GEPON OLT Web User Manual

This document provides a user manual for the WEB configuration of a 4/8 PON OLT. It describes the manual conventions, configuration and preparation required, and then outlines the different sections of the WEB configuration including basic information, PON port management, layer 2 interfaces, layer 2 forwarding, VLANs, port convergence, MSTP, EAPS, layer 3 interfaces, layer 3 forwarding, SNMP, and system management.

Uploaded by

Agam firdauz
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
126 views69 pages

GEPON OLT Web User Manual

This document provides a user manual for the WEB configuration of a 4/8 PON OLT. It describes the manual conventions, configuration and preparation required, and then outlines the different sections of the WEB configuration including basic information, PON port management, layer 2 interfaces, layer 2 forwarding, VLANs, port convergence, MSTP, EAPS, layer 3 interfaces, layer 3 forwarding, SNMP, and system management.

Uploaded by

Agam firdauz
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 69

Shenzhen Baitong Putian Technology Co.

, LTD

GEPON 4/8 PON OLT


Web user manual
Version R1.0
Shenzhen Baitong Putian Technology Co., LTD

Contents
1 About the user manual............................................................................................................ 4

1.1Manual conventions........................................................................ 错误!未定义书签。

2 Configuration and preparation................................................................................................ 5

2.1 configue computerIP........................................................................................................ 5

2.2 Check the network between computer and OLT ......................... 错误!未定义书签。

2.3 Login EPON OLT................................................................................................................ 8

3 WEB configuration................................................................................................................... 9

3.1 Basic information.......................................................................... 错误!未定义书签。

3.2 systerm information....................................................................................................... 10

3.3 PON ports inforamtion................................................................................................... 11

3.3.1 PON ports management and confirgration............................................................. 11

3.3.2 ONU management and confirgration...................................................................... 11

3.4 Layer 2 interface............................................................................................................. 12

3.4.1 ports management.................................................................................................. 12

3.4.2 ports isolation ........................................................................................................ 14

3.4.3 Broadcast storm restriction.....................................................................................16

3.4.4 ports mirror............................................................................................................. 18

3.5 Layer two forwarding......................................................................................................20

3.5.1 forwarding table...................................................................................................... 20

3.5.2 static MAC and filtration..........................................................................................22

3.5.3 MAC binding .......................................................................................................... 24

3.5.4 MAC automatic bindling ........................................................................................ 26

3.5.5 MAC restriction........................................................................................................28

3.6 VLAN............................................................................................ 错误!未定义书签。

3.6.1 VLAN configruation............................................................错误!未定义书签。

3.6.2 Port VLAN...........................................................................错误!未定义书签。

3.6.3 Subnet VLAN...................................................................... 错误!未定义书签。

3.6.4 MAC-Based VLAN...............................................................................................34

3.6.5 Protocol VLAN....................................................................错误!未定义书签。


Shenzhen Baitong Putian Technology Co., LTD

3.6.6 VLAN rules..........................................................................错误!未定义书签。

3.6.7 Private VLAN configration..................................................错误!未定义书签。

3.7 Port convergence........................................................................ 错误!未定义书签。

3.7.1 Static convergence.............................................................. 错误!未定义书签。

3.7.2 Dynamic convergence......................................................... 错误!未定义书签。

3.7.3 port informatipn..................................................................错误!未定义书签。

3.7.4 Port convergence examples................................................................................. 44

3.8 MSTP..........................................................................................................................45

3.8.1 Basic information................................................................ 错误!未定义书签。

3.8.2 Port information..................................................................错误!未定义书签。

3.8.3 STP Config........................................................................... 错误!未定义书签。

3.8.4 Port config...........................................................................错误!未定义书签。

3.9 EAPS...........................................................................................................................48

3.10 Layer 3 interface.................................................................... 错误!未定义书签。

3.10.1 Layer 3 interface management............................................ 错误!未定义书签。

3.11 Layer 3 forwading....................................................................错误!未定义书签。

3.11.1 Static ARP...........................................................................................................52

3.11.2 Router management..........................................................错误!未定义书签。

3.11.3 Static router config examples............................................错误!未定义书签。

3.12 SNMP..................................................................................................................... 57

3.12.1 SNMP config.......................................................................................................57

3.12.2 Group config....................................................................................................... 58

3.12.3 Traps config........................................................................................................59

3.12.4 SNMP config examples...................................................................................... 60

3.13 system management...............................................................错误!未定义书签。

3.13.1 Usr management.................................................................错误!未定义书签。

3.13.2 Restart OLT........................................................................................................ 62

3.13.3 System time....................................................................... 错误!未定义书签。

3.13.4 log output.......................................................................... 错误!未定义书签。

3.13.5 Ping test............................................................................................................. 64


Shenzhen Baitong Putian Technology Co., LTD

3.13.6 Traceroute..........................................................................................................65

3.13.7 File management................................................................ 错误!未定义书签。

3.13.8 Exit system.......................................................................... 错误!未定义书签。

1 About the user manual

This user manual introduce WEB configuration based on 4/8 PON OLT

1.1 Manual conventions

Different striking signs are used in the user manual to indicate where

special attention is required during operation. Below is the meaning of

those signs.

signs meaning
Warning/attention
Remind matters need pay attention to during operation.

Instructions \ prompts
Make necessary additions and instructions to the description of operations
to avoid repeating common errors.

1- 1 Symbol convention
format meanings
Bold Boldface represent the window name, menu name, button name and
different variable input and Settings in graphical interface. Click “revise”
access to “revise basic configuration” interface.
Simple operation step concatenations. For example, open Start > control
> panel > network connections successively.
Courier Courier font text represents input result of the command and command
line. for example:
#Ping -t 192.168.0.1
Shenzhen Baitong Putian Technology Co., LTD

<…> represents key press. For example, press <Ctrl> +


<…> <Alt> + <Delete> simultaneous will access to task manager
Window.

Table 1- 2 graphic interface convention

The Illustration and relevant parameters in user manual is just a

reference for guiding you how to config and use the device. There may

some slightly difference, so please config the device according to actual

situations.

2 Configuration and preparation

Before login config interface, please confirm the followings.

 The computer used for management have installed Ethernet

card.

 To achieve the best display, suggest use Microsoft IE explore (9.0

or 9.0+ version) and make sure the resolution of the displayer is

1024 x 768.

2.1 config computer IP

When config device defaults, the steps are as follows ( take windows

7 for example):

1. click <start> button at lower left corner of the screen to enter

start menu and choose <control panel>. Then click <network


Shenzhen Baitong Putian Technology Co., LTD

status> and<taste icon>, double click <local connection > icon at

the same time. Local connection status window will come out as

photo.

Figure 2- 1 Local connection status

2. click the < property > button to enter the local connection

properties window as below photo.

Figure 2- 2 local connection properties

3. choose internet protocol version 4(TCP/IPv4), click <property> button


Shenzhen Baitong Putian Technology Co., LTD

to enter internet protocol(TCP/IP property)window. Input IP address

(choose any value in 192.168.1.1-192.168.1.99

and 192.168.1.101-192.168.1.254) and subnet mask (255.255.255.0),

click confirm button.

Figure 2- 3 Internet protocol(TCP/IP property)

2.2 Check network

Check network between computer and OLT as below tow steps:

1. click <start> button at lower left corner of the screen, choose

<run>,A dialog box appears as below:

Figure 2- 4 run window


Shenzhen Baitong Putian Technology Co., LTD

2. Input ping 192.168.1.100 (use the IP address configured on OLT

before), then click enter key. If dialog box appear below response,

it means network is connected. Or please check network

connection.

Figure 2- 5 Ping command

2.3 Login EPON OLT

1. input OLT management IP in address bar with IE explore ( OLT IP

address 192.168.1.100 by default)

2. input user name and password at login interface ( OLT user name

and password are both admin by default), click< login>, then you will

enter OLT web management interface.


Shenzhen Baitong Putian Technology Co., LTD

Figure 2- 6 OLT web login interface

3 . WEB Configuration

3.1 Basic information

Web configuration of 4/8 PON OLT is divided into two parts:

menu bar and configuration area. Click menu item in menu bar

to enter corresponding configuration page, config what you

need at configuration area and check device status or config

information at the same time.


Shenzhen Baitong Putian Technology Co., LTD

Figure 3- 1 Web configuration page

3.2 system information

Click system information at menu bar to check basic information

(item name, version etc) and run information (CPU and memory status).

Figure 3- 2 run information


Shenzhen Baitong Putian Technology Co., LTD

3.3 ONU MGMT

3.3.1 ONU Information

Click ONU MGMT >PON5 (can only manage online PON port), you can

check and configure ONU information, ONU registration information,

ONU capability set.

Figure 3- 3 ONU Management

3.3.2 ONU management and configuration

Click config under the ONU registration list, which can be used to config

ONU description, VLAN etc.


Shenzhen Baitong Putian Technology Co., LTD

Figure 3- 4 ONU information

3.4 L2 interface

3.4.1 Port management

Click Port>port setting, you can revise some properties. Such as

enable/disable port, port rate, enable/disable flow control, Jumbo frame,

port description etc. click <Modify>to save.


Shenzhen Baitong Putian Technology Co., LTD

Figure 3- 5 port management

interface Description

Port range choose L2 port which need modify property

Port enable open/close port state

Port rate Set port duplex state and port rate

Flow control enable/disable port flow congestion control

Jumbo frame set L2 port jumbo-frame value (1550 by default)

egress maximum actual forwarding speed of egress port

rate-limiting

egress burst The maximum number of frames for egress port in a

burst transmission
Shenzhen Baitong Putian Technology Co., LTD

ingress maximum actual forwarding speed of ingress port

rate-limiting

ingress burst The maximum number of frames for ingress port in a

burst transmission

Port set L2 Port description

description
Table 3- 1 port management

Note:

Please do not input port name manually in textbox. Revise

port rate, egress rate-limiting, egress burst, ingress rate-limiting,

ingress burst at aggregation port is invalid.

3.4.2 Port isolation

Click Ports>port isolation, check the ports in below lists to config

port isolation. After configuration ports are isolated, the ports under

VLAN cannot communicate. Click <Modify>to save.


Shenzhen Baitong Putian Technology Co., LTD

Figure 3- 6 port isolation

interface Description

port range choose L2 port need modify

Enable port Open/close port isolation. Port isolation is closed by

isolation default.

Sheet 3- 2 port isolation

Example: as below figure , if config Ge1 and Ge2 under the same VLAN,

user1 and user2 can communicate. But if Ge1 and Ge2 are added to port

isolation, user1 and user2 can not communicate.


Shenzhen Baitong Putian Technology Co., LTD

3.4.3 Broadcast storm restriction

A broadcast storm occurs when the host system responds to a packet

that is constantly circulating on the Internet or trying to respond to an

unresponsive system. Normally in order to change the situation,

Requests or response groups are continuously generated, this will make

situation worse. As the number of network groups increases, the

congestion appears which will reduce the network performance even

make it paralyzed.

Click Ports> storm control; check port to config relevant port

restriction. Click <Modify> to save; click <delete> to restore the number

of storm restriction by default.


Shenzhen Baitong Putian Technology Co., LTD

Figure 3- 7 storm restriction

Interface Description

port range choose L2 port need modify

Broadcasting Set broadcasting restriction PPS, range from 0 to

data packet 100000, disable by default

multicast data Set multicast packet restriction PPS, range from 0 to

packet 100000, disable by default

unknown Set unicast packet restriction PPS, range from 0 to

unicast packet 100000, disable by default

Sheet 3- 3 storm restriction

case:
Shenzhen Baitong Putian Technology Co., LTD

1. Close OLT broadcasting restriction and send speed limit broadcast

packet from testing equipment to the port 1, you will find if not

control the broadcast packets received by other ports of DUT, the

communication between DUT and PC will be influenced.

2. Only open broadcast control of port 1 and set value as 500, then send

rate-limiting packet to the device connect to DUT port1, you will find

the broadcasting packet received by other ports DUT is in the scope

of storm control, but no impact on DUT.

3.4.4 Port mirror

Port mirror means copy the specific port message to mirror

destination port. Mirror destination port will access flow analysis

equipments. Users can use those equipments to analyze the flow

received from destination port and to do network monitoring and

trouble removal.

Click ports>port mirror; set monitoring port and mirror port


Shenzhen Baitong Putian Technology Co., LTD

Figure 3- 8 port mirror

Interface Description

mirror port Set port to be monitored, that is source port of flow

Monitoring Set monitoring port, that is destination port of flow, to

port connect flow monitoring and analysis equipment

Direction Set the data acquisition direction of the monitored port

Note:

Modification can only change the data acquisition direction value,

which is called direction.


Shenzhen Baitong Putian Technology Co., LTD

Configure port 3 to monitor port 2 receive packets; PC2 sends packets to

PC1, then PC3 on port3 can receive packets sent by PC2.

3.5 L2 forward

3.5.1 Forward table

OLT need maintain the MAC address forward table to make sure

forwarding message quickly. MAC address forwarding table is a

port-based L2 forwarding table. It is the foundation of OLT to realize L2

message to be forwarded quickly. MAC address forwarding table includes

destination MAC address, VLAN ID of the port and forwarding port no.

etc

Click L2 forward>MAC Address table; modify configuration of L2

forward table.
Shenzhen Baitong Putian Technology Co., LTD

Figure 3- 9 forward table

Interface Description

Aging time Modify aging time of forward table, 300s by default. It

can be set as “0”, “0”mean no aging.

Delete L2 table L2 table item can be deleted as per conditions of VLAN,

item port ID, MAC address etc. or you can delete all with

<clear> button.

Table 3- 4 forward table

Attention:

Delete and clear operations can only remove MAC address


Shenzhen Baitong Putian Technology Co., LTD

table items of dynamic type

Config instance:

1. If PC1 can ping PC2 successfully, MAC address L2 forwarding table of

PC1 and PC2 will show on DUT.

2. Shut down automatic learning function of OLT MAC table and modify

aging time, you will find L2 forwarding table will be deleted.

3. You can also delete L2 forwarding table by pressing VLAN, port or

MAC address manually.

3.5.2 Static MAC and filtration

Click L2 forward>static MAC&Filter to set static MAC filtration.


Shenzhen Baitong Putian Technology Co., LTD

Figure 3- 10 Static MAC and filter

interface description

VLAN Set VLAN of the static MAC address

MAC address Set MAC address of corresponding destination

Functions Static MAC refers to adding a MAC address static

table item, which need specific forwarding port.

While MAC address filtration will filter corresponding

MAC address, no need specific forwarding port.

Table 3- 5 Static MAC and filtration

Note:

MAC address filtration includes the filtration of both source

MAC and destination MAC

Config instance:
Shenzhen Baitong Putian Technology Co., LTD

1. If DUT turn off MAC learning function of OLT, we can add static MAC

address manually to realize L2 forward table. Fill in the VLAN,GE4 Ports

and MAC address of PC1.

2.Connect PC1 to GE2 port, you will find PC1 and PC2 cannot ping.

3. Connect PC1 to GE4 port, config MAC address binding of PC1 which

belongs to VLAN2. You will find PC1 and PC2 cannot Ping too.

4. To filter out some MAC address, you can use MAC address filtration. If

filter MAC address of PC1, you will find PC1 and PC2 cannot Ping.

3.5.3 MAC binding

Click L2 forward>MAC binding to bind MAC address


Shenzhen Baitong Putian Technology Co., LTD

Figure 3- 11 MAC binding

interface description

port Set physical port of MAC address binding

MAC address Set destination MAC address

VLAN Set corresponding VLAN ID

Table 3- 6 MAC binding

Attention

MAC binding will close port MAC learning function. Only binding MAC

address can forward.

Config instance:
Shenzhen Baitong Putian Technology Co., LTD

1. If DUT close MAC address automatic learning function, you can bind

MAC address, VLAN with egress port. Config MAC address bindings (not

PC1 MAC address) to see binding entries, PC1 and PC2 can’t ping each

other.

2. Config MAC address bindings of PC1, PC1, PC2 and DUT can be

interconnected.

3. Connect PC1 to GE2 port, PC1、PC2、DUT can’t ping each other

4. Connect PC1 to GE4 port, config MAC address bindings of PC1,which

belongs to VLAN2, PC1、PC2、DUT can’t ping each other.

3.5.4 MAC automatic binding

Click L2 forward>MAC auto binding to bind MAC automatically.


Shenzhen Baitong Putian Technology Co., LTD

Figure 3- 12 MAC automatic binding

interface Description

port Set physical port of MAC address automatic binding

MAC address set destination MAC address of binding

VLAN Set corresponding VLAN ID

Table 3- 7 MAC automatic binding

Attention

MAC binding will close port MAC learning function. Only

binding MAC address can forward. Each port max binds 64 dynamic MAC

address.
Shenzhen Baitong Putian Technology Co., LTD

3.5.5 MAC learning Limit

Click L2 forward>MAC learning limit to set MAC learning restriction

Figure 3- 13 MAC learning restriction

Interface Description

port Set physical port of MAC address learning

restriction

MAC Secure Address Set learning limit of network ports

Table 3- 8 MAC Learning settings

Config instance:
Shenzhen Baitong Putian Technology Co., LTD

1. If DUT learn too much L2 forwarding might affect its performance,

so we need set MAC learning restriction. Config MAC address learning

restriction number; PC1 sends the source jump MAC address (not PC1

address) which is more than the number of limitation to DUT, you will

find the Maximum number of binding tables.

2. PC1 and PC2 send Ping package to each other, but can’t ping each

other.

3. Modify the number of MAC address learning restrictions; PC1 sends

the source jump MAC address (not PC1 address) which is less than

the number of limitation to DUT. In this situation, DUT can learn new

MAC table, that is MAC address of PC1. PC1 and PC2 can ping each

other.

3.6 VLAN

VLAN divides a physical LAN into multiple logical LAN. Each VLAN is a

broadcast domain. Hosts in VLAN can interact message by traditional

Ethernet communication. But hosts in different VLAN have to realize


Shenzhen Baitong Putian Technology Co., LTD

communication via router or L3 switch.

3.6.1 VLAN Config

Click VLAN config>VLAN Config to modify or config 802.IQ VLAN. Click

<add> to finish setting.

Figure 3- 14 802.1Q VLAN setting

Interface Description

VLAN ID Set VLAN ID. Batch create or delete multiple

continuous VLAN need connect each VLAN

with strigular. For example, 3-10

Name Set VLAN name. VLANxxxx by default

status Enable/disable VLAN status. Enable by default


Shenzhen Baitong Putian Technology Co., LTD

Table 3- 9 802.1Q VLAN setting

Note:

100 continuous VLAN can be created or deleted

at a time

3.6.2 Port VLAN

Click VLAN Config>Port-based VLAN to modify or config Port VLAN. Click

<add> to finish setting.

Figure 3- 15 Port VLAN

Interface Description
Shenzhen Baitong Putian Technology Co., LTD

Port Range Choose L2 port of VLAN properties need to

modify in page check box.

Link type Set link type of port. All ports are “access” by

default

Acceptable frame Set acceptable frame type. For example, set

type VLAN-untagged as untagged, set VLAN-tagged

as tagged. “All” by default.

ingress filter Set if open ingress filtration. Close by default.

Allowed VLAN ID Set allowed VLAN ID in trunk mode

Default VLAN ID Set default VLAN ID, default ID is “1” in trunk

mode

Table 3- 10 Port VLAN

Attention:

Before setting Allowed VLAN and Default VLAN, you

need modify link type of ports.

Config instance:
Shenzhen Baitong Putian Technology Co., LTD

Create VLAN 10 and VLAN of ge4 and ge2 port as access port at

the same time. PC1 and PC2 can ping each other.

3.6.3 Ip Subnet VLAN

Click VLAN config>IP subnet VLAN to modify and config subnet VLAN.

Click <add> to finish setting.

Then OLT will check IP package source address at ingress port. Data

package is processed at which VLAN depends on this source address and

config rules.
Shenzhen Baitong Putian Technology Co., LTD

Figure 3- 16 subnet VLAN

interface description

Rule ID IP subnet VLAN corresponding rule ID. Range is

1000-1999

IP address Set subnet segment which need allocate

specified VLAN ID

VID Set VLAN ID for dynamic allocation

Table 3- 11 subnet VLAN

3.6.4 MAC-Based VLAN

Click VLAN config>MAC-based VLAN to modify and config MAC

VLAN. Click <add> to finish setting.


Shenzhen Baitong Putian Technology Co., LTD

MAC VLAN configuration make MAC address correspond with

VLAN ID. And OLT determine the device belongs to which VLAN by

checking MAC address connecting to the device.

Figure 3- 17 MAC-Based VLAN

interface description

Rule ID Subnet VLAN corresponding rule ID. Range is

1000-1999

MAC address Set MAC address which need allocate specified

MAC address

VID Set VLAN ID for dynamic allocation

Table 3- 12 MAC-Based VLAN


Shenzhen Baitong Putian Technology Co., LTD

3.6.5 Protocol-based VLAN

Click VLAN config> Protocol-based VLAN to modify or config

protocol VLAN. Click <add> to finish setting.

This OLT will checked the encapsulation protocol at the ingress port

and according to the encapsulation protocol rules, which VLAN is

handled in the packet.

Figure 3- 18 Protocol VLAN

Interface Description

Rule ID Subnet VLAN corresponding rule ID. Range is

2000-2099

Protocol type subnet protocol type which need allocate

specified VLAN ID. Protocol number is

0-65535
Shenzhen Baitong Putian Technology Co., LTD

ENCAP Set ENCAP type. There are three types at the

moment, ethv2,nosnapllc and snapllc

VID Set VLAN ID for dynamic allocation

Table 3- 13 Protocol VLAN

3.6.6 VLAN rule

Click VLAN config>VLAN rule to config VLAN rule. Click <add> to finish

setting.

Figure 3- 19 VLAN rule

Interface Description

Port choose the port need config

MAC-Based VLAN enable MAC-based VLAN at corresponding


Shenzhen Baitong Putian Technology Co., LTD

port

Subnet VLAN Enable IP-based subnet VLAN at corresponding

port

Protocol VLAN Enable Ethernet-based VLAN (with Rule ID) at

corresponding port

Table 3- 14 VLAN rule

Config instance:

1. As above Figure , user1 and user4 can communicate with each

other. But user 1 and user4 can’t communicate with uer2 and

user3. OLT need create VLAN2, VLAN3; config port VLAN which

connect to users as access port; config the port connect to OLT

as Trunk port, and Trunk port allow all VLAN pass.

2. If want to set a user of 192.168.10.0/24 network segment as

VLAN2, you can use subnet VLAN to config.

3. If want to set a user of fixed MAC as VLAN 3 , you can use

MAC-Based VLAN。
Shenzhen Baitong Putian Technology Co., LTD

4. If want to set package of the fixed protocol as VLAN 3,you can

user protocol-based VLAN.

5. Finally,add VLAN rule id to port .

3.6.7 Private VLAN configuration

Click VLAN config>private VLAN configuration to config VLAN rule.

Click <add> to finish setting.

Figure 3- 20 private VLAN configuration


Shenzhen Baitong Putian Technology Co., LTD

3.7 Trunk

3.7.1 static Aggregation

Static aggregation manual binding multiple physical ports to a

logical accordingly increasing the bandwidth between OLT and

network node. Static aggregation does not allow the system to

auto add or delete port in the trunk group. The trunk group

contain at least one port.

Click Trunk > Static aggregation to config static aggregation. Click

<add> to finish setting.

Figure 3- 21 static aggregation


Shenzhen Baitong Putian Technology Co., LTD

interface Description

port Select the ports that need static aggregation,

which can be multiple selected.

Aggregation Add to setting aggregation group ID

group ID

table 3- 15 static aggregation

3.7.2 Dynamic aggregation

LACP binding physical port to a logical port, The physical port

negotiated through the LACP protocol can be binded into a logical

port and other ports will not be binded into the logical port, the

layer 2 attribute of these physical ports must be the same, such as:

speed,duplex ,VLAN and so on.

Click Trunk > Dynamic aggregation to config LACP. Click <add> to

finish setting.
Shenzhen Baitong Putian Technology Co., LTD

Figure 3- 22 Dynamic aggregation

interface Description

LACP configuration Set port、LACP aggregation ID and LACP mode

LACP group list Show and delete related dynamic aggregation

group

Aggregation group Show the dynamic aggregation group and

information set load balancing.

table 3- 16 dynamic aggregation

Note:

Dynamic aggregation list can show and delete related

dynamic group.
Shenzhen Baitong Putian Technology Co., LTD

3.7.3 Port information

Click Trunk> Port information,show detailed information of the

related aggregation members.

Figure 3- 23 Port information


Shenzhen Baitong Putian Technology Co., LTD

3.7.4 Port trunk config instance

Networking requirement:

OLT 1 user two port (Ge1~2) trunk OLT 2 to achieve the maximum 2G

flow of PC1 and PC2, achieve Load Balancing of traffic in each member

port.

Static aggregation config steps:

at Figure 3.7.1,check out ge1,ge2,filled in“aggregation group ID”,

click“add”button.

Dynamic aggregation config steps:

At Figure 3.7.2,“LACP config” choice ge1,filled in“group ID”,then

click“Create”button ; And then choice ge2 , filled in the same as ge1


Shenzhen Baitong Putian Technology Co., LTD

“group ID”,then click“Create”. LACP needs to be added individually to

each port.

3.8 MSTP

MSTP (Multi Spanning Tree MST) protocol is a two layer management

protocol which selectively blocking redundant links in the network to

eliminate of two layers loop, it also has function of link backup. MSTP

can fetch up the defect of STP and RSTP, it can converge quickly, but it

also enable different VLAN traffic to be forwarded along their

respective path, thus providing a better load sharing mechanism for

redundant link.

3.8.1 Basic information

Click MSTP > Basic info to show configuration information at the

MSTP domain.
Shenzhen Baitong Putian Technology Co., LTD

Figure 3- 24 Basic information

3.8.2 Port information

Click MSTP > Port information,show the basic information of STP

bridge and the attribute information related to STP of the port.

Figure 3- 25 Port information

3.8.3 STP configuration

Click MSTP > STP configuration to STP attribute configuration.


Shenzhen Baitong Putian Technology Co., LTD

Figure 3- 26 STP configuration

interface Description

MSTP state Shut down or turn on MSTP protocol state,

shut down by default .

priority MSTP priority

table 3- 17 MSTP configuration

3.8.4 Port configuration

Click MSTP > Port configuration to configure port MSTP related

attributes which including path cost, priority, portfast , root

protection and so on. Click <Modify> to save port configuration.


Shenzhen Baitong Putian Technology Co., LTD

Figure 3- 27 Port configuration

3.9 EAPS

3.9.1 EAPS Management

EAPS is link layer protocol for Ethernet loop protection. It can

prevent a broadcast storm from the data loop when it's all over the

Ethernet ring, and when a link on the Ethernet loop is broken, it

quickly restores the traffic pathways between each of the nodes on

the Internet. Configure EAPS protocol parameters which including

ring ID, mode, extreme compatibility, primary port, second port,

control VLAN, protection VLAN, failure time and hello time.

Note:

It is must to correctly configure all the properties of EAPS to

enable the ring. All properties of the modified ring must be


Shenzhen Baitong Putian Technology Co., LTD

closed to the ring.

Click EAPS > EAPS Management to configure EAPS。

Figure 3- 28 EAPS management

Configuration instance:

The OLT1,OLT2 and OLT3 which is not possible to form a loop when

VLAN 1 is protect by EAPS protocol, and it is guaranteed to enable that

standby link with a link open between OLT 1, OLT 2 and OLT 3. According

to the above requirements, OLT 1 can be configured as master node, OLT

2 and OLT 3 as transit nodes. Finally add a control VLAN(i.e VLAN 2) for

packet transmission.
Shenzhen Baitong Putian Technology Co., LTD

 Configuration OLT 1:

OLT 1 is configured as the master of EAPS Domain ring 1, the

control VLAN is VLAN2, the protected VLAN is VLAN 1, the

primary-port is ge1 and secondary-port is ge2 .Finally other

values is defaulted.

 Configuration OLT 2 :

OLT 2 is configured as the transit of EAPS Domain ring 1,the

control VLAN is VLAN2,the protected VLAN is VLAN1, the

primary-port is ge1 and secondary-port is ge2.Finally other values

is defaulted.

 Configuration OLT 3:

OLT3 is configured as the transit of EAPS Domain ring 1,the control

VLAN is VLAN 2,the protected VLAN is VLAN1, the primary-port is ge1

and secondary-port is ge2.Finally other values is defaulted.


Shenzhen Baitong Putian Technology Co., LTD

3.10 Layer 3 interface

3.10.1 Layer 3 Management

Clink L3 interfaces> L3 Management to configuration L3 interface.

Figure 3- 29 L3 interface Management

Interface Description

VLAN ID Set L3 interface VLAN

IP address Set L3 interface ip address

ARP AGE time Set L3 interface ARP age time, 3000 seconds is

defaulted.
Shenzhen Baitong Putian Technology Co., LTD

State Set L3 interface management statue(UP/DOWN).

Secondary IP Set L3 interface secondary ip address.

address

Table 3- 18 L3 interface management

Note:

You must create a L3 interface and configure the primary IP

address before configuring the secondary IP address.

3.11 Layer 3 forwading

3.11.1 Static ARP

The static ARP refers to the mapping between IP and MAC

address which will not be aged and deleted dynamically.

Click L3 forward > static ARP for static ARP configuration.


Shenzhen Baitong Putian Technology Co., LTD

Figure 3- 30 Static ARP

Interface Description

IP address The corresponding IP address in the ARP table

item.

MAC address The corresponding MAC address in the ARP

table item.

Table 3- 19 Static ARP

Note:

If you want to clear ARP table items, you can only delete

dynamic ARP table items.

3.11.2 Route Management

Click L3 forward > Route Management for static routing Settings.


Shenzhen Baitong Putian Technology Co., LTD

Figure 3- 31 Static route management

Interface Description

Destination IP This is the destination IP address segment of

static routing.

Next Hop This is the next hop IP address for static routing.

Table 3- 20 Static route management

Note:

You can only add and remove static routing in the routing

management, but you can show all routing information of the device.
Shenzhen Baitong Putian Technology Co., LTD

3.11.3 Static router config examples

Network requirement:

 There are VLAN2 and VLAN4 in OLT1 and VLAN3 and VLAN4 in

OLT2. This two OLT devices are connected through the ge2

port which belonging to VLAN4, user A belong to VLAN2 and

user B belong to VLAN3. The following figure topology

configure the relevant parameters of each VLAN and the L3

interface of VLAN.

 You can configure static routing on OLT1 and OLT2 so that

user A and user B can communicate.

 You can configure user A static ARP table entry on OLT1 and

user A MAC address is 0000.0000.

Figure 3.11.3.1
Shenzhen Baitong Putian Technology Co., LTD

Configuration Steps:

1. Refer to 3.6.1 to create VLAN2 and VLAN4 on OLT1 and VLAN3

and VLAN4 on OLT2.

2. Refer to 3.6.2 to add VLAN2 on the port of ge1 and VLAN4 on the

port of ge2 on OLT1. You can add VLAN3 on the port of ge1 and

add VLAN4 on the port of ge2 on OLT2.

3. Refer to 3.10.1 to configure the L3 interface IP address on OLT1

and OLT2. The address information is as shown in the figure

above.

4. Configure static routing on OLT1:

In the figure 3.11.3.1, you can set the destination IP address is

192.168.2.2/24 and set the next hop IP address is

192.168.3.2,then please click <add > button.

5. Configure static routing on OLT2:

In the figure 3.11.3.1, you can set the destination IP address is

192.168.1.2/24 and set the next hop IP address is

192.168.3.1,then please click <add> button.

6. Configure static ARP on OLT1:

As shown in figure 3.11.3.1, you can set IP address is

192.168.1.2 and set MAC address is 0000.0000.AAAA (this

is user A network MAC address.).Then please click <add> button.


Shenzhen Baitong Putian Technology Co., LTD

3.12 SNMP

SNMP ( Simple Network Management Protocol ) is used for

transferring management information between arbitrary two

points, providing convenience for network manger to retrieve and

modify information, locate fault, diagnose fault, do Capacity

planning and report generation at any node.

3.12.1 SNMP Configuration

Click SNMP > SNMP Management to config SNMP parameters.

Figure 3- 32 SNMP configuration

Interface Description

Administrator System management maintenance contact information.


Shenzhen Baitong Putian Technology Co., LTD

Device Location Physical location information of the device.

Table 3- 21 SNMP configuration

3.12.2 Community configuration

Click SNMP > Group Management to set the community name

and read&write permission of SNMP.

Figure 3- 33 Group configuration

Note:

The list of community name allows you to show and delete

information.
Shenzhen Baitong Putian Technology Co., LTD

3.12.3 Traps Configuration

Click SNMP> Traps Management to configure trap parameters.

Figure 3- 34 Traps Configuration

Interface Description

SNMP Traps Set the community name and read&write permission of

SNMP.

Traps host Trap host IP address configuration and corresponding

group name Settings

Table 3- 22 Traps configuration


Shenzhen Baitong Putian Technology Co., LTD

Note:

The Trap list allow you to show and delete information.

3.12.4 SNMP configuration instance

Network requirement:

 Allow client PC1 to read the MIB node information of OLT1

through the read-write test of community with the SNMP

browser.

 Allowed OLT1 send trap to the server PC2:192.168.65.199

with format of the SNMPv2 at the same time. The community

with name as test.

Configuration Steps:

1. In the figure 3- 33 group configuration, config group name as

test, Permissions as rw permission .Then click <add> button to


Shenzhen Baitong Putian Technology Co., LTD

complete.

2. In the figure 3- 34 Traps configuration, set SNMP trap as enable

and click <Modify> to complete. Then set traps host as

192.168.65.199( it’s PC2’s IP address) and the group name as test.

Finally please click <add> button to complete.

3.13 System Management

3.13.1 User Management

Click System MGMT> User Management to modify the current

user password.

Figure 3- 35 user management


Shenzhen Baitong Putian Technology Co., LTD

Note:

You can only change the password for the current user.

3.13.2 Restart OLT

Click System MGMT> Device Restart to restart the current device

Figure 3- 36 restart OLT

3.13.3 System Time

Click System MGMT> System time to set device system time.


Shenzhen Baitong Putian Technology Co., LTD

Figure 3- 37 System time

Note:

System time cannot be saved if RTC is not supported.

3.13.4 Log Output

Click System MGMT> Log information to show current device log

output information.
Shenzhen Baitong Putian Technology Co., LTD

Figure 3- 38 Log output

3.13.5 Ping Diagnostics

Click System MGMT> Ping Diagnostics to diagnose the accessibility

of the destination IP address.


Shenzhen Baitong Putian Technology Co., LTD

Figure 3- 39 Ping diagnostics

3.13.6 Traceroute

Click System MGMT> Trace route to detect the path information

of destination IP address.
Shenzhen Baitong Putian Technology Co., LTD

Figure 3- 40 Trace route detect

3.13.7 File Management

Click System MGMT> File management to show, upload/download

configuration files or restore factory Settings.


Shenzhen Baitong Putian Technology Co., LTD

Figure 3- 41 file management

Interface Description

Current Version Display current version information and the

download of the current version image

Software upgrade Update image file (fs3526_4.img.gz) through

WEB.

Upload configuration Upload backup OLT profile through WEB.

Download Download the configuration file saved by the

configuration File current device.

Download running Download the current running status file

status File

Save all configuration Save all the page configuration information


Table 3- 23 File management
Shenzhen Baitong Putian Technology Co., LTD

3.13.8 Restore to factory settings

Click System MGMT> Restore to factory settings to restore to factory

settings.

3.13.9 Log out

Click System MGMT> Log out to log out the Web management

system.
Shenzhen Baitong Putian Technology Co., LTD

Abbreviation list:

ARP Address Resolution Protocol

BPDU Bridge Protocol Data Unit

EAPS Ethernet Automatic Protection Switching

LACP Link Aggregation Control Protocol

MSTP Multiple Spanning Tree Protocol

RSTP Rapid spanning Tree Protocol

RTP Real-time Transport Protocol

SNMP Simple Network Management Protocol

STP Spanning Tree Protocol

VLAN Virtual Local Area Network