Digital Platform Scale Operation Manual
Digital Platform Scale Operation Manual
Digital Platform Scale Operation Manual
lb
x 0.5
400lb x 0.2 kg
city 181 k
g
Capa
O
ECT
DET TARE
ON
OFF
HOLD
lb/kg
00 DR 4
00
8528-M281-O1 DR400C 1
Introduction Before You Begin
Congratulations on your purchase of the 1. Remove scale from its box along with
Model DR400C Digital Platform Scale. Your control panel and the 120V Adapter.
scale is an example of superior design and 2. If using the 120V Adapter, plug one end
craftsmanship. In order to optimize its
into the receptacle (connector) at the
function, be sure to read this instruction
rear of the scale. Insert the other end
manual carefully before use. Keep (the adapter) into a 120V outlet.
instructions handy for future reference.
Battery Installation
Description of Parts
The Digital Platform Scale operates with (6)
Model DR400C “AA” batteries (Alkaline preferred).
Platform
Coiled Cord
lb
x 0.5
400lb x 0.2 kg
Capa
city 181 kg
TO
DET
EC
lb/kg
TARE
HOLD
ON
OFF
OFF
00 DR 40
0
Button
LCD ON
Display Button
2 8528-M281-O1 DR400C
Mounting the Unit General Operation
1. Mount bracket to wall using (2) screws POWER ON
that are appropriate anchors for the To turn the scale on, press the button
surface being mounted to. marked “ON”. The display will first show
“ ” for approximately two (2) seconds,
2. Lower control panel into mounted then display “ ”. This indicates that the
bracket. Insert flat tip screws (included) scale is ready for use.
through round holes in mounting bracket
and drive the screws into existing
threaded holes in lower half of control WEIGHING
panel to secure control panel to bracket. When the display shows “ ” it is ready to
weigh an object. If the object exceeds the
capacity of the scale by more than 5%, the
display will show “oooo”.
TARE OPERATION
To tare (zero out) a load on the platform (i.e.:
the weight of a container), press the button
marked “TARE/HOLD” one time. When this
is done, the display will show the value “ ”.
This could be followed by the addition of
another load, if so desired. The display will
YOUR SCALE IS NOW READY FOR USE. show the sum of all additional loads above
and beyond the tared load.
TARE CAPABILITY
Display and Function A load of up to the capacity of the scale can
be tared (zeroed out).
8528-M281-O1 DR400C 3
Error and Status Messages
Low Battery
If battery is discharged, the display will show
the”bAtt“ message. The operator should
replace the batteries or use the adapter.
Over Load
If the total load exceeds the maximum
capacity of scale, the display will show the
“oooo“ message. The weight must be
removed from the platform and not allowed
to remain on the platform.
Minus weight
If the weight value is less than –99.9 lbs, the
display will show the following: “----“. To
adjust the minus weight, press the
“Tare/Hold” button.
EPROM Failure
If the ”ErrE“ message appears, the operator
should contact their scale service
representative.
4 8528-M281-O1 DR400C
8528-M281-O1 DR400C 5
2