Cyclohexane Storage Tank (T-102) : Technological Institute of The Philippines
Cyclohexane Storage Tank (T-102) : Technological Institute of The Philippines
Cyclohexane
Storage Tank
(T-102)
1
Technological Institute of the Philippines
2
Technological Institute of the Philippines
3
Technological Institute of the Philippines
SPECIFICATION
Description Cyclohexane Storage Tank
Equipment Tag T-101
Type Storage Tank
Orientation Vertical
Material of Construction 3.4 Stainless Steels
No. of Tank Required 3 units/s
Design Temperature 25 °C
Design Pressure 0.1773 MPa
Tank Volume 136.9490 m3
DESIGN DIMENSION
Total Tank Height 8.5832 m
Tank Inside Diameter 4.2916 m
Tank Outside Diameter 4.3002 m
Shell Thickness 4.3069 mm
Head Thickness 8.0790 mm
Head Height 0.8567 m
Crown Radius 4.2916 m
Knuckle Radius 0.2575 m
Inlet Nozzle Diameter 38.4569 mm
Inlet Nozzle Thickness 4.0207 mm
Outlet Nozzle Diameter 41.0097 mm
Outlet Nozzle Thickness 4.0220 mm
MECHANICAL DESIGN
Actual tank circumference 13.5096 m
Actual tank diameter 5.8210 m
Actual inside diameter 5.8124 m
Actual tank height 7.1995 m
Actual Crown radius 5.8124 m
Actual knuckle radius 0.3487 m
Actual cylinder height 5.4861 m
Surface area of torispherical head 28.0193 m2
Surface area of torispherical bottom 28.0193 m2
No. of plates for tank circumference 3 plates
No. of plates for tank height 3 plates
No. of plates for tank head 3 plates
No. of plates for tank bottom 3 plates
Total number of plates for the shell 9 plates
Total number of plates for the whole tank 15 plates
4
Technological Institute of the Philippines
Data Assumptions:
Design Calculations
Volumetric Flowrate
m
Q=
ρ H 2O
5
Technological Institute of the Philippines
kg
88252.5311
day
Q=
kg
773.303 3
m
m3
Q=114.1241
day
Tank Capacity
m3 (
(
V = 114.1241
day )
3 days )
V =342.3724 m3
Number of Tanks
ASSUPMTION: The available volume of tank available for the market and is
specifically applicable for the process is 32,500 gallons or 123025.89 L.
342.3724 m3
N Tank =
123025.89 L 1 m3
×
tank 1000 L
342.3724 m3
V t=
2 tanks
V t =114.1241 m 3
Design Volume
6
Technological Institute of the Philippines
V Tank =1.2 V t
3
V Tank =136.9490 m
Where:
π 2
V Cylinder = D H
4 i Cylinder
(ref. Table 10-60. Page 10-145. Perry, R. & Green D. (2008). Perry’s
Chemical Engineer’s Handbook, 8th Edition)
π 2
V Tank = D H + 2(0.0809 D 3i )
4 i Cylinder
π 2
V Tank = D i (2 D i)+2(0.0809 D 3i )
4
7
Technological Institute of the Philippines
π 3
V Tank = Di +2(0.0809 D 3i )
4
π
136.9490 m 3= D 3i + 2(0.0809 D 3i )
2
Di=4.2916 m
Height of Cylinder
H Cylinder =8.5832m
π 2
V Mixture= D H
4 i Mixture
π
114.1241 m 3= ¿
4
H Mixture=7.8894 m
Working Pressure
P=POptimum + ρg H Mixture
kg m
(
P=101,325 Pa+ 773.3030
m )(
3 )
9.81 2 ( 7.8894 m )
s
Design Pressure
ASSUMPTION: The design pressure was set to exceed 10% of the operating
pressure (ref. Chapter 13.4.1-2, page 810, Coulson and Richardson, Chemical
Engineering Design, Vol. 6,4th ed.)
8
Technological Institute of the Philippines
Design Pressure=1.1 P
Shell Thickness
PD D i
t sp = +C
2 Jf −P D
(ref. Eqn. 13.39. Page 815. Sinnot, R.K. (2005). Coulson & Richardson’s
Chemical Engineering Design, Volume 6, 4th Edition)
Where:
D= Inside Diameter, mm
J= Joint Efficiency, 1.0 (ref. Table. 13.3. Page 813. Sinnot, R.K. (2005).
Coulson & Richardson’s Chemical Engineering Design, Volume 6, 4th Edition)
F= Design Stress, N/mm2 (ref. Table. 13.2. Page 812. Sinnot, R.K. (2005).
Coulson & Richardson’s Chemical Engineering Design, Volume 6, 4th Edition)
t sp =
( 0.1773
mm2 )
(4291.6119 mm)
+ 4 mm
N N
(
2 ( 1 ) 165
mm2 )(
− 0.1773
mm2 )
9
Technological Institute of the Philippines
t sp =4.3069mm
Torispherical Head
PD RCCS
t h= +C
2 Jf +(C s −0.2)
(ref. Eqn. 13.34 Page 819. Sinnot, R.K. (2005). Coulson & Richardson’s
Chemical Engineering Design, Volume 6, 4th Edition)
Where:
Rc = Crown Radius, m
D= Inside Diameter, mm
837
C= Corrosion Allowance, mm
Crown Radius
RC = D i
RC =4.2916 m
Knuckle Radius
Rk =0.06 D i
Rk =0.06 ( 4.2916 m )
Rk =0.2575 m
10
Technological Institute of the Philippines
Stress Concentration
R
C s=
1
4( √ )
3+ C
Rk
1 4.2916 m
C s=
4( √
3+ )
0.2575 m
C s=1.7706
t =
( 0.1773
mm )
2
( 4291.6119 mm )( 1.7706 )
+4 mm
h
N
( mm )−(1.7706−0.2)
2 ( 1 ) 165 2
t h=8.0790 mm
DO =Di+ 2t
D O =4.2916 m+2(0.0043)m
DO =4.3002 m
H Head=856.6943 mm ≈ 0.856 7 m
11
Technological Institute of the Philippines
H Tank =10.2966 m
Nozzle Design
General Guidelines
2 kg
For inlet fluids (Liquid or Gas): ρ v ≤1000
m−s2
2 kg
For outlet gas: ρ v ≤3600
m−s2
For outlet liquids: v = 1 m/s
ṁ
Q̇= AV =
ρ
kg
1.0214
s
Q̇=
kg
773.3030 3
m
m3
Q̇=0.0009
s
2
m3 π d 0 m
0.0009 = ×1
s 4 s
d o =0.0410 m≈ 41.0097 mm
Pido
t no= +C
2 Jf −Pi
12
Technological Institute of the Philippines
t =
( 0.1773
mm )
( 41.0097 mm )
2
+ 4 mm
no
N N
( mm )−(0.1773 mm )
2 ( 1 ) 165 2 2
t no=4.0220 mm
kg
ρ v 2=1000
m−s2
kg
√
1000
m−s 2
v=
kg
773.3030 3
m
m
v=1.1372
s
Q= AV
2
m3 π d 0 m
0.0013 = ×1
s 4 s
d 1=0.0385m ≈ 38.4569 mm
t=
¿
( 0.1773
mm )
(38.4569 mm)
2
2(1)¿ ¿
t ¿=4.0207 mm
13
Technological Institute of the Philippines
Actual Design
C Tank =π D o
C Tank =π ( 4.3002 m)
C Tank =13.5096 m
18.2871 m
D o , act=
π
Do , act=5.8210m
D i , act=D o ,act −2 t
D i , act=5.8124 m
14
Technological Institute of the Philippines
Rk , act =0.3487 m
Rc , act=D i , act
Rc , act=5.81 24 m
Volume of Shell
V Shell =131.4666 m 3
π 2
V Shell = D H
4 i ,act cylinders
H cylinders =4.9547 m
3.281 ft 1 plate
N Cylinder =4.9547 m× ×
1m 6 ft
15
Technological Institute of the Philippines
6 ft 1m
H Cylinder =3 plates × ×
1 plate 3.281 ft
H Cylinder =5.4861 m
A Head=0.264 π Di , act2
A Head=0.264 π ¿
A Head=28.0193m 2
1 plate
N Head=28.0193 m2 ×
(6.0957 ×1.8283) m2
N Head=2.5141 m≈ 3 Plates
A Bottom=0.264 π D i ,act2
A Bottom=0.264 π ¿
A Bottom=28.0193 m2
1 plate
N Bottom =28.0193 m2 × 2
(6.0957 ×1.8283)m
16
Technological Institute of the Philippines
N Shell =3 ×3
N Shell =9 plates
π 2
V Tank = D i , act H Cylinder ,act + 0.0809 D 3i , act
4
π
V Tank = ¿
4
V Tank =163.2378 m3
H 10.2966 m
= =2.3992
D 4.2916 m
Tank Orientation
17
Technological Institute of the Philippines