General Specifications: Model EJA510A and EJA530A Absolute and Gauge Pressure Transmitters
General Specifications: Model EJA510A and EJA530A Absolute and Gauge Pressure Transmitters
General Specifications: Model EJA510A and EJA530A Absolute and Gauge Pressure Transmitters
STANDARD SPECIFICATIONS
Refer to GS 01C22T02-00E for FOUNDATION Fieldbus
communication type and GS 01C22T03-00E for
PROFIBUS PA communication type marked with “”.
PERFORMANCE SPECIFICATIONS
Zero-based calibrated span, linear output, wetted
parts material code ‘S’ and silicone oil. Power Supply Effects “”
Reference Accuracy of Calibrated Span 0.005 % per Volt (from 21.6 to 32 V DC, 350 )
(including the effects of zero-based linearity, hyster- FUNCTIONAL SPECIFICATIONS
esis, and repeatability, values are in absolute for
EJA510A) Span & Range Limits
0.2 % of Span (Values are in absolute for EJA510A)
Measurement
0.075 % of Span, when/ HAC is specified Span and
(EJA530A: A, B and C capsule) MPa psi (/D1) bar (/D3) kgf/cm2(/D4)
Range
10 to 200 1.45 to 29
0.12 % of Span, when/ HAC is specified Span
kPa
0.1 to 2 0.1 to 2
(EJA530A: D capsule) A
Range 0 to 200 0 to 29 0 to 2 0 to 2
kPa
For spans below X, Span 0.1 to 2 14.5 to 290 1 to 20 1 to 20
X B
[0.050.15 ] % of Span Range 0 to 2 0 to 290 0 to 20 0 to 20
Span
Span 0.5 to 10 72.5 to 1450 5 to 100 5 to 100
C
X
[0.0250.05 ] % of span, when/ HAC is Range 0 to 10 0 to 1450 0 to 100 0 to 100
Span
Span 5 to 50 720 to 7200 50 to 500 50 to 500
specified (EJA530A: A, B and C capsule) D
Range 0 to 50 0 to 7200 0 to 500 0 to 500
T01E.EPS
X
[0.030.09 ] % of span, when/ HAC is URL is defined as the Upper Range Limit from the
Span table above.
specified (EJA530A: D capsule)
Where X equals: Zero Adjustment Limits
Capsule X MPa {psi} Zero can be fully elevated or suppressed, within the
A 20 kPa {2.9} Lower and Upper Range Limits of the capsule.
A with/ HAC 40 kPa {5.8} External Zero Adjustment “”
B 0.2 {29} External zero is continuously adjustable with 0.01 %
C 1 {145} incremental resolution of span. Span may be
D 8 {1160} adjusted locally using the digital indicator with range
Ambient Temperature Effects switch.
Total Effects per 28 C (50 F) Change Mounting Position Effect
[0.15% Span 0.15% URL] Rotation in diaphragm plane has no effect. Tilting up
Stability to 90 will cause zero shift up to 0.27 kPa {1.1 inH2O}
0.1% of URL per 12 months which can be corrected by the zero adjustment.
Vibration Effects Output “”
0.1 % of URL Two wire 4 to 20 mA DC output with digital communi-
(5 to 15Hz; 4mm peak-to-peak constant displace- cations. BRAIN or HART FSK protocol are superim-
ment, 15 to 150Hz; 2g, 150 to 2000Hz; 1g) posed on the 4 to 20 mA signal.
R ()
All Rights Reserved. Copyright © 1999, Yokogawa Electric Corporation GS 01C21F01-00E Mar. 23, 2006-00
<<Contents>> <<Index>> 3
Supply Voltage “” PHYSICAL SPECIFICATIONS
10.5 to 42 V DC for general use and flameproof type
10.5 to 32 V DC for lightning protector (Optional Wetted Parts Materials:
code /A) Diaphragm and Process connector
10.5 to 30 V DC for intrinsically safe, Type n, Refer to ‘MODEL AND SUFFIX CODE.’
nonincendive, or non-sparking type Non-wetted Parts Materials:
Minimum voltage limited at 16.4 V DC for digital
communications, BRAIN and HART Housing
Low copper cast-aluminum alloy with polyurethane
Load (Output signal code D and E)
paint (Munsell 0.6GY3.1/2.0)
0 to 1335 for operation
250 to 600 for digital communication Degrees of Protection
IP67, NEMA4X
EMC Conformity Standards “” ,
Cover O-rings
EN61326-1 Class A, Table2 (For use in industrial Buna-N, fluoro-rubber (optional)
locations)
EN61326-2-3 Data plate and tag
SUS304 or SUS316 (option)
European Pressure Equipment Directive 97/23/EC
Sound Engineering Practice Fill Fluid
Silicone, Fluorinated oil (option)
With option code /PE3 Weight
1.6 kg (3.5 lb) without integral indicator, mounting
bracket.
Category III, Module H, Type of Equipment: Pressure
Accessory-Vessel, Type of Fluid: Liquid and Gas, Connections
Group of Fluid: 1 and 2 Refer to the model code to specify the process and
Safety Requirement Standards the electrical connection type.
EN61010-1
• Altitude of installation site: Max. 2,000 m above sea level < Settings When Shipped > “”
• Installation category: I
Tag Number As specified in order *1
• Pollution degree: 2
Output Mode ‘Linear’
• Indoor/Outdoor use Display Mode ‘Linear’
Communication Requirements “” Operation ‘Normal’ unless otherwise specified in
Mode order
BRAIN
Damping Time ‘2 sec.’
Communication Distance Constant
Up to 2 km (1.25 miles) when using CEV polyethyl- Calibration
ene-insulated PVC-sheathed cables. Communication Range As specified in order
distance varies depending on type of cable used. Lower Range
Value
Load Capacitance Calibration
0.22 F or less (see note) Range As specified in order
Higher Range
Load Inductance Value
3.3 mH or less (see note) Selected from mmH2O, mmAq, mmWG,
Calibration mmHg, Torr, Pa, hPa, kPa, MPa, mbar,
Spacing from power line Range Units bar, gf/cm2, kgf/cm2, inH2O, inHg, ftH2O,
15 cm or more. psi, or atm.(Only one unit can be specified)
T05E.EPS
Input Impedance of communicating device
10 k or more at 2.4 kHz. *1: Up to 16 alphanumeric characters for BRAIN and
8 characters for HART including ‘-’ and ‘.’ will be
entered in the amplifier memory. If specified Tag
Note : For general-use and Flameproof type. includes other characters than above, it will not
For Intrinsically safe type, please refer to be entered in the amplifier memory.
‘OPTIONAL SPECIFICATIONS.’
All Rights Reserved. Copyright © 1999, Yokogawa Electric Corporation GS 01C21F01-00E April 01, 2013-00
<<Contents>> <<Index>> 4
MODEL AND SUFFIX CODES
Model EJA510A and EJA530A
The ‘’ marks indicate the most typical selection for each specification. Example: EJA530A-DAS4N-02NN/
The ‘#’marks indicate the construction materials conform to NACE material recommendations per MR01-75. For the use of
SUS316 material, there may be certain limitations for pressure and temperature. Please refer to NACE standards for details.
All Rights Reserved. Copyright © 1999, Yokogawa Electric Corporation GS 01C21F01-00E Jul. 08, 2009-00
<<Contents>> <<Index>> 5
OPTIONAL SPECIFICATIONS (For Explosion Protected types “”)
For FOUNDATION Fieldbus explosion protected type, see GS 01C22T02-00E.
For PROFIBUS PA explosion protected type, see GS 01C22T03-00E.
*1: Applicable for Electrical connection code 2, 7 and C (1/2 NPT female).
*2: Applicable for Electrical connection code 2, 4, 7, 9, C and D (1/2 NPT and M20 female).
*3: Applicable for Output signal code D and E.
For intrinsically safe approval, use the safety barrier certified by the testing laboratories (BARD-400 is not applicable).
*4: Lower limit of ambient temperature is –15˚C (5˚F) when /HE is specified.
All Rights Reserved. Copyright © 1999, Yokogawa Electric Corporation GS 01C21F01-00E April 01, 2013-00
<<Contents>> <<Index>> 6
Item Description Code
CSA Explosionproof Approval *1 *3 *4
Applicable standard: C22.2 No. 0, No. 0.4, No. 25, No. 30, No. 94, No. 142
Certificate: 1089598
Explosionproof for Class I, Division 1, Groups B, C and D
Dustignitionproof for Class II/III, Division 1, Groups E, F and G
Division2 ‘SEALS NOT REQUIRED’ , Temp. Class: T4, T5, T6 Encl Type 4x CF1
Max. Process Temp.: T4; 120C (248F), T5; 100C (212F), T6; 85C (185F)
Amb. Temp.: –40 to 80C (–40 to 176F)
Process Sealing Certification
Dual Seal Certified by CSA to the requirement of ANSI/ISA 12.27.01
No additional sealing required. Primary seal failure annunciation:
at the zero adjustment screw
Canadian Standards
Association (CSA) CSA Intrinsically safe Approval *1 *3 *4
Applicable standard: C22.2 No. 0, No. 0.4, No. 25, No. 30, No. 94, No. 142, No. 157,
No. 213
Certificate: 1053843
Class I, Groups A, B, C and D Class II and III, Groups E, F and G
Encl Type 4x, Temp. Class: T4, Amb. Temp.: –40 to 60C (–40 to 140F) CS1
Vmax=30 V, Imax=165 mA, Pmax=0.9 W, Ci=22.5 nF, Li=730 H
Process Sealing Certification
Dual Seal Certified by CSA to the requirement of ANSI/ISA 12.27.01
No additional sealing required. Primary seal failure annunciation:
at the zero adjustment screw
Combined CF1 and CS1 *1 *3 *4 CU1
IECEx Intrinsically safe, type n and Flameproof Approval *3 *4 *5
Intrinsically safe and type n
Applicable Standard: IEC 60079-0:2004, IEC 60079-11:1999, IEC 60079-15:2005,
IEC 60079-26:2005
Certificate: IECEx KEM 06.0007X
Ex ia IIC T4, Ex nL IIC T4 Enclosure: IP67
Amb. Temp.: –40 to 60C (–40 to 140F), Max. Process Temp.: 120C (248F)
IECEx Electrical Parameters: [Ex ia] Ui=30 V, Ii=165 mA, Pi=0.9 W, Ci=22.5 nF, Li=730 H
SU2
Scheme [Ex nL] Ui=30 V, Ci=22.5 nF, Li=730 H
Flameproof
Applicable Standard: IEC 60079-0:2004, IEC60079-1:2003
Certificate: IECEx KEM 06.0005
Ex d IIC T6...T4 Enclosure: IP67
Max.Process Temp.: T4;120C (248F), T5;100C (212F), T6; 85C (185F)
Amb.Temp.: –40 to 75C (–40 to 167F) for T4, –40 to 80C (–40 to 176F) for T5,
–40 to 75C (–40 to 167F) for T6
T03-2E.EPS
*1: Applicable for Electrical connection code 2, 7 and C (1/2 NPT female).
*2: Applicable for Electrical connection code 2, 4, 7, 9, C and D (1/2 NPT and M20 female).
*3: Applicable for Output signal code D and E.
For intrinsically safe approval, use the safety barrier certified by the testing laboratories (BARD-400 is not applicable).
*4: Lower limit of ambient temperature is –15˚C (5˚F) when /HE is specified.
*5: Applicable for Electrical connection code 2, 4, 7, C and D (1/2 NPT and M20 female).
All Rights Reserved. Copyright © 1999, Yokogawa Electric Corporation GS 01C21F01-00E July 01, 2011-00
<<Contents>> <<Index>> 7
OPTIONAL SPECIFICATIONS
Item Description Code
High accuracy type *11 High accuracy HAC
Amplifier cover only P
Color change
Painting *12 Amplifier cover and terminal cover, Munsell 7.5 R4/14 PR
Coating change Epoxy resin-baked coating *15 X1
Fluoro-rubber O-ring All O-rings of amplifier housing. Lower limit of ambient temperature: 15C (5F) HE
Transmitter power supply voltage: 10.5 to 32 V DC (10.5 to 30 V DC for intrinsically
Lightning protector safe type, 9 to 32 V DC for Fieldbus communication type.) A
Allowable current: Max. 6000 A (140 s), Repeating 1000 A (140 s) 100 times
Degrease cleansing treatment *15 K1
Oil-prohibited use Degrease cleansing treatment with fluorinated oil filled capsule.
Operating temperature 20 to 80C K2
Wired tag plate Stainless steel tag plate wired onto transmitter N4
PED 97/23/EC
European Pressure
Category: III, Module: H, Type of Equipment: Pressure Accessory-Vessel, PE3
Equipment Directive *14
Type of Fluid: Liquid and Gas, Group of Fluid: 1 and 2
Mill Certificate Process connector M15
Test Pressure: 200 kPa (2 kgf/cm2) *4 T05
Pressure test/Leak test Test Pressure: 2 MPa (20 kgf/cm2) *5 Nitrogen (N2) Gas or Water *8 T06
Certificate *13 Retention time: 10 minutes
Test Pressure: 10 MPa (100 kgf/cm2) *6 T07
Test Pressure: 50 MPa (500 kgf/cm2) *7 T08
T04E.EPS
*1: The unit of MWP (Max. working pressure) on the name plate of a housing is the same unit as specified by Option code
D1, D3 and D4.
*2: Applicable for Output signal code D and E. The hardware error indicates faulty amplifier or capsule.
When combining with Option code F1, output status for down-scale is –2.5%, 3.6 mA DC or less.
*3: Applicable for Electrical connection code 2, 3, 4, A, C and D. Not applicable for Option code P and X1.
*4: Applicable for Capsule code A.
*5: Applicable for Capsule code B.
*6: Applicable for Capsule code C.
*7: Applicable for Capsule code D.
*8: Pure nitrogen gas or pure water is used for oil-prohibited use (Option code K1 and K2)
*9: Applicable for Output signal code D and E. Write protection switch is attached for Output code E.
*10: Not applicable for Option code C1.
*11: Applicable for EJA530A. Refer to GS 01C21F01-02E.
*12: Standard polyurethan painting can be used in acid atmosphere, whereas the epoxy resin-baked coating (Option code
X1) can be used in alkaline atmosphere. Anti-corrosion coating, the combination of polyurethan and epoxy resin-baked
coating, is available by special order as sea water, alkaline, and acid resistant.
*13: The unit on the certificate is always kPa or MPa regardless of selection of option code D1, D3, or D4.
*14: If compliance with category III is needed, specify this option code.
*15: Not applicable for color change option.
*16: Applicable for Output signal code E.
All Rights Reserved. Copyright © 1999, Yokogawa Electric Corporation GS 01C21F01-00E July 01, 2011-00
<<Contents>> <<Index>> 8
DIMENSIONS
Model EJA510A and EJA530A
With Process Connection code 7
Unit: mm(Approx. inch)
Conduit connection 12 45
Ground
(0.47) (1.77) terminal
Shrouding bolt *2
(3.07)
78
127(5.0)
111(4.37)
170(6.69)
LOCK ZERO LOCK
Zero adjustment
Adapter
124(4.88)
Pipe(Open to atmosphere)*1
44(1.73)
(1.85)
47
176(6.92)
6(0.24)
5(0.19)
F03E.EPS
All Rights Reserved. Copyright © 1999, Yokogawa Electric Corporation GS 01C21F01-00E April 01, 2013-00
<<Contents>> <<Index>> 9
SELECTION GUIDE
Measurement Span Maximum Working Pressure
Application Type Model Capsule
kPa inH2O MPa psi
L 0.5 to 10 2 to 40 16*4 2250*4
Differential M 1 to 100 4 to 400 16 2250
Pressure Traditional-Mounting*1 EJA110A
H 5 to 500 20 to 2000 16 2250
V 0.14 to 14MPa 20 to 2000 psi 16 2250
L 1 to 10 4 to 40 3.5 500
Flow Integral Orifice EJA115 M 2 to 100 8 to 400 14 2000
H 20 to 210 80 to 830 14 2000
Differential Pressure Extended EJA118N M 2.5 to 100 10 to 400
& Liquid Level Flush EJA118W 25 to 500 Based on Flange Rating
H 100 to 2000
with Remote Seals Combination EJA118Y
Draft Range Traditional-Mounting*1 EJA120A E 0.1 to 1 0.4 to 4 50 kPa 7.25
Differential Pressure Traditional-Mounting*1 M 1 to 100 4 to 400 32 4500
& Liquid Level EJA130A
H 5 to 500 20 to 2000 32 4500
Liquid Level, Closed Flush EJA210A M 1 to 100 4 to 400
20 to 2000 Based on Flange Rating
or Open Tank Extended EJA220A H 5 to 500
L 0.67 to 10*2 2.67 to 40*2 10 kPa*2 40 in H2O*2
Absolute (vacuum) 130 kPa*2
Pressure Traditional-Mounting*1 EJA310A M 1.3 to 130*2 0.38 to 38 inHg*2 18.65*2
A 0.03 to 3 MPa*2 4.3 to 430 psi*2 3000 kPa*2 430*2
A 0.03 to 3 MPa 4.3 to 430 psi 3 430
Gauge Pressure Traditional-Mounting*1 EJA430A 0.14 to 14 MPa 20 to 2000 psi 14 2000
B
Gauge Pressure Extended EJA438N A 0.06 to 3 MPa 8.6 to 430 psi Based on Flange Rating
with Remote Seal B 0.46 to 7 MPa 66 to 1000 psi
Gauge Pressure A 0.06 to 3 MPa 8.6 to 430 psi
Flush EJA438W 66 to 2000 psi Based on Flange Rating
with Remote Seal B 0.46 to 14 MPa
C 5 to 32 MPa 720 to 4500 psi 32 4500
High Gauge Traditional-Mounting*1 EJA440A 5 to 50 MPa 720 to 7200 psi
D 50 7200
A 10 to 200 1.45 to 29 psi 200 kPa 29
Absolute & Gauge EJA510A B 0.1 to 2 MPa 14.5 to 290 psi 2 290
Direct-Mounting
Pressure*3 EJA530A C 0.5 to 10 MPa 72.5 to 1450 psi 10 1450
D 5 to 50 MPa 720 to 7200 psi 50 7200
T06E.EPS
*1: Traditional-mounting is 1/4 - 18 NPTF process connections ( 1/2 - 14 NPTF with process adapters ) on 2-1/8" centers.
*2: Measurement values in absolute.
*3: Measurement values in absolute for EJA510A.
*4: When combined with Wetted parts material code H, M, T, A, D, and B, the value is 3.5 MPa (500 psi).
All Rights Reserved. Copyright © 1999, Yokogawa Electric Corporation GS 01C21F01-00E Mar. 23, 2006-00
<<Contents>> <<Index>> 10
specifications up to 5 digits (excluding any decimal 6. Other company names and product names used in
point) for low or high range limits within the range of this material are registered trademarks or trademarks
-19999 to 19999. of their respective owners.
6. Tag Number (if required)
< Specification Conformance >
The model EJA510A and EJA530A maintain a
specification conformance to at least 3 .
All Rights Reserved. Copyright © 1999, Yokogawa Electric Corporation GS 01C21F01-00E June 01, 2007-00
Subject to change without notice.