Meter Manual
Meter Manual
PASS Err
DIN RAIL SMART METER Phase to neutral voltage To exit setting-up mode, press repeatedly until the Use MD and
THD% of 2nd to 19th. measurement screen is restored. buttons to select the
FOR SINGLE AND THREE PHASE required system option:
ELECTRICAL SYSTEMS 1P2 (W),3P3 (W),3P4 (W).
2.Start Up Screens
Press the to enter the
change password routine. Press to enter the
The first screen lights up Instantaneous Reactive The new password screen selection routine. The unit
all display segments and Power in kVAr. will appear with the first symbol will flash.
can be used as a display digit flashing.
check.
C1C2
Use MD and to set
the first digit and press Use MD and
Instantaneous Volt-Amps to confirm your buttons to choose kWh or
in KVA. selection. The next digit kVArh.
Software version information will flash.
Use
MD
and
4.6.2 Pulse Duration
Warnings buttons to select the time The energy monitored can be active or reactive and the pulse
required. width can be selected as
Important Safety Information is contained in the Exported reactive energy
Maintenance section. Familiarize yourself with this 200,100 (default) or 60ms.
information before attempting installation or other
procedures. Symbols used in this document:
Press to enter the * Maximum operating and storage temperatures are in the
selection routine. The MD context of typical daily and seasonal variation.
Use MD
and buttons to choose pulse width. will flash.
confirm the setting and press button to return the main • Exported reactive energy 0 to 999999.99 kVarh
set-up menu. • Imported active energy 0 to 999999.99 kWh
• Exported reactive energy 0 to 999999.99 kVarh
4.7.2 Baud Rate • Total active energy 0 to 999999.99 kWh
• Total reactive energy 0 to 999999.99 kVArh
the setting and press to return to the main set up menu. 5.3.1 Pulse Output
The pulse output can be set to generate pulses to represent 8 9 10
4.7.3 Parity kWh or kVArh.
5 6 7 11 12 13
Rate can be set to generate 1 pulse per:
dFt (default) = 2.5 Wh/VArh
From the set-up menu, use 0.01 = 10 Wh/VArh
MD
and buttons to 0.1 = 100 Wh/VArh
select the parity option. 1 = 1 kWh/kVArh
10 = 10 kWh/kVArh
100 = 100 kWh/kVArh
Pulse width 200/100/60 ms.
Press to enter the Pulse output 2 is non-configurable.It is fixed up with active kWh.
selection routine. The Its constant is 400imp/kWh.
current setting will flash.
1 2 3 4
5.3.2 RS485 Output for Modbus RTU
For Modbus RTU, the following RS485 communication
parameters can be configured from the set-up menu:
MD
Use and buttons
Baud rate 2400, 4800, 9600, 19200, 38400
to choose parity (EVEN /
ODD / NONE). Parity none / odd / even
L1 L3 L2
Stop bits 1 or 2
RS485 network address nnn – 3-digit number, 001 to 247
On completion of the entry procedure, press to confirm
7.3 three phase four wires
the setting and press to return to the main set up menu. 5.4 Accuracy
• Voltage 0·5% of range maximum 2
1
Use MD and
errors to a minor degree. Accuracy is verified under nominal 1 2 3 4
value (within the specified tolerance) of these conditions.
buttons to choose stop bit
(2 or 1) • Ambient temperature 23°C ± 2°C
• Input frequency 50 or 60Hz ±2%
• Input waveform Sinusoidal (distortion
On completion of the entry procedure, press to confirm factor < 0·005)
the setting and press to return to the main set up menu. • Magnetic field of external origin Terrestrial flux
L1 L2 L3 N