MS-02-188 - Multijacketed Tubing, Single-Jacketed Tubing, and Insulated Tubing
MS-02-188 - Multijacketed Tubing, Single-Jacketed Tubing, and Insulated Tubing
MS-02-188 - Multijacketed Tubing, Single-Jacketed Tubing, and Insulated Tubing
com
Multijacketed Tubing,
Single -Jacketed Tubing,
and Insulated Tubing
Fe ature s
■ 1/4 to 1/2 in. and 6 to 12 mm tubing sizes available in 316/316L stainless steel and copper
■ Thermoplastic polyurethane (TPU) and PVC jackets help protect tubing from external
corrosion and abrasion
■ Fibrous glass insulation reduces heat loss and helps protect personnel
2 Multijacketed Tubing, Jacketed Tubing and Insulated Tubing
Multijacketed Tubing
Swagelok® multijacketed tubing provides protection against galvanic and
atmospheric corrosion and protects the tubing against wear and abrasion. In
addition, it reduces costs by enabling installation of up to four tubes at once.
Features
■ 316/316L stainless steel instrumentation tubing
■ 1/4 to 1/2 in. and 6 to 12 mm tubing sizes
■ Low-temperature, UV-resistant thermoplastic polyurethane Individual tubes are marked
for positive identification
(TPU) for both individual tube jackets and outer jacket along their entire length.
■ Positive identification of individual tubes along entire length
■ Tube and jacket marking standard; see Standard Marking, below.
Dimensions 2 3 4 2 3 4 2 3 4
Dimensions are for reference only Tube Tubes Tubes Tubes H Tubes Tubes Tubes Tubes Tubes Tubes
and are subject to change. OD Wall W, Width Height Weight Max Bulk Length
Dimensions in. lb/ft ft
W
1/4 0.035 1.06 1.41 1.76 0.73 0.37 0.52 0.68 1100 900 725
3/8 0.035 1.31 1.79 2.26 0.86 0.53 0.76 0.99 850 650 500
0.035 1.56 2.16 2.76 0.98 0.69 1.00 1.30 700 500 375
H 1/2
0.049 1.59 2.16 2.76 0.98 0.82 1.18 1.55 600 400 325
Dimensions mm kg/m m
6 1.0 26 35 43 18 0.55 0.78 1.01 395 290 230
10 1.0 34 47 59 22 0.87 1.25 1.63 240 175 135
12 1.0 38 53 67 24 1.03 1.49 1.94 210 150 105
Multijacketed Tubing, Jacketed Tubing and Insulated Tubing 3
Single-Jacketed Tubing
Swagelok single-jacketed tubing helps provide increased protection against
galvanic and atmospheric corrosion. In addition, it helps protect the tubing against
wear and abrasion.
Features
■ 316/316L stainless steel and copper instrumentation tubing
■ 1/4 to 1/2 in. and 6 to 12 mm tubing sizes
■ Low-temperature, UV-resistant PVC jacket standard; optional
thermoplastic polyurethane (TPU) jacket available for higher-temperature service
■ Jacket marking available; see Optional Jacket Marking, below.
Technical Data
Fractional
Min Service
Nominal and Pressure Rating at Min Support Max Bulk Length
Tube Wall Max Process Installation –20 to 100°F Bend Centers Jacket ± 10 %
OD Thickness Temperature Temperature psig Radius ft Weight OD ft
in. in. °F °F Seamless Welded in. Horiz Vert lb/ft in. Seamless Welded
Stainless Steel (ASTM A269, A213➀, TP 316/316L)
1/4 0.035 220, PVC –30, 5100 4080 0.12 0.32 2200 2500
3/8 0.035 jacket; service; 3300 2640 0.19 0.45 1300 2500
8.00 6.00 15.0
0.035➁ 250, TPU –10, 2600 2080 0.25 1000 800
1/2 jacket installation 0.57
0.049 3700 2960 0.31 750 1000
Copper (ASTM B68, B68M, B75, UNS 12200)
1/4 0.030 220, PVC –30, 1400 0.12 0.32 2600
3/8 0.032 jacket; service; 900 0.18 0.45 2000
— 8.00 6.00 15.0 —
0.035➁ 250, TPU –10, 800 0.26
1/2 jacket installation 0.57 1000
0.049 1100 0.33
➀ Nominal wall thickness, not minimum wall thickness.
➁ Not recommended for use with tube fittings in gas service.
Metric
Min Service
Nominal and Pressure Rating at Min Support Max Bulk Length
Tube Wall Max Process Installation –28 to 37°C Bend Centers Jacket ± 10 %
OD Thickness Temperature Temperature bar Radius m Weight OD m
mm mm °C °C Seamless Welded cm Horiz Vert kg/m mm Seamless Welded
Stainless Steel (ASTM A269, A213➀, TP 316/316L)
6 104, PVC –34, 420 336 0.18 7.9 610 305
jacket; service;
10 1.0 240 192 20.3 1.80 4.60 0.32 11.7 335 90
121, TPU –23,
12 jacket installation 200 160 0.38 13.7 275 90
Copper (ASTM B68, B68M, B75, UNS 12200)
6 1.0 104, PVC –34, 94.0 0.18 7.9 915
jacket; service;
10 1.0 60.0 — 20.3 1.80 4.60 0.32 11.7 305 —
121, TPU –23,
12 1.0➁ jacket installation 54.0 0.38 13.7 305
➀ Nominal wall thickness, not minimum wall thickness. Seamless metric sizes also meet DIN 17458 test 1 class material 1.4401/1.4404.
➁ Not recommended for use with tube fittings in gas service.
Insulated Tubing
Swagelok insulated tubing is designed for use in applications such as steam supply,
condensate return, and gas and liquid transport lines, where weatherproofing and energy
conservation are important. Swagelok insulated tubing helps protect personnel from
hot process and steam lines, reduces heat loss, and offers a cost-effective
alternative to field-installed insulation of small-diameter tubing systems.
Features
■ 316/316L stainless steel and copper instrumentation tubing
■ 1/4 to 1/2 in. and 6 to 12 mm tubing sizes
■ Low-temperature, UV-resistant PVC jacket standard; optional TPU jacket available
■ Absorption-resistant fibrous glass insulation
■ Insulation contains less than 100 ppm of water-soluble chlorides
Seal insulation ends to prevent
■ Jacket marking standard; see Standard Jacket Marking, below. contamination of the insulation.
Technical Data
Fractional
Min Service
Nominal and Pressure Rating at Min Support Max Bulk Length
Tube Wall Max Process Installation 400°F Bend Centers Jacket ± 10 %
OD Thickness Temperature Temperature psig Radius ft Weight OD ft
in. in. °F °F Seamless Welded in. Horiz Vert lb/ft in. Seamless Welded
Stainless Steel (ASTM A269, A213➀, TP 316/316L)
1/4 0.035 –30, 4896 3916 0.20 1.00 1100
1250
3/8 0.035 service; 3168 2534 0.30 1.13 1300
400➂ 8.00 6.00 15.0
0.035➁ –10, 2496 1996 1000 800
1/2 installation 0.45 1.25
0.049 3552 2841 750 1000
Copper (ASTM B68, B68M, B75, UNS 12200)
1/4 0.030 –30, 700 0.26 1.00 1300
3/8 0.032 service; 450 0.34 1.13 1000
400➂ — 8.00 6.00 15.0 —
0.035➁ –10, 400 0.43
1/2 installation 1.25 1000
0.049 550 0.50
➀ Nominal wall thickness, not minimum wall thickness.
➁ Not recommended for use with tube fittings in gas service.
➂ The maximum jacket surface temperature is 140°F with a process temperature of 400°F, an ambient temperature of 80°F, and a wind of 10 mph.
Metric
Min Service
Pressure Rating at Support Max Bulk Length
Nominal and Min
204°C Centers ± 10 %
Tube Wall Max Process Installation Bend Jacket
bar m m
OD Thickness Temperature Temperature Radius Weight OD
mm mm °C °C Seamless Welded cm Horiz Vert kg/m mm Seamless Welded
Stainless Steel (ASTM A269, A213➀, TP 316/316L)
6 –34, 403 322 0.40 24.9 610 305
service;
10 1.0 204➁ 230 184 20.3 1.80 4.60 0.57 28.7 335 90
–23,
12 installation 192 153 0.63 30.7 275 90
Copper (ASTM B68, B68M, B75, UNS 12200)
6 1.0 –34, 47.0 0.40 24.9 455
service;
10 1.0 204➁ 30.0 — 20.3 1.80 4.60 0.55 28.7 305 —
–23,
12 1.0➂ installation 27.0 0.64 30.7 305
➀ Nominal wall thickness, not minimum wall thickness. Seamless metric sizes also meet DIN 17458 test 1 class material 1.4401/1.4404.
➁ The maximum jacket surface temperature is 60°C with a process temperature of 204°C, an ambient temperature of 26°C, and a wind of 16 km/h.
➂ Not recommended for use with tube fittings in gas service.
Insulated Tubing
Heat Loss
The information presented represents typical performance data for low-temperature PVC and TPU jackets
for the conditions given. Actual results may vary with the conditions of installation. Heat loss calculated
with 25 mph (40 km/h) wind.
50 40 50 40
40 40
30 30
30 30
20 20
20 20
10 10 10 10
0 0 0 0
–60 –40 –20 0 20 40 60 80 100 120 –60 –40 –20 0 20 40 60 80 100 120
Ambient Temperature, °F Ambient Temperature, °F
70
JAPAN
50 40
USA
60 50
40 30
50 40
30 20
40
30
20 10
30
10 20
20 0
–50 –40 –30 –20 –10 0 10 20 30 40
0
10 10
–50 –40 –30 –20 –10 0 10 20 30 40
0 0
–60 –40 –20 0 20 40 60 80 100 120
Ambient Temperature, °F
Jacket Properties
90
Jacket Properties Low-Temperature PVC Thermoplastic Polyurethane (TPU)
80
Tensile strength 2200 psi (151 bar) 3800 psi (261 bar)
70
Elongation 350 % 700 %
60 Hardness, Shore A 80 80
JAPAN
50 Maximum temperature 220°F (104°C) 250°F (121°C)
Minimum
40 installation temperature –10°F (–23°C) –40°F (–40°C)
Minimum
30 service temperature –30°F (–34°C) –67°F (–55°C)
20
Halogenated (chlorides) Yes No
Water absorption 0.10 % 1.2 to 1.4 %
10
24 rating in accordance with V2 in accordance with
0 Flame resistance
ASTM D2863 UL94
–50 –40 –30 –20 –10 0 10 20 30 40
750 h in accordance with 2000 h in accordance with
UV resistance
UL-1581 QUV aging test
6 Multijacketed Tubing, Jacketed Tubing and Insulated Tubing
Ordering Information
Multijacketed Tubing
Build a multijacketed tubing ordering number by combining the designators in the sequence shown below.
A B C D E F
S S - M J T 2 - 4 -S-0 3 5 - F 1
A Material D Size: Tube OD and Wall Thickness E Package Length Unit of Measure
SS = 316/316L stainless steel Seamless Stainless Steel, Fractional F = Feet
4-S-035 = 1/4 0.035 in. M = Meters
B Model 6-S-035 = 3/8 0.035 in.
MJT = Multijacketed 8-S-035 = 1/2 0.035 in. F Package Length, Tolerance
8-S-049 = 1/2 0.049 in. Specify a bulk length up to the
C Number of Tubes Seamless Stainless Steel, Metric maximum bulk length shown on
2 = 2 tubes of same size 6M-S-1.0M = 6 1.0 mm page 2.
3 = 3 tubes of same size 10M-S-1.0M = 10 1.0 mm 1 =Continuous length, ± 5 %
4 = 4 tubes of same size 12M-S-1.0M = 12 1.0 mm (contains one piece)
Welded Stainless Steel, Fractional 2 =Exact length, ± 0.5 % (may
4-W-035 = 1/4 0.035 in. contain multiple pieces)
6-W-035 = 3/8 0.035 in. 3 =Continuous, exact length, ± 0.5 %
8-W-035 = 1/2 0.035 in. (contains one piece)
8-W-049 = 1/2 0.049 in. 4 =Standard length, ± 5 % (may
Welded Stainless Steel, Metric contain multiple pieces)
6M-W-1.0M = 6 1.0 mm
10M-W-1.0M = 10 1.0 mm
12M-W-1.0M = 12 1.0 mm
A B C D E
S S - S T 4 -S-0 3 5 - 1 0 0 - U
A Material C Size: Tube OD and Wall Thickness D Package Length
CU = Copper Copper, Fractional Fractional
SS = 316/316L stainless steel 4-030 = 1/4 0.030 in. 100 = 100 ft (30.5 m)
6-032 = 3/8 0.032 in. 250 = 250 ft (76.2 m)
B Model 8-035 = 1/2 0.035 in. 500 = 500 ft (152 m)
JT = Single-jacketed 8-049 = 1/2 0.049 in. xxxx = Bulk length➀
ST = Insulated Copper, Metric Metric
6M-1.0M = 6 1.0 mm 30M = 30 m (98.4 ft)
10M-1.0M = 10 1.0 mm 75M = 75 m (246 ft)
12M-1.0M = 12 1.0 mm 150M = 150 m (492 ft)
12M-1.5M = 12 1.5 mm xxxx = Bulk length➀
Seamless Stainless Steel, Fractional ➀ See pages 3 and 4 for the maximum bulk
length of tubing.
4-S-035 = 1/4 0.035 in.
6-S-035 = 3/8 0.035 in.
8-S-035 = 1/2 0.035 in.
E Options
Seamless Stainless Steel, Metric
6M-S-1.0M = 6 1.0 mm For multiple options, add designators in
10M-S-1.0M = 10 1.0 mm alphabetical order.
12M-S-1.0M = 12 1.0 mm M =Jacket marking, 6 ft (2 m)
Welded Stainless Steel, Fractional intervals (model JT only; see
4-W-035 = 1/4 0.035 in. page 3 for details)
6-W-035 = 3/8 0.035 in. U =TPU jacket
8-W-035 = 1/2 0.035 in.
Welded Stainless Steel, Metric
6M-W-1.0M = 6 1.0 mm
10M-W-1.0M = 10 1.0 mm
12M-W-1.0M = 12 1.0 mm
Multijacketed Tubing, Jacketed Tubing and Insulated Tubing 7
Options
Jacket Colors Tubing Material and Size
The standard jacket is black. For other colors, contact your Other materials and sizes are available. Contact your
authorized Swagelok sales and service representative. authorized Swagelok representative.
Accessories
Heat-Shrink Adhesive-Lined Sleeves Jacket Patch Kit
Used to protect bare tubing and straight fitting connections The jacket patch kit can be
to jacketed and insulated tubing, these sleeves contain a used to seal a splice in tubing
heat-activated adhesive to provide a watertight seal to the or to repair any incidental field
protected area. damage to insulation and jacket.
Each kit contains thermal
Sleeve Description Ordering Number insulation, fiberglass tape, and
0.75 in. (19.0 mm) dia, shrinks to 10 self-sealing patches.
MS-HSB-S075
0.20 in. (5.1 mm) dia
Ordering number: MS-JP-KIT
1.00 in. (25.4 mm) dia, shrinks to
MS-HSB-S100
0.30 in. (7.6 mm) dia
2.00 in. (50.8 mm) dia, shrinks to
Weatherproof Strip Insulation
MS-HSB-S200
0.75 in. (19.0 mm) dia Weatherproof strip insulation provides an effective method of
3.00 in. (76.2 mm) dia, shrinks to temporarily insulating components.
MS-HSB-S300
1.00 in. (25.4 mm) dia The jacketed insulation is universal and easy to install. It is
approximately 4 in. (102 mm) wide and 1/2 in. (12.7 mm) thick
Multijacketed Tubing Heat-Shrink Sleeve Selection and is available in standard lengths of 10, 30, and 50 ft (3.0,
9.1, and 15.2 m) packages.
2 Tubes 3 Tubes 4 Tubes
Tube
OD Heat Shrink Boot Ordering Number
Insulation Item Ordering Number
1/4 in. MS-HSB-S100 MS-HSB-S200 MS-HSB-S200 10 ft (3.0 m) insulation strip MS-SI-10
3/8 in. MS-HSB-S200 MS-HSB-S200 MS-HSB-S300
30 ft (9.1 m) insulation strip MS-SI-30
1/2 in. MS-HSB-S300 MS-HSB-S300 MS-HSB-S300
50 ft (15.2 m) insulation strip MS-SI-50
6 mm MS-HSB-S100 MS-HSB-S200 MS-HSB-S200
25 insulation tie straps MS-SITS-KIT
8 mm MS-HSB-S200 MS-HSB-S200 MS-HSB-S200
10 mm MS-HSB-S200 MS-HSB-S200 MS-HSB-S300
Heat-Shrink End-Seal Boots (Insulated Tubing)
12 mm MS-HSB-S300 MS-HSB-S300 MS-HSB-S300
Made of thermally stabilized,
modified polyolefin, these
Silicone Sealing Tape heat-shrinkable boots
Silicone sealing tape is used in conjunction with heat-shrink provide a weatherproof
sleeves to seal the ends of jacketed and insulated tubing end seal for all sizes of insulated tubing and protect against
where the jacket material needs to be removed to assemble moisture ingress.
a fitting. Each kit contains 20 end-seal boots.
Each roll is 10 ft (3.0 m) long and 1.5 in. (38.1 mm) wide. Ordering number: MS-HSB-KIT
Ordering number: MS-SR-B10
Caps (Insulated Tubing)
Silicone Sealant Protective end caps
temporarily seal insulated Tube OD
This silicone RTV sealant is used in conjunction with heat- Ordering
shrink sleeves to seal ends of jacketed and insulated tubing tubing ends and insulatation in. mm Number
from moisture, and it offers excellent resistance to weather, during storage and 1/4
6 MS-46-CAP-KIT
oil, and many chemicals. installation. 3/8
One tube will seal approximately 10 ends; each kit contains Each kit contains 20 caps. 10
1/2 MS-8-CAP-KIT
8 tubes. 12
Service Temperature: –60 to 400°F (–51 to 204°C)
Cure Time: approximately 24 h at 77°F (25°C) and 50 %
relative humidity
Ordering number: MS-RTV-SEAL-KIT
Accessories Tools
Mounting Clips Breakout and Bending Tools
Stainless steel mounting clips The tube breakout bender is used with
secure jacketed tubing to multijacketed tubing to separate and
brackets or tubing trays. Clips bend individual tubes up to 1/2 in. or
consist of a 6 mm bolt and nut 12 mm outside diameter. Tube Breakout
and two 6 mm washers. Bender
The bending tools are used to bend
When using strut-type mounting brackets, also order strut 2-, 3-, or 4-tube multijacketed tubing or insulated tubing
nuts, below. bundles with up to 1/2 in. or 12 mm outside diameter tubes.
Five-Roll Straightener
The straightener can be
mounted to the spool stand for
use with single, coiled jacketed
or nonjacketed tubing up to 1/2
in. or 12 mm outside diameter.
Case included.
Case dimensions: 15.5 H by 19.8 W by 7.25 D in.
(40 H by 50.2 W by 18.4 D cm)
Ordering number: MS‑TST12