Installation instruction 524 013

Sensor-CASSY 2 (524 013)


Power-CASSY (524 011)
Profi-CASSY (524 016)
CASSY Lab 2 (524 220)

1 Technical data 2 Description


Please take the technical data of the different CASSY modules The computer-assisted measuring and evaluation system
from the CASSY Lab 2 online documentation. CASSY consists of the CASSY Lab 2 software (524 220) and
one or several Sensor-CASSY 2 modules (524 013) and/or
Power-CASSY (524 011), which can be connected to a com-
Safety notes puter via a USB port. Alternatively the modules can be used
without a computer if the CASSY-Display (524 020) is em-
At the present state of software engineering, it is not possi- ployed. Depending on the requirements of the measurement, up
ble to guarantee faultlessness of a product. LD DIDACTIC to eight Sensor-CASSY 2 or Power-CASSY modules can be
GmbH therefore does not take responsibility for damage that cascaded.
is caused by the installation or the use of CASSY Lab 2 . CASSY Lab 2 also supports other devices which are connected
to the serial interface of a computer (e.g. electronic balances, IR
position detector) and can be used independently of CASSY.
For your own security as regards electricity: 3 Installation
CASSY is connected to a computer with the enclosed USB
• Do not connect the 4 mm Sockets of Sensor-CASSY 2
cable via a USB port.
(524 013) to voltages over 250 V (CAT II).
If possible, only use the enclosed plug-in unit (12V/1.6A) for
• Do connect the inputs of Profi-CASSY (524 016) to volt- power supply.
ages over 30 V.
Several CASSY modules are cascaded by plugging them to-
• Do not connect the Outputs of any CASSY-Module to gether and thus only require one USB port. Depending on the
external voltage sources. power consumption, one or two Sensor-CASSY 2 modules can
be supplied from one plug-in unit. If more than two modules are
Several CASSY modules can be cascaded by plugging used, additional plug-in units have to be connected.
them together. If the cascade is not mounted in an experi- The CASSY Lab 2 software can be run on Windows XP/Vista/7
ment frame, the mechanical stability of this coupling is suffi- systems.
cient for experimenting but not for transport.
CASSY Lab 2 is installed automatically by inserting the
• Only transport cascaded CASSY modules which are CASSY Lab 2 CD-ROM or manually by starting the file
mounted in an experiment frame. SETUP.EXE and by following the instructions on the screen.
or
• Transport CASSY modules separately.

A Sensor-CASSY can supply an adjacent Sensor-CASSY


with power as long as the total current consumption is less
than 1.6 A (two modules at most, disconnection in the case
of overload).
• Additional modules have to be supplied with power sepa-
rately.

®
CASSY is a registered trademark of LD DIDACTIC GmbH.
Installation instruction 524 013 Page 2/2

4 Activation code
During or after installation, CASSY Lab 2 has to be activated for
use with CASSY. For an interim period (16 runs max.), CASSY
Lab 2 can be used without activation. There are no limitations
for using CASSY Lab 2 in conjunction with other devices (e.g.
electronic balances, IR position detector) without activation.
The name and activation code required for activation are sup-
plied with the delivery note and the invoice for CASSY Lab 2
(524 220). If you do not have the activation code, please fax the
invoice for CASSY Lab 2 (524 220) to
+49-2233-604607.
As a reply you will receive a fax with the activation code as soon
as possible.

5 Licence
Together with the purchase of CASSY Lab 2 (524 220) a school
licence is granted:
• The activated software may only be used by the purchaser
exclusively for teaching purposes at the respective school
or institution! Use for preparation at home is included in this
licence.
• Passing the activation code to other schools or institutions
is prohibited.
LD DIDACTIC GmbH reserves the right to take legal action in
the case of violation of these provisions.

6 Online documentation and manual


Please take the description of the CASSY Lab 2 program as
well as the description of the different CASSY modules from the
CASSY Lab 2 online documentation. There you also find nu-
merous descriptions of experiment examples.
The text of the CASSY Lab 2 manual is identical with the online
documentation. It is available under the catalogue number (524
201) and contained on the CASSY Lab 2 CD-ROM as a PDF
file. From there you can print the manual.

7 Support
If you have still questions after reading the description of the
program or if you would like to make suggestions resulting from
your experience with the software, please send us an e-mail
message to the following address:
[email protected].

8 Updates
The CASSY Lab 2 software and the CASSY operating systems
of Sensor-CASSY 2 and Power-CASSY can be extended. Fu-
ture versions are available free of charge in the internet under
http://www.ld-didactic.com
We recommend you to keep informed on news and visit our
homepage regularly (once a year). The serial protocol of
CASSY and a Delphi component for developing your own pro-
grams are published there, too.

LD DIDACTIC GmbH . Leyboldstrasse 1 . D-50354 Huerth / Germany . Phone (02233) 604-0 . Fax (02233) 604-222 . e-mail: [email protected]

©by LD DIDACTIC GmbH Printed in the Federal Republic of Germany


Technical alterations reserved