Product data sheet 6ES7315-2AH14-0AB0

SIMATIC S7-300,
CPU 315-2DP CPU WITH MPI INTERFACE INTEGRATED
24 V DC POWER SUPPLY 256 KBYTE WORKING
MEMORY 2. INTERFACE DP-MASTER/SLAVE MICRO
MEMORY CARD NECESSARY

General information
Hardware product version 01

Firmware version V3.3

Engineering with
Programming package STEP 7 V5.5 + SP1 or higher or STEP7 V5.2 + SP1 or higher with
HSP 218

Supply voltage
24 V DC Yes

permissible range, lower limit (DC) 19.2 V

permissible range, upper limit (DC) 28.8 V

External protection for supply cables (recommendation) 2 A min.

Mains buffering
Repeat rate, min. 1s

Input current
Current consumption (rated value) 850 mA

Current consumption (in no-load operation), typ. 150 mA

Inrush current, typ. 3.5 A

I²t 1 A²·s

Power losses

6ES7315-2AH14-0AB0 subject to modifications


Page 1/ 10 01/17/2015 © Copyright Siemens AG 2015
Power loss, typ. 4.5 W

Memory
Type of memory other

Work memory
Integrated 256 kbyte

expandable No

Size of retentive memory for retentive data blocks 128 kbyte

Load memory
pluggable (MMC) Yes

pluggable (MMC), max. 8 Mbyte

Data management on MMC (after last programming), min. 10 a

Backup
present Yes ; Guaranteed by MMC (maintenance-free)

without battery Yes ; Program and data

CPU processing times


for bit operations, typ. 0.05 µs

for word operations, typ. 0.09 µs

for fixed point arithmetic, typ. 0.12 µs

for floating point arithmetic, typ. 0.45 µs

CPU-blocks
Number of blocks (total) 1024 ; (DBs, FCs, FBs); the maximum number of loadable blocks
can be reduced by the MMC used.

DB
Number, max. 1024 ; Number range: 1 to 16000

Size, max. 64 kbyte

FB
Number, max. 1024 ; Number range: 0 to 7999

Size, max. 64 kbyte

FC
Number, max. 1024 ; Number range: 0 to 7999

Size, max. 64 kbyte

OB
Description see instruction list

Size, max. 64 kbyte

Number of free cycle OBs 1 ; OB 1

Number of time alarm OBs 1 ; OB 10

Number of delay alarm OBs 2 ; OB 20, 21

Number of time interrupt OBs 4 ; OB 32, 33, 34, 35

Number of process alarm OBs 1 ; OB 40

6ES7315-2AH14-0AB0 subject to modifications


Page 2/ 10 01/17/2015 © Copyright Siemens AG 2015
Number of DPV1 alarm OBs 3 ; OB 55, 56, 57

Number isochronous mode OBs 1 ; OB 61

Number of startup OBs 1 ; OB 100

Number of asynchronous error OBs 5 ; OB 80, 82, 85, 86, 87

Number of synchronous error OBs 2 ; OB 121, 122

Nesting depth
per priority class 16

additional within an error OB 4

Counters, timers and their retentivity

S7 counter
Number 256

Retentivity
can be set Yes

lower limit 0

upper limit 255

preset Z 0 to Z 7

Counting range
lower limit 0

upper limit 999

IEC counter
present Yes

Type SFB

Number Unlimited (limited only by RAM capacity)

S7 times
Number 256

Retentivity
can be set Yes

lower limit 0

upper limit 255

preset No retentivity

Time range
lower limit 10 ms

upper limit 9990 s

IEC timer
present Yes

Type SFB

Number Unlimited (limited only by RAM capacity)

Data areas and their retentivity

6ES7315-2AH14-0AB0 subject to modifications


Page 3/ 10 01/17/2015 © Copyright Siemens AG 2015
retentive data area, total All, 128 KB max.

Flag
Number, max. 2048 byte

Retentivity available Yes ; MB 0 to MB 2047

Retentivity preset MB 0 to MB 15

Number of clock memories 8 ; 1 memory byte

Data blocks
Number, max. 1024 ; Number range: 1 to 16000

Size, max. 64 kbyte

Retentivity adjustable Yes ; via non-retain property on DB

Retentivity preset Yes

Local data
per priority class, max. 32 kbyte ; Max. 2 KB per block

Address area

I/O address area


Inputs 2048 byte

Outputs 2048 byte

of which, distributed
Inputs 2048 byte

Outputs 2048 byte

Process image
Inputs 2048 byte

Outputs 2048 byte

Inputs, adjustable 2048 byte

Outputs, adjustable 2048 byte

Inputs, default 128 byte

Outputs, default 128 byte

Subprocess images
Number of subprocess images, max. 1

Digital channels
Inputs 16384

Outputs 16384

Inputs, of which central 1024

Outputs, of which central 1024

Analog channels
Inputs 1024

Outputs 1024

Inputs, of which central 256

6ES7315-2AH14-0AB0 subject to modifications


Page 4/ 10 01/17/2015 © Copyright Siemens AG 2015
Outputs, of which central 256

Hardware configuration
Expansion devices, max. 3

Number of DP masters
Integrated 1

Via CP 4

Number of operable FMs and CPs (recommended)


FM 8

CP, point-to-point 8

CP, LAN 10

Rack
Racks, max. 4

Modules per rack, max. 8

Time of day

Clock
Hardware clock (real-time clock) Yes

battery-backed and synchronizable Yes

Deviation per day, max. 10 s ; Typ.: 2 s

Backup time 6 wk ; At 40 °C ambient temperature

Behavior of the clock following POWER-ON Clock continues running after POWER OFF

Behavior of the clock following expiry of backup period Clock continues to run with the time at which the power failure
occurred

Operating hours counter


Number 1

Number/Number range 0

Range of values 0 to 2^31 hours (when using SFC 101)

Granularity 1 hour

retentive Yes ; Must be restarted at each restart

Clock synchronization
supported Yes

to MPI, master Yes

to MPI, slave Yes

to DP, master Yes ; With DP slave only slave clock

to DP, slave Yes

in AS, master Yes

in AS, slave No

Digital inputs
Number of digital inputs 0

Digital outputs

6ES7315-2AH14-0AB0 subject to modifications


Page 5/ 10 01/17/2015 © Copyright Siemens AG 2015
Number of digital outputs 0

Analog inputs
Number of analog inputs 0

Analog outputs
Number of analog outputs 0

Interfaces
Number of USB interfaces 0

Number of parallel interfaces 0

Number of 20 mA interfaces (TTY) 0

Number of RS 232 interfaces 0

Number of RS 422 interfaces 0

Number of other interfaces 0

1. Interface
Interface type Integrated RS 485 interface

Physics RS 485

Isolated No

Power supply to interface (15 to 30 V DC), max. 200 mA

Functionality
MPI Yes

DP master No

DP slave No

Point-to-point connection No

MPI
Transmission rate, max. 187.5 kbit/s

Services
PG/OP communication Yes

Routing Yes

Global data communication Yes

S7 basic communication Yes

S7 communication Yes ; Only server, configured on one side

S7 communication, as client No

S7 communication, as server Yes

2. Interface
Interface type Integrated RS 485 interface

Physics RS 485

Isolated Yes

Power supply to interface (15 to 30 V DC), max. 200 mA

Functionality

6ES7315-2AH14-0AB0 subject to modifications


Page 6/ 10 01/17/2015 © Copyright Siemens AG 2015
MPI No

DP master Yes

DP slave Yes

Point-to-point connection No

DP master
Transmission rate, max. 12 Mbit/s

Number of DP slaves, max. 124 ; Per station

Services
PG/OP communication Yes

Routing Yes

Global data communication No

S7 basic communication Yes ; I blocks only

S7 communication Yes ; Only server, configured on one side

S7 communication, as client No

S7 communication, as server Yes

Equidistance mode support Yes

Isochronous mode Yes ; OB 61

SYNC/FREEZE Yes

Activation/deactivation of DP slaves Yes

Number of DP slaves that can be simultaneously 8


activated/deactivated, max.

DPV1 Yes

Address area
Inputs, max. 2048 byte

Outputs, max. 2048 byte

User data per DP slave


Inputs, max. 244 byte

Outputs, max. 244 byte

DP slave
GSD file The latest GSD file is available at: http://www.siemens.com/profibus-
gsd

Transmission rate, max. 12 Mbit/s

Automatic baud rate search Yes ; only with passive interface

Address area, max. 32

User data per address area, max. 32 byte

Services
PG/OP communication Yes

Routing Yes ; Only with active interface

Global data communication No

6ES7315-2AH14-0AB0 subject to modifications


Page 7/ 10 01/17/2015 © Copyright Siemens AG 2015
S7 basic communication No

S7 communication Yes ; Only server, configured on one side

S7 communication, as client No

S7 communication, as server Yes

Direct data exchange (slave-to-slave communication) Yes

DPV1 No

Transfer memory
Inputs 244 byte

Outputs 244 byte

Isochronous mode
Isochronous operation (application synchronized up to Yes
terminal)

Communication functions
PG/OP communication Yes

Data record routing Yes

Global data communication


supported Yes

Number of GD loops, max. 8

Number of GD packets, max. 8

Number of GD packets, transmitter, max. 8

Number of GD packets, receiver, max. 8

Size of GD packets, max. 22 byte

Size of GD packet (of which consistent), max. 22 byte

S7 basic communication
supported Yes

User data per job, max. 76 byte

User data per job (of which consistent), max. 76 byte ; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT
or X_GET as server)

S7 communication
supported Yes

as server Yes

As client Yes ; Via CP and loadable FB

User data per job, max. 180 byte ; With PUT/GET

User data per job (of which consistent), max. 240 byte ; as server

S5-compatible communication
supported Yes ; via CP and loadable FC

Number of connections
overall 16

usable for PG communication 15

6ES7315-2AH14-0AB0 subject to modifications


Page 8/ 10 01/17/2015 © Copyright Siemens AG 2015
reserved for PG communication 1

Adjustable for PG communication, min. 1

Adjustable for PG communication, max. 15

usable for OP communication 15

reserved for OP communication 1

adjustable for OP communication, min. 1

adjustable for OP communication, max. 15

usable for S7 basic communication 12

Reserved for S7 basic communication 0

adjustable for S7 basic communication, min. 0

adjustable for S7 basic communication, max. 12

S7 message functions
Number of login stations for message functions, max. 16 ; Depending on the configured connections for PG/OP and S7
basic communication

Process diagnostic messages Yes

simultaneously active Alarm-S blocks, max. 300

Test commissioning functions


Status block Yes ; Up to 2 simultaneously

Single step Yes

Number of breakpoints 4

Status/control
Status/control variable Yes

Variables Inputs, outputs, memory bits, DB, times, counters

Number of variables, max. 30

of which status variables, max. 30

of which control variables, max. 14

Forcing
Forcing Yes

Force, variables Inputs, outputs

Number of variables, max. 10

Diagnostic buffer
present Yes

Number of entries, max. 500

can be set No

Of which powerfail-proof 100 ; Only the last 100 entries are retained

Number of entries readable in RUN, max.

can be set Yes ; From 10 to 499

preset 10

Service data

6ES7315-2AH14-0AB0 subject to modifications


Page 9/ 10 01/17/2015 © Copyright Siemens AG 2015
Can be read out Yes

Ambient conditions

Ambient temperature in operation


max. 60 °C

Configuration

Configuration software
STEP 7 Yes ; V5.2 SP1 or higher with HW update

programming
Command set see instruction list

Nesting levels 8

System functions (SFC) see instruction list

System function blocks (SFB) see instruction list

Programming language
LAD Yes

FBD Yes

STL Yes

SCL Yes

CFC Yes

GRAPH Yes

HiGraph® Yes

Know-how protection
User program protection/password protection Yes

Block encryption Yes ; With S7 block Privacy

Dimensions
Width 40 mm

Height 125 mm

Depth 130 mm

Weights
Weight, approx. 290 g

Status Jan 17, 2015

6ES7315-2AH14-0AB0 subject to modifications