EMC Test Report

Product Name: HUAWEI FusionCube

Product Model: FusionCube

Report Number: SYBH (E) 00914988EB

Reliability Laboratory of Huawei Technologies Co., Ltd.

Administration Building, Headquarters of Huawei Technologies Co., Ltd., Bantian, Longgang District,
Shenzhen, 518129, P.R.C
Tel: +86 755 28780808 Fax: +86 755 89652518
EMC Test Report of FusionCube Security Level: Internal use only

Notice
1. The laboratory has passed the accreditation by China National Accreditation Service for
Conformity Assessment (CNAS). The accreditation number is L0310.
2. The laboratory has passed the accreditation by The American Association for Laboratory
Accreditation (A2LA). The accreditation number is 2174.01.
3. The laboratory has been listed by the US Federal Communications Commission to perform
electromagnetic emission measurements. The site recognition number is 97456.
4. The laboratory has been listed by Industry Canada to perform electromagnetic emission
measurements. The recognition numbers of test site are 6369A-1 and 6369A-3.
5. The laboratory has been listed by the VCCI to perform EMC measurements. The accreditation
numbers of test site No.1 are R-3892, G-415, C-4361, and T-1348, and the accreditation numbers of
test site No.2 are R-3760, G-485, C-4210 and T-1237.
6. The test report is invalid if not marked with the signatures of the persons responsible for preparing
and approving the test report.
7. The test report is invalid if there is any evidence of erasure and/or falsification.
8. The test report is only valid for the test samples.
9. Content of the test report, in part or in full, cannot be used for publicity and/or promotional
purposes without prior written approval from the laboratory.

Report No.: SYBH (E) 00914988EB Huawei Proprietary and Confidential Page 2 of 31
Copyright © Huawei Technologies Co., Ltd
EMC Test Report of FusionCube Security Level: Internal use only

Applicant: Huawei Technologies Co., Ltd.


Address: Administration Building, Headquarters of Huawei Technologies Co.,
Ltd., Bantian, Longgang District, Shenzhen, 518129, P.R.C
Product Name: HUAWEI FusionCube
Product Model: FusionCube

Date of Receipt Sample: 2013-01-24


Start Date of Test: 2013-01-25
End Date of Test: 2013-02-02

Test Result: Pass

Approved by Senior 2013-05-14 Zhang Xinghai


Engineer: Date Name Signature

Prepared by: 2013-05-13 Liu Rui


Date Name Signature

Report No.: SYBH (E) 00914988EB Huawei Proprietary and Confidential Page 3 of 31
Copyright © Huawei Technologies Co., Ltd
EMC Test Report of FusionCube Security Level: Internal use only

Modification Record
No. Last Report No. Modification Description
1 N/A First report
2 SYBH(E)00680763EB Add two new test configurations TC3 and TC4.

Report No.: SYBH (E) 00914988EB Huawei Proprietary and Confidential Page 4 of 31
Copyright © Huawei Technologies Co., Ltd
EMC Test Report of FusionCube Security Level: Internal use only

Content
1 General Information ................................................................................................................. 6
1.1 Applied Standard ..................................................................................................................... 6
1.2 Test Location ........................................................................................................................... 6
1.3 Test Environment Condition .................................................................................................... 6
2 Summary of Test Results ........................................................................................................ 7
3 Equipment Specification .......................................................................................................... 8
3.1 General Description ................................................................................................................. 8
3.2 Specification............................................................................................................................. 8
3.3 Board and SubAssembly ....................................................................................................... 10
4 System Configuration during EMC Test ................................................................................ 12
4.1 Ports and Cables ................................................................................................................... 12
4.2 Auxiliary Equipment ............................................................................................................... 12
4.3 Test Configurations................................................................................................................ 12
4.4 Test Conditions and Connections.......................................................................................... 16
5 Details of Test Items .............................................................................................................. 20
5.1 Radiated Emission 30 MHz to 40 GHz .................................................................................. 20
5.2 Conducted Disturbance 0.15 MHz to 30 MHz ....................................................................... 22
6 Main Test Instruments ........................................................................................................... 23
7 System Measurement Uncertainty ........................................................................................ 23
8 Graph and Data of Emission Test ......................................................................................... 24
8.1 Radiated Disturbance ............................................................................................................ 24
8.2 Conducted Disturbance ......................................................................................................... 28
9 Photographs of Test Set-up ................................................................................................... 29
9.1 Radiated Emission ................................................................................................................. 29
9.2 Conducted Emission .............................................................................................................. 30
Appendix: Abbreviation ........................................................................................................................ 31

Report No.: SYBH (E) 00914988EB Huawei Proprietary and Confidential Page 5 of 31
Copyright © Huawei Technologies Co., Ltd
EMC Test Report of FusionCube Security Level: Internal use only

1 General Information

1.1 Applied Standard


Applied Product Standard: FCC CFR47 Part 15 Subpart B:2012
ICES-003 Issue 5:2012

Test Method: ANSI C63.4:2003


1.2 Test Location
Test Location 1: Reliability Laboratory of Huawei Technologies Co., Ltd.
Address: Administration Building, Headquarters of Huawei Technologies
Co., Ltd., Bantian, Longgang District, Shenzhen, 518129, P.R.C

1.3 Test Environment Condition


Ambient Temperature: 20-25°C
Relative Humidity: 45-55%
Atmospheric Pressure: 101kPa

Report No.: SYBH (E) 00914988EB Huawei Proprietary and Confidential Page 6 of 31
Copyright © Huawei Technologies Co., Ltd
EMC Test Report of FusionCube Security Level: Internal use only

2 Summary of Test Results

Table 1 Summary of test results


EUT Classification:
Class A Digital Device
Test Test
Test Items Limit Location
Configuration Result
Radiated Emissions
TC1-TC3 Class A Pass Location1
Enclosure Port

Conducted Emissions
TC1,TC2 Class A Pass Location1
AC Power Port

Note:
1, Measurement taken is within the uncertainty of measurement system.
2, TC = Test configuration

Report No.: SYBH (E) 00914988EB Huawei Proprietary and Confidential Page 7 of 31
Copyright © Huawei Technologies Co., Ltd
EMC Test Report of FusionCube Security Level: Internal use only

3 Equipment Specification
3.1 General Description

The FusionCube is an enterprise integrated cloud platform. The FusionCube solution provides the
universal FusionCube or infrastructure FusionCube that helps enterprises to increase core service
efficiency and achieve optimal total cost of ownership (TCO). The FusionCube implements hardware
sharing, decoupling of software from hardware, and rapid deployment of services and applications.

The FusionCube can be sold as an independent product. However, in most cases it is promoted as a
platform that can be flexibly deployed with application components, such as virtual desktop
infrastructure (VDI), Exchange, Sharpoint, and SQL Server, on the platform. Typical application
scenarios include the following:

 Enterprise OA FusionCube

The FusionCube runs enterprise office automation (OA) applications, such as Microsoft Exchange
and Sharepoint.

 ERP/CPM FusionCube

The FusionCube runs Enterprise Resource Planning (ERP) or Customer Relationship Management
(CRM) applications, such as Kingdee and UF financial software.

 VDI FusionCube

The FusionCube runs VDI virtual desktops or virtual applications.

 Database FusionCube

The FusionCube runs database software, such as Microsoft SQL Server or SAP Sybase.

 Universal FusionCube

The FusionCube incorporates servers, storage devices, network devices, and virtualization software
without application software.

The FusionCube solution applies to small, medium-sized, and large enterprises.

3.2 Specification
Table 2 Main equipment specification
Rated Input Voltage 1.2m:~200-240V AC, 50/60Hz,16A
2.0m:~200-240V AC, 50/60Hz,32A (Max)
~346-415V AC, 3W+N,50/60Hz,32A (Max) /PH Per Input
Rated Power (W) 1.2m:~200-240V AC, 50/60Hz,6400 W
2.0m:~200-240V AC, 50/60Hz,12000 W(Max)
~346-415V AC, 50/60Hz,18000 W(Max)
Dimensions (W x D 1.2m:600mm(W)*1100mm(D)*1200mm(H)
x H) 2.0m:600mm(W)*1200mm(D)*2000mm(H)
Weight (kg) 1.2m:530kg
2.0m:959kg
Frequency of the 0.032768MHz,0.1MHz,14.32MHz,17.8MHz,24MHz,25MHz,26MHz,27MHz,28.
Internal Source 64MHz,32.77MHz,33MHz,48MHz,50MHz,66.67MHz,75MHz,96MHz,100MHz,

Report No.: SYBH (E) 00914988EB Huawei Proprietary and Confidential Page 8 of 31
Copyright © Huawei Technologies Co., Ltd
EMC Test Report of FusionCube Security Level: Internal use only

(MHz) 125MHz,133MHz,150MHz,167MHz,200MHz,267MHz,333MHz,400MHz,533M
Hz,1GHz,2.5GHz,2.95GHz,3.125GHz,3.75GHz,5GHz,10.3125GHz,

Figure 1. EUT Appearance of 1.2m Cabinet

Figure 2. EUT Appearance of 2.0m Cabinet

Report No.: SYBH (E) 00914988EB Huawei Proprietary and Confidential Page 9 of 31
Copyright © Huawei Technologies Co., Ltd
EMC Test Report of FusionCube Security Level: Internal use only

3.3 Board and SubAssembly


Table 3 Subassembly list
Subassembly
Subassembly Description
Model Manufacturer
Name
SHENZHEN
PDU32-1PH- Input voltage:~220-240 V/50/60HZ
PDU (2.0M) HAIPENGXIN
20/4B Rate power:7300W
Electronics Co., Ltd
Shenzhen Zhong
Yuan
PDU32- Input voltage:~220-240 V/50/60HZ
Alternative Tong Power
1PH- 20/4B Rate power:7300W
Supply Techonlongy
Co., Ltd
SHENZHEN
Input voltage:~220-240 V/50/60HZ
PDU (1.2M) PDU16-1-6B HAIPENGXIN
Electronics Co., Ltd Rate power:3500W
Shenzhen Zhong
Yuan
Input voltage:~220-240 V/50/60HZ
Alternative PDU16-1-6B Tong Power
Supply Techonlongy Rate power:3500W
Co., Ltd
SHENZHEN
PDU32-1PH- Input voltage:~220-240 V/50/60HZ
PDU (2.0M) HAIPENGXIN
9/4-B1 Rate power:6000W
Electronics Co., Ltd
Shenzhen Zhong
Yuan
PDU32-1PH- Input voltage:~220-240 V/50/60HZ
Alternative Tong Power
9/4-B1 Rate power:6000W
Supply Techonlongy
Co., Ltd
SHENZHEN Input voltage: ~346-415V AC,
PDU32-3PH-
PDU (2.0M) HAIPENGXIN 3W+N,50/60Hz
12/9-B
Electronics Co., Ltd Rate power:18000W
Shenzhen Zhong
Yuan Input voltage: ~346-415V AC,
PDU32-3PH-
Alternative Tong Power 3W+N,50/60Hz
12/9-B
Supply Techonlongy Rate power:18000W
Co., Ltd
Quidway
LanSwitch Huawei 48-port FE interface Lan Switch
S5352C-EI
Quidway
LanSwitch S5700-52C- Huawei 48-port FE interface Lan Switch
EI
Quidway
LanSwitch Huawei 48-port GE interface Lan Switch
S6700-48-EI
Access SVN5560 Security Vitual Network (optional)
Huawei
Gateway
Eudemon
Firewall Huawei Quidway Eudemon series(optional)
1000E-X
9.2 Build
NetScaler Huawei Loadbalance and Access Gateway
53.2
DAE12425U S6800T,STLZ07DME,DAE12425U2-01
Storage Huawei
2 Disk Enclosure
DAE12435U S6800T,STLZ09DME,DAE12435U4-03
Storage Huawei
4 Disk Enclosure
S5500T OceanStor Huawei Storage equipment

Report No.: SYBH (E) 00914988EB Huawei Proprietary and Confidential Page 10 of 31
Copyright © Huawei Technologies Co., Ltd
EMC Test Report of FusionCube Security Level: Internal use only

S5500T
E6000 Tecal E6000 Huawei Hardware Server
NX112 S5328C-EI Huawei Switch mode for E6000
OSCA-
CX310 IT11XCUB00 Huawei Switch mode for E9000
-CX310
E9000 Tecal E9000 Huawei Hardware Server
600mm(W)*1100mm(D)*1200mm(H);Unshi
Cabinet(1.2m) FR24611C Huawei
elded
600mm(W)*1200mm(D)*2000mm(H);Unshi
Cabinet(2.0m) FR24612C Huawei
elded

Report No.: SYBH (E) 00914988EB Huawei Proprietary and Confidential Page 11 of 31
Copyright © Huawei Technologies Co., Ltd
EMC Test Report of FusionCube Security Level: Internal use only

4 System Configuration during EMC Test


The Equipment under Test (EUT) was functioning correctly during all tests. The EUT was installed
within the test site and was configured to simulate a typical configuration.

4.1 Ports and Cables


Table 4 Ports and cables
Port Connector Length Qty. Type of Cable Remark
AC Power Port 2m 1 Unshielded Power Supplied
10GE SFP+ 10m 4 Single-mode fiber
FE RJ45 3m 8 STP-5 Indoor signal port
Console RJ45 1m 1 STP-5,
Earth 3m 1 Earthing cable

4.2 Auxiliary Equipment


Table 5 Auxiliary equipment
Calibration
Calibration
Equipment Model Manufacturer S/N Interval Remark
Date
(month)
Personal PIII1G/128 SZ10001
LEGEND N/A N/A N/A
Computer M/30G/15" 67639

4.3 Test Configurations


The equipment under test (EUT) was connected to ancillary devices in order to simulate normal
operating conditions (with reference to the guidance given in the standard for this type of equipment).
There were four test configurations.TC1,TC2,TC3 and TC4 were shown in the following tables and
figures:
Table 6 Test configuration
Configuration No. Configuration Description
TC1 1.2m(E6000): ~200-240V AC, 50/60Hz,16A
TC2 2.0m(E6000):~200-240V AC, 50/60Hz,32A,
TC3 2.0m(E9000):~200-240V AC, 50/60Hz,32A
TC4 2.0m(E9000):~346-415V AC, 50/60Hz,32A

Report No.: SYBH (E) 00914988EB Huawei Proprietary and Confidential Page 12 of 31
Copyright © Huawei Technologies Co., Ltd
EMC Test Report of FusionCube Security Level: Internal use only

Figure 3. : Test configuration1 (TC1)

Report No.: SYBH (E) 00914988EB Huawei Proprietary and Confidential Page 13 of 31
Copyright © Huawei Technologies Co., Ltd
EMC Test Report of FusionCube Security Level: Internal use only

Figure 4. : Test configuration2 (TC2)

42U P P Filler Panel P P


41U D D S6724(S6324)/S6748(S6348) D D
40U U U Cabling Through U U
39U S6724(S6324)/S6748(S6348)
38U Cabling Through
37U S5728(S5328)/S5752(S5352)
36U Cabling Through
35U S5728(S5328)/S5752(S5352)
34U Cabling Through
33U
32U
31U StorageSystem
30U (4U/24HDD/3.5")
29U

Report No.: SYBH (E) 00914988EB Huawei Proprietary and Confidential Page 14 of 31
Copyright © Huawei Technologies Co., Ltd
EMC Test Report of FusionCube Security Level: Internal use only

28U
27U
26U 1 1 StorageSystem 1 1
25U P P (4U/24HDD/3.5") P P
24U H H H H
23U 3 3 Filler Panel 3 3
22U 2 2 StorageSystem 2 2
21U A A (2U/24HDD/2.5") A A
20U StorageSystem
19U (2U/24HDD/2.5")
18U StorageSystem
17U (2U/24HDD/2.5")
16U S5500T
15U (2U/24HDD/2.5")
14U Filler Panel
13U
12U
11U
10U
9U
8U
E9000
7U
6U
5U
4U
3U
2U
1U Filler Panel
Figure 5. : Test configuration3 (TC3)

42U P Filler Panel P


41U D Filler Panel D
40U U Filler Panel U
39U
38U
37U
36U
35U
34U
E9000-3
33U
32U
31U
30U
29U
28U
27U Filler Panel
26U 3 E9000-2 3

Report No.: SYBH (E) 00914988EB Huawei Proprietary and Confidential Page 15 of 31
Copyright © Huawei Technologies Co., Ltd
EMC Test Report of FusionCube Security Level: Internal use only

25U P P
24U H H
23U 3 3
22U 2 2
21U A A
20U
19U
18U
17U
16U
15U
14U Filler Panel
13U
12U
11U
10U
9U
8U
E9000-1
7U
6U
5U
4U
3U
2U
1U Filler Panel
Figure 6. : Test configuration4 (TC4)

4.4 Test Conditions and Connections


FusionCube solution is designed for enterprise OA or enterprise VDI. In this solution, The VDI
FusionCube allows enterprise users to deal with their office work (such as sending or receiving emails
and editing documents) by using the desktop cloud and provides various security schemes to ensure
information security in offices. FusionCube is the infrastructure of the desktop cloud in this solution, it
consolidates computing, storage, and network resources, offers a unified interface for operation,
management, and maintenance, it also offers features, such as memory over commitment, thin
provisioning, time division multiplexing (TDM), scheduled power off, and load balancing, to implement
on-demand allocation of memory, CPU and storage resources.

Report No.: SYBH (E) 00914988EB Huawei Proprietary and Confidential Page 16 of 31
Copyright © Huawei Technologies Co., Ltd
EMC Test Report of FusionCube Security Level: Internal use only

PWR S5352-EI TC
200-240V AC 16A

PWR
S5352-EI

PWR SVN5530(Optional)

PWR

E1000E(Optional)
PGND
PWR
NetScaler(Optional)

PWR

S5500T

PWR

E6000

Figure 7. Test connection of TC1

Report No.: SYBH (E) 00914988EB Huawei Proprietary and Confidential Page 17 of 31
Copyright © Huawei Technologies Co., Ltd
EMC Test Report of FusionCube Security Level: Internal use only

PWR S5352-EI TC
200-240V AC 32A

PWR
S5352-EI

PWR SVN5530(Optional)

PWR

E1000E(Optional)
PGND
PWR
NetScaler(Optional)

PWR
StorageSystem

PWR
S5500T

PWR

E6000

Figure 8. Test connection of TC2

S6700_2

S6700_1

S5700_2

S5700_1
PC

S5500T

E9000

Figure 9.Test connection of TC3

Report No.: SYBH (E) 00914988EB Huawei Proprietary and Confidential Page 18 of 31
Copyright © Huawei Technologies Co., Ltd
EMC Test Report of FusionCube Security Level: Internal use only

E9000-3

PC
E9000-2

E9000-1

Figure 10. Test connection of TC4

Report No.: SYBH (E) 00914988EB Huawei Proprietary and Confidential Page 19 of 31
Copyright © Huawei Technologies Co., Ltd
EMC Test Report of FusionCube Security Level: Internal use only

5 Details of Test Items


5.1 Radiated Emission 30 MHz to 40 GHz
5.1.1 Test Procedure
The test site semi-anechoic chamber has met the requirement of NSA tolerance 4 dB according to
the standards: ANSI C63.4. The test distance was 3m and 10m.The set-up and test methods were
according to ANSI C63.4 and CAN/CSA-CEI/IEC CISPR 22

A preliminary scan and a final scan of the emissions were made from 30 MHz to 40GHz by using test
script of software; the emissions were measured using Quasi-Peak Detector (30 MHz to1 GHz) and
AV detector (above 1 GHz). The maximal emission value was acquired by adjusting the antenna
height, polarisation and turntable azimuth in accordance with the software setup. Normally, the height
range of antenna was 1 m to 4 m, the azimuth range of turntable was 0°to 360°, The receive antenna
has two polarizations V and H.

The test set-up is shown in diagram as below:

Semi-Anechoic Chamber

Antenna MAX:4 m

EUT
Preamplifier
MIN:1 m

signal cable

AE H=0.1m GRP
Ferrite Clamp
Receiver

Figure 11. Test set-up of radiated disturbance (30 MHz-1 GHz)

Report No.: SYBH (E) 00914988EB Huawei Proprietary and Confidential Page 20 of 31
Copyright © Huawei Technologies Co., Ltd
EMC Test Report of FusionCube Security Level: Internal use only

Semi-Anechoic Chamber

MAX:4 m
Antenna
EUT

MIN:1 m
signal cable Preamplifier

AE H=10cm GRP Receiver


Ferrite Clamp

Figure 12. Test set-up of radiated disturbance (above 1 GHz)

5.1.2 Test Results


The EUT has met the requirements for radiated emission of enclosure port.
For the test data, see section 8.1.
Table 7 Test Limits for FCC Part 15 at a measuring distance of 10m
Frequency range 30 MHz to 1 GHz
Measuring distance 10 m
Classification Class A
Limits(Class A) 30 MHz to 88 MHz 39.0 dBµV/m
88 MHz to 216 MHz 43.5 dBµV/m
216 MHz to 960 MHz 46.4 dBµV/m
960 MHz to 1 GHz 49.5 dBµV/m

Table 8 Test Limits for FCC Part 15 at a measuring distance of 3m


Frequency range 1 GHz to 40 GHz
Measuring distance 3m
Classification Class A
Limits(Class A) 1 GHz to 18 GHz 59.5 dBµV/m
Note: The highest frequency of the internal sources of the EUT is 10.3125 GHz, the measurement
was made up to 40 GHz.

Report No.: SYBH (E) 00914988EB Huawei Proprietary and Confidential Page 21 of 31
Copyright © Huawei Technologies Co., Ltd
EMC Test Report of FusionCube Security Level: Internal use only

5.2 Conducted Disturbance 0.15 MHz to 30 MHz


5.2.1 Test Procedure
The EUT was configured as described in section 4. The mains cable of the EUT must be connected
to LISN. The LISN shall be placed 0.8 m from the boundary of EUT and bonded to a ground
reference plane for LISN mounted on top of the ground reference plane. This distance is between the
closest points of the LISN and the EUT. All other units of the EUT and associated equipment shall be
at least 0.8m from the LISN.

Ground connections, where required for safety purposes, shall be connected to the reference ground
point of the LISN and, where not otherwise provided or specified by the manufacturer, shall be of
same length as the mains cable and run parallel to the mains connection at a separation distance of
not more than 0.1 m.

The test set-up is shown in diagram as below:

Shielding room

0.4m

RF cable
EUT
able
Po wer c
Receiver
Power input LISN 0.8m
10cm
GRP
Grounding cable D≤10cm

Figure 13. Test set-up of conducted disturbance for power port


5.2.2 Test Results
The EUT has met the requirements of FCC Part15 and ICES 003 for Conducted Disturbance of AC
Power Port
For the test data, see section 8.2.
Table 9 Limits of AC power port
Frequency range 150 kHz to 30 MHz
Classification Class A
Limits(Class A) Voltage limits (dBµV)
(Frequency) QP AV
0.15 to 0.5 MHz 79 66
0.5 to 30 MHz 73 60

Report No.: SYBH (E) 00914988EB Huawei Proprietary and Confidential Page 22 of 31
Copyright © Huawei Technologies Co., Ltd
EMC Test Report of FusionCube Security Level: Internal use only

6 Main Test Instruments


Table 10 Main test instrument
Calibration
Test Calibration
Test Instrument Model Manufacturer Interval
Item Date
(Month)
EMI test receiver ESU26 R&S 2012-05-14 12
CBL6112D
Bilog antenna TESEQ 2012-01-23 12
(30995)
Radiated Horn antenna HF907
R&S 2012-06-08 24
emission (1 to 18GHz) (100174)
(K3 10m Horn antenna
chamber) HL050 R&S 2012-04-07 24
(18 to 26.5GHz)
Horn antenna BBHA SAS-
Ahsystems 2012-12-19 12
(26.5 to 40GHz) 573
Chamber _NSA 10m chamber Albatross 2011-03-05 24

EMI test receiver ESMI R&S 2012-05-14 12


Conducted
emission Artificial mains
ENV4200 R&S 2012-05-14 12
network
Software Information
Software
Test Item Manufacturer Version
Name
Radiated emission EP7 Toyo V5.3

Conducted emission ES-K1 R&S V1.7.1

7 System Measurement Uncertainty

For a 95% confidence level, the measurement expanded uncertainties for defined systems, in
accordance with the recommendations of ISO 17025 were:

Table 11 System measurement uncertainty


Items Extended Uncertainty
U=4.8 dB; k=2 (30 MHz to 1 GHz)
Radiated emission Field strength (dBµV/m)
U=4.3 dB; k=2 (1 GHz to 40 GHz)
Disturbance Voltage
Conducted Emission U=3.3 dB; k=2
(dBμV)

Report No.: SYBH (E) 00914988EB Huawei Proprietary and Confidential Page 23 of 31
Copyright © Huawei Technologies Co., Ltd
EMC Test Report of FusionCube Security Level: Internal use only
<<Radiated Emission>> Huawei
RE2012082004.dat
8 Graph and Data of Emission Test
ReportHeader : GCTC EMC Lab Limit : FCC Class A up to 26.5G 3m -4dB
8.1 Radiated:Disturbance
Operator CHY Date, Time : 20 August,2012 16:58
EUT : X6000 EUT Power : AC 220V
Model Radiated
8.1.1 : Disturbance (30MHz—1GHz) Temp, Humid : 25Degree;56%'RH
Serial Numbe : Comment :
[dB(uV/m)]
120 <FCC Part 15 Class A 10m_30M_1G>
PK
110 QP
<RE2012082004>
100 Range(H,PK)
Range(V,PK)
90 Suspected Item(H)
Suspected Item(V)
80 Final Item(H,QP)
Final Item(V,QP)
70
Level

60

50

40

30

20

10

0
30 50 100 500 1000
Frequency [MHz]

Final Result

No. Frequency (P) Reading c.f Result Limit Margin Height Angle
QP QP QP QP
[MHz] [dB(uV)] [dB(1/m)] [dB(uV/m)] [dB(uV/m)] [dB] [cm] [deg]
1 499.997 H 60.2 -22.0 38.2 46.4 8.2 203.0 53.0
2 130.797 V 52.2 -30.2 22.0 43.5 21.5 100.0 0.0
3 699.974 H 51.1 -19.8 31.3 46.4 15.1 151.0 108.0
4 299.978 V 49.1 -27.5 21.6 46.4 24.8 349.0 0.0
5 499.992 V 54.4 -22.3 32.1 46.4 14.3 150.0 176.0
6 899.959 V 52.2 -18.2 34.0 46.4 12.4 185.0 184.0

Note:
1. Result =Reading level by receiver + Transd (Antenna factor + cable loss – preamplifier gain)
2. The test configuration TC1-TC4 were tested, but the worst result is supplied.

Report No.: SYBH (E) 00914988EB Huawei Proprietary and Confidential Page 24 of 31
Copyright © Huawei Technologies Co., Ltd
<<Radiated Emission Test Data>> Huawei
RE2012083003.dat

ReportHeader : GCTC EMC Lab Limit : FCC Class A up to 26.5G 3m -4dB


Operator : LLJ
EMC Test Report of FusionCube Date, Time : Security
30 August,2012 12:26
Level: Internal use only
EUT : RH4885 EUT Power : AC 220V
Modal : Temp, Humid : 25Degree;56%RH
Serial : Comment :
8.1.2 Radiated Disturbance (1 GHz—18GHz)
[dB(uV/m)]
80 <FCC Part 15 Class A 3m_1G_40G>
PK
AV
70 <RE2012083003>
Range(H,PK)
Range(V,PK)
60 Suspected Item(H)
Suspected Item(V)
Final Item(H,AV)
50 Final Item(V,AV)
Level

40

30

20

10

0
1000 2000 5000 10000 18000
Frequency [MHz]

Final Result

No. Frequency (P) Reading c.f Result Limit Margin Height Angle
AV AV AV AV
[MHz] [dB(uV)] [dB(1/m)] [dB(uV/m)] [dB(uV/m)] [dB] [cm] [deg]
1 1147.419 V 45.1 -13.1 32.0 59.5 27.5 121.0 201.0
2 1565.796 V 54.0 -10.0 44.0 59.5 15.5 189.0 204.0
3 1600.052 V 51.3 -9.8 41.5 59.5 18.0 101.0 177.0
4 3199.942 V 38.1 -1.6 36.5 59.5 23.0 101.0 175.0
5 6400.449 V 30.6 6.6 37.2 59.5 22.3 137.0 231.0
6 13065.740 H 29.8 20.1 49.9 59.5 9.6 101.0 109.0

Note:
1. Result =Reading level by receiver + Transd (Antenna factor + cable loss – preamplifier gain)
2. The test configuration TC1-TC4 were tested, but the worst result is supplied.

Report No.: SYBH (E) 00914988EB Huawei Proprietary and Confidential Page 25 of 31
Copyright © Huawei Technologies Co., Ltd
EMC Test Report of FusionCube Security Level: Internal use only

8.1.3 Radiated Disturbance (18 GHz—26.5GHz)

Note:
1. Result =Reading level by receiver + Transd (Antenna factor + cable loss – preamplifier gain)
2. The test configuration TC1-TC4 were tested, but the worst result is supplied.

Report No.: SYBH (E) 00914988EB Huawei Proprietary and Confidential Page 26 of 31
Copyright © Huawei Technologies Co., Ltd
EMC Test Report of FusionCube Security Level: Internal use only

8.1.4 Radiated Disturbance (26.5 GHz—40 GHz)

Note:
1. Result =Reading level by receiver + Transd (Antenna factor + cable loss – preamplifier gain)
2. The test configuration TC1-TC4 were tested, but the worst result is supplied.

Report No.: SYBH (E) 00914988EB Huawei Proprietary and Confidential Page 27 of 31
Copyright © Huawei Technologies Co., Ltd
EMC Test Report of FusionCube Security Level: Internal use only

8.2 Conducted Disturbance


8.2.1 AC Power Port Test Data

Level [dBµV]

80
70
60 x
x
50 + x x x
+ +
40 + +
x
30 +
20
10
0 150k 300k 500k 1M 2M 3M 5M 7M 10M 30M
Frequency [Hz]

Measurement Result: QP Detector


Frequency Level Transd Limit Margin Line PE
(MHz) (dBµV) (dB) (dBµV) (dB)
0.159000 56.40 20.5 79 22.6 L1 GND
0.694500 57.50 20.5 73 15.5 L1 GND
1.059000 51.60 20.6 73 21.4 L1 GND
3.111000 37.60 20.7 73 35.4 L1 GND
11.548500 51.60 20.5 73 21.4 L1 GND
20.940000 49.90 20.6 73 23.1 N GND

Measurement Result: AV Detector


Frequency Level Transd Limit Margin Line PE
(MHz) (dBµV) (dB) (dBµV) (dB)
0.348000 50.00 20.5 66 16.0 L1 GND
0.694500 47.90 20.5 60 12.1 N GND
1.036500 45.60 20.6 60 14.4 N GND
2.517000 30.70 20.6 60 29.3 L1 GND
11.548500 39.70 20.5 60 20.3 L1 GND
20.724000 41.60 20.6 60 18.4 L1 GND

Note:
1. Level= Reading level+ Transd (cable loss + correction factor)
The reading level is used to calculate by software which is not shown in the sheet.
2. The test configuration TC1, TC2, TC3 and TC4 were tested, but the worst result is supplied.

Report No.: SYBH (E) 00914988EB Huawei Proprietary and Confidential Page 28 of 31
Copyright © Huawei Technologies Co., Ltd
EMC Test Report of FusionCube Security Level: Internal use only

9 Photographs of Test Set-up

9.1 Radiated Emission

Radiated emission for 30 MHz-1 GHz

Radiated emission (above 1 GHz)

Report No.: SYBH (E) 00914988EB Huawei Proprietary and Confidential Page 29 of 31
Copyright © Huawei Technologies Co., Ltd
EMC Test Report of FusionCube Security Level: Internal use only

9.2 Conducted Emission

Conducted emissions of AC power port

Report No.: SYBH (E) 00914988EB Huawei Proprietary and Confidential Page 30 of 31
Copyright © Huawei Technologies Co., Ltd
EMC Test Report of FusionCube Security Level: Internal use only

Appendix: Abbreviation

Table 12 Abbreviation
Abbreviation Full Name
EMC Electromagnetic Compatibility
EMI Electromagnetic Interference
EUT Equipment Under Test
AE Auxiliary Equipment
AC Alternate Current
DC Direct Current
NSA Normalized Site Attenuation
LISN Line Impedance Stabilization Network
TC Test configuration
N/A Not Applicable

END

Report No.: SYBH (E) 00914988EB Huawei Proprietary and Confidential Page 31 of 31