Technological Institute of The Philippines - Manila: Signature
Technological Institute of The Philippines - Manila: Signature
PLATE # 4
Plastic Moment Analysis
RATING
SUBMITTED BY:
1810587 PLATOON N. BEJER SIGNATURE
CE32S2
SUBMITTED TO:
ENGR. JOEVANNIE EMMANUEL C. LUMAGAS
JUNE 1, 2021
PROBLEM 1
a. Use LRFD.
b. Use ASD
SOLUTION:
Properties of W21x48
PROBLEM 2
The beam shown in Figure P5.5-1 is a W14 × 61 of A992 steel and has
continuous lateral support. The load P is a service live load. What is the
maximum permissible value of P?
15’ 15’
FIGURE P5.5-1
a. Use LRFD
b. Use ASD
SOLUTION:
Properties of W14x61
100 mm
10 mm
466.09 mm
bf 9.99 h 10.875
λ= = =7.4 λ= = =29
2tf 2( 0.675) tw 0.375
E 29,000 E 29,000
λ p=0.38
√ Fy
=0.38
√ 50
=9.152 λ p=3.76
√ Fy
=3.76
√ 50
=90.553
50
SOLUTION:
Properties of W14x61
PROBLEM 4
A T-section having a cross section shown has a span of 3.6 m. The location
200mm
40mm
160mm
3.6m
SOLUTION:
PROBLEM 4
7’’
b. Compute the available strength for KxL = KyL = 30 feet. Using LRFD and ASD
design.
SOLUTION:
kL kL
=30 ft ¿ ¿ =30 ft ¿ ¿
r r
Determine the critical net area of the ½ in thick plate shown in the figure
BEJER, PLATOON N.
B SOLVING FOR An
C 1 3 1
An= ( ( ))
2
11−2 +
4 8
An=4.625 i n2
D
CONSIDERING FAILURE ABEF
B SOLVING FOR An
1 3 1 32
( ( )
An= 11−2 + +
2 4 8 4 (6) )
E An=4.813 i n2
B SOLVING FOR An
S2t
An= Ag− A hole +
4g
C
1 3 1 32
An=
2( ( )
11−3 + +
4 8 4 (3) )
E
An=4.563 i n2
F
PROBLEM 5
Determine the critical net area of the ½ in thick plate shown in the figure
BEJER, PLATOON N. 1 ½ ‘’
2 ½ ‘’
1 ½ ‘’
1 ½ ‘’ 3’’ 3’’ 1 ½ ‘’
BEJER, PLATOON N.