: 50049839-001 or 50049839-002
• Second line has the supplier information, along with the REVISION:
XXXXXXX-EXXXX, THE “X” is production related, THE POSITION of the “E” IS THE REVISION.
SIL 2/3 Certification IEC 61508 SIL 2 for non-redundant use and SIL 3 for redundant use according to EXIDA and
TÜV Nord Sys Tec GmbH & Co. KG under the following standards: IEC61508-1: 2010; IEC
61508-2: 2010; IEC61508-3: 2010.
12 STG700 Smart Pressure Transmitter
millimeters
Reference Dimensions: inches
Figure 3 – Typical mounting dimensions of STG735, STG745 & STG775 for reference
Refer to the User’s manual (34-ST-25-44) for full details on mounting and installation.
STG700 Smart Pressure Transmitter 13
millimeters
Reference Dimensions: inches
Figure 4 – Typical mounting dimensions of STG74S, STG77S, STG78S, & STG79S for reference
Refer to the User’s manual (34-ST-25-44) for full details on mounting and installation.
14 STG700 Smart Pressure Transmitter
Model STG700
Gauge Pressure Transmitters
Model Selection Guide
34-ST-16-122 Issue 8
Instructions: Make selections from all Tables using column below the proper arrow. Asterisk indicates availability. Letter (a)
refers to restrictions highlighted in the restrictions table. Tables delimited w ith dashes.
KEY NUMBER URL/Max Span LRL Min Span Units Selection Availability
50 (3.5) -14.7 (-1.0) 0.5 (.035) psi (bar) STG735
Gauge
500 (35) -14.7 (-1.0) 5 (.35) psi (bar) STG745
Dual Head
3000 (210) -14.7 (-1.0) 30 (2.1) psi (bar) STG775
50 (3.5) -14.7 (-1.0) 0.5 (.035) psi (bar) STG73S
500 (35) -14.7 (-1.0) 5 (.35) psi (bar) STG74S
Gauge
3000 (210) -14.7 (-1.0) 30(2.1) psi (bar) STG77S
In-Line
6000 (420) -14.7 (-1.0) 60 (4.2) psi (bar) STG78S
10000 (690) -14.7 (-1.0) 100 (6.9) psi (bar) STG79S
STG79S
STG77S, STG78S
STG73S,STG74S
STG775
STG735,STG745
H H H
TABLE II Meter Body & Connection Orientation
Standard High Side Left, Ref Side Right2 / Std Head Orientation 1 * * * * *
Head/Connect 2
Reversed Ref Side Left, High Side Right 2 * *
Orientation
90/Standard High Side Left, Ref Side Right2 / 900 Head Rotation 3 h h
STG79S
STG77S, STG78S
STG73S,STG74S
STG775
TABLE VI CALIBRATION & ACCURACY SELECTIONS STG735,STG745
Accuracy Calibrated Range Calibration Qty
a. Accuracy and
Standard Factory Standard Single Calibration A * * * * *
Calibration
Standard Custom (Unit Data Required) Single Calibration B * * * * *
TABLE VIII OTHER Certifications & Options: (String in sequence com m a delim ited (XX, XX, XX,….)
No additional options 00 * * * * *
NACE MR0175; MR0103; ISO15156 Process wetted parts only FG * * * * *
b
NACE MR0175; MR0103; ISO15156 Process wetted and non-wetted parts F7 c c c c c
Marine (DNV,ABS,BV,KR,LR) MT d d d d d
EN10204 Type 3.1 Material Traceability FX * * * * *
Certificate of Conformance F3 * * * * *
b
Calibration Test Report & Certificate of Conformance F1 * * * * *
Certifications & Certificate of Origin F5 * * * * *
Warranty FMEDA (SIL 2/3) Certification FE j j j j j
Over-Pressure Leak Test Certificate (1.5X MAWP) TP * * * * *
Cert Clean for O2 or CL2 service per ASTM G93 OX e e e e e
PM Certification⁵ PM * * * * *
Extended Warranty Additional 1 year 01 * * * * *
Extended Warranty Additional 2 years 02 * * * * *
b
Extended Warranty Additional 3 years 03 * * * * *
Extended Warranty Additional 4 years 04 * * * * *
RESTRICTIONS
Restriction Available Only with Not Available with
Letter Table Selection(s) Table Selection(s)
c Id _ _ _ 0,N,K,D _ _ _
d Iva C, D, G, H _ _ VIIa 1, 2, 3, 5, 6, 7 _ _ _
e Ib _2____
Ie _ _ _ _ 4, 5, 6 _ _
h
VIIa 1, 2, 3, 4, 5, 6, 7 _ _ _
j Vb _ 1,2_
m IV a B,D,F,H _ _
n IV a A,C,E,G _ _
p III B- No CRN number available
s Ia A, E _ _ _ _ _
t Ia J_____
b Select Only one option from this group
⁵
The PM option is available on all Smartline Pressure Transmitter process wetted parts such as process heads, flanges, bushings and vent
plugs except plated carbon steel process heads and flanges. PM option information is also available on diaphragms except STG and STA in-
line construction pressure transmitters.
PRODUCT MANUALS
Description Part Number
ST 700 Smart Transmitter User Manual - English 34-ST-25-44
ST 700 Smart Transmitter HART Communications Manual - English 34-ST-25-47
ST 700 Smart Transmitter Safety Manual - English 34-ST-25-37
All product documentation is available at www.honeywellprocess.com.
Sales and Service
For application assistance, current specifications, ordering, pricing, and name of the nearest Authorized Distributor,
contact one of the offices below.
Singapore
Honeywell Pte Ltd.
Phone: +(65) 6580 3278
Fax: +(65) 6445-3033
South Korea
Honeywell Korea Co Ltd
Phone: +(822) 799 6114
Fax: +(822) 792 9015
Process Solutions
Honeywell
1250 W Sam Houston Pkwy S
Houston, TX 77042