E M II: Synchronous Motor
E M II: Synchronous Motor
Synchronous Motor
Prepared By:
Er. Prabin Gautam
Jestha, 2078
SYNCHRONOUS MOTOR
If a three phase supply is given to the stator of a three phase machine, it
can work as a motor.
As it is driven at synchronous speed, it is called synchronous generator.
So if machine is run as a motor, it will rotate at a synchronous speed.
Such a device which converts an electrical energy into a mechanical
energy running at synchronous speed is called synchronous motor.
8
STARTING METHOD OF SYNCHRONOUS MOTOR
iii. A small induction motor of at least one pair less than the synchronous motor
In 1st method is the unexcited rotor is rotated by means of a dc motor
coupled to the shaft of synchronous motor. As the speed reach near to
synchronous speed, the field winding of synchronous motor is excited
by the dc current and dc motor is switched off. Then the motor
10
Motor Starting with Damper Windings
Damper Windings is the most widely used method to start a synchronous
motor. A Damper Winding consists of heavy copper bars inserted in the slots of
the pole faces of the rotor as shown in the figure below.
These copper bars are short-circuited by end
rings at both ends of the rotor. Thus, these
Figure (ii) is the condition when motor is on No load but has losses
Here vector Eb fall back ( vector rotate clockwise by certain small angle α
So that a resultant voltage ER and hence current Ia is brought into existence
→ which supplies losses
Figure (iii) shows the loaded condition, with loading the rotor will fall back in phase by a
greater value of angle α → called load angle or coupling angle
o Resultant emf ER increased & motor draws an increased armature current, though at a
slightly decreased power factor. 14