Infinosis™ 2020 Salessheet 2021 - V180221

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

Infinosis™ 2020 price list

Featuring the time-resolved 3uorescent immunoassay

F
L
A
Infinosis™ FIA
Infinosis™ 2020 system
Time-resolved 3uorescent immunoassay

Principle Fluorescent immunochromatography


Display 7” LCD touch screen
Performance Repeatability: CV ≤ 3%
Stability: σ ≤ ±8%
Linear correlation: r ≥ 0.97
Don’t blink
Accuracy: Δn ≤ ±15% It reads too fast
Measurement mode Single mode, QC test and review (save results)
mode Just 1 sec
Sample types Whole blood, serum, plasma or urine
Data storage 20,000 records
Optical description Excitation light source: LED, 365nm
Detector: 610nm photodiode
Connectivity Built-in thermal printer
LIS connection
LAN
USB
Dimensions 290mm (L) x 240mm (W) x 120mm (H) Well controlled
Weight
Power supply
2.0 Kg
AC100 V - AC240 V, 50 Hz - 60 Hz
coefficient variation
Just ≤ 3%

Thermal printer 7’’ LCD touch screen

User-friendly
software interface
Just finger click

Test cartridge holder

Physical photo on Infinosis™ 2020 analyzer ID Card

Fast · Reliable · Efficient …


Infinosis™ FIA

AMH testing

Infinosis™ AMH FIA test

Test principle Sample type Reaction time Detection range


Time-resolved FIA test Whole blood, serum 15 minutes 0.1-20 ng/mL
Sandwich method or plasma

Method comparison
25
y = 0.9858x + 0.1676
Infinosis™ AMH FIA assay (ng/mL)

A comparison of the Infinosis™ AMH FIA R² = 0.9824


20
assay (y) with the Roche Elecsys® AMH
ECLIA assay (x) using clinical samples gave 15
the following correlations:
10
Number of samples measured: 56
5

0
0 5 10 15 20 25
Roche Elecsys® AMH ECLIA assay (ng/mL)

25
y = 0.9967x + 0.0031
Infinosis™ AMH FIA assay (ng/mL)

A comparison of the Infinosis™ AMH FIA R² = 0.9899


20
assay (y) with the DiaSino® AMH ELISA
assay (x) using clinical samples gave the 15
following correlations:
10
Number of samples measured: 127
5

0
0 5 10 15 20 25
DiaSino® AMH ELISA assay (ng/mL)

~1,200,000 AMH ELISA tests shipped*


Je success story of AMH continues…
* Total sales of 96 tests microplate based AMH ELISA kits between 04/2018 - 12/2020
Infinosis™ FIA

Vitamin D testing

Infinosis™ Vitamin D total FIA test

Test principle Sample type Reaction time Detection range


Time-resolved FIA test Serum or plasma 15 minutes 2.0 - 200 ng/mL
Competition method

Method comparison
80
y = 1.0576x - 1.1588
A comparison of the Infinosis™ Vitamin D
Infinosis™ Vitamin D FIA (ng/mL)

R² = 0.9613
FIA (y) with the Roche Elecsys® Vitamin D 60
ECLIA (x) using clinical samples gave the
following correlations: 40

Number of samples measured: 48


20

0
0 20 40 60 80
Roche Elecsys® Vitamin D ECLIA (ng/mL)

80
y = 1.0037x - 0.1261
A comparison of the Infinosis™ Vitamin D
Infinosis™ Vitamin D FIA (ng/mL)

R² = 0.9822
FIA (y) with the DiaSino® Vitamin D ELISA 60
(x) using clinical samples gave the following
correlations: 40

Number of samples measured: 112


20

0
0 20 40 60 80
DiaSino® Vitamin D ELISA (ng/mL)

One of DiaSino highlighted products …


Infinosis™ FIA
Infinosis™ 2020 FIA test menu
PRODUCT NAME CATLOG NUMBER
Thyroid
TSH IN017701
T3 IN017702
T4 IN017703
Free T3 IN017704
Free T4 IN017705
Fertility
AMH IN027701

β-hCG IN027702

LH IN027703
FSH IN027704
PRL IN027705
Progesterone IN027706
Testosterone IN027707
E2 IN027708
AMH/LH/FSH IN027709
Bone
25OH Vitamin total IN037701
Cardiac
cTnI IN047701
Myo IN047702
CK-MB IN047703
CTnI/Myo/CK-MB IN047704
NT-proBNP IN047705
D-Dimer IN047706
hFABP IN047707
BNP IN047708
Lp-PLA2 IN047709
Sepsis/Inflammation
PCT IN057701
hsCRP + CRP IN057702
SAA IN057703
IL-6 IN057704
Others
HbA1c IN067701
NGAL IN067702
mAlb IN067703
Cys-C IN067704
Total IgE IN067705
Ferritin IN067706

Infinosis™ 2020 Analyzer IN772020


©2021 DiaSino

Immunodiagnostics Product Catalog 2021


DiaSino Headquarters
DiaSino Laboratories Co., Ltd.
No.68 Jingnansi Road
National Eco & Tech Development Area
450000 Zhengzhou, China
Phone: +86 371 5569 5727
[email protected]

www.diasino.com

You might also like