Omny Classics Catalogue and Manual - en
Omny Classics Catalogue and Manual - en
Omny Classics Catalogue and Manual - en
Contents
04 Introduction 18 Drills 40 Digitals
Key
Materials
Inox Stainless steel PA Polyamide PTFE Polytetrafluoroethylene
Handling instruments
equator mua angulated
microesam stepper
Restorative components
non-rotating rotating
Abbreviations
H Height
ø Diameter
L Length
The measurements shown in the catalogue are expressed in mm.
p Platform The images shown are solely representative of the products.
3
omny classics
Simply everything
Omny dental implants have been designed by Geass to facilitate teams in the development of implant
prosthetic restoration, offering simple, complete and innovative yet affordable solutions.
Simplicity
Essential protocol: few surgical steps, control of the osteotomy thanks to
the drill stops.
Completeness
Wide range: three diameters, six lengths and two thread variants to meet
all clinical needs.
4
Innovation
Synthegra: the implant surface treatment patented by Geass to reduce the
risks of peri-implantitis while, at the same time, promoting osseointegration.
Digital technologies: also for Omny Classics, Geass is able to offer all the
solutions necessary to manage a digital workflow.
Affordability
Efficient solutions and flexible kits to optimise clinic resources.
5
Packaging
Omny Classics implants are packaged in PETG and Tyvek blisters to
guarantee sterility. An information label is provided on the back of each
blister, and the blister is contained in a box with the same information
label.
The integrity of the packaging is guaranteed by the sticker label, which also
indicates the diameter and length of the implant.
Label
Manufacturer
patient card
IMPIANTO DENTALE ø 3,75 L.8,5
DENTAL IMPLANT ø 3.75 L.8.5
Sterilization
The implants are sterilized with ionizing radiation according to a protocol validated in compliance with the
regulations in force. All products are supplied decontaminated in non-sterilisable packaging.
6
implants
7
Implants
ø 3.25 ø 3.25 XL
platform 3.4 platform 3.4
L L
7 28998 7 29016
8.5 29001 8.5 29019
10 29004 10 29022
11.5 29007 11.5 29025
13 29010 13 29028
15 29013 15 29031
Ti Ti
ø 3.75 ø 3,75 XL
platform 4.1 platform 4.1
L L
7 29573 7 29591
8.5 29576 8.5 29594
10 29579 10 29597
11.5 29582 11.5 29600
13 29585 13 29603
15 29588 15 29606
Ti Ti
ø 4.1 ø 4,1 XL
platform 4.1 platform 4.1
L L
7 28962 7 28980
8.5 30480 8.5 30484
10 30481 10 30485
11.5 30482 11.5 30486
13 30483 13 30487
15 28977 15 28995
Ti Ti
! Omny XL implants
are not for use in D1 bone
8
2,55 2,55 2,7 2,7 2,7 2,55 2,7 2,55 2,7 2,7
2,55 2,55 2,7 2,7 2,7 2,55 2,7 2,55 2,7 2,7
3,4 3,4 4,1 4,1 4,1 3,4 4,1 3,4 4,1 4,1
3,4 3,4 ø 3.25
4,1 4,1 4,1 3,4 4,1 ø 3,4
3.25 XL 4,1 4,1
L L 1:1 L L L L 1:1 L L L L
L L L L L L L L L L
2,3 2,3 2,7 2,5 3,2 2,3 2,8 2,3 2,7 2,5
2,55 2,7 2,55 2,7 2,55 2,7 2,7 2,7 2,7 2,7 2,7
2,3 2,3 2,7 2,5 3,2 2,3 2,8 2,3 2,7 2,5
2,55 2,7 2,55 2,7 2,55 2,7 2,7 2,7 2,7 2,7 2,7
3,4 4,1 3,4 4,1 3,4 4,1 4,1 4,1 4,1 4,1 4,1
3,4 4,1 3,4 4,1 3,4 4,1 4,1 4,1 4,1 4,1 4,1
ø 3.75 ø 3.75 XL
L L L L L L L L L L L
1:1 1:1
L L L L L L L L L L L
2,3 2,7 2,3 2,5 2,3 3,2 2,7 2,8 2,5 3,2 2,8
2,7
2,3 2,55 2,7
2,7 2,7
2,3 2,7
2,5 2,7
2,3 3,2 2,7
2,7 2,8 2,7
2,5 3,2 2,8
2,7 2,55 2,7 2,7 2,7 2,7 2,7 2,7
L L L L L L L L L
L L L L L L L L L
1:1 1:1
9
Surgical protocol
Preparing the implant site
The methods and instruments used to prepare the implant site depend solely on the implant diameter and bone
type*.
! In the event of compact bone, or if the implant insertion torque exceeds 50 N•cm, the implant site must be tapped
with a special tapper. This prevents excessive compression of the tissues at the crestal level.
The use of XL implants is not intended for D1 bone.
* Classification is that processed by Misch (Bone character: second vital implant criterion, Dent Today 7:39-40, 1998), which distinguishes four types of
bone density on the basis of the macroscopic characteristics of the cortical and trabecular bone of the edentulous portion to be treated.
countersink
lance drill
bone D1-D2
10
Surgical sequence ø 3.75 - 3.75XL
twist drill ø 3
countersink
lance drill
tapper
rpm 800 600 600 400 400 bone D1-D2
countersink
lance drill
tapper
11
Touch&go
Implant removal
Touch&go is an innovative system which allows for fast, safe removal of
implants without compromising sterility. Its special ergonomics lets you
block the implant in place, facilitating coupling between the implant seat
and the insert.
1 Before opening the packaging, check the label on the back to make 1
sure that the diameter and length measurements of the implant are
suitable for the intervention. Open the blister according to your the
procedure of your dental clinic for maintaining sterility.
2
2 Keep touch&go in a vertical position and remove the upper part,
where the cover screw is contained.
3 Continue to keep the touch&go vertical, press with one hand on the 3
raised part of the sides so that both titanium plates come closer
together: this ensures implant blocking.
With the other hand, connect the Classics spanner or insert with the
implant, grasping gently.
Release pressure on the touch&go and remove the implant.
4 After having inserted the implant, remove the cover screw contained
in the upper body of the touch&go using the Microesam tip.
12
Implant insertion
Classics Classics
Insert Driver
Remove the implant from the touch&go with a Remove the implant from the touch&go with a
spanner equipped with a Classics insert. Classics driver.
Insert it in the implant site and complete implant Insert it in the implant site and complete positioning
positioning flush with the crest line. flush with the crest line, keeping below 15 rpm and
not exceeding 50 N•cm torque.
13
Tightening the cover screw
Microesam
instruments
Remove the cover screw from the upper part of the touch&go with the spanner provided with a Microesam tip.
After cleaning the implant seat, tighten the cover screw, applying a maximum torque of 15 N•cm.
Cover screw
Supplied with the implant, seals the implant seat during healing.
Ti 15 N•cm
p.3.4 p.4.1
14
Surgical organizer
PPSU SI instruments not included 30541
Rationally contains all the surgical and prosthetic instruments of the Omny
Classics implant system.
Fitted to also house the devices necessary for use of the Omny line with
internal connection.
The tray contains the rotating instruments and inserts, the spanners are
housed in the bottom. Once closed, the tray remains inclined to make
access to instruments easier. The bottom is equipped with non-slip silicon.
Made of plastic, autoclavable.
Supplied with x-ray template.
15
Omny Classics line products that can be housed in the organizer.
16
XL XL XL classics
16 c-angle
adapter
hard bone
tapper 17 18 19 20 21 22 23 24
3.25 3.75 4.1
25 26
countersink
mua ang
omny classics 15
lance drill pin drill pin drill pin drill pin drill pin
2.3 2.7 3 3.6 4.1
1 3 5 6 8 9 11 12 14
2 4 7 10 13
3.5 4.1 4.6
27 28 31 hard bone
enlarger
34
equator
29 30 32 omny 33 35
36 37 38 39 40 41
7 8.5 10 11.5 13 15 stop 7 8.5 10 11.5 13 15
42
43
44 45
46
47
17
Drills
The visual references present on the drills allow you to evaluate the depth drilled based on the length of the
implant chosen.
The perforation phases must be carried out with a up and down movement of the drills, without ever exceeding
the maximum speed indicated in each phase of the protocol. Low bone bleeding and high bone density require
a reduction in the recommended number of rpms.
Do not use drills that are damaged, not sharp or which have been used for more than 4 applications in order
to reduce the risk of overheating and bone trauma which may compromise the osseointegration process.
28 short - 35 long
Lance drill short 11664
long 11665
Inox
Twist drill ø L
2.3 short 25734
33
Inox 15
2.3 long 25743 13
11.5
2.7 short 29210 10
8.5
2.7 long 29212 7
3 short 25737
0
3 long 25746
3.6 short 25740
3.6 long 25749 0.8
Prepares the implant site based on the length of the chosen implant. The
measurements indicated by the notches do not include the tip of the
drill, equal to approximately 0.8 mm. It is therefore advisable to consider
this difference when planning perforation.
41
15
13
11.5
10
8.5
7
18
Drill stop
Inox implant length
7 8.5 10 11.5 13 15
25931 25934 25937 25940 25943 28097
Inserted on the twist drills to ensure maximum safety for Clinicians and
patients. Do not use with post-extractive techniques or with a surgical
guide.
Indicator pin ø
2.3 25946
Ti PU 2.7 29328 15
3 25949 13
11.5
3.6 25975 10
8
7
Inserted in the implant site being prepared, it indicates the axis and depth
thanks to the grooves present, as shown in the diagram to the side.
0
Countersink 30421
21
Inox
4.1
To be used after the twist drills the twist drills. Lets you create adequate
housing for the implant collar at the bone crest level. The depth of use
5.5
depends on the type of implant: for ø 3.25 implants, it must be sunk to the
3.5
first notch; for ø 3.75 and ø 4.1 implants down to the second notch.
3.4
19
Tapper ø implant
3.25 30404
Ti 3.25 XL 30413
3.75 30407
3.75 XL 30416
4.1 30410
4.1 XL 30419
Inox
20
Motors for implantology new
Thanks to their well thought-out design, safety of use and the highest quality
materials, W&H equipment meets the standards required to guarantee
maximum precision in the field of oral surgery.
The Implantmed unit has been developed especially for implant procedures
and offers all the tools necessary to ensure maximum precision, safety and
reliability.
The W&H contra-angles, made of high quality stainless steel with special anti-
scratch coating, are characterised by their particular robustness and effective
ergonomics.
As the undisputed leader LED technology, W&H has developed surgical contra-
angles with Mini-LED+, which offer excellent natural light and high contrast
illumination.
The W&H product range is extremely flexible: Clinicians can choose multiple
LED+ connection options, wireless or wired foot control, and a possible Osstell
ISQ module for the control and documentation of osseointegration values.
Surgical planning
Depth probe 29993 5
7
9
Inox
11
13
Ideal instrument for checking the osteotomy depth. The different 15
measurements are also shown on the stem to facilitate reading.
10 mm 20 mm
omny
scala 1:1 - TC scala 1,1 : 1 scala 1,25 : 1
classics scale 1:1 - CT Radiografia endorale Ortopantomografia
scale 1.1 : 1 scale 1.25 : 1
Endoral radiograph Orthopantomograph
ø 3,25 ø 3,25 XL
7 7
8,5 8,5
10 10
1:1 11,5 1:1 11,5
13 13
15 15
7 7
8,5 8,5
10 10
X-ray template
1,1:1 11,5 1,1:1 11,5
13 13
30543
15 15
7 7
8,5 8,5
10 10
1,25:1 11,5 1,25:1 11,5
13 13
15 15
ø 3,75 ø 3,75 XL
7 7
8,5 8,5
10
Presents all the sizes of Omny implants according to the following scale:
10
1:1 11,5 1:1 11,5
13 13
15 15
7 7
8,5 8,5
10 10
1,1:1 11,5 1,1:1 11,5
13 13
7 7
8,5 8,5
10 10
1,25:1 11,5 1,25:1 11,5
13 13
ø 4,1 ø 4,1 XL
7 7
8,5 8,5
10 10
11,5 11,5
7 7
8,5 8,5
10 10
cod. 30543 • rev.0 • 2019-09
11,5 11,5
1,1:1 13 1,1:1 13
15 15
7 7
8,5 8,5
1,25:1 10 1,25:1 10
11,5 11,5
13 13
15 15
21
Spanners and inserts
To be used to handle implants and prosthetic components. All inserts can be used alone or in combination
with a screwdriver or a Newton torque wrench. In the latter case, make sure that the coupling between the
two devices is correct.
Drivers are inserted onto the hand piece to handle the various devices easily and quickly. Make sure that they
are being held effectively. A maximum speed of 15 rpm is recommended.
For the tightening of prosthetic components, always use a torque-controlled wrench, as the use of a
screwdriver can easily lead to excessive torques.
During use of the spanners and inserts, it is important to avoid lateral flexing which could break the instrument
or cause damage to the components that are being handled.
Classics
Inox SI
To remove the implant from the touch&go and place it in the implant site.
22.5
long 30396
o-ring 30401
short long
insert insert
Driver 30399 20
o-ring 30401
22
Microesam
Inox
29
For handling the cover screws and most of the prosthetic components. 19
1.25
30
24
short long
driver driver
19
Equator insert 26496
holder (replacement) 26497
Inox POM
23
Handling instruments
94.5
Newton torque wrench 26870
lubricant 17002
Inox SI o-ring (3 pcs.) 21143
Coupled with the inserts, used to screw and unscrew the different devices
easily and quickly, in one of two ways: ratchet (no pre-defined torque limit)
or dynamometric (calibrated torque) mode.
Once the appropriate insert has been selected, insert it into the head of
the spanner, rotating it until the hexagonal profiles of the two devices are
coupled and push the insert all the way down.
The “IN” arrow on the spanner head shows the position for tightening.
Turning the device upside-down, the “OUT” arrow indicates the spanner
position that permits loosening. Pay attention to the position of the
spanner during use so that its rotation axis coincides with the axis of the
device being handled.
To adjust torque, rotate the handle to the desired value. The adjustment
key provided in the package lets you switch between values more quickly.
Torque selection must always be made when screwing the handle.
Therefore, if you need to adjust a torque lower than that used, unscrew
by two turns less than the new desired torque, and then re-tighten to the
desired value.
To use the spanner without a pre-defined torque value, rotate the handle
until "R" appears.
24
I-Move screwdriver 14242
o-ring (3 pcs.) 21143
Inox SI
Allows you to use the various inserts manually, maximising the perception
and sensitivity in handling.
You will feel a click when the insert comes into contact with the screwdriver,
signalling that coupling has taken place correctly.
6.5
To be used with inserts in order to easily reach the regions of intervention
between the two dental elements.
5.4
85
Inox
115
Inox SI
Coupled with the inserts, it allows easier handling during implant insertion,
ensuring excellent direction control.
Due to the high torque values that it can easily reach, it should not be used
for the tightening of prosthetic components.
101
Equator inserter/extractor 26868
Inox PA
25
prosthetic
components
26
platform 3.4 for ø 3.25 mm implants
Healing abutment
Impression
Fusion Melty
Fusion Melty
non-rotating non-rotating
rotating abutment rotating abutment
abutment abutment
Where present, fixing screws are always supplied together with prosthetic components. This screw is to be used
for definitive fixing only.
27
Management of soft tissues
Healing abutment H
H
Ti 15 N•cm 2 30895 30901
4 30897 30903
6 30899 30905
28
Impression
Pick-up Coping H
Ti 15 N•cm 3 30917
screw 18729
6 30915 30919 H
screw 30989
Basic Coping
Ti 15 N•cm 30921 30923 12
screw 30988
Analog
30925 30927
Ti
Multi-App abutment
15 N•cm 30372 30371
Ti
35 N•cm if used as a definitive abutment short screw 30990
long screw 30374
Precision abutment H
7
Ti 35 N•cm
straight 1 30929 30933
3 30931 30935
H
5 30703 30937
7
25° 1 30943 30951
3 30945 30953
H
screw 30990
14°
7
Custom abutment
30706 30955 12
Ti 35 N•cm
screw 30990
Fusion abutment
PMMA Ti Au
alloy 35 N•cm non-rotating 30956 30958
abutment 7.5
rotating 30957 30959 11.5
screw 30990
Au
alloy 35 N•cm
30
Melty abutment
4 N•cm in lab non-rotating 30961 30962 10.5
PMMA
35 N•cm definitive element
abutment
rotating 30960 30963
1.5
screw 30990
Toronto abutment
PMMA Ti 35 N•cm 30965 30967 8
screw 30990
11.5
castable 20214 20215 3.5
and spacer 1.5
Spherical abutment H
Retainer 11674
o-ring replacement 11675
Ti NBR
31
Equator abutment H
2 30969 30979 H
Ti 35 N•cm
3 30971 30981
4 30973 30983
5 30975 30985
6 30977 30987
Ti PA EVA
Ti PA EVA
32
Mua
Created for total fixed restorations with distally inclined implants. Mua
components allow the emerging parts of the inclined implants in posterior
sectors to be set parallel. Prosthesis positioning, passivation and fixing
operations are therefore much easier.
For easy handling, a peek accessory is provided in the pack. Once the
straight abutment is positioned, simply bend and remove the accessory, 2.2
pulling it out. Fix the abutment with the Stepper insert at the indicated H
torque.
17°
27°
27° H
3.2
1 30183 25693 H
3 30186 29627 27°
5.2 H
Includes a pre-mounted titanium accessory which facilitates positioning
and lets you verify the direction of the prosthetic axis. Once the angulated
abutment with special insert has been tightened to the indicated torque,
remove the accessory by simply unscrewing it by a few turns.
33
Mua healing abutment 25848
4.3
Ti 15 N•cm
Ti
Recreates in the plaster model the position of the implant on which the
Mua abutment has been fixed.
34
Prosthetic protocol
Impression
Custom impression tray Standard impression tray
Cap positioning
35
Temporary restoration
Insert the abutment onto the implant and fix it with the long screw.
Re-line the temporary crown and fix it to the abutment with resin.
Once the resin has hardened, unscrew the screw, remove the element and
finish it.
Replace the long screw with the short one for definitive fixing. Position
some material (i.e. cotton) on the head of the screw and seal it with resin.
Upon removal of the temporary abutment, drill a hole in the upper part with
a round drill until the head of the screw is found. The material introduced
previously has the function of informing the Clinician of the proximity of
the screw, preventing him/her from ruining it.
36
Fixed restoration
Cemented Screwed
Milling Waxing
Cementing of the aesthetic part on the abutment Cementing of the Fixing of the
aesthetic part aesthetic part
37
Toronto Bridge restoration Mobile restoration
Toronto Spherical
abutment abutment
Bar casting
38
Mobile restoration
Fixing of the Equator abutment in the lab Fixing of the Equator abutment in the surgery
Positioning the ring and retainer on abutments Creating space for retainers on prostheses
39
digitals
Digital evolution
The digital solutions proposed by Geass constitute an open, flexible and
economical system that allows you to:
- Acquire a complete digital flow
- Utilise innovative technologies that are adaptable to any IT system
- Implement your own digital structure with versatile equipment and
instruments
- Define an effective surgery-laboratory work flow.
40
Performa
Scanbody
30707 30708
Ti PEEK
Linker V2
6
Ti 35 N•cm 4
The height of the Linker is easily adaptable to the clinical situation, thanks retention pre-cut
to the pre-cut groove which, finding correspondence in the libraries, also for cement groove
facilitates the technician in the design of the prosthesis.
anti-rotation
Digital analog
Ti 30709 30710
Specific for processing that derive from taking digital impressions, it ensures
correct repositioning on the 3D printed model thanks to the presence of
hexagonal sides, which also facilitate insertion.
The screw, included in the pack, ensures analog stability in the model and
in many cases avoids the use of adhesive substances. The screw must be
tightened with the Performa Torque tool.
Geass digital analogs are complete with the implant libraries necessary for
virtual modelling through the main CAD softwares and for the creation of
models using 3D printing.
41
Base for wax up
PMMA 3 pc. pack 30715 30716
To be used in the lab for modelling the wax-up and to then send to Geass for
digitalization.
Inox
29
23
Inclined hole insert short 25449
long 25112
Inox
short long
insert insert
short long
insert insert
Inox POM
To be used exclusively in the lab to tighten the scanbody and the PMMA
castables on the analogs, at a pre-defined torque of 4 Ncm.
42
advanced
Regenerative solutions
PPSU SI
Inox WC
5
For sinus elevation with EBM technique, in compact bone.
Inox WC
7
For sinus elevation with EBM technique, in soft bone.
11.5
Inox WC
6
To model the crestal portion of maxillary bones.
43
Maxillary sinus lift
Specific for the minor sinus lift technique with Omny implants; it allows you to
fracture the sinus cortical bone, raising it together with the membrane.
Inox
The insert suitable for the selected type of implant is inserted onto the hand piece.
Inox
2995.Y0.05
Surgical mallet
Inox
Lets you calibrate the force and concentrate it in a brief moment, thus obtaining
a precise fracture.
Suitable for easy access to the antral window, letting you carry out elevation of
the sinus endosteum.
44
Split crest
PPSU SI
Widener
Ti Nr. ø pilot hole ø ø ø ø ø ø
ø apical L. 8 L. 9 L. 10 L. 11 L. 12 L. 13-15
1 15702 2.0 2.20 2.25 2.30 2.35 2.45 2.50
2 15703 2.5 2.60 2.65 2.70 2.75 2.85 2.90
3 15704 2.8 2.95 3.00 3.10 3.15 3.25 3.30
4 15705 3.0 3.15 3.20 3.30 3.35 3.45 3.50
5 15706 3.5 3.60 3.70 3.75 3.85 3.90 4.00
6 15707 4.0 4.15 4.20 4.30 4.35 4.45 4.50
Allows you to gradually enlarge the crest, expanding the available bone and 13
reducing surgical trauma, increasing the transverse bone volume in the presence 11
of thin edentulous ridges with adequate height. 9
45
Bone regeneration
Ti
Ti Inox
For removing tacks from the holder and positioning them in situ, in combination
with the surgical mallet.
2.5 2.5
0.5 0.5
Tacks L L
3 11369 L
Ti 5 pc. pack 5 11370
PP Al
Contains tools and microscrews for fixing bone grafts, grids and plaques.
46
Drill stop SQ12 11359
SQ17 11360
PTFE 3 pc. pack
Lets you move the microscrews in frontal regions, allowing excellent control of
the direction and torque applied.
8 11376 1.2
11 11377
2
47
2.6
Microscrews SQ17 ø 1.7 L
9 11385
Ti 3 pc. pack 11 11386 L
13 11387
1.2
1.7
Biomaterials
48
100% smile makers
Geass is an Italian company which has achieved quality and innovation over the past thirty years, offering clinicians
implant-restorative solutions to obtain excellent results.
An internal production line, strict quality control and next generation technology are all guarantees of reliable,
safe and innovative products.
www.geass.it.
Keep updated with all the latest Geass news on the website.
shop.geass.it
A modern tool for your purchases, with countless new promotions.
Social media
News and updates on Geass products and events.
Smile club
Smile club is a loyalty program dedicated to implant customers that offers
access to exclusive benefits, giving even more value to clinicians and their
clinics.
49
Warnings and sales conditions
Warnings twelve-month warranty starting from the date reserves the right to make changes to
1. Manufacturer responsibility (as defined indicated on the transport document. Geass® products, catalogue contents and prices at
in Directive 93/42 EEC and subsequent is obliged to replace the quantity of product any time and without notice.
amendments) found to be defective due to manufacturing 3. Transport costs are to be borne by
The Omny Classics implant-restorative or origin. the customer. Goods travel at the risk of
system is a set of medical devices for dentistry The warranty shall be void and any the customer even when delivered DAP
in accordance with the Directive, aimed at compensation by the manufacturer is destination.
dental restoration in human oral cavities. The excluded in case of improper use of the 4. Delivery terms may undergo variations.
instruments and components dedicated to product, according to the cases listed in Any misunderstandings due to shipping
this purpose are an integral and indispensable paragraphs 1 (manufacturer responsibility inefficiencies cannot be attributed to Geass®.
part of the system and must therefore always ) and 2 (user responsibility). The return of 5. Geass® reserves the right to carry out
be used for the application of Omny Classics products under warranty must be previously partial deliveries.
dental implants, scrupulously in accordance agreed upon with the manufacturer and 6. The price list applied is the one valid at
with the instructions and recommendations accompanied by the documentation the time of order. Orders must be paid in
provided by the manufacturer (within the requested by Geass srl. Information on the the manner and within the terms agreed
meaning of the Directive). Any use of the existence of patents, trademark protection upon. In case of default, Geass® reserves the
Omny Classics system other than that rights or other intangible assets are not right to change the payment conditions for
described or the use of instruments or legally binding. subsequent supplies or to resort to any other
components other than those intended for 4. Documentation precautionary or executive measure for the
use or the use of instruments or components Brochures and detailed instructions for use total recovery of its credits.
not belonging to the system, produced by of Geass® dental implants must be requested 7. Any complaints relating to non-compliance
third parties, compromises the functionality from commercial representatives, area with the conditions of sale must be notified in
of the Omny Classics system and constitutes dealers or directly from the head office. writing to Geass® Customer Service within 8
"improper use", relieving the manufacturer of Customer Service: tel. +39 0432 669191 – (eight) days of receipt of the goods.
any obligation or responsibility. Information fax +39 0432 665323 e-mail: servizioclienti@ 8. Geass srl offers the possibility of replacing
on the use of Geass® products is provided geass.it - website: www.geass.it products purchased under the following
to users in writing by means of paper The information contained in them represents conditions:
documentation, such as instructions for the current state of the art known at the - Products of equal or greater amount (debit
use, surgical and restorative protocols, time of product marketing. This does not of any difference to be borne by the customer)
electronic means (audio-visual and IT tools) exonerate the user from the responsibility of - Within 12 months from the date of invoice
or practical demonstration (training courses). personally verifying the fitness of the product and within 6 months before the expiry date
They correspond to the current state of the for its intended purpose and procedures. indicated on the label
art at the time the product was marketed 5. Seminars and training courses - Undamaged residual product: complete
and are only a supplement to training and Geass® regularly organises seminars and and sealed original packaging
professional experience, as they are not training courses to help their product users - Product accompanied by a transport
sufficient for immediate use of Geass® learn and receive updated information on document and a copy of the purchase invoice
implant systems. the features and appropriate use of Geass® If the above conditions are not met, the
2. User responsibility implant systems. product will not be considered suitable
Choice and application of the product are 6. Product identification and will be returned to the sender with the
acts performed by the clinician with his All Geass® products can be identified by relative shipping costs charged. Geass srl
completely autonomous judgement and means of the item and batch numbers on the recognises the right of withdrawal within 14
according to the knowledge attributed to him labels accompanying the medical devices. working days from the date of delivery of the
by his/her medical profession qualification 7. Sales packaging goods.
and subsequent professional learning. No Unless otherwise stated in the catalogue, 9. Geass® declines all responsibility for any
liability can be attributed to Geass® for each product unit identified by the item errors committed unintentionally in the
damages of any kind arising from such number is sold in a single package. drafting of catalogues and price lists.
actions. The availability of technical-scientific 8. Delivery and availability 10. For anything not expressly foreseen in the
information to support the customer, in fact, Geass® products are sold to or on behalf general conditions of sale, the provisions of
does not release the user from the obligation of dentists and dental laboratories in Italian law shall apply. For any disputes, the
to personally verify the suitability of the accordance with their respective areas of Court of Udine - Italy is the competent body.
product for the purpose and procedures expertise. Some components may not be Document validity
provided. On the contrary, the user is obliged available in certain Countries or business This document substitutes the previous
to keep up to date on the development and areas. edition.
applications of Geass® implant systems. Any 9. Copyright
use of the system other than that stated Omny Classics is a registered trademark. Whole or partial reproduction of these
above is considered "improper use” and 10. Notes materials (texts and illustrations) without
relieves the manufacturer of any obligation For anything not mentioned in these warnings, written authorisation from Geass srl is
or responsibility. The user must contact please refer to the technical specifications, strictly prohibited.
the manufacturer and obtain explicit conditions of use and instructions contained
authorisation for uses not expressly foreseen in the Geass®information materials.
or recommended. Product processing, Ordering method
handling and application are outside the 1. When placing orders, always refer to the
control of the manufacturer and therefore item code.
fall under the responsibility of the user. 2. Orders received before 12:30 pm will be
For the endoral application of medical delivered within 24-48 hours, subject to
devices, it is advisable to always take the availability and except in certain areas.
appropriate precautions (i.e. dental dam) Conditions of sale
in order to eliminate the risk of accidental 1. These terms and conditions of sale are
inhalation. considered accepted by the customer on
3. Warranty placing of each order. Any change to these
Under the terms of the sales conditions, terms will only be valid if accepted by Geass®
the manufacturer guarantees that products in writing.
are free from defects. Geass® recognises a 2. In relation to market conditions, Geass®
50
51
Geass srl
Via Madonna della Salute, 23
33050 Pozzuolo del Friuli (UD) - I
tel +39 0432 669191 [email protected]
www.geass.it.
2019-09