The Smiths Medical PM, Inc.

ADVANTAGE
BCI ® 3303 HAND-HELD PULSE OXIMETER
• 3 operating
modes enhance
user convenience
• Allows menu-free
operation via one-
Exceptional
touch, direct-function
keys flexibility
• Easily adjust LED
display brightness
from the
to optimize viewing
• Pulse strength bar
hand-held
on screen
• Adjustable alarm
pulse oximetry
limits for SpO2 and
pulse rate leader.
• Instantly distinguish
between audible
patient alarms and
system alerts
• View patient
history on-screen;
recall up to 99
patient SpO2 and
pulse rate readings
with 24-hr memory
• Protective rubber
boot included
• Pole mount available
• Internal rechargeable
NiMH battery
• Genuine BCI® reusable
& disposable sensors
available

The BCI® 3303 HAND-HELD PULSE OXIMETER facilitates spot checking and continuous
SpO2 and pulse rate monitoring for home-care use, as well as at the hospital bedside
or for land or air transport situations. Stores data for later sleep study analysis via
a PC or commercially available printer. It’s precisely the kind of inspired design you’d
expect from the global leader in hand-held pulse oximetry technology. For more
information, visit smiths-medical.com.
BCI® 3303 HAND-HELD PULSE OXIMETER
SPECIFICATIONS:
Displays, Indicators & Keys: Power:
SpO2 LED numeric display AC Power 105-125V ~ 60Hz
0.43 inch (11 mm) high Optional 207-253V ~ 50Hz, 90-110V ~ 50Hz
Pulse Rate LED numeric display Battery Standard NiMH (Nickel Metal Hydride)
0.375 inch (9.5 mm) high Battery Life Internal rechargeable, not user
Pulse Strength Logarithmically scaled 8-segment replaceable. Fully charges in about
LED bar graph 6 hours. Approximately 24 hours of
Low Battery LED flashes when approximately continuous use.
30 minutes of battery life remains
Environment:
Alarm Silence LED flashes or lights to remind the
user that audio alarms are disabled Operating Temperature -4°F to 131°F (-20°C to 55°C)
Sensor LED flashes to alert the operator to Storage Temperature -40°F to 167°F (-40°C to 75°C)
check the SpO2 sensor placement Relative Humidity 10-95% (storage)
(non-condensing) 15-95% (operating)
SpO2 :
Mechanical Durability Test Results:
Range 0-100%
Accuracy ±2% at 70-100%; ±3% at 50-69% Vibration Testing In compliance with
IEC 68-2-6, IEC 68-2-34
Averaging 4, 8, or 16 pulse beat average
Shock Testing In compliance with
Alarm Range High - 50%-100% & OFF (1% steps)
IEC 68-2-27
Low - OFF & 50%-99% (1% steps)
Drop Testing Exceeded UL 544 testing
Pulse Rate: recommendations
Range 30-254 bpm Standards:
Accuracy ±2% at 30-254 bpm
EN60601-1, EN60601-1-2, CSA Std. C22.2 No. 125, UL 544
Resolution 1 bpm
Alarm Range High - 5-250 bpm & OFF (5 bpm steps) Regulatory Compliance:
Low - OFF & 5-250 bpm (5 bpm steps) 510(k): K945754
Memory:
Spot checks and trends can be stored for up to 99 patients
and 24 hours of run time.
Auxiliary Serial Printer/Computer Output: ISO 9001/ISO 13485
Data saved every thirty seconds can be printed or Catalog Number:
downloaded to a PC (trend).
3303 Hand-Held Pulse Oximeter
Data saved every four seconds in sleep mode can be
output and processed by commercially available sleep
study software.
Physical:
Dimensions 7.25” H x 3.3” W x 1.85” D
18.4 cm x 8.4 cm x 4.7 cm
Weight 19 oz. (539 grams)
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
Please read the Instructions for Use supplied with the product
for detailed instructions, warnings, and cautions.

Q-Line for U.S.A. Customers call 1-800-348-1842 for emergency and clinical application information 24 hours a day, 365 days a year.
Experienced Clinical Specialists will return your call and assist with any questions you may have.
For more information, please call Smiths Medical PM, Inc. Patient Monitoring and Ventilation at 262-542-3100 or 800- 558- 2345
or your Smiths Medical distributor

Smiths Medical PM, Inc.


Patient Monitoring and Ventilation
N7 W22025 Johnson Drive, Waukesha, Wisconsin 53186 USA
Phone: 262-542-3100 Fax: 262-542-0718 Toll-Free: 800-558-2345
www.smiths-medical.com
The product described is covered by U.S. Patent No. 5,437,275
BCI is a trademark of the Smiths Medical family of companies
The symbol ® indicates it is registered in the U.S. Patent and Trademark Office and certain other countries.
© 2004 Smiths Medical family of companies. All rights reserved
BCI 3303 Rev 04 10/04