50% found this document useful (2 votes)
2K views1 page

Blower and Design Calculation

The document provides design calculations for a water treatment plant filtration system including: the plant capacity of 7.4 MLD served by 4 filter beds, with a required filtration rate of 4.84 m3/hr/m2. It also calculates the required blower capacity of 860 m3/hr to backwash the filter beds that are each 3.9m wide by 4.9m long, with an area of 19.11 m2.

Uploaded by

sharan kommi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
50% found this document useful (2 votes)
2K views1 page

Blower and Design Calculation

The document provides design calculations for a water treatment plant filtration system including: the plant capacity of 7.4 MLD served by 4 filter beds, with a required filtration rate of 4.84 m3/hr/m2. It also calculates the required blower capacity of 860 m3/hr to backwash the filter beds that are each 3.9m wide by 4.9m long, with an area of 19.11 m2.

Uploaded by

sharan kommi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

PROJECT – WTP @ T.

NARSARIPURA
DESIGN CALCULATION – FILTRATION RATE

S.NO PARAMETERS UNITS FILTER BED

1 Capacity MLD 7.4

2 Qty of Beds 4

3 Flow through each bed (mld) MLD 1.85

4 Flow through each bed (m3/hr) m3/hr 92.5

5 Size of filter bed 4.9X3.9

6 Area of each filter bed (m2) m2 19.11

7 Filtration Rate - Required m3/hr/m2 4.840

BLOWER CAPACITY CALCULATION

CAPACITY OF WTP - 7.4MLD

SIZE OF EACH FILTER BED - 3.9M wide X 4.9M Length


AREA OF EACH FILTER BED - 19.11 M2
AIR FLOWRATE DURING BACKWASH - 45M3/M2/HR

AIR BLOWER CAPACITY - 45 * 19.11 = 860M3/HR.


BLOWER CAPACITY REQUIRED -860M3/HR.